VAR-202412-0348
Vulnerability from variot - Updated: 2025-10-03 21:58A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25000). Siemens' Teamcenter Visualization and Tecnomatix Plant Simulation Exists in a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of WRL files in the wrltojt module. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. Siemens Teamcenter Visualization is a software that provides team collaboration capabilities for designing 2D and 3D scenes. The software simplifies engineering and manufacturing processes by creating virtual prototypes from a variety of mechanical computer-aided design (MCAD) formats. Siemens Tecnomatix Plant Simulation is an industrial control device. Use the power of discrete event simulation to analyze and optimize production volume and improve manufacturing system performance
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202412-0348",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2312.0"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3.0.12"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2.0.14"
},
{
"model": "tecnomatix plant simulation",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2404.0"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3"
},
{
"model": "tecnomatix plant simulation",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2302.0016"
},
{
"model": "tecnomatix plant simulation",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2302.0"
},
{
"model": "tecnomatix plant simulation",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2404.0005"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2312.0008"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.2"
},
{
"model": "tecnomatix plant simulation",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "teamcenter visualization",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "tecnomatix plant simulation",
"scope": null,
"trust": 0.7,
"vendor": "siemens",
"version": null
},
{
"model": "tecnomatix plant simulation",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v2302\u003cv2302.0016"
},
{
"model": "tecnomatix plant simulation",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v2404\u003cv2404.0005"
},
{
"model": "teamcenter visualization",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v14.2\u003cv14.2.0.14"
},
{
"model": "teamcenter visualization",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v14.3\u003cv14.3.0.12"
},
{
"model": "teamcenter visualization",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v2312\u003cv2312.0008"
},
{
"model": "teamcenter visualization",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v2406\u003cv2406.0005"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-059"
},
{
"db": "CNVD",
"id": "CNVD-2025-02597"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-028258"
},
{
"db": "NVD",
"id": "CVE-2024-53041"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Rocco Calvi (@TecR0c) with TecSecurity",
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-059"
}
],
"trust": 0.7
},
"cve": "CVE-2024-53041",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2025-02597",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "productcert@siemens.com",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2024-53041",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-028258",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2024-53041",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "productcert@siemens.com",
"id": "CVE-2024-53041",
"trust": 1.0,
"value": "High"
},
{
"author": "OTHER",
"id": "JVNDB-2024-028258",
"trust": 0.8,
"value": "High"
},
{
"author": "ZDI",
"id": "CVE-2024-53041",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2025-02597",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-059"
},
{
"db": "CNVD",
"id": "CNVD-2025-02597"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-028258"
},
{
"db": "NVD",
"id": "CVE-2024-53041"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0016), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0005). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files. \r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25000). Siemens\u0027 Teamcenter Visualization and Tecnomatix Plant Simulation Exists in a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of WRL files in the wrltojt module. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. Siemens Teamcenter Visualization is a software that provides team collaboration capabilities for designing 2D and 3D scenes. The software simplifies engineering and manufacturing processes by creating virtual prototypes from a variety of mechanical computer-aided design (MCAD) formats. Siemens Tecnomatix Plant Simulation is an industrial control device. Use the power of discrete event simulation to analyze and optimize production volume and improve manufacturing system performance",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-53041"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-028258"
},
{
"db": "ZDI",
"id": "ZDI-25-059"
},
{
"db": "CNVD",
"id": "CNVD-2025-02597"
}
],
"trust": 2.79
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-53041",
"trust": 3.9
},
{
"db": "SIEMENS",
"id": "SSA-583523",
"trust": 2.4
},
{
"db": "SIEMENS",
"id": "SSA-645131",
"trust": 1.8
},
{
"db": "JVN",
"id": "JVNVU91750786",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-24-347-09",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2024-028258",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-25000",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-25-059",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2025-02597",
"trust": 0.6
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-059"
},
{
"db": "CNVD",
"id": "CNVD-2025-02597"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-028258"
},
{
"db": "NVD",
"id": "CVE-2024-53041"
}
]
},
"id": "VAR-202412-0348",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-02597"
}
],
"trust": 0.8745396
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-02597"
}
]
},
"last_update_date": "2025-10-03T21:58:30.428000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Siemens has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-583523.html"
},
{
"title": "Patch for Siemens Teamcenter Visualization/Tecnomatix Plant Simulation Buffer Overflow Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/654596"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-059"
},
{
"db": "CNVD",
"id": "CNVD-2025-02597"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-028258"
},
{
"db": "NVD",
"id": "CVE-2024-53041"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.1,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-583523.html"
},
{
"trust": 1.8,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu91750786/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-53041"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-347-09"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-059"
},
{
"db": "CNVD",
"id": "CNVD-2025-02597"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-028258"
},
{
"db": "NVD",
"id": "CVE-2024-53041"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-25-059"
},
{
"db": "CNVD",
"id": "CNVD-2025-02597"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-028258"
},
{
"db": "NVD",
"id": "CVE-2024-53041"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-01-22T00:00:00",
"db": "ZDI",
"id": "ZDI-25-059"
},
{
"date": "2025-02-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-02597"
},
{
"date": "2025-09-30T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-028258"
},
{
"date": "2024-12-10T14:30:46.507000",
"db": "NVD",
"id": "CVE-2024-53041"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-01-22T00:00:00",
"db": "ZDI",
"id": "ZDI-25-059"
},
{
"date": "2025-02-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-02597"
},
{
"date": "2025-09-30T08:18:00",
"db": "JVNDB",
"id": "JVNDB-2024-028258"
},
{
"date": "2025-09-24T19:40:50.583000",
"db": "NVD",
"id": "CVE-2024-53041"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a0Teamcenter\u00a0Visualization\u00a0 and \u00a0Tecnomatix\u00a0Plant\u00a0Simulation\u00a0 Stack-based buffer overflow vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-028258"
}
],
"trust": 0.8
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.