VAR-202503-0279
Vulnerability from variot - Updated: 2025-10-03 21:35A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process. Siemens' Teamcenter Visualization and Tecnomatix Plant Simulation Exists in a vulnerability related to the use of freed memory.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens Teamcenter Visualization is a software that provides team collaboration capabilities for designing 2D and 3D scenes. The software simplifies engineering and manufacturing processes by creating virtual prototypes from a variety of mechanical computer-aided design (MCAD) formats. Siemens Tecnomatix Plant Simulation is an industrial control device. Use the power of discrete event simulation to analyze and optimize production volume, thereby improving manufacturing system performance
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202503-0279",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2312.0009"
},
{
"model": "tecnomatix plant simulation",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2302.0"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2312.0"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.3.0.13"
},
{
"model": "tecnomatix plant simulation",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2302.0021"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2412.0"
},
{
"model": "tecnomatix plant simulation",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2404.0010"
},
{
"model": "tecnomatix plant simulation",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2404.0"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2406.0"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2412.0002"
},
{
"model": "teamcenter visualization",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.0.0"
},
{
"model": "teamcenter visualization",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2406.0007"
},
{
"model": "tecnomatix plant simulation",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "teamcenter visualization",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "teamcenter visualization",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v14.3\u003c14.3.0.13"
},
{
"model": "teamcenter visualization",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v2312\u003c2312.0009"
},
{
"model": "teamcenter visualization",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v2406\u003c2406.0007"
},
{
"model": "teamcenter visualization",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v2412\u003c2412.0002"
},
{
"model": "tecnomatix plant simulation",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v2302\u003c2302.0021"
},
{
"model": "tecnomatix plant simulation",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v2404\u003c2404.0010"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09523"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014754"
},
{
"db": "NVD",
"id": "CVE-2025-23402"
}
]
},
"cve": "CVE-2025-23402",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2025-09523",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "productcert@siemens.com",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2025-23402",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-014754",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "productcert@siemens.com",
"id": "CVE-2025-23402",
"trust": 1.0,
"value": "High"
},
{
"author": "OTHER",
"id": "JVNDB-2025-014754",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-09523",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09523"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014754"
},
{
"db": "NVD",
"id": "CVE-2025-23402"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.13), Teamcenter Visualization V2312 (All versions \u003c V2312.0009), Teamcenter Visualization V2406 (All versions \u003c V2406.0007), Teamcenter Visualization V2412 (All versions \u003c V2412.0002), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0021), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. \r\nAn attacker could leverage this vulnerability to execute code in the context of the current process. Siemens\u0027 Teamcenter Visualization and Tecnomatix Plant Simulation Exists in a vulnerability related to the use of freed memory.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens Teamcenter Visualization is a software that provides team collaboration capabilities for designing 2D and 3D scenes. The software simplifies engineering and manufacturing processes by creating virtual prototypes from a variety of mechanical computer-aided design (MCAD) formats. Siemens Tecnomatix Plant Simulation is an industrial control device. Use the power of discrete event simulation to analyze and optimize production volume, thereby improving manufacturing system performance",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-23402"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014754"
},
{
"db": "CNVD",
"id": "CNVD-2025-09523"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-23402",
"trust": 3.2
},
{
"db": "SIEMENS",
"id": "SSA-050438",
"trust": 2.4
},
{
"db": "ICS CERT",
"id": "ICSA-25-072-01",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU92252869",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014754",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-09523",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09523"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014754"
},
{
"db": "NVD",
"id": "CVE-2025-23402"
}
]
},
"id": "VAR-202503-0279",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09523"
}
],
"trust": 0.8745396
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09523"
}
]
},
"last_update_date": "2025-10-03T21:35:10.502000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Siemens Teamcenter Visualization and Siemens Tecnomatix Plant Simulation Resource Management Error Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/687611"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09523"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-416",
"trust": 1.0
},
{
"problemtype": "Use of freed memory (CWE-416) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014754"
},
{
"db": "NVD",
"id": "CVE-2025-23402"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu92252869/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-23402"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-072-01"
},
{
"trust": 0.6,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-050438.htmlhttps"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09523"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014754"
},
{
"db": "NVD",
"id": "CVE-2025-23402"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-09523"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014754"
},
{
"db": "NVD",
"id": "CVE-2025-23402"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09523"
},
{
"date": "2025-09-30T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-014754"
},
{
"date": "2025-03-11T10:15:17.680000",
"db": "NVD",
"id": "CVE-2025-23402"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09523"
},
{
"date": "2025-09-30T08:48:00",
"db": "JVNDB",
"id": "JVNDB-2025-014754"
},
{
"date": "2025-09-23T15:28:26.313000",
"db": "NVD",
"id": "CVE-2025-23402"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a0Teamcenter\u00a0Visualization\u00a0 and \u00a0Tecnomatix\u00a0Plant\u00a0Simulation\u00a0 Vulnerability in using free memory in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014754"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.