Search
Find a vulnerability
Search criteria
10 vulnerabilities found for Teamcenter V2512 by Siemens
CVE-2026-111497 (GCVE-0-2026-111497)
Vulnerability from nvd – Published: 2026-10-22 13:35 – Updated: 2026-11-18 18:32Title
Out-of-Bounds Write in Google Brotli Decoder
Summary
A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.
Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
Severity
SSVC
Exploitation: active
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-23 00:00 UTC
Assigner
References
24 references
Impacted products
76 products
| Vendor | Product | Version | |
|---|---|---|---|
| Brotli |
Affected:
1.0.3 , < 1.0.10
(semver)
Affected: 1.1.0 , < 1.1.1 (semver) Affected: 1.2.0 , < 1.2.1 (semver) |
||
| Siemens | blueplanet 100 NX3 M8 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | blueplanet 125 NX3 M10 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | blueplanet 87.0 TL3 – 165 TL3 (GEN1 / GEN2) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | blueplanet gridsave 100 – 165 TL3 (HV) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | blueplanet gridsave 92 – 137 TL3 (GEN1 / GEN2) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC family V8 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC family V9 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Gridscale X DSA |
Affected:
V5.3 , < V5.4
(custom)
|
|
| Siemens | Gridscale X PSS®E |
Affected:
0 , < V36.8.0
(custom)
|
|
| Siemens | Heliox Dual Port 60kW |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox Flex Pro |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Integrated PA Suite Tester |
Affected:
0 , < *
(custom)
|
|
| Siemens | SENTRON Powermanager V8 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SENTRON Powermanager V9 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SICAM PAS CC |
Affected:
V6.02 , < *
(custom)
|
|
| Siemens | SICAM SCC |
Affected:
V7.01 , < *
(custom)
|
|
| Siemens | SICHARGE FLEX |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICHARGE UC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Go |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Setup |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | VersiCharge AC Series |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | VersiCloud |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Cloud Connector Configurator |
Affected:
0 , < V1.24.3
(custom)
|
|
| Siemens | Common Configurator (CC on IEM) |
Affected:
0 , < *
(custom)
|
|
| Siemens | Common Configurator on Device (CC on Edge) |
Affected:
0 , < *
(custom)
|
|
| Siemens | Data Flow Monitoring |
Affected:
0 , < V3.0.18
(custom)
|
|
| Siemens | Databus Configurator |
Affected:
0 , < V4.0.1
(custom)
|
|
| Siemens | DataXess Configurator |
Affected:
0 , < V1.5.7
(custom)
|
|
| Siemens | Edge OPC UA Server Configurator |
Affected:
0 , < V2.3.10
(custom)
|
|
| Siemens | Flow Creator Configurator |
Affected:
0 , < V1.15.1
(custom)
|
|
| Siemens | Industrial Edge Hub |
Affected:
0 , < *
(custom)
|
|
| Siemens | Industrial Edge Management Cloud |
Affected:
0 , < *
(custom)
|
|
| Siemens | HyperLynx |
Affected:
0 , < *
(custom)
|
|
| Siemens | Innexis Architecture Native Acceleration 2026 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Insights Hub |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Connect Electronics |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Connect MOM |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Core |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Discrete |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Foundation |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Pharma |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Process |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Intelligence |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Intra Plant Logistics |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Quality |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter RDnL |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter X |
Affected:
0 , < *
(custom)
|
|
| Siemens | PADS Pro Essentials |
Affected:
0 , < *
(custom)
|
|
| Siemens | PADS Pro Student Edition |
Affected:
0 , < *
(custom)
|
50 of 76 products shown. All of them on the page of CVE-2026-111497.
Date Public
2026-02-27 07:50
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-111497",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-23T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-28T03:55:48.896Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497"
}
],
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2026-11-03T21:05:46.791Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://github.com/advisories/GHSA-9v8h-qqgm-4m35"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/23/25"
},
{
"url": "https://lists.debian.org/debian-lts-announce/2026/10/msg00049.html"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/24/6"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/26/12"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/26/13"
},
{
"url": "https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497"
},
{
"url": "https://broccoli2shell.com"
},
{
"url": "https://github.com/dotnet/announcements/issues/494"
},
{
"url": "https://github.com/google/brotli/releases/tag/v1.2.1"
},
{
"url": "https://github.com/google/brotli/releases/tag/v1.1.1"
},
{
"url": "https://github.com/google/brotli/releases/tag/v1.0.10"
},
{
"url": "https://patchtheplanet.org/brotli"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/26/16"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/11/03/2"
}
],
"title": "CVE Program Container",
"x_generator": {
"engine": "ADPogram 0.0.1"
}
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "blueplanet 100 NX3 M8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 100 NX3 M8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 125 NX3 M10",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet gridsave 100 \u2013 165 TL3 (HV)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet gridsave 92 \u2013 137 TL3 (GEN1 / GEN2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC family V8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC family V9",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Gridscale X DSA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.4",
"status": "affected",
"version": "V5.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Gridscale X PSS\u00aeE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Dual Port 60kW",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Flex Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Integrated PA Suite Tester",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SENTRON Powermanager V8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SENTRON Powermanager V9",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM PAS CC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V6.02",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM SCC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V7.01",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICHARGE FLEX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICHARGE UC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Setup",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "VersiCharge AC Series",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "VersiCloud",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Cloud Connector Configurator",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.24.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Common Configurator\u00a0(CC on IEM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Common Configurator on Device\u00a0(CC on Edge)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Data Flow Monitoring",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.18",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Databus Configurator",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DataXess Configurator",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.5.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Edge OPC UA Server Configurator",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Flow Creator Configurator",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.15.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Hub",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Management Cloud",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "HyperLynx",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Innexis Architecture Native Acceleration 2026",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Insights Hub",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Connect Electronics",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Connect MOM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Core",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Discrete",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Foundation",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Pharma",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Process",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intelligence",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intra Plant Logistics",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Quality",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter RDnL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Pro Essentials",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Pro Student Edition",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Professional",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PAVE360 Automotive 2026",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Process Preparation X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Executable Digital Twin",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Studio",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2506",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2606",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Designer",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Enterprise",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "COMOS Walkinside",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Project Server Web Administration Tool",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC BRAUMAT",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2 Update 5",
"status": "affected",
"version": "V8.2 Update 1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Profiling Tool",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC SISTAR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2 Update 5",
"status": "affected",
"version": "V8.2 Update 1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Companion",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC OA V3.20",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.20.17.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC OA V3.21",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.21.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified for Industrial Edge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified PC Runtime",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified SIQENCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7/V8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Administrator",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "User Management Component (UMC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.15.4.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-18T18:32:29.836Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-443410.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-045512.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-898633.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-678870.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-242944.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"packageName": "github.com/google/brotli",
"product": "Brotli",
"repo": "https://github.com/google/brotli",
"vendor": "Google",
"versions": [
{
"lessThan": "1.0.10",
"status": "affected",
"version": "1.0.3",
"versionType": "semver"
},
{
"lessThan": "1.1.1",
"status": "affected",
"version": "1.1.0",
"versionType": "semver"
},
{
"lessThan": "1.2.1",
"status": "affected",
"version": "1.2.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "OpenAI Codex Security - Khai Tran and Sylvie Mayer"
}
],
"datePublic": "2026-02-27T07:50:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA buffer overflow vulnerability in the Brotli decoder (\u003ccode\u003ec/dec/decode.c\u003c/code\u003e) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\u003cbr\u003e\u003cbr\u003e\u003c/p\u003e\u003cp\u003eUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.\u003cspan\u003e\u003c/span\u003e\u003c/p\u003e"
}
],
"value": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\n\n\n\n\n\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-252",
"description": "CWE-252 Unchecked Return Value",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-27T14:58:42.704Z",
"orgId": "14ed7db2-1595-443d-9d34-6215bf890778",
"shortName": "Google"
},
"references": [
{
"tags": [
"patch"
],
"url": "https://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---high"
},
{
"tags": [
"release-notes",
"third-party-advisory"
],
"url": "https://github.com/andybalholm/brotli/releases/tag/v1.2.7"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
}
],
"value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Out-of-Bounds Write in Google Brotli Decoder",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "14ed7db2-1595-443d-9d34-6215bf890778",
"assignerShortName": "Google",
"cveId": "CVE-2026-111497",
"datePublished": "2026-10-22T13:35:41.975Z",
"dateReserved": "2026-10-16T09:58:17.790Z",
"dateUpdated": "2026-11-18T18:32:29.836Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-58113 (GCVE-0-2026-58113)
Vulnerability from nvd – Published: 2026-09-08 08:11 – Updated: 2026-09-09 15:25
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Teamcenter V2412 (All versions < V2412.0013), Teamcenter V2506 (All versions < V2506.0010), Teamcenter V2512 (All versions < V2512.2607), Teamcenter V2606 (All versions < V2606.2607). Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (/auth/ endpoint).
This could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim's Teamcenter session.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-09 15:25 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
1 reference
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Teamcenter V2412 |
Affected:
0 , < V2412.0013
(custom)
|
|
| Siemens | Teamcenter V2506 |
Affected:
0 , < V2506.0010
(custom)
|
|
| Siemens | Teamcenter V2512 |
Affected:
0 , < V2512.2607
(custom)
|
|
| Siemens | Teamcenter V2606 |
Affected:
0 , < V2606.2607
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-58113",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-09T15:25:24.743406Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-09T15:25:34.439Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0013",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2506",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512.2607",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2606",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2606.2607",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter V2412 (All versions \u003c V2412.0013), Teamcenter V2506 (All versions \u003c V2506.0010), Teamcenter V2512 (All versions \u003c V2512.2607), Teamcenter V2606 (All versions \u003c V2606.2607). Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (/auth/ endpoint).\r\nThis could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim\u0027s Teamcenter session."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:N/SC:L/SI:L/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:21.609Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-157465.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-58113",
"datePublished": "2026-09-08T08:11:21.609Z",
"dateReserved": "2026-06-29T11:49:12.097Z",
"dateUpdated": "2026-09-09T15:25:34.439Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-33893 (GCVE-0-2026-33893)
Vulnerability from nvd – Published: 2026-05-12 08:21 – Updated: 2026-05-12 13:25
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Teamcenter V2312 (All versions < V2312.0014), Teamcenter V2406 (All versions < V2406.0012), Teamcenter V2412 (All versions < V2412.0009), Teamcenter V2506 (All versions < V2506.0005), Teamcenter V2512 (All versions). The affected application contains hardcoded key which is used for obfuscation stored directly into the application.
This could allow an attacker to obtain these keys and misuse them to gain unauthorized access.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-12 13:25 UTC
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
1 reference
Impacted products
5 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Teamcenter V2312 |
Affected:
0 , < V2312.0014
(custom)
|
|
| Siemens | Teamcenter V2406 |
Affected:
0 , < V2406.0012
(custom)
|
|
| Siemens | Teamcenter V2412 |
Affected:
0 , < V2412.0009
(custom)
|
|
| Siemens | Teamcenter V2506 |
Affected:
0 , < V2506.0005
(custom)
|
|
| Siemens | Teamcenter V2512 |
Unaffected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-33893",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-12T13:25:24.360747Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T13:25:42.831Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0014",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0012",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2506",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter V2312 (All versions \u003c V2312.0014), Teamcenter V2406 (All versions \u003c V2406.0012), Teamcenter V2412 (All versions \u003c V2412.0009), Teamcenter V2506 (All versions \u003c V2506.0005), Teamcenter V2512 (All versions). The affected application contains hardcoded key which is used for obfuscation stored directly into the application.\r\nThis could allow an attacker to obtain these keys and misuse them to gain unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798: Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T08:21:15.796Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-827383.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-33893",
"datePublished": "2026-05-12T08:21:15.796Z",
"dateReserved": "2026-03-24T15:32:19.391Z",
"dateUpdated": "2026-05-12T13:25:42.831Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-33862 (GCVE-0-2026-33862)
Vulnerability from nvd – Published: 2026-05-12 08:21 – Updated: 2026-05-13 01:48
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Teamcenter V2312 (All versions < V2312.0014), Teamcenter V2406 (All versions < V2406.0012), Teamcenter V2412 (All versions < V2412.0009), Teamcenter V2506 (All versions < V2506.0005), Teamcenter V2512 (All versions). The affected application does not properly encode or filter user-supplied data. This could allow an attacker to inject malicious code that can be executed by other users when they visit the affected page.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-13 01:41 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
1 reference
Impacted products
5 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Teamcenter V2312 |
Affected:
0 , < V2312.0014
(custom)
|
|
| Siemens | Teamcenter V2406 |
Affected:
0 , < V2406.0012
(custom)
|
|
| Siemens | Teamcenter V2412 |
Affected:
0 , < V2412.0009
(custom)
|
|
| Siemens | Teamcenter V2506 |
Affected:
0 , < V2506.0005
(custom)
|
|
| Siemens | Teamcenter V2512 |
Unaffected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-33862",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-13T01:41:31.594862Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T01:48:31.646Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0014",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0012",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2506",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter V2312 (All versions \u003c V2312.0014), Teamcenter V2406 (All versions \u003c V2406.0012), Teamcenter V2412 (All versions \u003c V2412.0009), Teamcenter V2506 (All versions \u003c V2506.0005), Teamcenter V2512 (All versions). The affected application does not properly encode or filter user-supplied data. This could allow an attacker to inject malicious code that can be executed by other users when they visit the affected page."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T08:21:14.646Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-827383.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-33862",
"datePublished": "2026-05-12T08:21:14.646Z",
"dateReserved": "2026-03-24T12:34:25.562Z",
"dateUpdated": "2026-05-13T01:48:31.646Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-4367 (GCVE-0-2024-4367)
Vulnerability from nvd – Published: 2024-05-14 17:21 – Updated: 2026-05-12 11:30Summary
A type check was missing when handling fonts in PDF.js, which would allow arbitrary JavaScript execution in the PDF.js context. This vulnerability affects Firefox < 126, Firefox ESR < 115.11, and Thunderbird < 115.11.
Severity
5.6 (Medium)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-26 04:55 UTC
CWE
- Arbitrary JavaScript execution in PDF.js
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
12 references
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| Mozilla | Firefox |
Affected:
unspecified , < 126
(custom)
|
|
| Mozilla | Firefox ESR |
Affected:
unspecified , < 115.11
(custom)
|
|
| Mozilla | Thunderbird |
Affected:
unspecified , < 115.11
(custom)
|
|
| mozilla | thunderbird |
Affected:
0 , < 115.11
(custom)
cpe:2.3:a:mozilla:thunderbird:-:*:*:*:*:*:*:* |
|
| mozilla | firefox |
Affected:
0 , < 126
(custom)
cpe:2.3:a:mozilla:firefox:-:*:*:*:*:*:*:* |
|
| mozilla | firefox_esr |
Affected:
0 , < 115.11
(custom)
cpe:2.3:a:mozilla:firefox_esr:-:*:*:*:*:*:*:* |
|
| Siemens | Teamcenter V2312 |
Affected:
0 , < V2312.0009
(custom)
|
|
| Siemens | Teamcenter V2406 |
Affected:
0 , < V2406.0006
(custom)
|
|
| Siemens | Teamcenter V2512 |
Unaffected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:mozilla:thunderbird:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "thunderbird",
"vendor": "mozilla",
"versions": [
{
"lessThan": "115.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:mozilla:firefox:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "firefox",
"vendor": "mozilla",
"versions": [
{
"lessThan": "126",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:mozilla:firefox_esr:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "firefox_esr",
"vendor": "mozilla",
"versions": [
{
"lessThan": "115.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-4367",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T04:55:26.634778Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-13T14:44:59.422Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-04-24T18:19:17.818Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2024/Aug/30"
},
{
"url": "https://github.com/mozilla/pdf.js/releases/tag/v4.2.67"
},
{
"url": "https://codeanlabs.com/blog/research/cve-2024-4367-arbitrary-js-execution-in-pdf-js/"
},
{
"url": "https://github.com/gogs/gogs/issues/7928"
},
{
"url": "https://www.exploit-db.com/exploits/52273"
},
{
"tags": [
"x_transferred"
],
"url": "https://bugzilla.mozilla.org/show_bug.cgi?id=1893645"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.mozilla.org/security/advisories/mfsa2024-21/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.mozilla.org/security/advisories/mfsa2024-22/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.mozilla.org/security/advisories/mfsa2024-23/"
},
{
"tags": [
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2024/05/msg00010.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2024/05/msg00012.html"
}
],
"title": "CVE Program Container",
"x_generator": {
"engine": "ADPogram 0.0.1"
}
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0006",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T11:30:41.220Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-827383.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "Firefox",
"vendor": "Mozilla",
"versions": [
{
"lessThan": "126",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Firefox ESR",
"vendor": "Mozilla",
"versions": [
{
"lessThan": "115.11",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Thunderbird",
"vendor": "Mozilla",
"versions": [
{
"lessThan": "115.11",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Thomas Rinsma of Codean Labs"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A type check was missing when handling fonts in PDF.js, which would allow arbitrary JavaScript execution in the PDF.js context. This vulnerability affects Firefox \u003c 126, Firefox ESR \u003c 115.11, and Thunderbird \u003c 115.11."
}
],
"value": "A type check was missing when handling fonts in PDF.js, which would allow arbitrary JavaScript execution in the PDF.js context. This vulnerability affects Firefox \u003c 126, Firefox ESR \u003c 115.11, and Thunderbird \u003c 115.11."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Arbitrary JavaScript execution in PDF.js",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-10T16:07:35.289Z",
"orgId": "f16b083a-5664-49f3-a51e-8d479e5ed7fe",
"shortName": "mozilla"
},
"references": [
{
"url": "https://bugzilla.mozilla.org/show_bug.cgi?id=1893645"
},
{
"url": "https://www.mozilla.org/security/advisories/mfsa2024-21/"
},
{
"url": "https://www.mozilla.org/security/advisories/mfsa2024-22/"
},
{
"url": "https://www.mozilla.org/security/advisories/mfsa2024-23/"
},
{
"url": "https://lists.debian.org/debian-lts-announce/2024/05/msg00010.html"
},
{
"url": "https://lists.debian.org/debian-lts-announce/2024/05/msg00012.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "f16b083a-5664-49f3-a51e-8d479e5ed7fe",
"assignerShortName": "mozilla",
"cveId": "CVE-2024-4367",
"datePublished": "2024-05-14T17:21:23.486Z",
"dateReserved": "2024-04-30T19:08:43.037Z",
"dateUpdated": "2026-05-12T11:30:41.220Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-111497 (GCVE-0-2026-111497)
Vulnerability from cvelistv5 – Published: 2026-10-22 13:35 – Updated: 2026-11-18 18:32Title
Out-of-Bounds Write in Google Brotli Decoder
Summary
A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.
Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
Severity
SSVC
Exploitation: active
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-23 00:00 UTC
Assigner
References
24 references
Impacted products
76 products
| Vendor | Product | Version | |
|---|---|---|---|
| Brotli |
Affected:
1.0.3 , < 1.0.10
(semver)
Affected: 1.1.0 , < 1.1.1 (semver) Affected: 1.2.0 , < 1.2.1 (semver) |
||
| Siemens | blueplanet 100 NX3 M8 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | blueplanet 125 NX3 M10 |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | blueplanet 87.0 TL3 – 165 TL3 (GEN1 / GEN2) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | blueplanet gridsave 100 – 165 TL3 (HV) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | blueplanet gridsave 92 – 137 TL3 (GEN1 / GEN2) |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC family V8 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Desigo CC family V9 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Gridscale X DSA |
Affected:
V5.3 , < V5.4
(custom)
|
|
| Siemens | Gridscale X PSS®E |
Affected:
0 , < V36.8.0
(custom)
|
|
| Siemens | Heliox Dual Port 60kW |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Heliox Flex Pro |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Integrated PA Suite Tester |
Affected:
0 , < *
(custom)
|
|
| Siemens | SENTRON Powermanager V8 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SENTRON Powermanager V9 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SICAM PAS CC |
Affected:
V6.02 , < *
(custom)
|
|
| Siemens | SICAM SCC |
Affected:
V7.01 , < *
(custom)
|
|
| Siemens | SICHARGE FLEX |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | SICHARGE UC |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Go |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Sifinity Setup |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | VersiCharge AC Series |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | VersiCloud |
Unaffected:
0 , < *
(custom)
|
|
| Siemens | Cloud Connector Configurator |
Affected:
0 , < V1.24.3
(custom)
|
|
| Siemens | Common Configurator (CC on IEM) |
Affected:
0 , < *
(custom)
|
|
| Siemens | Common Configurator on Device (CC on Edge) |
Affected:
0 , < *
(custom)
|
|
| Siemens | Data Flow Monitoring |
Affected:
0 , < V3.0.18
(custom)
|
|
| Siemens | Databus Configurator |
Affected:
0 , < V4.0.1
(custom)
|
|
| Siemens | DataXess Configurator |
Affected:
0 , < V1.5.7
(custom)
|
|
| Siemens | Edge OPC UA Server Configurator |
Affected:
0 , < V2.3.10
(custom)
|
|
| Siemens | Flow Creator Configurator |
Affected:
0 , < V1.15.1
(custom)
|
|
| Siemens | Industrial Edge Hub |
Affected:
0 , < *
(custom)
|
|
| Siemens | Industrial Edge Management Cloud |
Affected:
0 , < *
(custom)
|
|
| Siemens | HyperLynx |
Affected:
0 , < *
(custom)
|
|
| Siemens | Innexis Architecture Native Acceleration 2026 |
Affected:
0 , < *
(custom)
|
|
| Siemens | Insights Hub |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Connect Electronics |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Connect MOM |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Core |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Discrete |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Foundation |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Pharma |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Execution Process |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Intelligence |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Intra Plant Logistics |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter Quality |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter RDnL |
Affected:
0 , < *
(custom)
|
|
| Siemens | Opcenter X |
Affected:
0 , < *
(custom)
|
|
| Siemens | PADS Pro Essentials |
Affected:
0 , < *
(custom)
|
|
| Siemens | PADS Pro Student Edition |
Affected:
0 , < *
(custom)
|
50 of 76 products shown. All of them on the page of CVE-2026-111497.
Date Public
2026-02-27 07:50
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-111497",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-23T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-28T03:55:48.896Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497"
}
],
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2026-11-03T21:05:46.791Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://github.com/advisories/GHSA-9v8h-qqgm-4m35"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/23/25"
},
{
"url": "https://lists.debian.org/debian-lts-announce/2026/10/msg00049.html"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/24/6"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/26/12"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/26/13"
},
{
"url": "https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497"
},
{
"url": "https://broccoli2shell.com"
},
{
"url": "https://github.com/dotnet/announcements/issues/494"
},
{
"url": "https://github.com/google/brotli/releases/tag/v1.2.1"
},
{
"url": "https://github.com/google/brotli/releases/tag/v1.1.1"
},
{
"url": "https://github.com/google/brotli/releases/tag/v1.0.10"
},
{
"url": "https://patchtheplanet.org/brotli"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/10/26/16"
},
{
"url": "http://www.openwall.com/lists/oss-security/2026/11/03/2"
}
],
"title": "CVE Program Container",
"x_generator": {
"engine": "ADPogram 0.0.1"
}
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "blueplanet 100 NX3 M8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 100 NX3 M8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 125 NX3 M10",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet gridsave 100 \u2013 165 TL3 (HV)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "blueplanet gridsave 92 \u2013 137 TL3 (GEN1 / GEN2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC family V8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Desigo CC family V9",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Gridscale X DSA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V5.4",
"status": "affected",
"version": "V5.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Gridscale X PSS\u00aeE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V36.8.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Dual Port 60kW",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Heliox Flex Pro",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Integrated PA Suite Tester",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SENTRON Powermanager V8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SENTRON Powermanager V9",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM PAS CC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V6.02",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICAM SCC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V7.01",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICHARGE FLEX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SICHARGE UC",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Go",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Sifinity Setup",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "VersiCharge AC Series",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "VersiCloud",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Cloud Connector Configurator",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.24.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Common Configurator\u00a0(CC on IEM)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Common Configurator on Device\u00a0(CC on Edge)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Data Flow Monitoring",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0.18",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Databus Configurator",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "DataXess Configurator",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.5.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Edge OPC UA Server Configurator",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.3.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Flow Creator Configurator",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.15.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Hub",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Management Cloud",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "HyperLynx",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Innexis Architecture Native Acceleration 2026",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Insights Hub",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Connect Electronics",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Connect MOM",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Core",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Discrete",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Foundation",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Pharma",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Execution Process",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intelligence",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Intra Plant Logistics",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter Quality",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter RDnL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Opcenter X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Pro Essentials",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Pro Student Edition",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PADS Professional",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "PAVE360 Automotive 2026",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Process Preparation X",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Executable Digital Twin",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Studio",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2506",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2606",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Designer",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Xpedition Enterprise",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "COMOS Walkinside",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Project Server Web Administration Tool",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC BRAUMAT",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2 Update 5",
"status": "affected",
"version": "V8.2 Update 1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Profiling Tool",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC SISTAR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V8.2 Update 5",
"status": "affected",
"version": "V8.2 Update 1",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Companion",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC OA V3.20",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.20.17.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC OA V3.21",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.21.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Runtime Professional",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified for Industrial Edge",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified PC Runtime",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC Unified SIQENCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinCC V7/V8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "TIA Administrator",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "User Management Component (UMC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.15.4.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-18T18:32:29.836Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-443410.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-045512.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-898633.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-678870.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-242944.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"packageName": "github.com/google/brotli",
"product": "Brotli",
"repo": "https://github.com/google/brotli",
"vendor": "Google",
"versions": [
{
"lessThan": "1.0.10",
"status": "affected",
"version": "1.0.3",
"versionType": "semver"
},
{
"lessThan": "1.1.1",
"status": "affected",
"version": "1.1.0",
"versionType": "semver"
},
{
"lessThan": "1.2.1",
"status": "affected",
"version": "1.2.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "OpenAI Codex Security - Khai Tran and Sylvie Mayer"
}
],
"datePublic": "2026-02-27T07:50:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA buffer overflow vulnerability in the Brotli decoder (\u003ccode\u003ec/dec/decode.c\u003c/code\u003e) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\u003cbr\u003e\u003cbr\u003e\u003c/p\u003e\u003cp\u003eUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.\u003cspan\u003e\u003c/span\u003e\u003c/p\u003e"
}
],
"value": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\n\n\n\n\n\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-252",
"description": "CWE-252 Unchecked Return Value",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-27T14:58:42.704Z",
"orgId": "14ed7db2-1595-443d-9d34-6215bf890778",
"shortName": "Google"
},
"references": [
{
"tags": [
"patch"
],
"url": "https://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---high"
},
{
"tags": [
"release-notes",
"third-party-advisory"
],
"url": "https://github.com/andybalholm/brotli/releases/tag/v1.2.7"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
}
],
"value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Out-of-Bounds Write in Google Brotli Decoder",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "14ed7db2-1595-443d-9d34-6215bf890778",
"assignerShortName": "Google",
"cveId": "CVE-2026-111497",
"datePublished": "2026-10-22T13:35:41.975Z",
"dateReserved": "2026-10-16T09:58:17.790Z",
"dateUpdated": "2026-11-18T18:32:29.836Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-58113 (GCVE-0-2026-58113)
Vulnerability from cvelistv5 – Published: 2026-09-08 08:11 – Updated: 2026-09-09 15:25
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Teamcenter V2412 (All versions < V2412.0013), Teamcenter V2506 (All versions < V2506.0010), Teamcenter V2512 (All versions < V2512.2607), Teamcenter V2606 (All versions < V2606.2607). Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (/auth/ endpoint).
This could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim's Teamcenter session.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-09 15:25 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
1 reference
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Teamcenter V2412 |
Affected:
0 , < V2412.0013
(custom)
|
|
| Siemens | Teamcenter V2506 |
Affected:
0 , < V2506.0010
(custom)
|
|
| Siemens | Teamcenter V2512 |
Affected:
0 , < V2512.2607
(custom)
|
|
| Siemens | Teamcenter V2606 |
Affected:
0 , < V2606.2607
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-58113",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-09T15:25:24.743406Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-09T15:25:34.439Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0013",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2506",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512.2607",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2606",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2606.2607",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter V2412 (All versions \u003c V2412.0013), Teamcenter V2506 (All versions \u003c V2506.0010), Teamcenter V2512 (All versions \u003c V2512.2607), Teamcenter V2606 (All versions \u003c V2606.2607). Affected applications do not properly encode user-supplied input reflected into HTML attribute contexts within the authentication redirect flow (/auth/ endpoint).\r\nThis could allow an unauthenticated remote attacker to inject arbitrary JavaScript into the browser of an authenticated user who loads a crafted URL, enabling the attacker to perform actions within the victim\u0027s Teamcenter session."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:N/SC:L/SI:L/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-08T08:11:21.609Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-157465.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-58113",
"datePublished": "2026-09-08T08:11:21.609Z",
"dateReserved": "2026-06-29T11:49:12.097Z",
"dateUpdated": "2026-09-09T15:25:34.439Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-33893 (GCVE-0-2026-33893)
Vulnerability from cvelistv5 – Published: 2026-05-12 08:21 – Updated: 2026-05-12 13:25
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Teamcenter V2312 (All versions < V2312.0014), Teamcenter V2406 (All versions < V2406.0012), Teamcenter V2412 (All versions < V2412.0009), Teamcenter V2506 (All versions < V2506.0005), Teamcenter V2512 (All versions). The affected application contains hardcoded key which is used for obfuscation stored directly into the application.
This could allow an attacker to obtain these keys and misuse them to gain unauthorized access.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-12 13:25 UTC
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
1 reference
Impacted products
5 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Teamcenter V2312 |
Affected:
0 , < V2312.0014
(custom)
|
|
| Siemens | Teamcenter V2406 |
Affected:
0 , < V2406.0012
(custom)
|
|
| Siemens | Teamcenter V2412 |
Affected:
0 , < V2412.0009
(custom)
|
|
| Siemens | Teamcenter V2506 |
Affected:
0 , < V2506.0005
(custom)
|
|
| Siemens | Teamcenter V2512 |
Unaffected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-33893",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-12T13:25:24.360747Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T13:25:42.831Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0014",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0012",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2506",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter V2312 (All versions \u003c V2312.0014), Teamcenter V2406 (All versions \u003c V2406.0012), Teamcenter V2412 (All versions \u003c V2412.0009), Teamcenter V2506 (All versions \u003c V2506.0005), Teamcenter V2512 (All versions). The affected application contains hardcoded key which is used for obfuscation stored directly into the application.\r\nThis could allow an attacker to obtain these keys and misuse them to gain unauthorized access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798: Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T08:21:15.796Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-827383.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-33893",
"datePublished": "2026-05-12T08:21:15.796Z",
"dateReserved": "2026-03-24T15:32:19.391Z",
"dateUpdated": "2026-05-12T13:25:42.831Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-33862 (GCVE-0-2026-33862)
Vulnerability from cvelistv5 – Published: 2026-05-12 08:21 – Updated: 2026-05-13 01:48
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Teamcenter V2312 (All versions < V2312.0014), Teamcenter V2406 (All versions < V2406.0012), Teamcenter V2412 (All versions < V2412.0009), Teamcenter V2506 (All versions < V2506.0005), Teamcenter V2512 (All versions). The affected application does not properly encode or filter user-supplied data. This could allow an attacker to inject malicious code that can be executed by other users when they visit the affected page.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-13 01:41 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
1 reference
Impacted products
5 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Teamcenter V2312 |
Affected:
0 , < V2312.0014
(custom)
|
|
| Siemens | Teamcenter V2406 |
Affected:
0 , < V2406.0012
(custom)
|
|
| Siemens | Teamcenter V2412 |
Affected:
0 , < V2412.0009
(custom)
|
|
| Siemens | Teamcenter V2506 |
Affected:
0 , < V2506.0005
(custom)
|
|
| Siemens | Teamcenter V2512 |
Unaffected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-33862",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-13T01:41:31.594862Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T01:48:31.646Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0014",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0012",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2506",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506.0005",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Teamcenter V2312 (All versions \u003c V2312.0014), Teamcenter V2406 (All versions \u003c V2406.0012), Teamcenter V2412 (All versions \u003c V2412.0009), Teamcenter V2506 (All versions \u003c V2506.0005), Teamcenter V2512 (All versions). The affected application does not properly encode or filter user-supplied data. This could allow an attacker to inject malicious code that can be executed by other users when they visit the affected page."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T08:21:14.646Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-827383.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-33862",
"datePublished": "2026-05-12T08:21:14.646Z",
"dateReserved": "2026-03-24T12:34:25.562Z",
"dateUpdated": "2026-05-13T01:48:31.646Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-4367 (GCVE-0-2024-4367)
Vulnerability from cvelistv5 – Published: 2024-05-14 17:21 – Updated: 2026-05-12 11:30Summary
A type check was missing when handling fonts in PDF.js, which would allow arbitrary JavaScript execution in the PDF.js context. This vulnerability affects Firefox < 126, Firefox ESR < 115.11, and Thunderbird < 115.11.
Severity
5.6 (Medium)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-26 04:55 UTC
CWE
- Arbitrary JavaScript execution in PDF.js
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
12 references
Impacted products
9 products
| Vendor | Product | Version | |
|---|---|---|---|
| Mozilla | Firefox |
Affected:
unspecified , < 126
(custom)
|
|
| Mozilla | Firefox ESR |
Affected:
unspecified , < 115.11
(custom)
|
|
| Mozilla | Thunderbird |
Affected:
unspecified , < 115.11
(custom)
|
|
| mozilla | thunderbird |
Affected:
0 , < 115.11
(custom)
cpe:2.3:a:mozilla:thunderbird:-:*:*:*:*:*:*:* |
|
| mozilla | firefox |
Affected:
0 , < 126
(custom)
cpe:2.3:a:mozilla:firefox:-:*:*:*:*:*:*:* |
|
| mozilla | firefox_esr |
Affected:
0 , < 115.11
(custom)
cpe:2.3:a:mozilla:firefox_esr:-:*:*:*:*:*:*:* |
|
| Siemens | Teamcenter V2312 |
Affected:
0 , < V2312.0009
(custom)
|
|
| Siemens | Teamcenter V2406 |
Affected:
0 , < V2406.0006
(custom)
|
|
| Siemens | Teamcenter V2512 |
Unaffected:
0 , < *
(custom)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:mozilla:thunderbird:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "thunderbird",
"vendor": "mozilla",
"versions": [
{
"lessThan": "115.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:mozilla:firefox:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "firefox",
"vendor": "mozilla",
"versions": [
{
"lessThan": "126",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:mozilla:firefox_esr:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "firefox_esr",
"vendor": "mozilla",
"versions": [
{
"lessThan": "115.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-4367",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T04:55:26.634778Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-13T14:44:59.422Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-04-24T18:19:17.818Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "http://seclists.org/fulldisclosure/2024/Aug/30"
},
{
"url": "https://github.com/mozilla/pdf.js/releases/tag/v4.2.67"
},
{
"url": "https://codeanlabs.com/blog/research/cve-2024-4367-arbitrary-js-execution-in-pdf-js/"
},
{
"url": "https://github.com/gogs/gogs/issues/7928"
},
{
"url": "https://www.exploit-db.com/exploits/52273"
},
{
"tags": [
"x_transferred"
],
"url": "https://bugzilla.mozilla.org/show_bug.cgi?id=1893645"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.mozilla.org/security/advisories/mfsa2024-21/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.mozilla.org/security/advisories/mfsa2024-22/"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.mozilla.org/security/advisories/mfsa2024-23/"
},
{
"tags": [
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2024/05/msg00010.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2024/05/msg00012.html"
}
],
"title": "CVE Program Container",
"x_generator": {
"engine": "ADPogram 0.0.1"
}
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "Teamcenter V2312",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2312.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2406",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2406.0006",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter V2512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "unaffected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T11:30:41.220Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-827383.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "Firefox",
"vendor": "Mozilla",
"versions": [
{
"lessThan": "126",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Firefox ESR",
"vendor": "Mozilla",
"versions": [
{
"lessThan": "115.11",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "Thunderbird",
"vendor": "Mozilla",
"versions": [
{
"lessThan": "115.11",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Thomas Rinsma of Codean Labs"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A type check was missing when handling fonts in PDF.js, which would allow arbitrary JavaScript execution in the PDF.js context. This vulnerability affects Firefox \u003c 126, Firefox ESR \u003c 115.11, and Thunderbird \u003c 115.11."
}
],
"value": "A type check was missing when handling fonts in PDF.js, which would allow arbitrary JavaScript execution in the PDF.js context. This vulnerability affects Firefox \u003c 126, Firefox ESR \u003c 115.11, and Thunderbird \u003c 115.11."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Arbitrary JavaScript execution in PDF.js",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-10T16:07:35.289Z",
"orgId": "f16b083a-5664-49f3-a51e-8d479e5ed7fe",
"shortName": "mozilla"
},
"references": [
{
"url": "https://bugzilla.mozilla.org/show_bug.cgi?id=1893645"
},
{
"url": "https://www.mozilla.org/security/advisories/mfsa2024-21/"
},
{
"url": "https://www.mozilla.org/security/advisories/mfsa2024-22/"
},
{
"url": "https://www.mozilla.org/security/advisories/mfsa2024-23/"
},
{
"url": "https://lists.debian.org/debian-lts-announce/2024/05/msg00010.html"
},
{
"url": "https://lists.debian.org/debian-lts-announce/2024/05/msg00012.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "f16b083a-5664-49f3-a51e-8d479e5ed7fe",
"assignerShortName": "mozilla",
"cveId": "CVE-2024-4367",
"datePublished": "2024-05-14T17:21:23.486Z",
"dateReserved": "2024-04-30T19:08:43.037Z",
"dateUpdated": "2026-05-12T11:30:41.220Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}