    CVE-2021-27382 (GCVE-0-2021-27382)

    Vulnerability from nvd – Published: 2021-04-22 20:42 – Updated: 2024-08-03 20:48
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13040)
    Severity
    No CVSS data available.
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All versions < SE2020MP13
    Create a notification for this product.
    Siemens Solid Edge SE2020 Affected: All versions < SE2020MP14
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP4
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:48:16.328Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-612/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c SE2020MP13"
                }
              ]
            },
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c SE2020MP14"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2020 (All versions \u003c SE2020MP14), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13040)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-06-08T19:47:16.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-612/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-27382",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c SE2020MP13"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c SE2020MP14"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2020 (All versions \u003c SE2020MP14), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13040)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-121: Stack-based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06",
                  "refsource": "CONFIRM",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-612/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-612/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-27382",
        "datePublished": "2021-04-22T20:42:21.000Z",
        "dateReserved": "2021-02-18T00:00:00.000Z",
        "dateUpdated": "2024-08-03T20:48:16.328Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-25678 (GCVE-0-2021-25678)

    Vulnerability from nvd – Published: 2021-04-22 20:42 – Updated: 2024-08-03 20:11
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12529)
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All versions < SE2020MP13
    Create a notification for this product.
    Siemens Solid Edge SE2020 Affected: All versions < SE2020MP14
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP4
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:11:27.826Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-611/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c SE2020MP13"
                }
              ]
            },
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c SE2020MP14"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2020 (All versions \u003c SE2020MP14), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12529)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-06-08T19:47:16.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-611/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-25678",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c SE2020MP13"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c SE2020MP14"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2020 (All versions \u003c SE2020MP14), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12529)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-787: Out-of-bounds Write"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-611/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-611/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-25678",
        "datePublished": "2021-04-22T20:42:21.000Z",
        "dateReserved": "2021-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-03T20:11:27.826Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-26997 (GCVE-0-2020-26997)

    Vulnerability from nvd – Published: 2021-04-22 20:42 – Updated: 2024-08-04 16:03
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)
    Severity
    No CVSS data available.
    CWE
    • CWE-822 - Untrusted Pointer Dereference
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All versions < SE2020MP13
    Create a notification for this product.
    Siemens Solid Edge SE2020 Affected: All versions < SE2020MP14
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP4
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:03:23.217Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c SE2020MP13"
                }
              ]
            },
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c SE2020MP14"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2020 (All versions \u003c SE2020MP14), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-822",
                  "description": "CWE-822: Untrusted Pointer Dereference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-06-08T19:47:15.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-26997",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c SE2020MP13"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c SE2020MP14"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2020 (All versions \u003c SE2020MP14), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-822: Untrusted Pointer Dereference"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-26997",
        "datePublished": "2021-04-22T20:42:19.000Z",
        "dateReserved": "2020-10-12T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:03:23.217Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-27381 (GCVE-0-2021-27381)

    Vulnerability from nvd – Published: 2021-03-15 17:03 – Updated: 2024-08-03 20:48
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All Versions < SE2020MP13
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP3
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:48:16.358Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2020MP13"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-22T20:42:21.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-27381",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2020MP13"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-125: Out-of-bounds Read"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-27381",
        "datePublished": "2021-03-15T17:03:31.000Z",
        "dateReserved": "2021-02-18T00:00:00.000Z",
        "dateUpdated": "2024-08-03T20:48:16.358Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-27380 (GCVE-0-2021-27380)

    Vulnerability from nvd – Published: 2021-03-15 17:03 – Updated: 2024-08-03 20:48
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All versions < SE2020MP13
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP4
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:48:16.376Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c SE2020MP13"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-06-08T19:47:16.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-27380",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c SE2020MP13"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-787: Out-of-bounds Write"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06",
                  "refsource": "CONFIRM",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-27380",
        "datePublished": "2021-03-15T17:03:31.000Z",
        "dateReserved": "2021-02-18T00:00:00.000Z",
        "dateUpdated": "2024-08-03T20:48:16.376Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-28387 (GCVE-0-2020-28387)

    Vulnerability from nvd – Published: 2021-03-15 17:03 – Updated: 2024-08-04 16:33
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)
    Severity
    No CVSS data available.
    CWE
    • CWE-611 - Improper Restriction of XML External Entity Reference
    Assigner
    References
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All Versions < SE2020MP13
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP3
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:33:59.035Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2020MP13"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611: Improper Restriction of XML External Entity Reference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-22T20:42:20.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-28387",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2020MP13"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-611: Improper Restriction of XML External Entity Reference"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-28387",
        "datePublished": "2021-03-15T17:03:30.000Z",
        "dateReserved": "2020-11-10T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:33:59.035Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-28385 (GCVE-0-2020-28385)

    Vulnerability from nvd – Published: 2021-03-15 17:03 – Updated: 2024-08-04 16:33
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All versions < SE2020MP13
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP4
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:33:59.024Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c SE2020MP13"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-22T20:42:20.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-28385",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c SE2020MP13"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-787: Out-of-bounds Write"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06",
                  "refsource": "CONFIRM",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-28385",
        "datePublished": "2021-03-15T17:03:30.000Z",
        "dateReserved": "2020-11-10T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:33:59.024Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-28386 (GCVE-0-2020-28386)

    Vulnerability from nvd – Published: 2021-01-12 20:18 – Updated: 2024-08-04 16:33
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All Versions < SE2020MP12
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP2
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:33:59.063Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-060/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-077/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2020MP12"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP2"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-02-09T15:38:20.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-060/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-077/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-28386",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2020MP12"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-787: Out-of-bounds Write"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-060/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-060/"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-077/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-077/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-28386",
        "datePublished": "2021-01-12T20:18:36.000Z",
        "dateReserved": "2020-11-10T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:33:59.063Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-28384 (GCVE-0-2020-28384)

    Vulnerability from nvd – Published: 2021-01-12 20:18 – Updated: 2024-08-04 16:33
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process.
    Severity
    No CVSS data available.
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All Versions < SE2020MP12
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP2
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:33:59.070Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-055/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-076/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2020MP12"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP2"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-02-09T15:38:20.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-055/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-076/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-28384",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2020MP12"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-121: Stack-based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-055/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-055/"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-076/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-076/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-28384",
        "datePublished": "2021-01-12T20:18:35.000Z",
        "dateReserved": "2020-11-10T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:33:59.070Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-28383 (GCVE-0-2020-28383)

    Vulnerability from nvd – Published: 2021-01-12 20:18 – Updated: 2024-08-04 16:33
    VLAI
    Summary
    A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing PAR files. This can result in an out of bounds write past the memory location that is a read only image address. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11885)
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:33:59.029Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-054/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-047/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-073/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "JT2Go",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V13.1.0.1"
                }
              ]
            },
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2020MP12"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP2"
                }
              ]
            },
            {
              "product": "Teamcenter Visualization",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V13.1.0.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0.1), Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2), Teamcenter Visualization (All versions \u003c V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing PAR files. This can result in an out of bounds write past the memory location that is a read only image address. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11885)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-05-19T13:51:25.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-054/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-047/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-073/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-28383",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "JT2Go",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V13.1.0.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2020MP12"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Teamcenter Visualization",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V13.1.0.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0.1), Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2), Teamcenter Visualization (All versions \u003c V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing PAR files. This can result in an out of bounds write past the memory location that is a read only image address. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11885)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-787: Out-of-bounds Write"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-054/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-054/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-047/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-047/"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-073/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-073/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-28383",
        "datePublished": "2021-01-12T20:18:35.000Z",
        "dateReserved": "2020-11-10T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:33:59.029Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-28382 (GCVE-0-2020-28382)

    Vulnerability from nvd – Published: 2021-01-12 20:18 – Updated: 2024-08-04 16:33
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in a out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All Versions < SE2020MP12
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP2
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:33:59.191Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-052/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-075/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2020MP12"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP2"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in a out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-02-09T15:38:20.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-052/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-075/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-28382",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2020MP12"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in a out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-787: Out-of-bounds Write"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-052/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-052/"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-075/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-075/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-28382",
        "datePublished": "2021-01-12T20:18:35.000Z",
        "dateReserved": "2020-11-10T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:33:59.191Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-28381 (GCVE-0-2020-28381)

    Vulnerability from nvd – Published: 2021-01-12 20:18 – Updated: 2024-08-04 16:33
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write into uninitialized memory. An attacker could leverage this vulnerability to execute code in the context of the current process.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All Versions < SE2020MP12
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP2
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:33:59.080Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-048/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-053/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-074/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2020MP12"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP2"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write into uninitialized memory. An attacker could leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-02-09T15:38:20.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-048/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-053/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-074/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-28381",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2020MP12"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write into uninitialized memory. An attacker could leverage this vulnerability to execute code in the context of the current process."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-787: Out-of-bounds Write"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-048/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-048/"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-053/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-053/"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-074/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-074/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-28381",
        "datePublished": "2021-01-12T20:18:35.000Z",
        "dateReserved": "2020-11-10T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:33:59.080Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-26989 (GCVE-0-2020-26989)

    Vulnerability from nvd – Published: 2021-01-12 20:18 – Updated: 2024-08-04 16:03
    VLAI
    Summary
    A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11892)
    Severity
    No CVSS data available.
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:03:23.242Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-050/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "JT2Go",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V13.1.0.1"
                }
              ]
            },
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2020MP12"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP2"
                }
              ]
            },
            {
              "product": "Teamcenter Visualization",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V13.1.0.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0.1), Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2), Teamcenter Visualization (All versions \u003c V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11892)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-05-19T13:51:24.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-050/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-26989",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "JT2Go",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V13.1.0.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2020MP12"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Teamcenter Visualization",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V13.1.0.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0.1), Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2), Teamcenter Visualization (All versions \u003c V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11892)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-121: Stack-based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-050/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-050/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-26989",
        "datePublished": "2021-01-12T20:18:34.000Z",
        "dateReserved": "2020-10-12T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:03:23.242Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-27382 (GCVE-0-2021-27382)

    Vulnerability from cvelistv5 – Published: 2021-04-22 20:42 – Updated: 2024-08-03 20:48
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13040)
    Severity
    No CVSS data available.
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All versions < SE2020MP13
    Create a notification for this product.
    Siemens Solid Edge SE2020 Affected: All versions < SE2020MP14
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP4
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:48:16.328Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-612/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c SE2020MP13"
                }
              ]
            },
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c SE2020MP14"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2020 (All versions \u003c SE2020MP14), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13040)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-06-08T19:47:16.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-612/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-27382",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c SE2020MP13"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c SE2020MP14"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2020 (All versions \u003c SE2020MP14), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13040)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-121: Stack-based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06",
                  "refsource": "CONFIRM",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-612/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-612/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-27382",
        "datePublished": "2021-04-22T20:42:21.000Z",
        "dateReserved": "2021-02-18T00:00:00.000Z",
        "dateUpdated": "2024-08-03T20:48:16.328Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-25678 (GCVE-0-2021-25678)

    Vulnerability from cvelistv5 – Published: 2021-04-22 20:42 – Updated: 2024-08-03 20:11
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12529)
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All versions < SE2020MP13
    Create a notification for this product.
    Siemens Solid Edge SE2020 Affected: All versions < SE2020MP14
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP4
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:11:27.826Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-611/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c SE2020MP13"
                }
              ]
            },
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c SE2020MP14"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2020 (All versions \u003c SE2020MP14), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12529)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-06-08T19:47:16.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-611/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-25678",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c SE2020MP13"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c SE2020MP14"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2020 (All versions \u003c SE2020MP14), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12529)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-787: Out-of-bounds Write"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-611/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-611/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-25678",
        "datePublished": "2021-04-22T20:42:21.000Z",
        "dateReserved": "2021-01-21T00:00:00.000Z",
        "dateUpdated": "2024-08-03T20:11:27.826Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-26997 (GCVE-0-2020-26997)

    Vulnerability from cvelistv5 – Published: 2021-04-22 20:42 – Updated: 2024-08-04 16:03
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)
    Severity
    No CVSS data available.
    CWE
    • CWE-822 - Untrusted Pointer Dereference
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All versions < SE2020MP13
    Create a notification for this product.
    Siemens Solid Edge SE2020 Affected: All versions < SE2020MP14
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP4
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:03:23.217Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c SE2020MP13"
                }
              ]
            },
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c SE2020MP14"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2020 (All versions \u003c SE2020MP14), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-822",
                  "description": "CWE-822: Untrusted Pointer Dereference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-06-08T19:47:15.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-26997",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c SE2020MP13"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c SE2020MP14"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2020 (All versions \u003c SE2020MP14), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-822: Untrusted Pointer Dereference"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-26997",
        "datePublished": "2021-04-22T20:42:19.000Z",
        "dateReserved": "2020-10-12T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:03:23.217Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-27380 (GCVE-0-2021-27380)

    Vulnerability from cvelistv5 – Published: 2021-03-15 17:03 – Updated: 2024-08-03 20:48
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All versions < SE2020MP13
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP4
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:48:16.376Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c SE2020MP13"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-06-08T19:47:16.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-27380",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c SE2020MP13"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12532)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-787: Out-of-bounds Write"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06",
                  "refsource": "CONFIRM",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-27380",
        "datePublished": "2021-03-15T17:03:31.000Z",
        "dateReserved": "2021-02-18T00:00:00.000Z",
        "dateUpdated": "2024-08-03T20:48:16.376Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-27381 (GCVE-0-2021-27381)

    Vulnerability from cvelistv5 – Published: 2021-03-15 17:03 – Updated: 2024-08-03 20:48
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All Versions < SE2020MP13
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP3
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T20:48:16.358Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2020MP13"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-22T20:42:21.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2021-27381",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2020MP13"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12534)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-125: Out-of-bounds Read"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2021-27381",
        "datePublished": "2021-03-15T17:03:31.000Z",
        "dateReserved": "2021-02-18T00:00:00.000Z",
        "dateUpdated": "2024-08-03T20:48:16.358Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-28385 (GCVE-0-2020-28385)

    Vulnerability from cvelistv5 – Published: 2021-03-15 17:03 – Updated: 2024-08-04 16:33
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All versions < SE2020MP13
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP4
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:33:59.024Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c SE2020MP13"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-22T20:42:20.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-28385",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c SE2020MP13"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP4"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-787: Out-of-bounds Write"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06",
                  "refsource": "CONFIRM",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-28385",
        "datePublished": "2021-03-15T17:03:30.000Z",
        "dateReserved": "2020-11-10T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:33:59.024Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-28387 (GCVE-0-2020-28387)

    Vulnerability from cvelistv5 – Published: 2021-03-15 17:03 – Updated: 2024-08-04 16:33
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)
    Severity
    No CVSS data available.
    CWE
    • CWE-611 - Improper Restriction of XML External Entity Reference
    Assigner
    References
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All Versions < SE2020MP13
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP3
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:33:59.035Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2020MP13"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP3"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611: Improper Restriction of XML External Entity Reference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-04-22T20:42:20.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-28387",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2020MP13"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP3"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3). When opening a specially crafted SEECTCXML file, the application could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external dtd. (ZDI-CAN-11923)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-611: Improper Restriction of XML External Entity Reference"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-28387",
        "datePublished": "2021-03-15T17:03:30.000Z",
        "dateReserved": "2020-11-10T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:33:59.035Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-28386 (GCVE-0-2020-28386)

    Vulnerability from cvelistv5 – Published: 2021-01-12 20:18 – Updated: 2024-08-04 16:33
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All Versions < SE2020MP12
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP2
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:33:59.063Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-060/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-077/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2020MP12"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP2"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-02-09T15:38:20.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-060/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-077/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-28386",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2020MP12"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-787: Out-of-bounds Write"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-060/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-060/"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-077/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-077/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-28386",
        "datePublished": "2021-01-12T20:18:36.000Z",
        "dateReserved": "2020-11-10T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:33:59.063Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-28382 (GCVE-0-2020-28382)

    Vulnerability from cvelistv5 – Published: 2021-01-12 20:18 – Updated: 2024-08-04 16:33
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in a out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All Versions < SE2020MP12
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP2
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:33:59.191Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-052/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-075/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2020MP12"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP2"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in a out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-02-09T15:38:20.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-052/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-075/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-28382",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2020MP12"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in a out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-787: Out-of-bounds Write"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-052/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-052/"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-075/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-075/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-28382",
        "datePublished": "2021-01-12T20:18:35.000Z",
        "dateReserved": "2020-11-10T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:33:59.191Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-28381 (GCVE-0-2020-28381)

    Vulnerability from cvelistv5 – Published: 2021-01-12 20:18 – Updated: 2024-08-04 16:33
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write into uninitialized memory. An attacker could leverage this vulnerability to execute code in the context of the current process.
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All Versions < SE2020MP12
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP2
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:33:59.080Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-048/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-053/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-074/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2020MP12"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP2"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write into uninitialized memory. An attacker could leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-02-09T15:38:20.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-048/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-053/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-074/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-28381",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2020MP12"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write into uninitialized memory. An attacker could leverage this vulnerability to execute code in the context of the current process."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-787: Out-of-bounds Write"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-048/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-048/"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-053/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-053/"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-074/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-074/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-28381",
        "datePublished": "2021-01-12T20:18:35.000Z",
        "dateReserved": "2020-11-10T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:33:59.080Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-28384 (GCVE-0-2020-28384)

    Vulnerability from cvelistv5 – Published: 2021-01-12 20:18 – Updated: 2024-08-04 16:33
    VLAI
    Summary
    A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process.
    Severity
    No CVSS data available.
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Impacted products
    Vendor Product Version
    Siemens Solid Edge SE2020 Affected: All Versions < SE2020MP12
    Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All Versions < SE2021MP2
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:33:59.070Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-055/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-076/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2020MP12"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP2"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-02-09T15:38:20.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-055/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-076/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-28384",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2020MP12"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP2"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-121: Stack-based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-055/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-055/"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-076/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-076/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-28384",
        "datePublished": "2021-01-12T20:18:35.000Z",
        "dateReserved": "2020-11-10T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:33:59.070Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-28383 (GCVE-0-2020-28383)

    Vulnerability from cvelistv5 – Published: 2021-01-12 20:18 – Updated: 2024-08-04 16:33
    VLAI
    Summary
    A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing PAR files. This can result in an out of bounds write past the memory location that is a read only image address. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11885)
    Severity
    No CVSS data available.
    CWE
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:33:59.029Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-054/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-047/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-073/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "JT2Go",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V13.1.0.1"
                }
              ]
            },
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2020MP12"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP2"
                }
              ]
            },
            {
              "product": "Teamcenter Visualization",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V13.1.0.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0.1), Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2), Teamcenter Visualization (All versions \u003c V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing PAR files. This can result in an out of bounds write past the memory location that is a read only image address. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11885)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787: Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-05-19T13:51:25.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-054/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-047/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-073/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-28383",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "JT2Go",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V13.1.0.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2020MP12"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Teamcenter Visualization",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V13.1.0.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0.1), Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2), Teamcenter Visualization (All versions \u003c V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing PAR files. This can result in an out of bounds write past the memory location that is a read only image address. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11885)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-787: Out-of-bounds Write"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-054/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-054/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
                },
                {
                  "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04",
                  "refsource": "MISC",
                  "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-047/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-047/"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-073/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-073/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-28383",
        "datePublished": "2021-01-12T20:18:35.000Z",
        "dateReserved": "2020-11-10T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:33:59.029Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-26989 (GCVE-0-2020-26989)

    Vulnerability from cvelistv5 – Published: 2021-01-12 20:18 – Updated: 2024-08-04 16:03
    VLAI
    Summary
    A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11892)
    Severity
    No CVSS data available.
    CWE
    • CWE-121 - Stack-based Buffer Overflow
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T16:03:23.242Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-050/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "JT2Go",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V13.1.0.1"
                }
              ]
            },
            {
              "product": "Solid Edge SE2020",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2020MP12"
                }
              ]
            },
            {
              "product": "Solid Edge SE2021",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All Versions \u003c SE2021MP2"
                }
              ]
            },
            {
              "product": "Teamcenter Visualization",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V13.1.0.1"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0.1), Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2), Teamcenter Visualization (All versions \u003c V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11892)"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "CWE-121: Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-05-19T13:51:24.000Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-050/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "productcert@siemens.com",
              "ID": "CVE-2020-26989",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "JT2Go",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V13.1.0.1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2020",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2020MP12"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Solid Edge SE2021",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All Versions \u003c SE2021MP2"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Teamcenter Visualization",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "All versions \u003c V13.1.0.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Siemens"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.1.0.1), Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2), Teamcenter Visualization (All versions \u003c V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11892)"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-121: Stack-based Buffer Overflow"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf",
                  "refsource": "MISC",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
                },
                {
                  "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-050/",
                  "refsource": "MISC",
                  "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-050/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2020-26989",
        "datePublished": "2021-01-12T20:18:34.000Z",
        "dateReserved": "2020-10-12T00:00:00.000Z",
        "dateUpdated": "2024-08-04T16:03:23.242Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }