Search
Find a vulnerability
Search criteria
17 vulnerabilities found for Simcenter Nastran by Siemens
CVE-2026-59086 (GCVE-0-2026-59086)
Vulnerability from nvd – Published: 2026-08-11 12:20 – Updated: 2026-08-13 09:28
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2606), Simcenter Nastran (All versions < V2606). The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-11 14:49 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Simcenter Femap |
Affected:
0 , < V2606
(custom)
|
|
| Siemens | Simcenter Nastran |
Affected:
0 , < V2606
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-59086",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-11T14:49:43.272762Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T14:49:55.062Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2606",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Nastran",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2606",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2606), Simcenter Nastran (All versions \u003c V2606). The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-13T09:28:24.875Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-069220.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-59086",
"datePublished": "2026-08-11T12:20:25.108Z",
"dateReserved": "2026-07-02T13:41:41.932Z",
"dateUpdated": "2026-08-13T09:28:24.875Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40945 (GCVE-0-2025-40945)
Vulnerability from nvd – Published: 2026-07-14 09:19 – Updated: 2026-07-14 12:16
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in COMOS V10.4.5 (All versions < V10.4.5.0.2), COMOS V10.6 (All versions < V10.6.1), Designcenter NX (All versions < V2512.7000), Simcenter 3D (All versions < V2512.7000), Simcenter Femap V2506 (All versions < V2506.0003), Simcenter Femap V2512 (All versions < V2512.0002), Simcenter Nastran (All versions < V2606), Simcenter STAR-CCM+ (All versions < V2606), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Teamcenter Visualization V2412 (All versions < V2412.0012), Teamcenter Visualization V2506 (All versions < V2506.0009), Teamcenter Visualization V2512 (All versions < V2512.2605), Tecnomatix Plant Simulation V2404 (All versions < V2404.0022), Tecnomatix Plant Simulation V2504 (All versions < V2504.0010), Tecnomatix Process Simulate (All versions < V2606). Untrusted search path in IAM Client SDK may allow an authenticated user to potentially enable escalation of privilege via local access.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-07-14 12:16 UTC
CWE
- CWE-426 - Untrusted Search Path
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | COMOS V10.4.5 |
Affected:
0 , < V10.4.5.0.2
(custom)
|
|
| Siemens | COMOS V10.6 |
Affected:
0 , < V10.6.1
(custom)
|
|
| Siemens | Designcenter NX |
Affected:
0 , < V2512.7000
(custom)
|
|
| Siemens | Simcenter 3D |
Affected:
0 , < V2512.7000
(custom)
|
|
| Siemens | Simcenter Femap V2506 |
Affected:
0 , < V2506.0003
(custom)
|
|
| Siemens | Simcenter Femap V2512 |
Affected:
0 , < V2512.0002
(custom)
|
|
| Siemens | Simcenter Nastran |
Affected:
0 , < V2606
(custom)
|
|
| Siemens | Simcenter STAR-CCM+ |
Affected:
0 , < V2606
(custom)
|
|
| Siemens | Solid Edge SE2025 |
Affected:
0 , < V225.0 Update 13
(custom)
|
|
| Siemens | Solid Edge SE2026 |
Affected:
0 , < V226.0 Update 04
(custom)
|
|
| Siemens | Teamcenter Visualization V2412 |
Affected:
0 , < V2412.0012
(custom)
|
|
| Siemens | Teamcenter Visualization V2506 |
Affected:
0 , < V2506.0009
(custom)
|
|
| Siemens | Teamcenter Visualization V2512 |
Affected:
0 , < V2512.2605
(custom)
|
|
| Siemens | Tecnomatix Plant Simulation V2404 |
Affected:
0 , < V2404.0022
(custom)
|
|
| Siemens | Tecnomatix Plant Simulation V2504 |
Affected:
0 , < V2504.0010
(custom)
|
|
| Siemens | Tecnomatix Process Simulate |
Affected:
0 , < V2606
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40945",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-14T12:16:50.783446Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T12:16:59.871Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "COMOS V10.4.5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.4.5.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "COMOS V10.6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.6.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter NX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512.7000",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter 3D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512.7000",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Femap V2506",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Femap V2512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Nastran",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2606",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter STAR-CCM+",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2606",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2025",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V225.0 Update 13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2026",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V226.0 Update 04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0012",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2506",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512.2605",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0022",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2504",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2504.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Process Simulate",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2606",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in COMOS V10.4.5 (All versions \u003c V10.4.5.0.2), COMOS V10.6 (All versions \u003c V10.6.1), Designcenter NX (All versions \u003c V2512.7000), Simcenter 3D (All versions \u003c V2512.7000), Simcenter Femap V2506 (All versions \u003c V2506.0003), Simcenter Femap V2512 (All versions \u003c V2512.0002), Simcenter Nastran (All versions \u003c V2606), Simcenter STAR-CCM+ (All versions \u003c V2606), Solid Edge SE2025 (All versions \u003c V225.0 Update 13), Solid Edge SE2026 (All versions \u003c V226.0 Update 04), Teamcenter Visualization V2412 (All versions \u003c V2412.0012), Teamcenter Visualization V2506 (All versions \u003c V2506.0009), Teamcenter Visualization V2512 (All versions \u003c V2512.2605), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0022), Tecnomatix Plant Simulation V2504 (All versions \u003c V2504.0010), Tecnomatix Process Simulate (All versions \u003c V2606). Untrusted search path in IAM Client SDK may allow an authenticated user to potentially enable escalation of privilege via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-426",
"description": "CWE-426: Untrusted Search Path",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T09:19:08.857Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-288252.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40945",
"datePublished": "2026-07-14T09:19:08.857Z",
"dateReserved": "2025-04-16T09:06:15.879Z",
"dateUpdated": "2026-07-14T12:16:59.871Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-23720 (GCVE-0-2026-23720)
Vulnerability from nvd – Published: 2026-02-10 09:58 – Updated: 2026-02-10 15:06
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-10 15:05 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Simcenter Femap |
Affected:
0 , < V2512
(custom)
|
|
| Siemens | Simcenter Nastran |
Affected:
0 , < V2512
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-23720",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-10T15:05:51.918882Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T15:06:28.914Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Nastran",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2512), Simcenter Nastran (All versions \u003c V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T09:58:53.024Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-965753.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-23720",
"datePublished": "2026-02-10T09:58:53.024Z",
"dateReserved": "2026-01-15T14:48:10.775Z",
"dateUpdated": "2026-02-10T15:06:28.914Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-23719 (GCVE-0-2026-23719)
Vulnerability from nvd – Published: 2026-02-10 09:58 – Updated: 2026-02-10 15:07
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-10 15:06 UTC
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Simcenter Femap |
Affected:
0 , < V2512
(custom)
|
|
| Siemens | Simcenter Nastran |
Affected:
0 , < V2512
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-23719",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-10T15:06:58.008498Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T15:07:14.343Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Nastran",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2512), Simcenter Nastran (All versions \u003c V2512). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T09:58:51.821Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-965753.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-23719",
"datePublished": "2026-02-10T09:58:51.821Z",
"dateReserved": "2026-01-15T14:48:10.775Z",
"dateUpdated": "2026-02-10T15:07:14.343Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-23718 (GCVE-0-2026-23718)
Vulnerability from nvd – Published: 2026-02-10 09:58 – Updated: 2026-02-10 15:11
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-10 15:10 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Simcenter Femap |
Affected:
0 , < V2512
(custom)
|
|
| Siemens | Simcenter Nastran |
Affected:
0 , < V2512
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-23718",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-10T15:10:07.693864Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T15:11:43.915Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Nastran",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2512), Simcenter Nastran (All versions \u003c V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T09:58:50.583Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-965753.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-23718",
"datePublished": "2026-02-10T09:58:50.583Z",
"dateReserved": "2026-01-15T14:48:10.775Z",
"dateUpdated": "2026-02-10T15:11:43.915Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-23717 (GCVE-0-2026-23717)
Vulnerability from nvd – Published: 2026-02-10 09:58 – Updated: 2026-02-10 15:24
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-10 15:24 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Simcenter Femap |
Affected:
0 , < V2512
(custom)
|
|
| Siemens | Simcenter Nastran |
Affected:
0 , < V2512
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-23717",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-10T15:24:30.474202Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T15:24:46.229Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Nastran",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2512), Simcenter Nastran (All versions \u003c V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T09:58:48.864Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-965753.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-23717",
"datePublished": "2026-02-10T09:58:48.864Z",
"dateReserved": "2026-01-15T14:48:10.775Z",
"dateUpdated": "2026-02-10T15:24:46.229Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-23716 (GCVE-0-2026-23716)
Vulnerability from nvd – Published: 2026-02-10 09:58 – Updated: 2026-02-10 15:26
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-10 15:26 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Simcenter Femap |
Affected:
0 , < V2512
(custom)
|
|
| Siemens | Simcenter Nastran |
Affected:
0 , < V2512
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-23716",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-10T15:26:26.368609Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T15:26:34.955Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Nastran",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2512), Simcenter Nastran (All versions \u003c V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T09:58:47.685Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-965753.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-23716",
"datePublished": "2026-02-10T09:58:47.685Z",
"dateReserved": "2026-01-15T14:48:10.775Z",
"dateUpdated": "2026-02-10T15:26:34.955Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-23715 (GCVE-0-2026-23715)
Vulnerability from nvd – Published: 2026-02-10 09:58 – Updated: 2026-02-10 19:54
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds write vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-10 19:53 UTC
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Simcenter Femap |
Affected:
0 , < V2512
(custom)
|
|
| Siemens | Simcenter Nastran |
Affected:
0 , < V2512
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-23715",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-10T19:53:55.667032Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T19:54:02.855Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Nastran",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2512), Simcenter Nastran (All versions \u003c V2512). The affected applications contains an out of bounds write vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T09:58:46.529Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-965753.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-23715",
"datePublished": "2026-02-10T09:58:46.529Z",
"dateReserved": "2026-01-15T14:48:10.774Z",
"dateUpdated": "2026-02-10T19:54:02.855Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-59086 (GCVE-0-2026-59086)
Vulnerability from cvelistv5 – Published: 2026-08-11 12:20 – Updated: 2026-08-13 09:28
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2606), Simcenter Nastran (All versions < V2606). The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-11 14:49 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Simcenter Femap |
Affected:
0 , < V2606
(custom)
|
|
| Siemens | Simcenter Nastran |
Affected:
0 , < V2606
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-59086",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-11T14:49:43.272762Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T14:49:55.062Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2606",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Nastran",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2606",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2606), Simcenter Nastran (All versions \u003c V2606). The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-13T09:28:24.875Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-069220.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-59086",
"datePublished": "2026-08-11T12:20:25.108Z",
"dateReserved": "2026-07-02T13:41:41.932Z",
"dateUpdated": "2026-08-13T09:28:24.875Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-40945 (GCVE-0-2025-40945)
Vulnerability from cvelistv5 – Published: 2026-07-14 09:19 – Updated: 2026-07-14 12:16
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in COMOS V10.4.5 (All versions < V10.4.5.0.2), COMOS V10.6 (All versions < V10.6.1), Designcenter NX (All versions < V2512.7000), Simcenter 3D (All versions < V2512.7000), Simcenter Femap V2506 (All versions < V2506.0003), Simcenter Femap V2512 (All versions < V2512.0002), Simcenter Nastran (All versions < V2606), Simcenter STAR-CCM+ (All versions < V2606), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Teamcenter Visualization V2412 (All versions < V2412.0012), Teamcenter Visualization V2506 (All versions < V2506.0009), Teamcenter Visualization V2512 (All versions < V2512.2605), Tecnomatix Plant Simulation V2404 (All versions < V2404.0022), Tecnomatix Plant Simulation V2504 (All versions < V2504.0010), Tecnomatix Process Simulate (All versions < V2606). Untrusted search path in IAM Client SDK may allow an authenticated user to potentially enable escalation of privilege via local access.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-07-14 12:16 UTC
CWE
- CWE-426 - Untrusted Search Path
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | COMOS V10.4.5 |
Affected:
0 , < V10.4.5.0.2
(custom)
|
|
| Siemens | COMOS V10.6 |
Affected:
0 , < V10.6.1
(custom)
|
|
| Siemens | Designcenter NX |
Affected:
0 , < V2512.7000
(custom)
|
|
| Siemens | Simcenter 3D |
Affected:
0 , < V2512.7000
(custom)
|
|
| Siemens | Simcenter Femap V2506 |
Affected:
0 , < V2506.0003
(custom)
|
|
| Siemens | Simcenter Femap V2512 |
Affected:
0 , < V2512.0002
(custom)
|
|
| Siemens | Simcenter Nastran |
Affected:
0 , < V2606
(custom)
|
|
| Siemens | Simcenter STAR-CCM+ |
Affected:
0 , < V2606
(custom)
|
|
| Siemens | Solid Edge SE2025 |
Affected:
0 , < V225.0 Update 13
(custom)
|
|
| Siemens | Solid Edge SE2026 |
Affected:
0 , < V226.0 Update 04
(custom)
|
|
| Siemens | Teamcenter Visualization V2412 |
Affected:
0 , < V2412.0012
(custom)
|
|
| Siemens | Teamcenter Visualization V2506 |
Affected:
0 , < V2506.0009
(custom)
|
|
| Siemens | Teamcenter Visualization V2512 |
Affected:
0 , < V2512.2605
(custom)
|
|
| Siemens | Tecnomatix Plant Simulation V2404 |
Affected:
0 , < V2404.0022
(custom)
|
|
| Siemens | Tecnomatix Plant Simulation V2504 |
Affected:
0 , < V2504.0010
(custom)
|
|
| Siemens | Tecnomatix Process Simulate |
Affected:
0 , < V2606
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40945",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-14T12:16:50.783446Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T12:16:59.871Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "COMOS V10.4.5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.4.5.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "COMOS V10.6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.6.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Designcenter NX",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512.7000",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter 3D",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512.7000",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Femap V2506",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506.0003",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Femap V2512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512.0002",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Nastran",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2606",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter STAR-CCM+",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2606",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2025",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V225.0 Update 13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2026",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V226.0 Update 04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2412",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2412.0012",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2506",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506.0009",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Teamcenter Visualization V2512",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512.2605",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2404",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2404.0022",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2504",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2504.0010",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Process Simulate",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2606",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in COMOS V10.4.5 (All versions \u003c V10.4.5.0.2), COMOS V10.6 (All versions \u003c V10.6.1), Designcenter NX (All versions \u003c V2512.7000), Simcenter 3D (All versions \u003c V2512.7000), Simcenter Femap V2506 (All versions \u003c V2506.0003), Simcenter Femap V2512 (All versions \u003c V2512.0002), Simcenter Nastran (All versions \u003c V2606), Simcenter STAR-CCM+ (All versions \u003c V2606), Solid Edge SE2025 (All versions \u003c V225.0 Update 13), Solid Edge SE2026 (All versions \u003c V226.0 Update 04), Teamcenter Visualization V2412 (All versions \u003c V2412.0012), Teamcenter Visualization V2506 (All versions \u003c V2506.0009), Teamcenter Visualization V2512 (All versions \u003c V2512.2605), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0022), Tecnomatix Plant Simulation V2504 (All versions \u003c V2504.0010), Tecnomatix Process Simulate (All versions \u003c V2606). Untrusted search path in IAM Client SDK may allow an authenticated user to potentially enable escalation of privilege via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-426",
"description": "CWE-426: Untrusted Search Path",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T09:19:08.857Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-288252.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40945",
"datePublished": "2026-07-14T09:19:08.857Z",
"dateReserved": "2025-04-16T09:06:15.879Z",
"dateUpdated": "2026-07-14T12:16:59.871Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-23720 (GCVE-0-2026-23720)
Vulnerability from cvelistv5 – Published: 2026-02-10 09:58 – Updated: 2026-02-10 15:06
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-10 15:05 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Simcenter Femap |
Affected:
0 , < V2512
(custom)
|
|
| Siemens | Simcenter Nastran |
Affected:
0 , < V2512
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-23720",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-10T15:05:51.918882Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T15:06:28.914Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Nastran",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2512), Simcenter Nastran (All versions \u003c V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T09:58:53.024Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-965753.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-23720",
"datePublished": "2026-02-10T09:58:53.024Z",
"dateReserved": "2026-01-15T14:48:10.775Z",
"dateUpdated": "2026-02-10T15:06:28.914Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-23719 (GCVE-0-2026-23719)
Vulnerability from cvelistv5 – Published: 2026-02-10 09:58 – Updated: 2026-02-10 15:07
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-10 15:06 UTC
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Simcenter Femap |
Affected:
0 , < V2512
(custom)
|
|
| Siemens | Simcenter Nastran |
Affected:
0 , < V2512
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-23719",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-10T15:06:58.008498Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T15:07:14.343Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Nastran",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2512), Simcenter Nastran (All versions \u003c V2512). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T09:58:51.821Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-965753.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-23719",
"datePublished": "2026-02-10T09:58:51.821Z",
"dateReserved": "2026-01-15T14:48:10.775Z",
"dateUpdated": "2026-02-10T15:07:14.343Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-23718 (GCVE-0-2026-23718)
Vulnerability from cvelistv5 – Published: 2026-02-10 09:58 – Updated: 2026-02-10 15:11
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-10 15:10 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Simcenter Femap |
Affected:
0 , < V2512
(custom)
|
|
| Siemens | Simcenter Nastran |
Affected:
0 , < V2512
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-23718",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-10T15:10:07.693864Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T15:11:43.915Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Nastran",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2512), Simcenter Nastran (All versions \u003c V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T09:58:50.583Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-965753.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-23718",
"datePublished": "2026-02-10T09:58:50.583Z",
"dateReserved": "2026-01-15T14:48:10.775Z",
"dateUpdated": "2026-02-10T15:11:43.915Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-23717 (GCVE-0-2026-23717)
Vulnerability from cvelistv5 – Published: 2026-02-10 09:58 – Updated: 2026-02-10 15:24
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-10 15:24 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Simcenter Femap |
Affected:
0 , < V2512
(custom)
|
|
| Siemens | Simcenter Nastran |
Affected:
0 , < V2512
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-23717",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-10T15:24:30.474202Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T15:24:46.229Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Nastran",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2512), Simcenter Nastran (All versions \u003c V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T09:58:48.864Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-965753.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-23717",
"datePublished": "2026-02-10T09:58:48.864Z",
"dateReserved": "2026-01-15T14:48:10.775Z",
"dateUpdated": "2026-02-10T15:24:46.229Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-23716 (GCVE-0-2026-23716)
Vulnerability from cvelistv5 – Published: 2026-02-10 09:58 – Updated: 2026-02-10 15:26
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-10 15:26 UTC
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Simcenter Femap |
Affected:
0 , < V2512
(custom)
|
|
| Siemens | Simcenter Nastran |
Affected:
0 , < V2512
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-23716",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-10T15:26:26.368609Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T15:26:34.955Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Nastran",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2512), Simcenter Nastran (All versions \u003c V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T09:58:47.685Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-965753.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-23716",
"datePublished": "2026-02-10T09:58:47.685Z",
"dateReserved": "2026-01-15T14:48:10.775Z",
"dateUpdated": "2026-02-10T15:26:34.955Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-23715 (GCVE-0-2026-23715)
Vulnerability from cvelistv5 – Published: 2026-02-10 09:58 – Updated: 2026-02-10 19:54
VLAI
EPSS
VEX
Summary
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds write vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-10 19:53 UTC
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Simcenter Femap |
Affected:
0 , < V2512
(custom)
|
|
| Siemens | Simcenter Nastran |
Affected:
0 , < V2512
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-23715",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-10T19:53:55.667032Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T19:54:02.855Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Nastran",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2512",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2512), Simcenter Nastran (All versions \u003c V2512). The affected applications contains an out of bounds write vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-10T09:58:46.529Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-965753.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2026-23715",
"datePublished": "2026-02-10T09:58:46.529Z",
"dateReserved": "2026-01-15T14:48:10.774Z",
"dateUpdated": "2026-02-10T19:54:02.855Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
VAR-202405-0216
Vulnerability from variot - Updated: 2025-10-10 20:52A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process. Siemens' Simcenter Femap and Simcenter Nastran Exists in a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Simcenter Nastran is a finite element method solver.
Siemens Simcenter Nastran has a stack buffer overflow vulnerability
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202405-0216",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simcenter femap",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2406.0000"
},
{
"model": "simcenter nastran",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2406.90"
},
{
"model": "simcenter nastran",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2306.0"
},
{
"model": "simcenter femap",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simcenter nastran",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simcenter nastran",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "2306"
},
{
"model": "simcenter nastran",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "2312"
},
{
"model": "simcenter nastran",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "2406"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23515"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-028599"
},
{
"db": "NVD",
"id": "CVE-2024-33577"
}
]
},
"cve": "CVE-2024-33577",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2024-23515",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "productcert@siemens.com",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2024-33577",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-028599",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "productcert@siemens.com",
"id": "CVE-2024-33577",
"trust": 1.0,
"value": "High"
},
{
"author": "OTHER",
"id": "JVNDB-2024-028599",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2024-23515",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23515"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-028599"
},
{
"db": "NVD",
"id": "CVE-2024-33577"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Simcenter Femap (All versions \u003c V2406). The affected applications contain a stack overflow vulnerability while parsing specially strings as argument for one of the application binaries. This could allow an attacker to execute code in the context of the current process. Siemens\u0027 Simcenter Femap and Simcenter Nastran Exists in a stack-based buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Simcenter Nastran is a finite element method solver. \n\nSiemens Simcenter Nastran has a stack buffer overflow vulnerability",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-33577"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-028599"
},
{
"db": "CNVD",
"id": "CNVD-2024-23515"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-33577",
"trust": 3.2
},
{
"db": "SIEMENS",
"id": "SSA-258494",
"trust": 2.4
},
{
"db": "SIEMENS",
"id": "SSA-064222",
"trust": 1.8
},
{
"db": "ICS CERT",
"id": "ICSA-24-137-05",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-24-193-04",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU99298639",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU90955260",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2024-028599",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-23515",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23515"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-028599"
},
{
"db": "NVD",
"id": "CVE-2024-33577"
}
]
},
"id": "VAR-202405-0216",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23515"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23515"
}
]
},
"last_update_date": "2025-10-10T20:52:32.056000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Siemens Simcenter Nastran Stack Buffer Overflow Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/547141"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23515"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-028599"
},
{
"db": "NVD",
"id": "CVE-2024-33577"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-258494.html"
},
{
"trust": 1.8,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-064222.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu90955260/"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu99298639/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-33577"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-137-05"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-04"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23515"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-028599"
},
{
"db": "NVD",
"id": "CVE-2024-33577"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-23515"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-028599"
},
{
"db": "NVD",
"id": "CVE-2024-33577"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-24T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-23515"
},
{
"date": "2025-10-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-028599"
},
{
"date": "2024-05-14T16:17:20.707000",
"db": "NVD",
"id": "CVE-2024-33577"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-23515"
},
{
"date": "2025-10-07T09:27:00",
"db": "JVNDB",
"id": "JVNDB-2024-028599"
},
{
"date": "2025-10-03T20:37:49.900000",
"db": "NVD",
"id": "CVE-2024-33577"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a0Simcenter\u00a0Femap\u00a0 and \u00a0Simcenter\u00a0Nastran\u00a0 Stack-based buffer overflow vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-028599"
}
],
"trust": 0.8
}
}