Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for Sante FFT Imaging by Santesoft

    CVE-2024-1696 (GCVE-0-2024-1696)

    Vulnerability from nvd – Published: 2024-03-11 16:51 – Updated: 2024-08-12 20:31
    VLAI
    Title
    Santesoft Sante FFT Imaging Out-of-bounds Write
    Summary
    In Santesoft Sante FFT Imaging versions 1.4.1 and prior once a user opens a malicious DCM file on affected FFT Imaging installations, a local attacker could perform an out-of-bounds write, which could allow for arbitrary code execution.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Santesoft Sante FFT Imaging Affected: 0 , ≤ 1.4.1 (custom)
    Create a notification for this product.
    santesoft fft_imaging Affected: 0 , ≤ 1.4.0 (custom)
        cpe:2.3:a:santesoft:fft_imaging:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-03-05 18:00
    Credits
    Michael Heinzl reported this vulnerability to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:48:21.673Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-065-01"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:santesoft:fft_imaging:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "fft_imaging",
                "vendor": "santesoft",
                "versions": [
                  {
                    "lessThanOrEqual": "1.4.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-1696",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-03-11T17:37:46.240070Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-12T20:31:28.073Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Sante FFT Imaging",
              "vendor": "Santesoft",
              "versions": [
                {
                  "lessThanOrEqual": "1.4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Michael Heinzl reported this vulnerability to CISA."
            }
          ],
          "datePublic": "2024-03-05T18:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIn Santesoft Sante FFT Imaging versions 1.4.1 and prior once a user opens a malicious DCM file on affected FFT Imaging installations, a local attacker could perform an out-of-bounds write, which could allow for arbitrary code execution.\u003c/span\u003e\n\n"
                }
              ],
              "value": "In Santesoft Sante FFT Imaging versions 1.4.1 and prior once a user opens a malicious DCM file on affected FFT Imaging installations, a local attacker could perform an out-of-bounds write, which could allow for arbitrary code execution.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-11T16:51:58.503Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-065-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSantesoft released an updated version of their product and recommends users update Sante FFT Imaging to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://santesoft.com/win/sante-fft-imaging/download.html\"\u003ev1.4.2\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\nSantesoft released an updated version of their product and recommends users update Sante FFT Imaging to  v1.4.2 https://santesoft.com/win/sante-fft-imaging/download.html \u00a0or later.\n\n\n"
            }
          ],
          "source": {
            "advisory": "ICSMA-24-065-01",
            "discovery": "EXTERNAL"
          },
          "title": "Santesoft Sante FFT Imaging Out-of-bounds Write",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-1696",
        "datePublished": "2024-03-11T16:51:58.503Z",
        "dateReserved": "2024-02-21T00:48:26.810Z",
        "dateUpdated": "2024-08-12T20:31:28.073Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-5059 (GCVE-0-2023-5059)

    Vulnerability from nvd – Published: 2023-10-19 17:27 – Updated: 2025-01-16 21:29
    VLAI
    Title
    Santesoft Sante FFT Imaging Out-of-bounds Read
    Summary
    Santesoft Sante FFT Imaging lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Santesoft Sante FFT Imaging Affected: 0 , ≤ v1.4.0 (custom)
    Create a notification for this product.
    Date Public
    2023-10-12 17:00
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T07:44:53.940Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-23-285-02"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-5059",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-16T21:20:18.747921Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-16T21:29:06.591Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Sante FFT Imaging",
              "vendor": "Santesoft",
              "versions": [
                {
                  "lessThanOrEqual": "v1.4.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2023-10-12T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSantesoft Sante FFT Imaging lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process.\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e"
                }
              ],
              "value": "\n\n\n\n\nSantesoft Sante FFT Imaging lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-19T17:27:16.081Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-23-285-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSantesoft has released an updated version of their product and recommends users update to Sante FFT Imaging to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://santesoft.com/win/sante-fft-imaging/download.html\"\u003ev1.4.1\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e.\u003c/span\u003e\n\n\n\n\u003cbr\u003e"
                }
              ],
              "value": "\n\n\nSantesoft has released an updated version of their product and recommends users update to Sante FFT Imaging to  v1.4.1 https://santesoft.com/win/sante-fft-imaging/download.html .\n\n\n\n\n"
            }
          ],
          "source": {
            "advisory": "ICSMA-23-285-02",
            "discovery": "EXTERNAL"
          },
          "title": "Santesoft Sante FFT Imaging Out-of-bounds Read",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-5059",
        "datePublished": "2023-10-19T17:27:16.081Z",
        "dateReserved": "2023-09-18T22:39:02.791Z",
        "dateUpdated": "2025-01-16T21:29:06.591Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-1696 (GCVE-0-2024-1696)

    Vulnerability from cvelistv5 – Published: 2024-03-11 16:51 – Updated: 2024-08-12 20:31
    VLAI
    Title
    Santesoft Sante FFT Imaging Out-of-bounds Write
    Summary
    In Santesoft Sante FFT Imaging versions 1.4.1 and prior once a user opens a malicious DCM file on affected FFT Imaging installations, a local attacker could perform an out-of-bounds write, which could allow for arbitrary code execution.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Santesoft Sante FFT Imaging Affected: 0 , ≤ 1.4.1 (custom)
    Create a notification for this product.
    santesoft fft_imaging Affected: 0 , ≤ 1.4.0 (custom)
        cpe:2.3:a:santesoft:fft_imaging:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-03-05 18:00
    Credits
    Michael Heinzl reported this vulnerability to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:48:21.673Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-065-01"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:santesoft:fft_imaging:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "fft_imaging",
                "vendor": "santesoft",
                "versions": [
                  {
                    "lessThanOrEqual": "1.4.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-1696",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-03-11T17:37:46.240070Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-12T20:31:28.073Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Sante FFT Imaging",
              "vendor": "Santesoft",
              "versions": [
                {
                  "lessThanOrEqual": "1.4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Michael Heinzl reported this vulnerability to CISA."
            }
          ],
          "datePublic": "2024-03-05T18:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIn Santesoft Sante FFT Imaging versions 1.4.1 and prior once a user opens a malicious DCM file on affected FFT Imaging installations, a local attacker could perform an out-of-bounds write, which could allow for arbitrary code execution.\u003c/span\u003e\n\n"
                }
              ],
              "value": "In Santesoft Sante FFT Imaging versions 1.4.1 and prior once a user opens a malicious DCM file on affected FFT Imaging installations, a local attacker could perform an out-of-bounds write, which could allow for arbitrary code execution.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-11T16:51:58.503Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-24-065-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSantesoft released an updated version of their product and recommends users update Sante FFT Imaging to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://santesoft.com/win/sante-fft-imaging/download.html\"\u003ev1.4.2\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or later.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\nSantesoft released an updated version of their product and recommends users update Sante FFT Imaging to  v1.4.2 https://santesoft.com/win/sante-fft-imaging/download.html \u00a0or later.\n\n\n"
            }
          ],
          "source": {
            "advisory": "ICSMA-24-065-01",
            "discovery": "EXTERNAL"
          },
          "title": "Santesoft Sante FFT Imaging Out-of-bounds Write",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-1696",
        "datePublished": "2024-03-11T16:51:58.503Z",
        "dateReserved": "2024-02-21T00:48:26.810Z",
        "dateUpdated": "2024-08-12T20:31:28.073Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-5059 (GCVE-0-2023-5059)

    Vulnerability from cvelistv5 – Published: 2023-10-19 17:27 – Updated: 2025-01-16 21:29
    VLAI
    Title
    Santesoft Sante FFT Imaging Out-of-bounds Read
    Summary
    Santesoft Sante FFT Imaging lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Santesoft Sante FFT Imaging Affected: 0 , ≤ v1.4.0 (custom)
    Create a notification for this product.
    Date Public
    2023-10-12 17:00
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T07:44:53.940Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-23-285-02"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-5059",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-16T21:20:18.747921Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-16T21:29:06.591Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Sante FFT Imaging",
              "vendor": "Santesoft",
              "versions": [
                {
                  "lessThanOrEqual": "v1.4.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2023-10-12T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSantesoft Sante FFT Imaging lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process.\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e"
                }
              ],
              "value": "\n\n\n\n\nSantesoft Sante FFT Imaging lacks proper validation of user-supplied data when parsing DICOM files. This could lead to an out-of-bounds read. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-19T17:27:16.081Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-23-285-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSantesoft has released an updated version of their product and recommends users update to Sante FFT Imaging to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://santesoft.com/win/sante-fft-imaging/download.html\"\u003ev1.4.1\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e.\u003c/span\u003e\n\n\n\n\u003cbr\u003e"
                }
              ],
              "value": "\n\n\nSantesoft has released an updated version of their product and recommends users update to Sante FFT Imaging to  v1.4.1 https://santesoft.com/win/sante-fft-imaging/download.html .\n\n\n\n\n"
            }
          ],
          "source": {
            "advisory": "ICSMA-23-285-02",
            "discovery": "EXTERNAL"
          },
          "title": "Santesoft Sante FFT Imaging Out-of-bounds Read",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2023-5059",
        "datePublished": "2023-10-19T17:27:16.081Z",
        "dateReserved": "2023-09-18T22:39:02.791Z",
        "dateUpdated": "2025-01-16T21:29:06.591Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }