Find a vulnerability
Search criteria
32 vulnerabilities found for Hue Bridge by Philips
CVE-2026-126980 (GCVE-0-2026-126980)
Vulnerability from nvd – Published: 2026-11-17 23:16 – Updated: 2026-11-18 17:27- CWE-203 - Observable Discrepancy
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-126980",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-18T17:27:01.963408Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-18T17:27:14.097Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-11-12T03:11:02.680Z",
"datePublic": "2026-11-13T20:16:12.926Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit Observable Discrepancy Information Disclosure Vulnerability. This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the HomeKit Authentication service, which listens on TCP port 8080 by default. When processing crafted pairing requests, the service discloses internal information via an observable discrepancy between possible responses. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-28470."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-203",
"description": "CWE-203: Observable Discrepancy",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T23:16:31.681Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-965",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-965/"
}
],
"source": {
"lang": "en",
"value": "Xilokar"
},
"title": "Philips Hue Bridge HomeKit Observable Discrepancy Information Disclosure Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-126980",
"datePublished": "2026-11-17T23:16:31.681Z",
"dateReserved": "2026-11-12T03:11:02.654Z",
"dateUpdated": "2026-11-18T17:27:14.097Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-126979 (GCVE-0-2026-126979)
Vulnerability from nvd – Published: 2026-11-17 23:16 – Updated: 2026-11-18 17:26- CWE-191 - Integer Underflow (Wrap or Wraparound)
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-126979",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-18T17:26:31.936812Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-18T17:26:43.891Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-11-12T03:10:53.896Z",
"datePublic": "2026-11-13T20:16:06.896Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit Accessory Protocol chacha20_decrypt Integer Underflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. When parsing pairing requests, the process does not properly validate user-supplied data, which can result in an integer underflow before writing to memory. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28332."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-191",
"description": "CWE-191: Integer Underflow (Wrap or Wraparound)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T23:16:23.713Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-964",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-964/"
}
],
"source": {
"lang": "en",
"value": "Sang Nguyen Thien (@gnas0x0018) and mistsu of Team ANHTUD"
},
"title": "Philips Hue Bridge HomeKit Accessory Protocol chacha20_decrypt Integer Underflow Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-126979",
"datePublished": "2026-11-17T23:16:23.713Z",
"dateReserved": "2026-11-12T03:10:53.870Z",
"dateUpdated": "2026-11-18T17:26:43.891Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-126978 (GCVE-0-2026-126978)
Vulnerability from nvd – Published: 2026-11-17 23:16 – Updated: 2026-11-18 17:26- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-126978",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-18T17:25:24.702818Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-18T17:26:09.225Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-11-12T03:10:45.663Z",
"datePublic": "2026-11-13T20:16:00.088Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge hap_pair_setup_handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. When parsing pairing requests, the process does not properly validate the length of user-supplied data prior to copying it to a fixed-length, heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28434."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T23:16:16.044Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-963",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-963/"
}
],
"source": {
"lang": "en",
"value": "Sang Nguyen Thien (@gnas0x0018) and mistsu of Team ANHTUD"
},
"title": "Philips Hue Bridge hap_pair_setup_handler Heap-based Buffer Overflow Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-126978",
"datePublished": "2026-11-17T23:16:16.044Z",
"dateReserved": "2026-11-12T03:10:45.637Z",
"dateUpdated": "2026-11-18T17:26:09.225Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-126977 (GCVE-0-2026-126977)
Vulnerability from nvd – Published: 2026-11-17 23:16 – Updated: 2026-11-18 17:24- CWE-1393 - Use of Default Password
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-126977",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-18T17:24:38.329674Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-18T17:24:57.930Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-11-12T03:10:37.066Z",
"datePublic": "2026-11-13T20:15:54.266Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit Pair-Setup Default Password Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the HomeKit Authentication service, which listens on TCP port 8080 by default. Crafted data in a pairing request can cause the device to allow authentication using a blank password. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28323."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1393",
"description": "CWE-1393: Use of Default Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T23:16:08.637Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-962",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-962/"
}
],
"source": {
"lang": "en",
"value": "Hank Chen (@hank0438) of InnoEdge Labs"
},
"title": "Philips Hue Bridge HomeKit Pair-Setup Default Password Authentication Bypass Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-126977",
"datePublished": "2026-11-17T23:16:08.637Z",
"dateReserved": "2026-11-12T03:10:37.038Z",
"dateUpdated": "2026-11-18T17:24:57.930Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3562 (GCVE-0-2026-3562)
Vulnerability from nvd – Published: 2026-03-13 20:37 – Updated: 2026-03-16 20:21- CWE-347 - Improper Verification of Cryptographic Signature
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3562",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:21:23.637688Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:21:33.688Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:57.414Z",
"datePublic": "2026-03-06T21:19:44.813Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge hk_hap Ed25519 Signature Verification Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the ed25519_sign_open function. The issue results from improper verification of a cryptographic signature. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28480."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-347",
"description": "CWE-347: Improper Verification of Cryptographic Signature",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:37:09.162Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-160",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-160/"
}
],
"source": {
"lang": "en",
"value": "Viettel Cyber Security"
},
"title": "Philips Hue Bridge hk_hap Ed25519 Signature Verification Authentication Bypass Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3562",
"datePublished": "2026-03-13T20:37:09.162Z",
"dateReserved": "2026-03-04T19:42:57.379Z",
"dateUpdated": "2026-03-16T20:21:33.688Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3561 (GCVE-0-2026-3561)
Vulnerability from nvd – Published: 2026-03-13 20:37 – Updated: 2026-03-16 20:21- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3561",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:20:49.680668Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:21:04.470Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:53.455Z",
"datePublic": "2026-03-06T21:19:38.258Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the handling of PUT requests to the characteristics endpoint. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28479."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:37:05.625Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-159",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-159/"
}
],
"source": {
"lang": "en",
"value": "Thalium team from Thales Group (@thalium_team)"
},
"title": "Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3561",
"datePublished": "2026-03-13T20:37:05.625Z",
"dateReserved": "2026-03-04T19:42:53.419Z",
"dateUpdated": "2026-03-16T20:21:04.470Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3560 (GCVE-0-2026-3560)
Vulnerability from nvd – Published: 2026-03-13 20:37 – Updated: 2026-03-16 20:20- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3560",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:20:11.397148Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:20:23.327Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:49.535Z",
"datePublic": "2026-03-06T21:19:32.778Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:37:01.412Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-158",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-158/"
}
],
"source": {
"lang": "en",
"value": "Xilokar (@xilokar@mamot.fr)"
},
"title": "Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3560",
"datePublished": "2026-03-13T20:37:01.412Z",
"dateReserved": "2026-03-04T19:42:49.491Z",
"dateUpdated": "2026-03-16T20:20:23.327Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3559 (GCVE-0-2026-3559)
Vulnerability from nvd – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:19- CWE-323 - Reusing a Nonce, Key Pair in Encryption
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3559",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:19:38.659046Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:19:49.916Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:45.919Z",
"datePublic": "2026-03-06T21:19:27.080Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of the SRP authentication mechanism in the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the use of a static nonce value. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28451."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-323",
"description": "CWE-323: Reusing a Nonce, Key Pair in Encryption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:36:57.441Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-157",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-157/"
}
],
"source": {
"lang": "en",
"value": "Ho Xuan Ninh (@Xuanninh1412) and Hoang Hai Long (@seadragnol) from Qrious Secure (@qriousec)"
},
"title": "Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3559",
"datePublished": "2026-03-13T20:36:57.441Z",
"dateReserved": "2026-03-04T19:42:45.880Z",
"dateUpdated": "2026-03-16T20:19:49.916Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3558 (GCVE-0-2026-3558)
Vulnerability from nvd – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:18- CWE-306 - Missing Authentication for Critical Function
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3558",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:18:31.279335Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:18:40.959Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:42.421Z",
"datePublic": "2026-03-06T21:19:21.476Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit Accessory Protocol Transient Pairing Mode Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28374."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:36:52.519Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-156",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-156/"
}
],
"source": {
"lang": "en",
"value": "Ho Xuan Ninh (@Xuanninh1412) and Hoang Hai Long (@seadragnol) from Qrious Secure (@qriousec)"
},
"title": "Philips Hue Bridge HomeKit Accessory Protocol Transient Pairing Mode Authentication Bypass Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3558",
"datePublished": "2026-03-13T20:36:52.519Z",
"dateReserved": "2026-03-04T19:42:42.383Z",
"dateUpdated": "2026-03-16T20:18:40.959Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3557 (GCVE-0-2026-3557)
Vulnerability from nvd – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:17- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3557",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:17:45.866601Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:17:59.717Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:37.503Z",
"datePublic": "2026-03-06T21:19:15.836Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge hap_pair_verify_handler Sub-TLV Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the hap_pair_verify_handler function of the hk_hap service, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-28337."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:36:48.632Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-155",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-155/"
}
],
"source": {
"lang": "en",
"value": "Viettel Cyber Security"
},
"title": "Philips Hue Bridge hap_pair_verify_handler Sub-TLV Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3557",
"datePublished": "2026-03-13T20:36:48.632Z",
"dateReserved": "2026-03-04T19:42:37.457Z",
"dateUpdated": "2026-03-16T20:17:59.717Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3556 (GCVE-0-2026-3556)
Vulnerability from nvd – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:17- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3556",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:16:52.038932Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:17:16.686Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:32.769Z",
"datePublic": "2026-03-06T21:19:09.676Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the hk_hap_pair_storage_put function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the HomeKit service. Was ZDI-CAN-28326."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:36:44.408Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-154",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-154/"
}
],
"source": {
"lang": "en",
"value": "InnoEdge Labs"
},
"title": "Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3556",
"datePublished": "2026-03-13T20:36:44.408Z",
"dateReserved": "2026-03-04T19:42:32.733Z",
"dateUpdated": "2026-03-16T20:17:16.686Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3555 (GCVE-0-2026-3555)
Vulnerability from nvd – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:16- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3555",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:15:51.424960Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:16:14.612Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:29.193Z",
"datePublic": "2026-03-06T21:19:00.069Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. User interaction is required to exploit this vulnerability in that the user must initiate the device pairing process.\n\nThe specific flaw exists within the handling of custom Zigbee ZCL frames in the Model Info download functionality. The issue results from the lack of proper validation of the size of data prior to copying it to a fixed-size heap buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28276."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:36:40.448Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-153",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-153/"
}
],
"source": {
"lang": "en",
"value": "Mehdi Talbi, Matthieu Breuil, Th\u00e9o Gordyjan from @Synacktiv"
},
"title": "Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3555",
"datePublished": "2026-03-13T20:36:40.448Z",
"dateReserved": "2026-03-04T19:42:29.133Z",
"dateUpdated": "2026-03-16T20:16:14.612Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-126980 (GCVE-0-2026-126980)
Vulnerability from cvelistv5 – Published: 2026-11-17 23:16 – Updated: 2026-11-18 17:27- CWE-203 - Observable Discrepancy
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-126980",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-18T17:27:01.963408Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-18T17:27:14.097Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-11-12T03:11:02.680Z",
"datePublic": "2026-11-13T20:16:12.926Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit Observable Discrepancy Information Disclosure Vulnerability. This vulnerability allows network-adjacent attackers to disclose sensitive information on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the HomeKit Authentication service, which listens on TCP port 8080 by default. When processing crafted pairing requests, the service discloses internal information via an observable discrepancy between possible responses. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-28470."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-203",
"description": "CWE-203: Observable Discrepancy",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T23:16:31.681Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-965",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-965/"
}
],
"source": {
"lang": "en",
"value": "Xilokar"
},
"title": "Philips Hue Bridge HomeKit Observable Discrepancy Information Disclosure Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-126980",
"datePublished": "2026-11-17T23:16:31.681Z",
"dateReserved": "2026-11-12T03:11:02.654Z",
"dateUpdated": "2026-11-18T17:27:14.097Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-126979 (GCVE-0-2026-126979)
Vulnerability from cvelistv5 – Published: 2026-11-17 23:16 – Updated: 2026-11-18 17:26- CWE-191 - Integer Underflow (Wrap or Wraparound)
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-126979",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-18T17:26:31.936812Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-18T17:26:43.891Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-11-12T03:10:53.896Z",
"datePublic": "2026-11-13T20:16:06.896Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit Accessory Protocol chacha20_decrypt Integer Underflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. When parsing pairing requests, the process does not properly validate user-supplied data, which can result in an integer underflow before writing to memory. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28332."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-191",
"description": "CWE-191: Integer Underflow (Wrap or Wraparound)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T23:16:23.713Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-964",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-964/"
}
],
"source": {
"lang": "en",
"value": "Sang Nguyen Thien (@gnas0x0018) and mistsu of Team ANHTUD"
},
"title": "Philips Hue Bridge HomeKit Accessory Protocol chacha20_decrypt Integer Underflow Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-126979",
"datePublished": "2026-11-17T23:16:23.713Z",
"dateReserved": "2026-11-12T03:10:53.870Z",
"dateUpdated": "2026-11-18T17:26:43.891Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-126978 (GCVE-0-2026-126978)
Vulnerability from cvelistv5 – Published: 2026-11-17 23:16 – Updated: 2026-11-18 17:26- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-126978",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-18T17:25:24.702818Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-18T17:26:09.225Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-11-12T03:10:45.663Z",
"datePublic": "2026-11-13T20:16:00.088Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge hap_pair_setup_handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. When parsing pairing requests, the process does not properly validate the length of user-supplied data prior to copying it to a fixed-length, heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28434."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T23:16:16.044Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-963",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-963/"
}
],
"source": {
"lang": "en",
"value": "Sang Nguyen Thien (@gnas0x0018) and mistsu of Team ANHTUD"
},
"title": "Philips Hue Bridge hap_pair_setup_handler Heap-based Buffer Overflow Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-126978",
"datePublished": "2026-11-17T23:16:16.044Z",
"dateReserved": "2026-11-12T03:10:45.637Z",
"dateUpdated": "2026-11-18T17:26:09.225Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-126977 (GCVE-0-2026-126977)
Vulnerability from cvelistv5 – Published: 2026-11-17 23:16 – Updated: 2026-11-18 17:24- CWE-1393 - Use of Default Password
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-126977",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-18T17:24:38.329674Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-18T17:24:57.930Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-11-12T03:10:37.066Z",
"datePublic": "2026-11-13T20:15:54.266Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit Pair-Setup Default Password Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the HomeKit Authentication service, which listens on TCP port 8080 by default. Crafted data in a pairing request can cause the device to allow authentication using a blank password. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28323."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1393",
"description": "CWE-1393: Use of Default Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-17T23:16:08.637Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-962",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-962/"
}
],
"source": {
"lang": "en",
"value": "Hank Chen (@hank0438) of InnoEdge Labs"
},
"title": "Philips Hue Bridge HomeKit Pair-Setup Default Password Authentication Bypass Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-126977",
"datePublished": "2026-11-17T23:16:08.637Z",
"dateReserved": "2026-11-12T03:10:37.038Z",
"dateUpdated": "2026-11-18T17:24:57.930Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3562 (GCVE-0-2026-3562)
Vulnerability from cvelistv5 – Published: 2026-03-13 20:37 – Updated: 2026-03-16 20:21- CWE-347 - Improper Verification of Cryptographic Signature
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3562",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:21:23.637688Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:21:33.688Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:57.414Z",
"datePublic": "2026-03-06T21:19:44.813Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge hk_hap Ed25519 Signature Verification Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the ed25519_sign_open function. The issue results from improper verification of a cryptographic signature. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28480."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-347",
"description": "CWE-347: Improper Verification of Cryptographic Signature",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:37:09.162Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-160",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-160/"
}
],
"source": {
"lang": "en",
"value": "Viettel Cyber Security"
},
"title": "Philips Hue Bridge hk_hap Ed25519 Signature Verification Authentication Bypass Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3562",
"datePublished": "2026-03-13T20:37:09.162Z",
"dateReserved": "2026-03-04T19:42:57.379Z",
"dateUpdated": "2026-03-16T20:21:33.688Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3561 (GCVE-0-2026-3561)
Vulnerability from cvelistv5 – Published: 2026-03-13 20:37 – Updated: 2026-03-16 20:21- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3561",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:20:49.680668Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:21:04.470Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:53.455Z",
"datePublic": "2026-03-06T21:19:38.258Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the handling of PUT requests to the characteristics endpoint. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28479."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:37:05.625Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-159",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-159/"
}
],
"source": {
"lang": "en",
"value": "Thalium team from Thales Group (@thalium_team)"
},
"title": "Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3561",
"datePublished": "2026-03-13T20:37:05.625Z",
"dateReserved": "2026-03-04T19:42:53.419Z",
"dateUpdated": "2026-03-16T20:21:04.470Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3560 (GCVE-0-2026-3560)
Vulnerability from cvelistv5 – Published: 2026-03-13 20:37 – Updated: 2026-03-16 20:20- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3560",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:20:11.397148Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:20:23.327Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:49.535Z",
"datePublic": "2026-03-06T21:19:32.778Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:37:01.412Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-158",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-158/"
}
],
"source": {
"lang": "en",
"value": "Xilokar (@xilokar@mamot.fr)"
},
"title": "Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3560",
"datePublished": "2026-03-13T20:37:01.412Z",
"dateReserved": "2026-03-04T19:42:49.491Z",
"dateUpdated": "2026-03-16T20:20:23.327Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3559 (GCVE-0-2026-3559)
Vulnerability from cvelistv5 – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:19- CWE-323 - Reusing a Nonce, Key Pair in Encryption
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3559",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:19:38.659046Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:19:49.916Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:45.919Z",
"datePublic": "2026-03-06T21:19:27.080Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of the SRP authentication mechanism in the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the use of a static nonce value. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28451."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-323",
"description": "CWE-323: Reusing a Nonce, Key Pair in Encryption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:36:57.441Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-157",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-157/"
}
],
"source": {
"lang": "en",
"value": "Ho Xuan Ninh (@Xuanninh1412) and Hoang Hai Long (@seadragnol) from Qrious Secure (@qriousec)"
},
"title": "Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3559",
"datePublished": "2026-03-13T20:36:57.441Z",
"dateReserved": "2026-03-04T19:42:45.880Z",
"dateUpdated": "2026-03-16T20:19:49.916Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3558 (GCVE-0-2026-3558)
Vulnerability from cvelistv5 – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:18- CWE-306 - Missing Authentication for Critical Function
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3558",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:18:31.279335Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:18:40.959Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:42.421Z",
"datePublic": "2026-03-06T21:19:21.476Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit Accessory Protocol Transient Pairing Mode Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28374."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:36:52.519Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-156",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-156/"
}
],
"source": {
"lang": "en",
"value": "Ho Xuan Ninh (@Xuanninh1412) and Hoang Hai Long (@seadragnol) from Qrious Secure (@qriousec)"
},
"title": "Philips Hue Bridge HomeKit Accessory Protocol Transient Pairing Mode Authentication Bypass Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3558",
"datePublished": "2026-03-13T20:36:52.519Z",
"dateReserved": "2026-03-04T19:42:42.383Z",
"dateUpdated": "2026-03-16T20:18:40.959Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3557 (GCVE-0-2026-3557)
Vulnerability from cvelistv5 – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:17- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3557",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:17:45.866601Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:17:59.717Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:37.503Z",
"datePublic": "2026-03-06T21:19:15.836Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge hap_pair_verify_handler Sub-TLV Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the hap_pair_verify_handler function of the hk_hap service, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-28337."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:36:48.632Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-155",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-155/"
}
],
"source": {
"lang": "en",
"value": "Viettel Cyber Security"
},
"title": "Philips Hue Bridge hap_pair_verify_handler Sub-TLV Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3557",
"datePublished": "2026-03-13T20:36:48.632Z",
"dateReserved": "2026-03-04T19:42:37.457Z",
"dateUpdated": "2026-03-16T20:17:59.717Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3556 (GCVE-0-2026-3556)
Vulnerability from cvelistv5 – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:17- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3556",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:16:52.038932Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:17:16.686Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:32.769Z",
"datePublic": "2026-03-06T21:19:09.676Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the hk_hap_pair_storage_put function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the HomeKit service. Was ZDI-CAN-28326."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:36:44.408Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-154",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-154/"
}
],
"source": {
"lang": "en",
"value": "InnoEdge Labs"
},
"title": "Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3556",
"datePublished": "2026-03-13T20:36:44.408Z",
"dateReserved": "2026-03-04T19:42:32.733Z",
"dateUpdated": "2026-03-16T20:17:16.686Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3555 (GCVE-0-2026-3555)
Vulnerability from cvelistv5 – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:16- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3555",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:15:51.424960Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:16:14.612Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:29.193Z",
"datePublic": "2026-03-06T21:19:00.069Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. User interaction is required to exploit this vulnerability in that the user must initiate the device pairing process.\n\nThe specific flaw exists within the handling of custom Zigbee ZCL frames in the Model Info download functionality. The issue results from the lack of proper validation of the size of data prior to copying it to a fixed-size heap buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28276."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:36:40.448Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-153",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-153/"
}
],
"source": {
"lang": "en",
"value": "Mehdi Talbi, Matthieu Breuil, Th\u00e9o Gordyjan from @Synacktiv"
},
"title": "Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3555",
"datePublished": "2026-03-13T20:36:40.448Z",
"dateReserved": "2026-03-04T19:42:29.133Z",
"dateUpdated": "2026-03-16T20:16:14.612Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
VAR-202603-0913
Vulnerability from variot - Updated: 2026-03-09 23:53This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. User interaction is required to exploit this vulnerability in that the user must initiate the device pairing process.The specific flaw exists within the handling of custom Zigbee ZCL frames in the Model Info download functionality. The issue results from the lack of proper validation of the size of data prior to copying it to a fixed-size heap buffer. An attacker can leverage this vulnerability to execute code in the context of the device.
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202603-0913",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "hue bridge",
"scope": null,
"trust": 0.7,
"vendor": "philips",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-153"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Mehdi Talbi, Matthieu Breuil, Th\u00e9o Gordyjan from @Synacktiv",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-153"
}
],
"trust": 0.7
},
"cve": "CVE-2026-3555",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.1,
"id": "CVE-2026-3555",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "ZDI",
"id": "CVE-2026-3555",
"trust": 0.7,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-153"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. User interaction is required to exploit this vulnerability in that the user must initiate the device pairing process.The specific flaw exists within the handling of custom Zigbee ZCL frames in the Model Info download functionality. The issue results from the lack of proper validation of the size of data prior to copying it to a fixed-size heap buffer. An attacker can leverage this vulnerability to execute code in the context of the device.",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-153"
}
],
"trust": 0.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-28276",
"trust": 0.7
},
{
"db": "NVD",
"id": "CVE-2026-3555",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-26-153",
"trust": 0.7
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-153"
}
]
},
"id": "VAR-202603-0913",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.5
},
"last_update_date": "2026-03-09T23:53:52.758000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Fixed in Bridge v2 Software version 1975170000",
"trust": 0.7,
"url": "https://www.philips-hue.com/en-ca/support/release-notes/bridge"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-153"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 0.7,
"url": "https://www.philips-hue.com/en-ca/support/release-notes/bridge"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-153"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-26-153"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2026-03-06T00:00:00",
"db": "ZDI",
"id": "ZDI-26-153"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2026-03-06T00:00:00",
"db": "ZDI",
"id": "ZDI-26-153"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "(Pwn2Own) Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-153"
}
],
"trust": 0.7
}
}
VAR-202603-0907
Vulnerability from variot - Updated: 2026-03-09 23:51This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.The specific flaw exists within the hap_pair_verify_handler function of the hk_hap service, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of root.
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202603-0907",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "hue bridge",
"scope": null,
"trust": 0.7,
"vendor": "philips",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-155"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Viettel Cyber Security",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-155"
}
],
"trust": 0.7
},
"cve": "CVE-2026-3557",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.1,
"id": "CVE-2026-3557",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "NONE",
"vectorString": "AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "ZDI",
"id": "CVE-2026-3557",
"trust": 0.7,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-155"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.The specific flaw exists within the hap_pair_verify_handler function of the hk_hap service, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of root.",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-155"
}
],
"trust": 0.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-28337",
"trust": 0.7
},
{
"db": "NVD",
"id": "CVE-2026-3557",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-26-155",
"trust": 0.7
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-155"
}
]
},
"id": "VAR-202603-0907",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.5
},
"last_update_date": "2026-03-09T23:51:31.712000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Fixed in Bridge v2 Software version 1975170000",
"trust": 0.7,
"url": "https://www.philips-hue.com/en-ca/support/release-notes/bridge"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-155"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 0.7,
"url": "https://www.philips-hue.com/en-ca/support/release-notes/bridge"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-155"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-26-155"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2026-03-06T00:00:00",
"db": "ZDI",
"id": "ZDI-26-155"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2026-03-06T00:00:00",
"db": "ZDI",
"id": "ZDI-26-155"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "(Pwn2Own) Philips Hue Bridge hap_pair_verify_handler Sub-TLV Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-155"
}
],
"trust": 0.7
}
}
VAR-202603-0928
Vulnerability from variot - Updated: 2026-03-09 23:51This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.The specific flaw exists within the hk_hap_pair_storage_put function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the HomeKit service.
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202603-0928",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "hue bridge",
"scope": null,
"trust": 0.7,
"vendor": "philips",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-154"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "InnoEdge Labs",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-154"
}
],
"trust": 0.7
},
"cve": "CVE-2026-3556",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2026-3556",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "NONE",
"vectorString": "AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "ZDI",
"id": "CVE-2026-3556",
"trust": 0.7,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-154"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.The specific flaw exists within the hk_hap_pair_storage_put function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the HomeKit service.",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-154"
}
],
"trust": 0.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-28326",
"trust": 0.7
},
{
"db": "NVD",
"id": "CVE-2026-3556",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-26-154",
"trust": 0.7
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-154"
}
]
},
"id": "VAR-202603-0928",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.5
},
"last_update_date": "2026-03-09T23:51:31.700000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Fixed in Bridge v2 Software version 1975170000",
"trust": 0.7,
"url": "https://www.philips-hue.com/en-ca/support/release-notes/bridge"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-154"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 0.7,
"url": "https://www.philips-hue.com/en-ca/support/release-notes/bridge"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-154"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-26-154"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2026-03-06T00:00:00",
"db": "ZDI",
"id": "ZDI-26-154"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2026-03-06T00:00:00",
"db": "ZDI",
"id": "ZDI-26-154"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "(Pwn2Own) Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-154"
}
],
"trust": 0.7
}
}
VAR-202603-0956
Vulnerability from variot - Updated: 2026-03-09 23:49This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.The specific flaw exists within the ed25519_sign_open function. The issue results from improper verification of a cryptographic signature. An attacker can leverage this vulnerability to bypass authentication on the system.
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202603-0956",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "hue bridge",
"scope": null,
"trust": 0.7,
"vendor": "philips",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-160"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Viettel Cyber Security",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-160"
}
],
"trust": 0.7
},
"cve": "CVE-2026-3562",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "ZDI",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.8,
"id": "CVE-2026-3562",
"impactScore": 3.4,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "NONE",
"vectorString": "AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
],
"severity": [
{
"author": "ZDI",
"id": "CVE-2026-3562",
"trust": 0.7,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-160"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.The specific flaw exists within the ed25519_sign_open function. The issue results from improper verification of a cryptographic signature. An attacker can leverage this vulnerability to bypass authentication on the system.",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-160"
}
],
"trust": 0.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-28480",
"trust": 0.7
},
{
"db": "NVD",
"id": "CVE-2026-3562",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-26-160",
"trust": 0.7
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-160"
}
]
},
"id": "VAR-202603-0956",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.5
},
"last_update_date": "2026-03-09T23:49:39.350000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Fixed in Bridge v2 Software version 1975170000",
"trust": 0.7,
"url": "https://www.philips-hue.com/en-ca/support/release-notes/bridge"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-160"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 0.7,
"url": "https://www.philips-hue.com/en-ca/support/release-notes/bridge"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-160"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-26-160"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2026-03-06T00:00:00",
"db": "ZDI",
"id": "ZDI-26-160"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2026-03-06T00:00:00",
"db": "ZDI",
"id": "ZDI-26-160"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "(Pwn2Own) Philips Hue Bridge hk_hap Ed25519 Signature Verification Authentication Bypass Vulnerability",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-160"
}
],
"trust": 0.7
}
}
VAR-202603-0936
Vulnerability from variot - Updated: 2026-03-09 23:47This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.The specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device.
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202603-0936",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "hue bridge",
"scope": null,
"trust": 0.7,
"vendor": "philips",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-158"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Xilokar (@xilokar@mamot.fr)",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-158"
}
],
"trust": 0.7
},
"cve": "CVE-2026-3560",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2026-3560",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "NONE",
"vectorString": "AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "ZDI",
"id": "CVE-2026-3560",
"trust": 0.7,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-158"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.The specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device.",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-158"
}
],
"trust": 0.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-28469",
"trust": 0.7
},
{
"db": "NVD",
"id": "CVE-2026-3560",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-26-158",
"trust": 0.7
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-158"
}
]
},
"id": "VAR-202603-0936",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.5
},
"last_update_date": "2026-03-09T23:47:24.755000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Fixed in Bridge v2 Software version 1975170000",
"trust": 0.7,
"url": "https://www.philips-hue.com/en-ca/support/release-notes/bridge"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-158"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 0.7,
"url": "https://www.philips-hue.com/en-ca/support/release-notes/bridge"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-158"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-26-158"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2026-03-06T00:00:00",
"db": "ZDI",
"id": "ZDI-26-158"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2026-03-06T00:00:00",
"db": "ZDI",
"id": "ZDI-26-158"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "(Pwn2Own) Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-158"
}
],
"trust": 0.7
}
}
VAR-202603-0912
Vulnerability from variot - Updated: 2026-03-09 23:44This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.The specific flaw exists within the handling of PUT requests to the characteristics endpoint. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device.
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202603-0912",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "hue bridge",
"scope": null,
"trust": 0.7,
"vendor": "philips",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-159"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Thalium team from Thales Group (@thalium_team)",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-159"
}
],
"trust": 0.7
},
"cve": "CVE-2026-3561",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.1,
"id": "CVE-2026-3561",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "NONE",
"vectorString": "AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "ZDI",
"id": "CVE-2026-3561",
"trust": 0.7,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-159"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.The specific flaw exists within the handling of PUT requests to the characteristics endpoint. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device.",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-159"
}
],
"trust": 0.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-28479",
"trust": 0.7
},
{
"db": "NVD",
"id": "CVE-2026-3561",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-26-159",
"trust": 0.7
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-159"
}
]
},
"id": "VAR-202603-0912",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.5
},
"last_update_date": "2026-03-09T23:44:44.895000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Fixed in Bridge v2 Software version 1975170000",
"trust": 0.7,
"url": "https://www.philips-hue.com/en-ca/support/release-notes/bridge"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-159"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 0.7,
"url": "https://www.philips-hue.com/en-ca/support/release-notes/bridge"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-159"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-26-159"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2026-03-06T00:00:00",
"db": "ZDI",
"id": "ZDI-26-159"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2026-03-06T00:00:00",
"db": "ZDI",
"id": "ZDI-26-159"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "(Pwn2Own) Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability",
"sources": [
{
"db": "ZDI",
"id": "ZDI-26-159"
}
],
"trust": 0.7
}
}