CVE-2026-3559 (GCVE-0-2026-3559)
Vulnerability from cvelistv5 – Published: 2026-03-13 20:36 – Updated: 2026-03-16 20:19
VLAI?
Title
Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability
Summary
Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the configuration of the SRP authentication mechanism in the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the use of a static nonce value. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28451.
Severity ?
8.1 (High)
CWE
- CWE-323 - Reusing a Nonce, Key Pair in Encryption
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
Date Public ?
2026-03-06 21:19
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3559",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:19:38.659046Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:19:49.916Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:45.919Z",
"datePublic": "2026-03-06T21:19:27.080Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of the SRP authentication mechanism in the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the use of a static nonce value. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28451."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-323",
"description": "CWE-323: Reusing a Nonce, Key Pair in Encryption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:36:57.441Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-157",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-157/"
}
],
"source": {
"lang": "en",
"value": "Ho Xuan Ninh (@Xuanninh1412) and Hoang Hai Long (@seadragnol) from Qrious Secure (@qriousec)"
},
"title": "Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3559",
"datePublished": "2026-03-13T20:36:57.441Z",
"dateReserved": "2026-03-04T19:42:45.880Z",
"dateUpdated": "2026-03-16T20:19:49.916Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2026-3559\",\"sourceIdentifier\":\"zdi-disclosures@trendmicro.com\",\"published\":\"2026-03-16T14:19:51.820\",\"lastModified\":\"2026-03-16T14:53:07.390\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\\n\\nThe specific flaw exists within the configuration of the SRP authentication mechanism in the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the use of a static nonce value. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28451.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":5.2}]},\"weaknesses\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-323\"}]}],\"references\":[{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-26-157/\",\"source\":\"zdi-disclosures@trendmicro.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-3559\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-03-16T20:19:38.659046Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-03-16T20:19:45.406Z\"}}], \"cna\": {\"title\": \"Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability\", \"source\": {\"lang\": \"en\", \"value\": \"Ho Xuan Ninh (@Xuanninh1412) and Hoang Hai Long (@seadragnol) from Qrious Secure (@qriousec)\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8.1, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\"}}], \"affected\": [{\"vendor\": \"Philips\", \"product\": \"Hue Bridge\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.73.1973146020\"}], \"defaultStatus\": \"unknown\"}], \"datePublic\": \"2026-03-06T21:19:27.080Z\", \"references\": [{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-26-157/\", \"name\": \"ZDI-26-157\", \"tags\": [\"x_research-advisory\"]}], \"dateAssigned\": \"2026-03-04T19:42:45.919Z\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\\n\\nThe specific flaw exists within the configuration of the SRP authentication mechanism in the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the use of a static nonce value. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28451.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-323\", \"description\": \"CWE-323: Reusing a Nonce, Key Pair in Encryption\"}]}], \"providerMetadata\": {\"orgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"shortName\": \"zdi\", \"dateUpdated\": \"2026-03-13T20:36:57.441Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-3559\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-03-16T20:19:49.916Z\", \"dateReserved\": \"2026-03-04T19:42:45.880Z\", \"assignerOrgId\": \"99f1926a-a320-47d8-bbb5-42feb611262e\", \"datePublished\": \"2026-03-13T20:36:57.441Z\", \"assignerShortName\": \"zdi\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…