Search
Find a vulnerability
Search criteria
18 vulnerabilities found for HG9 by Tenda
CVE-2026-11553 (GCVE-0-2026-11553)
Vulnerability from nvd โ Published: 2026-06-08 17:15 โ Updated: 2026-10-02 03:49
VLAI
EPSS
VEX
Title
Tenda HG7/HG9/HG10 formPPPEdit stack-based overflow
Summary
A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-06-08 18:49 UTC
Assigner
References
7 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369163 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369163/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11553 | third-party-advisory |
| https://vuldb.com/submit/836778 | third-party-advisory |
| https://github.com/xiezhihua-1127/Tenda-Stack-Oveโฆ | related |
| https://github.com/xiezhihua-1127/Tenda-Stack-Oveโฆ | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11553",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T18:49:04.954919Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T18:49:14.135Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
],
"product": "HG7",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "zhihua xie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-02T03:49:03.652Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369163 | Tenda HG7/HG9/HG10 formPPPEdit stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369163"
},
{
"name": "VDB-369163 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369163/cti"
},
{
"name": "CVE-2026-11553 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11553"
},
{
"name": "Submit #836778 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/836778"
},
{
"tags": [
"related"
],
"url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow.git"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow/blob/main/report.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-08T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-02T05:53:43.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG7/HG9/HG10 formPPPEdit stack-based overflow",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11553",
"datePublished": "2026-06-08T17:15:11.855Z",
"dateReserved": "2026-06-08T05:43:31.214Z",
"dateUpdated": "2026-10-02T03:49:03.652Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11499 (GCVE-0-2026-11499)
Vulnerability from nvd โ Published: 2026-06-08 07:00 โ Updated: 2026-10-02 03:48
VLAI
EPSS
VEX
Title
Tenda HG7/HG9/HG10 formDOMAINBLK stack-based overflow
Summary
A vulnerability was determined in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.
Severity
9.8 (Critical)
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-06-08 12:55 UTC
Assigner
References
7 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369119 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369119/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11499 | third-party-advisory |
| https://vuldb.com/submit/834888 | third-party-advisory |
| https://vuldb.com/submit/888875 | third-party-advisory |
| https://github.com/ssaaaa1234/Tenda-HG10-formDOMAโฆ | related |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11499",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T12:55:19.613788Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T12:55:29.374Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
],
"product": "HG7",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "moist (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 10,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-02T03:48:57.001Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369119 | Tenda HG7/HG9/HG10 formDOMAINBLK stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369119"
},
{
"name": "VDB-369119 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369119/cti"
},
{
"name": "CVE-2026-11499 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11499"
},
{
"name": "Submit #834888 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/834888"
},
{
"name": "Submit #888875 | Tenda HG10 HG7_HG9_HG10re_300001138 Denial of Service (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/888875"
},
{
"tags": [
"related"
],
"url": "https://github.com/ssaaaa1234/Tenda-HG10-formDOMAINBLK-stack-overflow-2"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-02T05:53:40.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG7/HG9/HG10 formDOMAINBLK stack-based overflow",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11499",
"datePublished": "2026-06-08T07:00:23.672Z",
"dateReserved": "2026-06-07T13:23:38.138Z",
"dateUpdated": "2026-10-02T03:48:57.001Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11498 (GCVE-0-2026-11498)
Vulnerability from nvd โ Published: 2026-06-08 06:45 โ Updated: 2026-10-02 03:48
VLAI
EPSS
VEX
Title
Tenda HG7/HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow
Summary
A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-06-08 12:47 UTC
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369118 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369118/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11498 | third-party-advisory |
| https://vuldb.com/submit/834887 | third-party-advisory |
| https://github.com/ssaaaa1234/tenda-hg10-voip-othโฆ | related |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11498",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T12:47:31.920390Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T16:22:24.244Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
],
"modules": [
"Web Management Interface"
],
"product": "HG7",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
],
"modules": [
"Web Management Interface"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
],
"modules": [
"Web Management Interface"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "moist (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-02T03:48:52.157Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369118 | Tenda HG7/HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369118"
},
{
"name": "VDB-369118 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369118/cti"
},
{
"name": "CVE-2026-11498 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11498"
},
{
"name": "Submit #834887 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/834887"
},
{
"tags": [
"related"
],
"url": "https://github.com/ssaaaa1234/tenda-hg10-voip-other-set-stack-overflow"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-02T05:53:37.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG7/HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11498",
"datePublished": "2026-06-08T06:45:21.289Z",
"dateReserved": "2026-06-07T13:22:12.336Z",
"dateUpdated": "2026-10-02T03:48:52.157Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2910 (GCVE-0-2026-2910)
Vulnerability from nvd โ Published: 2026-02-22 02:32 โ Updated: 2026-02-23 19:17
VLAI
EPSS
VEX
Title
Tenda HG9 formPing6 stack-based overflow
Summary
A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-02-23 19:17 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347219 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347219 | signaturepermissions-required |
| https://vuldb.com/?submit.755212 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/12 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2910",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:17:14.139751Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:17:27.114Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T02:32:11.075Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347219 | Tenda HG9 formPing6 stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347219"
},
{
"name": "VDB-347219 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347219"
},
{
"name": "Submit #755212 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755212"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/12"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:20:04.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 formPing6 stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2910",
"datePublished": "2026-02-22T02:32:11.075Z",
"dateReserved": "2026-02-20T20:14:51.686Z",
"dateUpdated": "2026-02-23T19:17:27.114Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2909 (GCVE-0-2026-2909)
Vulnerability from nvd โ Published: 2026-02-22 02:02 โ Updated: 2026-02-23 19:18
VLAI
EPSS
VEX
Title
Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow
Summary
A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-02-23 19:18 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347218 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347218 | signaturepermissions-required |
| https://vuldb.com/?submit.755211 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/11 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2909",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:18:27.278329Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:18:40.226Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Diagnostic Ping Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T02:02:14.122Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347218 | Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347218"
},
{
"name": "VDB-347218 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347218"
},
{
"name": "Submit #755211 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755211"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/11"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:20:02.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2909",
"datePublished": "2026-02-22T02:02:14.122Z",
"dateReserved": "2026-02-20T20:14:48.904Z",
"dateUpdated": "2026-02-23T19:18:40.226Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2908 (GCVE-0-2026-2908)
Vulnerability from nvd โ Published: 2026-02-22 02:02 โ Updated: 2026-02-23 19:19
VLAI
EPSS
VEX
Title
Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow
Summary
A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-02-23 19:19 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347217 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347217 | signaturepermissions-required |
| https://vuldb.com/?submit.755202 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/10 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2908",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:19:17.915757Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:19:51.049Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Loopback Detection Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T02:02:10.921Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347217 | Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347217"
},
{
"name": "VDB-347217 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347217"
},
{
"name": "Submit #755202 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755202"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/10"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:20:00.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2908",
"datePublished": "2026-02-22T02:02:10.921Z",
"dateReserved": "2026-02-20T20:14:45.983Z",
"dateUpdated": "2026-02-23T19:19:51.049Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2907 (GCVE-0-2026-2907)
Vulnerability from nvd โ Published: 2026-02-22 01:32 โ Updated: 2026-02-23 19:23
VLAI
EPSS
VEX
Title
Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow
Summary
A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-02-23 19:22 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347216 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347216 | signaturepermissions-required |
| https://vuldb.com/?submit.755201 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/9 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2907",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:22:46.303895Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:23:03.755Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"GPON Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T01:32:12.542Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347216 | Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347216"
},
{
"name": "VDB-347216 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347216"
},
{
"name": "Submit #755201 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755201"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/9"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:19:59.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2907",
"datePublished": "2026-02-22T01:32:12.542Z",
"dateReserved": "2026-02-20T20:14:43.142Z",
"dateUpdated": "2026-02-23T19:23:03.755Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2906 (GCVE-0-2026-2906)
Vulnerability from nvd โ Published: 2026-02-22 01:32 โ Updated: 2026-02-24 15:38
VLAI
EPSS
VEX
Title
Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow
Summary
A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-02-24 15:38 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347215 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347215 | signaturepermissions-required |
| https://vuldb.com/?submit.755193 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/8 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2906",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-24T15:38:13.838475Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-24T15:38:54.600Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Samba Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T01:32:09.390Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347215 | Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347215"
},
{
"name": "VDB-347215 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347215"
},
{
"name": "Submit #755193 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755193"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/8"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:19:58.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2906",
"datePublished": "2026-02-22T01:32:09.390Z",
"dateReserved": "2026-02-20T20:14:40.341Z",
"dateUpdated": "2026-02-24T15:38:54.600Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2905 (GCVE-0-2026-2905)
Vulnerability from nvd โ Published: 2026-02-22 01:02 โ Updated: 2026-02-23 19:13
VLAI
EPSS
VEX
Title
Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow
Summary
A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-02-23 19:13 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347214 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347214 | signaturepermissions-required |
| https://vuldb.com/?submit.755167 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/7 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2905",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:13:05.204806Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:13:59.154Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Wireless Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T01:02:10.433Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347214 | Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347214"
},
{
"name": "VDB-347214 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347214"
},
{
"name": "Submit #755167 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755167"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/7"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:19:56.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2905",
"datePublished": "2026-02-22T01:02:10.433Z",
"dateReserved": "2026-02-20T20:14:32.380Z",
"dateUpdated": "2026-02-23T19:13:59.154Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11553 (GCVE-0-2026-11553)
Vulnerability from cvelistv5 โ Published: 2026-06-08 17:15 โ Updated: 2026-10-02 03:49
VLAI
EPSS
VEX
Title
Tenda HG7/HG9/HG10 formPPPEdit stack-based overflow
Summary
A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-06-08 18:49 UTC
Assigner
References
7 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369163 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369163/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11553 | third-party-advisory |
| https://vuldb.com/submit/836778 | third-party-advisory |
| https://github.com/xiezhihua-1127/Tenda-Stack-Oveโฆ | related |
| https://github.com/xiezhihua-1127/Tenda-Stack-Oveโฆ | exploit |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11553",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T18:49:04.954919Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T18:49:14.135Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
],
"product": "HG7",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "zhihua xie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-02T03:49:03.652Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369163 | Tenda HG7/HG9/HG10 formPPPEdit stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369163"
},
{
"name": "VDB-369163 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369163/cti"
},
{
"name": "CVE-2026-11553 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11553"
},
{
"name": "Submit #836778 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/836778"
},
{
"tags": [
"related"
],
"url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow.git"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow/blob/main/report.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-08T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-02T05:53:43.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG7/HG9/HG10 formPPPEdit stack-based overflow",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11553",
"datePublished": "2026-06-08T17:15:11.855Z",
"dateReserved": "2026-06-08T05:43:31.214Z",
"dateUpdated": "2026-10-02T03:49:03.652Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11499 (GCVE-0-2026-11499)
Vulnerability from cvelistv5 โ Published: 2026-06-08 07:00 โ Updated: 2026-10-02 03:48
VLAI
EPSS
VEX
Title
Tenda HG7/HG9/HG10 formDOMAINBLK stack-based overflow
Summary
A vulnerability was determined in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.
Severity
9.8 (Critical)
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-06-08 12:55 UTC
Assigner
References
7 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369119 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369119/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11499 | third-party-advisory |
| https://vuldb.com/submit/834888 | third-party-advisory |
| https://vuldb.com/submit/888875 | third-party-advisory |
| https://github.com/ssaaaa1234/Tenda-HG10-formDOMAโฆ | related |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11499",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T12:55:19.613788Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T12:55:29.374Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
],
"product": "HG7",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "moist (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was determined in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 10,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-02T03:48:57.001Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369119 | Tenda HG7/HG9/HG10 formDOMAINBLK stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369119"
},
{
"name": "VDB-369119 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369119/cti"
},
{
"name": "CVE-2026-11499 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11499"
},
{
"name": "Submit #834888 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/834888"
},
{
"name": "Submit #888875 | Tenda HG10 HG7_HG9_HG10re_300001138 Denial of Service (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/888875"
},
{
"tags": [
"related"
],
"url": "https://github.com/ssaaaa1234/Tenda-HG10-formDOMAINBLK-stack-overflow-2"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-02T05:53:40.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG7/HG9/HG10 formDOMAINBLK stack-based overflow",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11499",
"datePublished": "2026-06-08T07:00:23.672Z",
"dateReserved": "2026-06-07T13:23:38.138Z",
"dateUpdated": "2026-10-02T03:48:57.001Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-11498 (GCVE-0-2026-11498)
Vulnerability from cvelistv5 โ Published: 2026-06-08 06:45 โ Updated: 2026-10-02 03:48
VLAI
EPSS
VEX
Title
Tenda HG7/HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow
Summary
A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-06-08 12:47 UTC
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://vuldb.com/vuln/369118 | vdb-entrytechnical-description |
| https://vuldb.com/vuln/369118/cti | signaturepermissions-required |
| https://vuldb.com/cve/CVE-2026-11498 | third-party-advisory |
| https://vuldb.com/submit/834887 | third-party-advisory |
| https://github.com/ssaaaa1234/tenda-hg10-voip-othโฆ | related |
| https://www.tenda.com.cn/ | product |
Impacted products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-11498",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-08T12:47:31.920390Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-08T16:22:24.244Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:hg7:*:*:*:*:*:*:*:*"
],
"modules": [
"Web Management Interface"
],
"product": "HG7",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg9:*:*:*:*:*:*:*:*"
],
"modules": [
"Web Management Interface"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
},
{
"cpes": [
"cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
],
"modules": [
"Web Management Interface"
],
"product": "HG10",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138_en_xpon"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "moist (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda HG7, HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-02T03:48:52.157Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-369118 | Tenda HG7/HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/vuln/369118"
},
{
"name": "VDB-369118 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/vuln/369118/cti"
},
{
"name": "CVE-2026-11498 | CVE Analysis and Report",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/cve/CVE-2026-11498"
},
{
"name": "Submit #834887 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/submit/834887"
},
{
"tags": [
"related"
],
"url": "https://github.com/ssaaaa1234/tenda-hg10-voip-other-set-stack-overflow"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-06-07T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-06-07T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-10-02T05:53:37.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG7/HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
"x_generator": [
"VulDB PVTS v202610"
]
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-11498",
"datePublished": "2026-06-08T06:45:21.289Z",
"dateReserved": "2026-06-07T13:22:12.336Z",
"dateUpdated": "2026-10-02T03:48:52.157Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2910 (GCVE-0-2026-2910)
Vulnerability from cvelistv5 โ Published: 2026-02-22 02:32 โ Updated: 2026-02-23 19:17
VLAI
EPSS
VEX
Title
Tenda HG9 formPing6 stack-based overflow
Summary
A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-02-23 19:17 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347219 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347219 | signaturepermissions-required |
| https://vuldb.com/?submit.755212 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/12 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2910",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:17:14.139751Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:17:27.114Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Tenda HG9 300001138. This vulnerability affects unknown code of the file /boaform/formPing6. Executing a manipulation of the argument pingAddr can lead to stack-based buffer overflow. The attack may be performed from remote. The exploit has been published and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T02:32:11.075Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347219 | Tenda HG9 formPing6 stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347219"
},
{
"name": "VDB-347219 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347219"
},
{
"name": "Submit #755212 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755212"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/12"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:20:04.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 formPing6 stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2910",
"datePublished": "2026-02-22T02:32:11.075Z",
"dateReserved": "2026-02-20T20:14:51.686Z",
"dateUpdated": "2026-02-23T19:17:27.114Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2909 (GCVE-0-2026-2909)
Vulnerability from cvelistv5 โ Published: 2026-02-22 02:02 โ Updated: 2026-02-23 19:18
VLAI
EPSS
VEX
Title
Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow
Summary
A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-02-23 19:18 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347218 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347218 | signaturepermissions-required |
| https://vuldb.com/?submit.755211 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/11 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2909",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:18:27.278329Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:18:40.226Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Diagnostic Ping Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was detected in Tenda HG9 300001138. This affects an unknown part of the file /boaform/formPing of the component Diagnostic Ping Endpoint. Performing a manipulation of the argument pingAddr results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit is now public and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T02:02:14.122Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347218 | Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347218"
},
{
"name": "VDB-347218 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347218"
},
{
"name": "Submit #755211 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755211"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/11"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:20:02.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Diagnostic Ping Endpoint formPing stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2909",
"datePublished": "2026-02-22T02:02:14.122Z",
"dateReserved": "2026-02-20T20:14:48.904Z",
"dateUpdated": "2026-02-23T19:18:40.226Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2908 (GCVE-0-2026-2908)
Vulnerability from cvelistv5 โ Published: 2026-02-22 02:02 โ Updated: 2026-02-23 19:19
VLAI
EPSS
VEX
Title
Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow
Summary
A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used.
Severity
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-02-23 19:19 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347217 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347217 | signaturepermissions-required |
| https://vuldb.com/?submit.755202 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/10 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2908",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:19:17.915757Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:19:51.049Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Loopback Detection Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security vulnerability has been detected in Tenda HG9 300001138. Affected by this issue is some unknown functionality of the file /boaform/formLoopBack of the component Loopback Detection Configuration Endpoint. Such manipulation of the argument Ethtype leads to stack-based buffer overflow. The attack can be executed remotely. The exploit has been disclosed publicly and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T02:02:10.921Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347217 | Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347217"
},
{
"name": "VDB-347217 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347217"
},
{
"name": "Submit #755202 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755202"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/10"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:20:00.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Loopback Detection Configuration Endpoint formLoopBack stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2908",
"datePublished": "2026-02-22T02:02:10.921Z",
"dateReserved": "2026-02-20T20:14:45.983Z",
"dateUpdated": "2026-02-23T19:19:51.049Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2907 (GCVE-0-2026-2907)
Vulnerability from cvelistv5 โ Published: 2026-02-22 01:32 โ Updated: 2026-02-23 19:23
VLAI
EPSS
VEX
Title
Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow
Summary
A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-02-23 19:22 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347216 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347216 | signaturepermissions-required |
| https://vuldb.com/?submit.755201 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/9 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2907",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:22:46.303895Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:23:03.755Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"GPON Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A weakness has been identified in Tenda HG9 300001138. Affected by this vulnerability is an unknown functionality of the file /boaform/formgponConf of the component GPON Configuration Endpoint. This manipulation of the argument fmgpon_loid/fmgpon_loid_password causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T01:32:12.542Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347216 | Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347216"
},
{
"name": "VDB-347216 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347216"
},
{
"name": "Submit #755201 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755201"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/9"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:19:59.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 GPON Configuration Endpoint formgponConf stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2907",
"datePublished": "2026-02-22T01:32:12.542Z",
"dateReserved": "2026-02-20T20:14:43.142Z",
"dateUpdated": "2026-02-23T19:23:03.755Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2906 (GCVE-0-2026-2906)
Vulnerability from cvelistv5 โ Published: 2026-02-22 01:32 โ Updated: 2026-02-24 15:38
VLAI
EPSS
VEX
Title
Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow
Summary
A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-02-24 15:38 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347215 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347215 | signaturepermissions-required |
| https://vuldb.com/?submit.755193 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/8 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2906",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-24T15:38:13.838475Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-24T15:38:54.600Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Samba Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A security flaw has been discovered in Tenda HG9 300001138. Affected is an unknown function of the file /boaform/formSamba of the component Samba Configuration Endpoint. The manipulation of the argument sambaCap results in stack-based buffer overflow. The attack may be launched remotely. The exploit has been released to the public and may be used for attacks."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T01:32:09.390Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347215 | Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347215"
},
{
"name": "VDB-347215 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347215"
},
{
"name": "Submit #755193 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755193"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/8"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:19:58.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Samba Configuration Endpoint formSamba stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2906",
"datePublished": "2026-02-22T01:32:09.390Z",
"dateReserved": "2026-02-20T20:14:40.341Z",
"dateUpdated": "2026-02-24T15:38:54.600Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-2905 (GCVE-0-2026-2905)
Vulnerability from cvelistv5 โ Published: 2026-02-22 01:02 โ Updated: 2026-02-23 19:13
VLAI
EPSS
VEX
Title
Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow
Summary
A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used.
Severity
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator ยท CISA-ADP (v2.0.3)
Decision recorded 2026-02-23 19:13 UTC
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.347214 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.347214 | signaturepermissions-required |
| https://vuldb.com/?submit.755167 | third-party-advisory |
| https://github.com/QIU-DIE/cve-nneeww/issues/7 | exploitissue-tracking |
| https://www.tenda.com.cn/ | product |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-2905",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-23T19:13:05.204806Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T19:13:59.154Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Wireless Configuration Endpoint"
],
"product": "HG9",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "300001138"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "LINXI666 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Tenda HG9 300001138. This impacts an unknown function of the file /boaform/formWlanSetup of the component Wireless Configuration Endpoint. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit is publicly available and might be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-22T01:02:10.433Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-347214 | Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.347214"
},
{
"name": "VDB-347214 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.347214"
},
{
"name": "Submit #755167 | Tenda HG9 V300001138 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.755167"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/QIU-DIE/cve-nneeww/issues/7"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-02-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-02-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-02-20T21:19:56.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda HG9 Wireless Configuration Endpoint formWlanSetup stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-2905",
"datePublished": "2026-02-22T01:02:10.433Z",
"dateReserved": "2026-02-20T20:14:32.380Z",
"dateUpdated": "2026-02-23T19:13:59.154Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}