Search criteria

6 vulnerabilities found for HG7HG9 by Tenda

CVE-2026-11553 (GCVE-0-2026-11553)

Vulnerability from nvd – Published: 2026-06-08 17:15 – Updated: 2026-06-08 18:49
VLAI
Title
Tenda HG7HG9/HG10 formPPPEdit stack-based overflow
Summary
A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Vendor Product Version
Tenda HG7HG9 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
Create a notification for this product.
Tenda HG10 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
zhihua xie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11553",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T18:49:04.954919Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T18:49:14.135Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
          ],
          "product": "HG7HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
          ],
          "product": "HG10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "zhihua xie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T17:15:11.855Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369163 | Tenda HG7HG9/HG10 formPPPEdit stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369163"
        },
        {
          "name": "VDB-369163 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369163/cti"
        },
        {
          "name": "CVE-2026-11553 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11553"
        },
        {
          "name": "Submit #836778 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/836778"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow.git"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow/blob/main/report.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-08T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-08T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-08T07:48:34.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG7HG9/HG10 formPPPEdit stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11553",
    "datePublished": "2026-06-08T17:15:11.855Z",
    "dateReserved": "2026-06-08T05:43:31.214Z",
    "dateUpdated": "2026-06-08T18:49:14.135Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11499 (GCVE-0-2026-11499)

Vulnerability from nvd – Published: 2026-06-08 07:00 – Updated: 2026-06-08 12:55
VLAI
Title
Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow
Summary
A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/vuln/369119 vdb-entrytechnical-description
https://vuldb.com/vuln/369119/cti signaturepermissions-required
https://vuldb.com/cve/CVE-2026-11499 third-party-advisory
https://vuldb.com/submit/834888 third-party-advisory
https://github.com/ssaaaa1234/Tenda-HG10-formDOMA… broken-link
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda HG7HG9 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
Create a notification for this product.
Tenda HG10 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
moist (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11499",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T12:55:19.613788Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T12:55:29.374Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
          ],
          "product": "HG7HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
          ],
          "product": "HG10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "moist (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 10,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T07:00:23.672Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369119 | Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369119"
        },
        {
          "name": "VDB-369119 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369119/cti"
        },
        {
          "name": "CVE-2026-11499 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11499"
        },
        {
          "name": "Submit #834888 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/834888"
        },
        {
          "tags": [
            "broken-link"
          ],
          "url": "https://github.com/ssaaaa1234/Tenda-HG10-formDOMAINBLK-stack-overflow-2"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-07T15:28:41.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11499",
    "datePublished": "2026-06-08T07:00:23.672Z",
    "dateReserved": "2026-06-07T13:23:38.138Z",
    "dateUpdated": "2026-06-08T12:55:29.374Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11498 (GCVE-0-2026-11498)

Vulnerability from nvd – Published: 2026-06-08 06:45 – Updated: 2026-06-08 16:22
VLAI
Title
Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow
Summary
A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/vuln/369118 vdb-entrytechnical-description
https://vuldb.com/vuln/369118/cti signaturepermissions-required
https://vuldb.com/cve/CVE-2026-11498 third-party-advisory
https://vuldb.com/submit/834887 third-party-advisory
https://github.com/ssaaaa1234/tenda-hg10-voip-oth… broken-link
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda HG7HG9 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
Create a notification for this product.
Tenda HG10 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
moist (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11498",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T12:47:31.920390Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T16:22:24.244Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Management Interface"
          ],
          "product": "HG7HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Management Interface"
          ],
          "product": "HG10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "moist (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T06:45:21.289Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369118 | Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369118"
        },
        {
          "name": "VDB-369118 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369118/cti"
        },
        {
          "name": "CVE-2026-11498 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11498"
        },
        {
          "name": "Submit #834887 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/834887"
        },
        {
          "tags": [
            "broken-link"
          ],
          "url": "https://github.com/ssaaaa1234/tenda-hg10-voip-other-set-stack-overflow"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-07T15:27:15.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11498",
    "datePublished": "2026-06-08T06:45:21.289Z",
    "dateReserved": "2026-06-07T13:22:12.336Z",
    "dateUpdated": "2026-06-08T16:22:24.244Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11553 (GCVE-0-2026-11553)

Vulnerability from cvelistv5 – Published: 2026-06-08 17:15 – Updated: 2026-06-08 18:49
VLAI
Title
Tenda HG7HG9/HG10 formPPPEdit stack-based overflow
Summary
A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
Impacted products
Vendor Product Version
Tenda HG7HG9 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
Create a notification for this product.
Tenda HG10 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
zhihua xie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11553",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T18:49:04.954919Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T18:49:14.135Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
          ],
          "product": "HG7HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
          ],
          "product": "HG10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "zhihua xie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T17:15:11.855Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369163 | Tenda HG7HG9/HG10 formPPPEdit stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369163"
        },
        {
          "name": "VDB-369163 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369163/cti"
        },
        {
          "name": "CVE-2026-11553 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11553"
        },
        {
          "name": "Submit #836778 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/836778"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow.git"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow/blob/main/report.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-08T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-08T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-08T07:48:34.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG7HG9/HG10 formPPPEdit stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11553",
    "datePublished": "2026-06-08T17:15:11.855Z",
    "dateReserved": "2026-06-08T05:43:31.214Z",
    "dateUpdated": "2026-06-08T18:49:14.135Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11499 (GCVE-0-2026-11499)

Vulnerability from cvelistv5 – Published: 2026-06-08 07:00 – Updated: 2026-06-08 12:55
VLAI
Title
Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow
Summary
A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/vuln/369119 vdb-entrytechnical-description
https://vuldb.com/vuln/369119/cti signaturepermissions-required
https://vuldb.com/cve/CVE-2026-11499 third-party-advisory
https://vuldb.com/submit/834888 third-party-advisory
https://github.com/ssaaaa1234/Tenda-HG10-formDOMA… broken-link
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda HG7HG9 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
Create a notification for this product.
Tenda HG10 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
moist (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11499",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T12:55:19.613788Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T12:55:29.374Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
          ],
          "product": "HG7HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
          ],
          "product": "HG10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "moist (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 10,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T07:00:23.672Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369119 | Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369119"
        },
        {
          "name": "VDB-369119 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369119/cti"
        },
        {
          "name": "CVE-2026-11499 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11499"
        },
        {
          "name": "Submit #834888 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/834888"
        },
        {
          "tags": [
            "broken-link"
          ],
          "url": "https://github.com/ssaaaa1234/Tenda-HG10-formDOMAINBLK-stack-overflow-2"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-07T15:28:41.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11499",
    "datePublished": "2026-06-08T07:00:23.672Z",
    "dateReserved": "2026-06-07T13:23:38.138Z",
    "dateUpdated": "2026-06-08T12:55:29.374Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-11498 (GCVE-0-2026-11498)

Vulnerability from cvelistv5 – Published: 2026-06-08 06:45 – Updated: 2026-06-08 16:22
VLAI
Title
Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow
Summary
A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/vuln/369118 vdb-entrytechnical-description
https://vuldb.com/vuln/369118/cti signaturepermissions-required
https://vuldb.com/cve/CVE-2026-11498 third-party-advisory
https://vuldb.com/submit/834887 third-party-advisory
https://github.com/ssaaaa1234/tenda-hg10-voip-oth… broken-link
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda HG7HG9 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
Create a notification for this product.
Tenda HG10 Affected: 300001138_en_xpon
    cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
moist (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-11498",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-08T12:47:31.920390Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-08T16:22:24.244Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Management Interface"
          ],
          "product": "HG7HG9",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
          ],
          "modules": [
            "Web Management Interface"
          ],
          "product": "HG10",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "300001138_en_xpon"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "moist (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-08T06:45:21.289Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-369118 | Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/vuln/369118"
        },
        {
          "name": "VDB-369118 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/vuln/369118/cti"
        },
        {
          "name": "CVE-2026-11498 | CVE Analysis and Report",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/cve/CVE-2026-11498"
        },
        {
          "name": "Submit #834887 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/submit/834887"
        },
        {
          "tags": [
            "broken-link"
          ],
          "url": "https://github.com/ssaaaa1234/tenda-hg10-voip-other-set-stack-overflow"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-06-07T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2026-06-07T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2026-06-07T15:27:15.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2026-11498",
    "datePublished": "2026-06-08T06:45:21.289Z",
    "dateReserved": "2026-06-07T13:22:12.336Z",
    "dateUpdated": "2026-06-08T16:22:24.244Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}