CVE-2026-8047 (GCVE-0-2026-8047)
Vulnerability from nvd – Published: 2026-05-26 06:49 – Updated: 2026-05-26 10:48
VLAI
Title
Out-of-bounds Write in CODESYS Control
Summary
The affected products perform improper length checking when parsing incoming HTTP requests, resulting in a size-limited out-of-bounds write. An unauthenticated remote attacker can exploit this flaw to cause a denial of service via a system crash on the affected device.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-1284 - Improper Validation of Specified Quantity in Input
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-8047",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T10:45:06.909963Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T10:48:24.087Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_rte_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_rte_for_beckhoff_cx_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_win_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_hmi_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_runtime_toolkit:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_empc_a_imx6_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_linux_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_virtual_control_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The affected products perform improper length checking when parsing incoming HTTP requests, resulting in a size-limited out-of-bounds write. An unauthenticated remote attacker can exploit this flaw to cause a denial of service via a system crash on the affected device."
}
],
"value": "The affected products perform improper length checking when parsing incoming HTTP requests, resulting in a size-limited out-of-bounds write. An unauthenticated remote attacker can exploit this flaw to cause a denial of service via a system crash on the affected device."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1284",
"description": "CWE-1284 Improper Validation of Specified Quantity in Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T06:49:54.813Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.certvde.com/en/advisories/VDE-2026-057/"
}
],
"source": {
"advisory": "VDE-2026-057",
"defect": [
"CERT@VDE#642073"
],
"discovery": "UNKNOWN"
},
"title": "Out-of-bounds Write in CODESYS Control",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2026-8047",
"datePublished": "2026-05-26T06:49:54.813Z",
"dateReserved": "2026-05-06T17:12:05.142Z",
"dateUpdated": "2026-05-26T10:48:24.087Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-8046 (GCVE-0-2026-8046)
Vulnerability from nvd – Published: 2026-05-26 06:45 – Updated: 2026-05-26 10:48
VLAI
Title
Incorrect Authorization in CODESYS Control
Summary
The affected products insufficiently verify authorization when deleting user accounts. An authenticated, low-privileged remote user can exploit this vulnerability to delete other users, including those with higher privileges.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-8046",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T10:44:58.318097Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T10:48:37.908Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_rte_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_rte_for_beckhoff_cx_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_win_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_hmi_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_runtime_toolkit:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_empc_a_imx6_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_linux_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_virtual_control_sl_:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "ABB AG"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The affected products insufficiently verify authorization when deleting user accounts. An authenticated, low-privileged remote user can exploit this vulnerability to delete other users, including those with higher privileges."
}
],
"value": "The affected products insufficiently verify authorization when deleting user accounts. An authenticated, low-privileged remote user can exploit this vulnerability to delete other users, including those with higher privileges."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863 Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T06:46:47.189Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.certvde.com/en/advisories/VDE-2026-056/"
}
],
"source": {
"advisory": "VDE-2026-056",
"defect": [
"CERT@VDE#642072"
],
"discovery": "UNKNOWN"
},
"title": "Incorrect Authorization in CODESYS Control",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2026-8046",
"datePublished": "2026-05-26T06:45:21.724Z",
"dateReserved": "2026-05-06T17:10:12.759Z",
"dateUpdated": "2026-05-26T10:48:37.908Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41660 (GCVE-0-2025-41660)
Vulnerability from nvd – Published: 2026-03-24 07:41 – Updated: 2026-03-24 13:16
VLAI
Title
CODESYS Control Boot Application Replacement Enables Code Execution
Summary
A low-privileged remote attacker may be able to replace the boot application of the CODESYS Control runtime system, enabling unauthorized code execution.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-669 - Incorrect Resource Transfer Between Spheres
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41660",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-24T13:15:49.570572Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-24T13:16:02.920Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Luca Borzacchiello from Nozomi Networks"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A low-privileged remote attacker may be able to replace the boot application of the CODESYS Control runtime system, enabling unauthorized code execution.\u003cbr\u003e"
}
],
"value": "A low-privileged remote attacker may be able to replace the boot application of the CODESYS Control runtime system, enabling unauthorized code execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-669",
"description": "CWE-669 Incorrect Resource Transfer Between Spheres",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-24T07:41:43.004Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2026-011"
}
],
"source": {
"advisory": "VDE-2026-011",
"defect": [
"CERT@VDE#641802"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control Boot Application Replacement Enables Code Execution",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41660",
"datePublished": "2026-03-24T07:41:43.004Z",
"dateReserved": "2025-04-16T11:17:48.307Z",
"dateUpdated": "2026-03-24T13:16:02.920Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41738 (GCVE-0-2025-41738)
Vulnerability from nvd – Published: 2025-12-01 10:02 – Updated: 2025-12-01 14:00
VLAI
Title
CODESYS Control - Invalid type usage in visualization
Summary
An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Assigner
References
1 reference
Impacted products
17 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Remote Target Visu |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41738",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-01T13:59:44.375519Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-01T14:00:28.509Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Remote Target Visu",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-843",
"description": "CWE-843 Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-01T10:02:33.407Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-100"
}
],
"source": {
"advisory": "VDE-2025-100",
"defect": [
"CERT@VDE#641889"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control - Invalid type usage in visualization",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41738",
"datePublished": "2025-12-01T10:02:33.407Z",
"dateReserved": "2025-04-16T11:17:48.320Z",
"dateUpdated": "2025-12-01T14:00:28.509Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-8175 (GCVE-0-2024-8175)
Vulnerability from nvd – Published: 2024-09-25 08:04 – Updated: 2024-09-25 14:02
VLAI
Title
CODESYS: web server vulnerable to DoS
Summary
An unauthenticated remote attacker can causes the CODESYS web server to access invalid memory which results in a DoS.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://cert.vde.com/en/advisories/VDE-2024-057 | |
| https://customers.codesys.com/index.php?eID=dumpF… | vendor-advisory |
Impacted products
22 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Embedded Target Visu Toolkit |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Remote Target Visu Toolkit |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| codesys | runtime_toolkit |
Affected:
0 , < 4.14.0.0
(custom)
cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_empc-a\/imx6_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_rte_\(for_beckhoff_cx\)_sl |
Affected:
0 , < 3.5.20.30
(custom)
cpe:2.3:a:codesys:control_rte_\(for_beckhoff_cx\)_sl:*:*:*:*:*:*:*:* |
|
| codesys | virtual_control_sl |
Affected:
0 , < 4.14.0.0
(custom)
cpe:2.3:a:codesys:virtual_control_sl:*:*:*:*:*:*:*:* |
|
| codesys | runtime_toolkit |
Affected:
0 , < 3.5.20.30
(custom)
cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(for_beckhoff_cx\\)_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(for_beckhoff_cx\\)_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:virtual_control_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "virtual_control_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8175",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-25T13:44:03.391474Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-25T14:02:28.368Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Embedded Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Remote Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ABB"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can\u0026nbsp;causes the CODESYS web server to access invalid memory which results in a DoS."
}
],
"value": "An unauthenticated remote attacker can\u00a0causes the CODESYS web server to access invalid memory which results in a DoS."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-25T13:33:10.408Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-057"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download="
}
],
"source": {
"advisory": "VDE-2024-057",
"defect": [
"CERT@VDE#641681"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS: web server vulnerable to DoS",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-8175",
"datePublished": "2024-09-25T08:04:23.196Z",
"dateReserved": "2024-08-26T09:58:34.794Z",
"dateUpdated": "2024-09-25T14:02:28.368Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5000 (GCVE-0-2024-5000)
Vulnerability from nvd – Published: 2024-06-04 08:54 – Updated: 2024-08-01 20:55
VLAI
Title
CODESYS: Incorrect calculation of buffer size can cause DoS on CODESYS OPC UA products
Summary
An unauthenticated remote attacker can use a malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-131 - Incorrect Calculation of Buffer Size
Assigner
References
Impacted products
29 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| codesys | control_for_empc-a\/imx6_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_empc-a\/imx6_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_beaglebone_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_iot2000_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_linux_arm_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_linux_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_pfc200_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_plcnext_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_raspberry_pi_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_wago_touch_panels_600_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_rte_\(for_beckhoff_cx\)_sl |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:control_rte_\(for_beckhoff_cx\)_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_rte_\(sl\) |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:control_rte_\(sl\):*:*:*:*:*:*:*:* |
|
| codesys | control_win_\(sl\) |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:control_win_\(sl\):*:*:*:*:*:*:*:* |
|
| codesys | runtime_toolkit |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:* |
|
| codesys | hmi_\(sl\) |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:hmi_\(sl\):*:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_empc-a\\/imx6_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_beaglebone_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_iot2000_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_linux_arm_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_linux_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_pfc200_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_plcnext_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_raspberry_pi_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_wago_touch_panels_600_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(for_beckhoff_cx\\)_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(for_beckhoff_cx\\)_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_win_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_win_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:hmi_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hmi_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5000",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-06T14:26:44.507505Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T14:44:44.216Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.389Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2024-026"
},
{
"tags": [
"x_transferred"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18355\u0026token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1\u0026download="
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ABB Schweiz AG."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can use a\u0026nbsp;malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker can use a\u00a0malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-131",
"description": "CWE-131 Incorrect Calculation of Buffer Size",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T08:54:06.522Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-026"
},
{
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18355\u0026token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1\u0026download="
}
],
"source": {
"advisory": "VDE-2024-026",
"defect": [
"CERT@VDE#641630"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS: Incorrect calculation of buffer size can cause DoS on CODESYS OPC UA products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-5000",
"datePublished": "2024-06-04T08:54:06.522Z",
"dateReserved": "2024-05-16T12:09:56.937Z",
"dateUpdated": "2024-08-01T20:55:10.389Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5751 (GCVE-0-2023-5751)
Vulnerability from nvd – Published: 2024-06-04 08:54 – Updated: 2024-08-02 08:07
VLAI
Title
CODESYS: Development system prone to DoS through exposure of resource to wrong sphere
Summary
A local attacker with low privileges can read and modify any users files and cause a DoS in the working directory of the affected products due to exposure of resource to wrong sphere.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Edge Gateway for Windows |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Gateway for Windows |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| codesys | control_win_sl |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:control_win_sl:0:*:*:*:*:*:*:* |
|
| codesys | development_system_v3 |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:development_system_v3:0:*:*:*:*:*:*:* |
|
| codesys | edge_gateway |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:edge_gateway:0:*:*:*:*:*:*:* |
|
| codesys | gateway |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:gateway:0:*:*:*:*:*:*:* |
|
| codesys | hmi_sl |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:hmi_sl:0:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:codesys:control_win_sl:0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_win_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:development_system_v3:0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "development_system_v3",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:edge_gateway:0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "edge_gateway",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:gateway:0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "gateway",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:hmi_sl:0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hmi_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5751",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-04T14:51:51.731368Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:28:31.539Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:07:32.848Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2024-027"
},
{
"tags": [
"x_transferred"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18354\u0026token=f3e92a942c3a2f90c272a5ded7598c6a0b5f4924\u0026download="
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Edge Gateway for Windows",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Gateway for Windows",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "joker63"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A local attacker with low privileges can read and modify any users files and cause a DoS in the working directory of the affected products due to exposure of resource to wrong sphere.\u0026nbsp;\u003cbr\u003e"
}
],
"value": "A local attacker with low privileges can read and modify any users files and cause a DoS in the working directory of the affected products due to exposure of resource to wrong sphere.\u00a0\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668 Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T08:54:22.046Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-027"
},
{
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18354\u0026token=f3e92a942c3a2f90c272a5ded7598c6a0b5f4924\u0026download="
}
],
"source": {
"advisory": "VDE-2024-027",
"defect": [
"CERT@VDE#64603"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS: Development system prone to DoS through exposure of resource to wrong sphere",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-5751",
"datePublished": "2024-06-04T08:54:22.046Z",
"dateReserved": "2023-10-24T11:46:25.505Z",
"dateUpdated": "2024-08-02T08:07:32.848Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-4046 (GCVE-0-2022-4046)
Vulnerability from nvd – Published: 2023-08-03 12:39 – Updated: 2026-05-29 14:06
VLAI
Title
CODESYS: Improper memory restrictions fro CODESYS Control
Summary
In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
References
1 reference
Impacted products
14 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
all
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
all
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
all
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
all
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
all
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
all
|
Date Public
2023-08-03 10:30
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:27:54.486Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-025/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-4046",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:06:27.478239Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:06:35.326Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device."
}
],
"value": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T12:39:44.002Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-025/"
}
],
"source": {
"defect": [
"CERT@VDE#64299"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper memory restrictions fro CODESYS Control",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-4046",
"datePublished": "2023-08-03T12:39:44.002Z",
"dateReserved": "2022-11-17T07:07:09.714Z",
"dateUpdated": "2026-05-29T14:06:35.326Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-37559 (GCVE-0-2023-37559)
Vulnerability from nvd – Published: 2023-08-03 11:06 – Updated: 2024-10-11 18:09
VLAI
Title
CODESYS Improper Validation of Consistency within Input in multiple products
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.700Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37559",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:07:28.102576Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:09:05.823Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558"
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:56.079Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Validation of Consistency within Input in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37559",
"datePublished": "2023-08-03T11:06:56.079Z",
"dateReserved": "2023-07-07T07:39:19.122Z",
"dateUpdated": "2024-10-11T18:09:05.823Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37558 (GCVE-0-2023-37558)
Vulnerability from nvd – Published: 2023-08-03 11:06 – Updated: 2024-10-11 18:09
VLAI
Title
CODESYS Improper Validation of Consistency within Input in multiple products
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.767Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37558",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:07:13.616622Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:09:20.780Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559"
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:36.112Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Validation of Consistency within Input in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37558",
"datePublished": "2023-08-03T11:06:36.112Z",
"dateReserved": "2023-07-07T07:39:19.121Z",
"dateUpdated": "2024-10-11T18:09:20.780Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37557 (GCVE-0-2023-37557)
Vulnerability from nvd – Published: 2023-08-03 11:06 – Updated: 2024-10-09 20:52
VLAI
Title
CODESYS Heap-based Buffer Overflow in multiple products
Summary
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.379Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37557",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:48:56.664856Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:52:16.817Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition."
}
],
"value": "After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted remote communication requests can cause the CmpAppBP component to overwrite a heap-based buffer, which can lead to a denial-of-service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:06:17.884Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Heap-based Buffer Overflow in multiple products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37557",
"datePublished": "2023-08-03T11:06:17.884Z",
"dateReserved": "2023-07-07T07:39:19.121Z",
"dateUpdated": "2024-10-09T20:52:16.817Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37556 (GCVE-0-2023-37556)
Vulnerability from nvd – Published: 2023-08-03 11:05 – Updated: 2024-10-09 20:52
VLAI
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37555.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.852Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37556",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:49:03.697246Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:52:36.722Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37553,\u0026nbsp;CVE-2023-37554 and CVE-2023-37555.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553,\u00a0CVE-2023-37554 and CVE-2023-37555.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:05:52.986Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37556",
"datePublished": "2023-08-03T11:05:52.986Z",
"dateReserved": "2023-07-07T07:39:19.120Z",
"dateUpdated": "2024-10-09T20:52:36.722Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37555 (GCVE-0-2023-37555)
Vulnerability from nvd – Published: 2023-08-03 11:05 – Updated: 2024-10-09 20:52
VLAI
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37554 and CVE-2023-37556.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.445Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37555",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T20:49:10.954455Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T20:52:51.974Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37553,\u0026nbsp;CVE-2023-37554 and\u0026nbsp;CVE-2023-37556.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553,\u00a0CVE-2023-37554 and\u00a0CVE-2023-37556.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:05:33.660Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37555",
"datePublished": "2023-08-03T11:05:33.660Z",
"dateReserved": "2023-07-07T07:39:19.120Z",
"dateUpdated": "2024-10-09T20:52:51.974Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37554 (GCVE-0-2023-37554)
Vulnerability from nvd – Published: 2023-08-03 11:05 – Updated: 2024-10-11 18:09
VLAI
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37553, CVE-2023-37555 and CVE-2023-37556.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.422Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37554",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:05:06.756495Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:09:34.979Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37553, CVE-2023-37555 and\u0026nbsp;CVE-2023-37556.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37553, CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:05:09.750Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37554",
"datePublished": "2023-08-03T11:05:09.750Z",
"dateReserved": "2023-07-07T07:39:16.323Z",
"dateUpdated": "2024-10-11T18:09:34.979Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37553 (GCVE-0-2023-37553)
Vulnerability from nvd – Published: 2023-08-03 11:04 – Updated: 2024-10-11 18:10
VLAI
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37552, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.602Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37553",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:05:01.815292Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:10:16.403Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u0026nbsp;CVE-2023-37552,\u0026nbsp;CVE-2023-37554,\u0026nbsp;CVE-2023-37555 and\u0026nbsp;CVE-2023-37556.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to\u00a0CVE-2023-37552,\u00a0CVE-2023-37554,\u00a0CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:04:39.061Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37553",
"datePublished": "2023-08-03T11:04:39.061Z",
"dateReserved": "2023-07-07T07:39:16.323Z",
"dateUpdated": "2024-10-11T18:10:16.403Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37552 (GCVE-0-2023-37552)
Vulnerability from nvd – Published: 2023-08-03 11:04 – Updated: 2024-10-11 18:10
VLAI
Title
CODESYS Improper Input Validation in CmpAppBP
Summary
In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553, CVE-2023-37554, CVE-2023-37555 and CVE-2023-37556.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.508Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37552",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:04:09.376275Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:10:33.714Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553,\u0026nbsp;CVE-2023-37554,\u0026nbsp;CVE-2023-37555 and\u0026nbsp;CVE-2023-37556.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple versions of multiple Codesys products, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpAppBP component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37553,\u00a0CVE-2023-37554,\u00a0CVE-2023-37555 and\u00a0CVE-2023-37556.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:04:04.128Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Improper Input Validation in CmpAppBP",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37552",
"datePublished": "2023-08-03T11:04:04.128Z",
"dateReserved": "2023-07-07T07:39:16.323Z",
"dateUpdated": "2024-10-11T18:10:33.714Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37551 (GCVE-0-2023-37551)
Vulnerability from nvd – Published: 2023-08-03 11:03 – Updated: 2024-10-11 18:10
VLAI
Title
CODESYS Files or Directories Accessible to External Parties in CmpApp
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-552 - Files or Directories Accessible to External Parties
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.609Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37551",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:01:50.770279Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:10:51.431Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller."
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specially crafted network communication requests can utilize the CmpApp component to download files with any file extensions to the controller. In contrast to the regular file download via CmpFileTransfer, no filtering of certain file types is performed here. As a result, the integrity of the CODESYS control runtime system may be compromised by the files loaded onto the controller."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-552",
"description": "CWE-552 Files or Directories Accessible to External Parties",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:03:37.457Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019/"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS Files or Directories Accessible to External Parties in CmpApp",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37551",
"datePublished": "2023-08-03T11:03:37.457Z",
"dateReserved": "2023-07-07T07:39:16.323Z",
"dateUpdated": "2024-10-11T18:10:51.431Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37550 (GCVE-0-2023-37550)
Vulnerability from nvd – Published: 2023-08-03 11:03 – Updated: 2024-10-11 18:11
VLAI
Title
CODESYS: Improper Input Validation in CmpApp component
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.425Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37550",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:01:46.088420Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:11:18.756Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u0026nbsp;CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37548 and CVE-2023-37549.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:03:09.222Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper Input Validation in CmpApp component",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37550",
"datePublished": "2023-08-03T11:03:09.222Z",
"dateReserved": "2023-07-07T07:39:16.322Z",
"dateUpdated": "2024-10-11T18:11:18.756Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37549 (GCVE-0-2023-37549)
Vulnerability from nvd – Published: 2023-08-03 11:02 – Updated: 2024-10-11 18:12
VLAI
Title
CODESYS: Improper Input Validation in CmpApp component
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.241Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37549",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T18:01:40.613696Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:12:01.720Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u0026nbsp;CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37548 and CVE-2023-37550\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:02:33.725Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper Input Validation in CmpApp component",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37549",
"datePublished": "2023-08-03T11:02:33.725Z",
"dateReserved": "2023-07-07T07:39:16.322Z",
"dateUpdated": "2024-10-11T18:12:01.720Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37548 (GCVE-0-2023-37548)
Vulnerability from nvd – Published: 2023-08-03 11:02 – Updated: 2024-10-11 18:12
VLAI
Title
CODESYS: Improper Input Validation in CmpApp component
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.432Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37548",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:59:49.760916Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:12:26.294Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u0026nbsp;CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546,\u00a0CVE-2023-37547, CVE-2023-37549 and CVE-2023-37550\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:02:02.224Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper Input Validation in CmpApp component",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37548",
"datePublished": "2023-08-03T11:02:02.224Z",
"dateReserved": "2023-07-07T07:39:16.322Z",
"dateUpdated": "2024-10-11T18:12:26.294Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37547 (GCVE-0-2023-37547)
Vulnerability from nvd – Published: 2023-08-03 11:01 – Updated: 2024-10-11 18:12
VLAI
Title
CODESYS: Improper Input Validation in CmpApp component
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.418Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37547",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:59:39.095120Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:12:55.550Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37546, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:01:10.534Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper Input Validation in CmpApp component",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37547",
"datePublished": "2023-08-03T11:01:10.534Z",
"dateReserved": "2023-07-07T07:39:16.322Z",
"dateUpdated": "2024-10-11T18:12:55.550Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-37546 (GCVE-0-2023-37546)
Vulnerability from nvd – Published: 2023-08-03 11:00 – Updated: 2024-10-11 18:14
VLAI
Title
CODESYS: Improper Input Validation in CmpApp component
Summary
In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < V4.10.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < V3.5.19.20
(semver)
|
|
| CODESYS | CODESYS Safety SIL2 Runtime Toolkit |
Affected:
0 , < V3.5.19.20
(semver)
|
Date Public
2023-08-03 10:30
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:16:30.484Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37546",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T17:59:33.810402Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T18:14:28.818Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V4.10.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Safety SIL2 Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "V3.5.19.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Vladimir Tokarev, Section 52, Azure IoT Security at Microsoft"
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "In multiple Codesys products in multiple versions, after successful authentication as a user, specific crafted network communication requests with inconsistent content can cause the CmpApp component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37545, CVE-2023-37547, CVE-2023-37548, CVE-2023-37549 and CVE-2023-37550\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T11:00:33.624Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-019"
}
],
"source": {
"advisory": "VDE-2023-019",
"defect": [
"CERT@VDE#64558"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper Input Validation in CmpApp component",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-37546",
"datePublished": "2023-08-03T11:00:33.624Z",
"dateReserved": "2023-07-07T07:39:16.322Z",
"dateUpdated": "2024-10-11T18:14:28.818Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-8047 (GCVE-0-2026-8047)
Vulnerability from cvelistv5 – Published: 2026-05-26 06:49 – Updated: 2026-05-26 10:48
VLAI
Title
Out-of-bounds Write in CODESYS Control
Summary
The affected products perform improper length checking when parsing incoming HTTP requests, resulting in a size-limited out-of-bounds write. An unauthenticated remote attacker can exploit this flaw to cause a denial of service via a system crash on the affected device.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-1284 - Improper Validation of Specified Quantity in Input
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-8047",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T10:45:06.909963Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T10:48:24.087Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_rte_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_rte_for_beckhoff_cx_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_win_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_hmi_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_runtime_toolkit:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_empc_a_imx6_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_linux_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_virtual_control_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The affected products perform improper length checking when parsing incoming HTTP requests, resulting in a size-limited out-of-bounds write. An unauthenticated remote attacker can exploit this flaw to cause a denial of service via a system crash on the affected device."
}
],
"value": "The affected products perform improper length checking when parsing incoming HTTP requests, resulting in a size-limited out-of-bounds write. An unauthenticated remote attacker can exploit this flaw to cause a denial of service via a system crash on the affected device."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1284",
"description": "CWE-1284 Improper Validation of Specified Quantity in Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T06:49:54.813Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.certvde.com/en/advisories/VDE-2026-057/"
}
],
"source": {
"advisory": "VDE-2026-057",
"defect": [
"CERT@VDE#642073"
],
"discovery": "UNKNOWN"
},
"title": "Out-of-bounds Write in CODESYS Control",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2026-8047",
"datePublished": "2026-05-26T06:49:54.813Z",
"dateReserved": "2026-05-06T17:12:05.142Z",
"dateUpdated": "2026-05-26T10:48:24.087Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-8046 (GCVE-0-2026-8046)
Vulnerability from cvelistv5 – Published: 2026-05-26 06:45 – Updated: 2026-05-26 10:48
VLAI
Title
Incorrect Authorization in CODESYS Control
Summary
The affected products insufficiently verify authorization when deleting user accounts. An authenticated, low-privileged remote user can exploit this vulnerability to delete other users, including those with higher privileges.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-8046",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T10:44:58.318097Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T10:48:37.908Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_rte_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_rte_for_beckhoff_cx_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_win_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_hmi_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_runtime_toolkit:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_empc_a_imx6_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_linux_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_virtual_control_sl_:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "ABB AG"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The affected products insufficiently verify authorization when deleting user accounts. An authenticated, low-privileged remote user can exploit this vulnerability to delete other users, including those with higher privileges."
}
],
"value": "The affected products insufficiently verify authorization when deleting user accounts. An authenticated, low-privileged remote user can exploit this vulnerability to delete other users, including those with higher privileges."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863 Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T06:46:47.189Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.certvde.com/en/advisories/VDE-2026-056/"
}
],
"source": {
"advisory": "VDE-2026-056",
"defect": [
"CERT@VDE#642072"
],
"discovery": "UNKNOWN"
},
"title": "Incorrect Authorization in CODESYS Control",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2026-8046",
"datePublished": "2026-05-26T06:45:21.724Z",
"dateReserved": "2026-05-06T17:10:12.759Z",
"dateUpdated": "2026-05-26T10:48:37.908Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41660 (GCVE-0-2025-41660)
Vulnerability from cvelistv5 – Published: 2026-03-24 07:41 – Updated: 2026-03-24 13:16
VLAI
Title
CODESYS Control Boot Application Replacement Enables Code Execution
Summary
A low-privileged remote attacker may be able to replace the boot application of the CODESYS Control runtime system, enabling unauthorized code execution.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-669 - Incorrect Resource Transfer Between Spheres
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41660",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-24T13:15:49.570572Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-24T13:16:02.920Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Luca Borzacchiello from Nozomi Networks"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A low-privileged remote attacker may be able to replace the boot application of the CODESYS Control runtime system, enabling unauthorized code execution.\u003cbr\u003e"
}
],
"value": "A low-privileged remote attacker may be able to replace the boot application of the CODESYS Control runtime system, enabling unauthorized code execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-669",
"description": "CWE-669 Incorrect Resource Transfer Between Spheres",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-24T07:41:43.004Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2026-011"
}
],
"source": {
"advisory": "VDE-2026-011",
"defect": [
"CERT@VDE#641802"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control Boot Application Replacement Enables Code Execution",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41660",
"datePublished": "2026-03-24T07:41:43.004Z",
"dateReserved": "2025-04-16T11:17:48.307Z",
"dateUpdated": "2026-03-24T13:16:02.920Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41738 (GCVE-0-2025-41738)
Vulnerability from cvelistv5 – Published: 2025-12-01 10:02 – Updated: 2025-12-01 14:00
VLAI
Title
CODESYS Control - Invalid type usage in visualization
Summary
An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Assigner
References
1 reference
Impacted products
17 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Remote Target Visu |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41738",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-01T13:59:44.375519Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-01T14:00:28.509Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Remote Target Visu",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-843",
"description": "CWE-843 Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-01T10:02:33.407Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-100"
}
],
"source": {
"advisory": "VDE-2025-100",
"defect": [
"CERT@VDE#641889"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control - Invalid type usage in visualization",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41738",
"datePublished": "2025-12-01T10:02:33.407Z",
"dateReserved": "2025-04-16T11:17:48.320Z",
"dateUpdated": "2025-12-01T14:00:28.509Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-8175 (GCVE-0-2024-8175)
Vulnerability from cvelistv5 – Published: 2024-09-25 08:04 – Updated: 2024-09-25 14:02
VLAI
Title
CODESYS: web server vulnerable to DoS
Summary
An unauthenticated remote attacker can causes the CODESYS web server to access invalid memory which results in a DoS.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://cert.vde.com/en/advisories/VDE-2024-057 | |
| https://customers.codesys.com/index.php?eID=dumpF… | vendor-advisory |
Impacted products
22 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Embedded Target Visu Toolkit |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Remote Target Visu Toolkit |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| codesys | runtime_toolkit |
Affected:
0 , < 4.14.0.0
(custom)
cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_empc-a\/imx6_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_rte_\(for_beckhoff_cx\)_sl |
Affected:
0 , < 3.5.20.30
(custom)
cpe:2.3:a:codesys:control_rte_\(for_beckhoff_cx\)_sl:*:*:*:*:*:*:*:* |
|
| codesys | virtual_control_sl |
Affected:
0 , < 4.14.0.0
(custom)
cpe:2.3:a:codesys:virtual_control_sl:*:*:*:*:*:*:*:* |
|
| codesys | runtime_toolkit |
Affected:
0 , < 3.5.20.30
(custom)
cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(for_beckhoff_cx\\)_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(for_beckhoff_cx\\)_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:virtual_control_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "virtual_control_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8175",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-25T13:44:03.391474Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-25T14:02:28.368Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Embedded Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Remote Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ABB"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can\u0026nbsp;causes the CODESYS web server to access invalid memory which results in a DoS."
}
],
"value": "An unauthenticated remote attacker can\u00a0causes the CODESYS web server to access invalid memory which results in a DoS."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-25T13:33:10.408Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-057"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download="
}
],
"source": {
"advisory": "VDE-2024-057",
"defect": [
"CERT@VDE#641681"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS: web server vulnerable to DoS",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-8175",
"datePublished": "2024-09-25T08:04:23.196Z",
"dateReserved": "2024-08-26T09:58:34.794Z",
"dateUpdated": "2024-09-25T14:02:28.368Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-5751 (GCVE-0-2023-5751)
Vulnerability from cvelistv5 – Published: 2024-06-04 08:54 – Updated: 2024-08-02 08:07
VLAI
Title
CODESYS: Development system prone to DoS through exposure of resource to wrong sphere
Summary
A local attacker with low privileges can read and modify any users files and cause a DoS in the working directory of the affected products due to exposure of resource to wrong sphere.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
References
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Development System V3 |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Edge Gateway for Windows |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Gateway for Windows |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| codesys | control_win_sl |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:control_win_sl:0:*:*:*:*:*:*:* |
|
| codesys | development_system_v3 |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:development_system_v3:0:*:*:*:*:*:*:* |
|
| codesys | edge_gateway |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:edge_gateway:0:*:*:*:*:*:*:* |
|
| codesys | gateway |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:gateway:0:*:*:*:*:*:*:* |
|
| codesys | hmi_sl |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:hmi_sl:0:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:codesys:control_win_sl:0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_win_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:development_system_v3:0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "development_system_v3",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:edge_gateway:0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "edge_gateway",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:gateway:0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "gateway",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:hmi_sl:0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hmi_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-5751",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-04T14:51:51.731368Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:28:31.539Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:07:32.848Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2024-027"
},
{
"tags": [
"x_transferred"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18354\u0026token=f3e92a942c3a2f90c272a5ded7598c6a0b5f4924\u0026download="
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Development System V3",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Edge Gateway for Windows",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Gateway for Windows",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "joker63"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A local attacker with low privileges can read and modify any users files and cause a DoS in the working directory of the affected products due to exposure of resource to wrong sphere.\u0026nbsp;\u003cbr\u003e"
}
],
"value": "A local attacker with low privileges can read and modify any users files and cause a DoS in the working directory of the affected products due to exposure of resource to wrong sphere.\u00a0\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-668",
"description": "CWE-668 Exposure of Resource to Wrong Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T08:54:22.046Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-027"
},
{
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18354\u0026token=f3e92a942c3a2f90c272a5ded7598c6a0b5f4924\u0026download="
}
],
"source": {
"advisory": "VDE-2024-027",
"defect": [
"CERT@VDE#64603"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS: Development system prone to DoS through exposure of resource to wrong sphere",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-5751",
"datePublished": "2024-06-04T08:54:22.046Z",
"dateReserved": "2023-10-24T11:46:25.505Z",
"dateUpdated": "2024-08-02T08:07:32.848Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5000 (GCVE-0-2024-5000)
Vulnerability from cvelistv5 – Published: 2024-06-04 08:54 – Updated: 2024-08-01 20:55
VLAI
Title
CODESYS: Incorrect calculation of buffer size can cause DoS on CODESYS OPC UA products
Summary
An unauthenticated remote attacker can use a malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-131 - Incorrect Calculation of Buffer Size
Assigner
References
Impacted products
29 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| codesys | control_for_empc-a\/imx6_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_empc-a\/imx6_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_beaglebone_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_iot2000_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_linux_arm_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_linux_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_pfc200_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_plcnext_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_raspberry_pi_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_wago_touch_panels_600_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_rte_\(for_beckhoff_cx\)_sl |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:control_rte_\(for_beckhoff_cx\)_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_rte_\(sl\) |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:control_rte_\(sl\):*:*:*:*:*:*:*:* |
|
| codesys | control_win_\(sl\) |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:control_win_\(sl\):*:*:*:*:*:*:*:* |
|
| codesys | runtime_toolkit |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:* |
|
| codesys | hmi_\(sl\) |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:hmi_\(sl\):*:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_empc-a\\/imx6_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_beaglebone_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_iot2000_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_linux_arm_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_linux_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_pfc200_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_plcnext_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_raspberry_pi_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_wago_touch_panels_600_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(for_beckhoff_cx\\)_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(for_beckhoff_cx\\)_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_win_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_win_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:hmi_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hmi_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5000",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-06T14:26:44.507505Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T14:44:44.216Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.389Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2024-026"
},
{
"tags": [
"x_transferred"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18355\u0026token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1\u0026download="
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ABB Schweiz AG."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can use a\u0026nbsp;malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker can use a\u00a0malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-131",
"description": "CWE-131 Incorrect Calculation of Buffer Size",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T08:54:06.522Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-026"
},
{
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18355\u0026token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1\u0026download="
}
],
"source": {
"advisory": "VDE-2024-026",
"defect": [
"CERT@VDE#641630"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS: Incorrect calculation of buffer size can cause DoS on CODESYS OPC UA products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-5000",
"datePublished": "2024-06-04T08:54:06.522Z",
"dateReserved": "2024-05-16T12:09:56.937Z",
"dateUpdated": "2024-08-01T20:55:10.389Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-4046 (GCVE-0-2022-4046)
Vulnerability from cvelistv5 – Published: 2023-08-03 12:39 – Updated: 2026-05-29 14:06
VLAI
Title
CODESYS: Improper memory restrictions fro CODESYS Control
Summary
In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
References
1 reference
Impacted products
14 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
all
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
all
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
all
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
all
|
|
| CODESYS | CODESYS Control Runtime System Toolkit |
Affected:
all
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
all
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
all
|
Date Public
2023-08-03 10:30
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:27:54.486Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-025/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-4046",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T14:06:27.478239Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T14:06:35.326Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control Runtime System Toolkit",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
},
{
"defaultStatus": "affected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"datePublic": "2023-08-03T10:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device."
}
],
"value": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-03T12:39:44.002Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-025/"
}
],
"source": {
"defect": [
"CERT@VDE#64299"
],
"discovery": "EXTERNAL"
},
"title": "CODESYS: Improper memory restrictions fro CODESYS Control",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-4046",
"datePublished": "2023-08-03T12:39:44.002Z",
"dateReserved": "2022-11-17T07:07:09.714Z",
"dateUpdated": "2026-05-29T14:06:35.326Z",
"state": "PUBLISHED"
},