Search criteria
20 vulnerabilities found for CODESYS Control for Linux ARM SL by CODESYS
CVE-2026-8047 (GCVE-0-2026-8047)
Vulnerability from nvd – Published: 2026-05-26 06:49 – Updated: 2026-05-26 10:48
VLAI
Title
Out-of-bounds Write in CODESYS Control
Summary
The affected products perform improper length checking when parsing incoming HTTP requests, resulting in a size-limited out-of-bounds write. An unauthenticated remote attacker can exploit this flaw to cause a denial of service via a system crash on the affected device.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-1284 - Improper Validation of Specified Quantity in Input
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-8047",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T10:45:06.909963Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T10:48:24.087Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_rte_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_rte_for_beckhoff_cx_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_win_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_hmi_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_runtime_toolkit:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_empc_a_imx6_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_linux_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_virtual_control_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The affected products perform improper length checking when parsing incoming HTTP requests, resulting in a size-limited out-of-bounds write. An unauthenticated remote attacker can exploit this flaw to cause a denial of service via a system crash on the affected device."
}
],
"value": "The affected products perform improper length checking when parsing incoming HTTP requests, resulting in a size-limited out-of-bounds write. An unauthenticated remote attacker can exploit this flaw to cause a denial of service via a system crash on the affected device."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1284",
"description": "CWE-1284 Improper Validation of Specified Quantity in Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T06:49:54.813Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.certvde.com/en/advisories/VDE-2026-057/"
}
],
"source": {
"advisory": "VDE-2026-057",
"defect": [
"CERT@VDE#642073"
],
"discovery": "UNKNOWN"
},
"title": "Out-of-bounds Write in CODESYS Control",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2026-8047",
"datePublished": "2026-05-26T06:49:54.813Z",
"dateReserved": "2026-05-06T17:12:05.142Z",
"dateUpdated": "2026-05-26T10:48:24.087Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-8046 (GCVE-0-2026-8046)
Vulnerability from nvd – Published: 2026-05-26 06:45 – Updated: 2026-05-26 10:48
VLAI
Title
Incorrect Authorization in CODESYS Control
Summary
The affected products insufficiently verify authorization when deleting user accounts. An authenticated, low-privileged remote user can exploit this vulnerability to delete other users, including those with higher privileges.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-8046",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T10:44:58.318097Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T10:48:37.908Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_rte_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_rte_for_beckhoff_cx_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_win_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_hmi_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_runtime_toolkit:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_empc_a_imx6_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_linux_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_virtual_control_sl_:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "ABB AG"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The affected products insufficiently verify authorization when deleting user accounts. An authenticated, low-privileged remote user can exploit this vulnerability to delete other users, including those with higher privileges."
}
],
"value": "The affected products insufficiently verify authorization when deleting user accounts. An authenticated, low-privileged remote user can exploit this vulnerability to delete other users, including those with higher privileges."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863 Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T06:46:47.189Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.certvde.com/en/advisories/VDE-2026-056/"
}
],
"source": {
"advisory": "VDE-2026-056",
"defect": [
"CERT@VDE#642072"
],
"discovery": "UNKNOWN"
},
"title": "Incorrect Authorization in CODESYS Control",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2026-8046",
"datePublished": "2026-05-26T06:45:21.724Z",
"dateReserved": "2026-05-06T17:10:12.759Z",
"dateUpdated": "2026-05-26T10:48:37.908Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3509 (GCVE-0-2026-3509)
Vulnerability from nvd – Published: 2026-03-24 07:42 – Updated: 2026-03-26 12:35
VLAI
Title
CODESYS Control Audit Log Format String DoS
Summary
An unauthenticated remote attacker may be able to control the format string of messages processed by the Audit Log of the CODESYS Control runtime system, potentially resulting in a denial‑of‑service (DoS) condition.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-134 - Use of Externally-Controlled Format String
Assigner
References
1 reference
Impacted products
15 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
3.5.17.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
3.5.17.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
3.5.17.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
3.5.17.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3509",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-26T12:35:33.893071Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-26T12:35:48.666Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "3.5.17.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "3.5.17.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "3.5.17.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "3.5.17.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker may be able to control the format string of messages processed by the Audit Log of the CODESYS Control runtime system, potentially resulting in a denial\u2011of\u2011service (DoS) condition.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker may be able to control the format string of messages processed by the Audit Log of the CODESYS Control runtime system, potentially resulting in a denial\u2011of\u2011service (DoS) condition."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-134",
"description": "CWE-134 Use of Externally-Controlled Format String",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-24T07:42:33.820Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2026-018"
}
],
"source": {
"advisory": "VDE-2026-018",
"defect": [
"CERT@VDE#641968"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control Audit Log Format String DoS",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2026-3509",
"datePublished": "2026-03-24T07:42:33.820Z",
"dateReserved": "2026-03-04T09:24:19.745Z",
"dateUpdated": "2026-03-26T12:35:48.666Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41660 (GCVE-0-2025-41660)
Vulnerability from nvd – Published: 2026-03-24 07:41 – Updated: 2026-03-24 13:16
VLAI
Title
CODESYS Control Boot Application Replacement Enables Code Execution
Summary
A low-privileged remote attacker may be able to replace the boot application of the CODESYS Control runtime system, enabling unauthorized code execution.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-669 - Incorrect Resource Transfer Between Spheres
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41660",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-24T13:15:49.570572Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-24T13:16:02.920Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Luca Borzacchiello from Nozomi Networks"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A low-privileged remote attacker may be able to replace the boot application of the CODESYS Control runtime system, enabling unauthorized code execution.\u003cbr\u003e"
}
],
"value": "A low-privileged remote attacker may be able to replace the boot application of the CODESYS Control runtime system, enabling unauthorized code execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-669",
"description": "CWE-669 Incorrect Resource Transfer Between Spheres",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-24T07:41:43.004Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2026-011"
}
],
"source": {
"advisory": "VDE-2026-011",
"defect": [
"CERT@VDE#641802"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control Boot Application Replacement Enables Code Execution",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41660",
"datePublished": "2026-03-24T07:41:43.004Z",
"dateReserved": "2025-04-16T11:17:48.307Z",
"dateUpdated": "2026-03-24T13:16:02.920Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41739 (GCVE-0-2025-41739)
Vulnerability from nvd – Published: 2025-12-01 10:00 – Updated: 2026-01-07 17:09
VLAI
Title
CODESYS Control - Linux/QNX SysSocket flaw
Summary
An unauthenticated remote attacker, who beats a race condition, can exploit a flaw in the communication servers of the CODESYS Control runtime system on Linux and QNX to trigger an out-of-bounds read via crafted socket communication, potentially causing a denial of service.
Severity
5.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS PLCHandler |
Affected:
3.5.21.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Remote Target Visu |
Affected:
3.5.21.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
3.5.21.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Edge Gateway for Linux |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS TargetVisu for Linux SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41739",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-01T14:03:10.321003Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-07T17:09:52.535Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS PLCHandler",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Remote Target Visu",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Edge Gateway for Linux",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS TargetVisu for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ABB AG"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker, who beats a race condition, can exploit a flaw in the communication servers of the CODESYS Control runtime system on Linux and QNX to trigger an out-of-bounds read via crafted socket communication, potentially causing a denial of service.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker, who beats a race condition, can exploit a flaw in the communication servers of the CODESYS Control runtime system on Linux and QNX to trigger an out-of-bounds read via crafted socket communication, potentially causing a denial of service."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-01T10:00:44.373Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-099"
}
],
"source": {
"advisory": "VDE-2025-099",
"defect": [
"CERT@VDE#641888"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control - Linux/QNX SysSocket flaw",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41739",
"datePublished": "2025-12-01T10:00:44.373Z",
"dateReserved": "2025-04-16T11:17:48.320Z",
"dateUpdated": "2026-01-07T17:09:52.535Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41738 (GCVE-0-2025-41738)
Vulnerability from nvd – Published: 2025-12-01 10:02 – Updated: 2025-12-01 14:00
VLAI
Title
CODESYS Control - Invalid type usage in visualization
Summary
An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Assigner
References
1 reference
Impacted products
17 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Remote Target Visu |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41738",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-01T13:59:44.375519Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-01T14:00:28.509Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Remote Target Visu",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-843",
"description": "CWE-843 Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-01T10:02:33.407Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-100"
}
],
"source": {
"advisory": "VDE-2025-100",
"defect": [
"CERT@VDE#641889"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control - Invalid type usage in visualization",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41738",
"datePublished": "2025-12-01T10:02:33.407Z",
"dateReserved": "2025-04-16T11:17:48.320Z",
"dateUpdated": "2025-12-01T14:00:28.509Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-0694 (GCVE-0-2025-0694)
Vulnerability from nvd – Published: 2025-03-18 11:04 – Updated: 2025-03-18 13:09
VLAI
Title
CODESYS Control V3 removable media path traversal
Summary
Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access.
Severity
6.6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
Impacted products
15 products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0694",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-18T13:09:24.499918Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T13:09:54.473Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "D. Blagojevic, S.Dietz and T. Weber from CyberDanube"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access."
}
],
"value": "Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T11:04:06.167Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2025-015"
}
],
"source": {
"advisory": "VDE-2025-015",
"defect": [
"CERT@VDE#641743"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control V3 removable media path traversal",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-0694",
"datePublished": "2025-03-18T11:04:06.167Z",
"dateReserved": "2025-01-24T08:27:09.159Z",
"dateUpdated": "2025-03-18T13:09:54.473Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-8175 (GCVE-0-2024-8175)
Vulnerability from nvd – Published: 2024-09-25 08:04 – Updated: 2024-09-25 14:02
VLAI
Title
CODESYS: web server vulnerable to DoS
Summary
An unauthenticated remote attacker can causes the CODESYS web server to access invalid memory which results in a DoS.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://cert.vde.com/en/advisories/VDE-2024-057 | |
| https://customers.codesys.com/index.php?eID=dumpF… | vendor-advisory |
Impacted products
22 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Embedded Target Visu Toolkit |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Remote Target Visu Toolkit |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| codesys | runtime_toolkit |
Affected:
0 , < 4.14.0.0
(custom)
cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_empc-a\/imx6_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_rte_\(for_beckhoff_cx\)_sl |
Affected:
0 , < 3.5.20.30
(custom)
cpe:2.3:a:codesys:control_rte_\(for_beckhoff_cx\)_sl:*:*:*:*:*:*:*:* |
|
| codesys | virtual_control_sl |
Affected:
0 , < 4.14.0.0
(custom)
cpe:2.3:a:codesys:virtual_control_sl:*:*:*:*:*:*:*:* |
|
| codesys | runtime_toolkit |
Affected:
0 , < 3.5.20.30
(custom)
cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(for_beckhoff_cx\\)_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(for_beckhoff_cx\\)_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:virtual_control_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "virtual_control_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8175",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-25T13:44:03.391474Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-25T14:02:28.368Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Embedded Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Remote Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ABB"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can\u0026nbsp;causes the CODESYS web server to access invalid memory which results in a DoS."
}
],
"value": "An unauthenticated remote attacker can\u00a0causes the CODESYS web server to access invalid memory which results in a DoS."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-25T13:33:10.408Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-057"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download="
}
],
"source": {
"advisory": "VDE-2024-057",
"defect": [
"CERT@VDE#641681"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS: web server vulnerable to DoS",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-8175",
"datePublished": "2024-09-25T08:04:23.196Z",
"dateReserved": "2024-08-26T09:58:34.794Z",
"dateUpdated": "2024-09-25T14:02:28.368Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5000 (GCVE-0-2024-5000)
Vulnerability from nvd – Published: 2024-06-04 08:54 – Updated: 2024-08-01 20:55
VLAI
Title
CODESYS: Incorrect calculation of buffer size can cause DoS on CODESYS OPC UA products
Summary
An unauthenticated remote attacker can use a malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-131 - Incorrect Calculation of Buffer Size
Assigner
References
Impacted products
29 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| codesys | control_for_empc-a\/imx6_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_empc-a\/imx6_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_beaglebone_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_iot2000_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_linux_arm_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_linux_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_pfc200_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_plcnext_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_raspberry_pi_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_wago_touch_panels_600_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_rte_\(for_beckhoff_cx\)_sl |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:control_rte_\(for_beckhoff_cx\)_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_rte_\(sl\) |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:control_rte_\(sl\):*:*:*:*:*:*:*:* |
|
| codesys | control_win_\(sl\) |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:control_win_\(sl\):*:*:*:*:*:*:*:* |
|
| codesys | runtime_toolkit |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:* |
|
| codesys | hmi_\(sl\) |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:hmi_\(sl\):*:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_empc-a\\/imx6_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_beaglebone_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_iot2000_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_linux_arm_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_linux_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_pfc200_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_plcnext_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_raspberry_pi_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_wago_touch_panels_600_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(for_beckhoff_cx\\)_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(for_beckhoff_cx\\)_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_win_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_win_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:hmi_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hmi_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5000",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-06T14:26:44.507505Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T14:44:44.216Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.389Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2024-026"
},
{
"tags": [
"x_transferred"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18355\u0026token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1\u0026download="
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ABB Schweiz AG."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can use a\u0026nbsp;malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker can use a\u00a0malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-131",
"description": "CWE-131 Incorrect Calculation of Buffer Size",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T08:54:06.522Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-026"
},
{
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18355\u0026token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1\u0026download="
}
],
"source": {
"advisory": "VDE-2024-026",
"defect": [
"CERT@VDE#641630"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS: Incorrect calculation of buffer size can cause DoS on CODESYS OPC UA products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-5000",
"datePublished": "2024-06-04T08:54:06.522Z",
"dateReserved": "2024-05-16T12:09:56.937Z",
"dateUpdated": "2024-08-01T20:55:10.389Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-6357 (GCVE-0-2023-6357)
Vulnerability from nvd – Published: 2023-12-05 14:29 – Updated: 2024-08-02 08:28
VLAI
Title
OS Command Injection in multiple CODESYS products
Summary
A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device.
Severity
8.8 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
Impacted products
11 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit for Linux or QNX |
Affected:
0 , < 3.5.19.50
(semver)
|
Date Public
2023-12-05 14:25
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:28:21.783Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit for Linux or QNX",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.50",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Chuya Hayakawa of 00One, Inc."
}
],
"datePublic": "2023-12-05T14:25:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device."
}
],
"value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-05T14:29:25.649Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
}
],
"source": {
"advisory": "VDE-2023-066",
"defect": [
"CERT@VDE#64623"
],
"discovery": "UNKNOWN"
},
"title": "OS Command Injection in multiple CODESYS products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-6357",
"datePublished": "2023-12-05T14:29:25.649Z",
"dateReserved": "2023-11-28T07:20:59.774Z",
"dateUpdated": "2024-08-02T08:28:21.783Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-8047 (GCVE-0-2026-8047)
Vulnerability from cvelistv5 – Published: 2026-05-26 06:49 – Updated: 2026-05-26 10:48
VLAI
Title
Out-of-bounds Write in CODESYS Control
Summary
The affected products perform improper length checking when parsing incoming HTTP requests, resulting in a size-limited out-of-bounds write. An unauthenticated remote attacker can exploit this flaw to cause a denial of service via a system crash on the affected device.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-1284 - Improper Validation of Specified Quantity in Input
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
3.5.21.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
4.15.0.0 , < 4.21.0.0
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-8047",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T10:45:06.909963Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T10:48:24.087Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_rte_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_rte_for_beckhoff_cx_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_win_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_hmi_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_runtime_toolkit:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.5.21.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_empc_a_imx6_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_linux_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_virtual_control_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "4.15.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The affected products perform improper length checking when parsing incoming HTTP requests, resulting in a size-limited out-of-bounds write. An unauthenticated remote attacker can exploit this flaw to cause a denial of service via a system crash on the affected device."
}
],
"value": "The affected products perform improper length checking when parsing incoming HTTP requests, resulting in a size-limited out-of-bounds write. An unauthenticated remote attacker can exploit this flaw to cause a denial of service via a system crash on the affected device."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1284",
"description": "CWE-1284 Improper Validation of Specified Quantity in Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T06:49:54.813Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.certvde.com/en/advisories/VDE-2026-057/"
}
],
"source": {
"advisory": "VDE-2026-057",
"defect": [
"CERT@VDE#642073"
],
"discovery": "UNKNOWN"
},
"title": "Out-of-bounds Write in CODESYS Control",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2026-8047",
"datePublished": "2026-05-26T06:49:54.813Z",
"dateReserved": "2026-05-06T17:12:05.142Z",
"dateUpdated": "2026-05-26T10:48:24.087Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-8046 (GCVE-0-2026-8046)
Vulnerability from cvelistv5 – Published: 2026-05-26 06:45 – Updated: 2026-05-26 10:48
VLAI
Title
Incorrect Authorization in CODESYS Control
Summary
The affected products insufficiently verify authorization when deleting user accounts. An authenticated, low-privileged remote user can exploit this vulnerability to delete other users, including those with higher privileges.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
3.0.0.0 , < 3.5.22.20
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
3.0.0.0 , < 4.21.0.0
(semver)
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-8046",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-26T10:44:58.318097Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T10:48:37.908Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.20",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "3.0.0.0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_rte_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_rte_for_beckhoff_cx_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_win_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_hmi_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_runtime_toolkit:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.5.22.20",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_empc_a_imx6_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_linux_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:codesys:codesys_virtual_control_sl_:*:*:*:*:*:*:*:*",
"versionEndExcluding": "4.21.0.0",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "ABB AG"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The affected products insufficiently verify authorization when deleting user accounts. An authenticated, low-privileged remote user can exploit this vulnerability to delete other users, including those with higher privileges."
}
],
"value": "The affected products insufficiently verify authorization when deleting user accounts. An authenticated, low-privileged remote user can exploit this vulnerability to delete other users, including those with higher privileges."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863 Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-26T06:46:47.189Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.certvde.com/en/advisories/VDE-2026-056/"
}
],
"source": {
"advisory": "VDE-2026-056",
"defect": [
"CERT@VDE#642072"
],
"discovery": "UNKNOWN"
},
"title": "Incorrect Authorization in CODESYS Control",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2026-8046",
"datePublished": "2026-05-26T06:45:21.724Z",
"dateReserved": "2026-05-06T17:10:12.759Z",
"dateUpdated": "2026-05-26T10:48:37.908Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-3509 (GCVE-0-2026-3509)
Vulnerability from cvelistv5 – Published: 2026-03-24 07:42 – Updated: 2026-03-26 12:35
VLAI
Title
CODESYS Control Audit Log Format String DoS
Summary
An unauthenticated remote attacker may be able to control the format string of messages processed by the Audit Log of the CODESYS Control runtime system, potentially resulting in a denial‑of‑service (DoS) condition.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-134 - Use of Externally-Controlled Format String
Assigner
References
1 reference
Impacted products
15 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
3.5.17.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
3.5.17.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
3.5.17.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
3.5.17.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
4.1.0.0 , < 4.21.0.0
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3509",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-26T12:35:33.893071Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-26T12:35:48.666Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "3.5.17.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "3.5.17.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "3.5.17.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "3.5.17.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "4.1.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker may be able to control the format string of messages processed by the Audit Log of the CODESYS Control runtime system, potentially resulting in a denial\u2011of\u2011service (DoS) condition.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker may be able to control the format string of messages processed by the Audit Log of the CODESYS Control runtime system, potentially resulting in a denial\u2011of\u2011service (DoS) condition."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-134",
"description": "CWE-134 Use of Externally-Controlled Format String",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-24T07:42:33.820Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2026-018"
}
],
"source": {
"advisory": "VDE-2026-018",
"defect": [
"CERT@VDE#641968"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control Audit Log Format String DoS",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2026-3509",
"datePublished": "2026-03-24T07:42:33.820Z",
"dateReserved": "2026-03-04T09:24:19.745Z",
"dateUpdated": "2026-03-26T12:35:48.666Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41660 (GCVE-0-2025-41660)
Vulnerability from cvelistv5 – Published: 2026-03-24 07:41 – Updated: 2026-03-24 13:16
VLAI
Title
CODESYS Control Boot Application Replacement Enables Code Execution
Summary
A low-privileged remote attacker may be able to replace the boot application of the CODESYS Control runtime system, enabling unauthorized code execution.
Severity
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-669 - Incorrect Resource Transfer Between Spheres
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
0.0.0 , < 3.5.22.0
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
0.0.0 , < 4.21.0.0
(semver)
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41660",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-24T13:15:49.570572Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-24T13:16:02.920Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.22.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.21.0.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Luca Borzacchiello from Nozomi Networks"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A low-privileged remote attacker may be able to replace the boot application of the CODESYS Control runtime system, enabling unauthorized code execution.\u003cbr\u003e"
}
],
"value": "A low-privileged remote attacker may be able to replace the boot application of the CODESYS Control runtime system, enabling unauthorized code execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-669",
"description": "CWE-669 Incorrect Resource Transfer Between Spheres",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-24T07:41:43.004Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2026-011"
}
],
"source": {
"advisory": "VDE-2026-011",
"defect": [
"CERT@VDE#641802"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control Boot Application Replacement Enables Code Execution",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41660",
"datePublished": "2026-03-24T07:41:43.004Z",
"dateReserved": "2025-04-16T11:17:48.307Z",
"dateUpdated": "2026-03-24T13:16:02.920Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41738 (GCVE-0-2025-41738)
Vulnerability from cvelistv5 – Published: 2025-12-01 10:02 – Updated: 2025-12-01 14:00
VLAI
Title
CODESYS Control - Invalid type usage in visualization
Summary
An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Assigner
References
1 reference
Impacted products
17 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Remote Target Visu |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
3.5.18.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
4.5.0.0 , < 4.19.0.0
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41738",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-01T13:59:44.375519Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-01T14:00:28.509Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Remote Target Visu",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.18.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.5.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker may cause the visualisation server of the CODESYS Control runtime system to access a resource with a pointer of wrong type, potentially leading to a denial-of-service (DoS) condition."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-843",
"description": "CWE-843 Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-01T10:02:33.407Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-100"
}
],
"source": {
"advisory": "VDE-2025-100",
"defect": [
"CERT@VDE#641889"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control - Invalid type usage in visualization",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41738",
"datePublished": "2025-12-01T10:02:33.407Z",
"dateReserved": "2025-04-16T11:17:48.320Z",
"dateUpdated": "2025-12-01T14:00:28.509Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41739 (GCVE-0-2025-41739)
Vulnerability from cvelistv5 – Published: 2025-12-01 10:00 – Updated: 2026-01-07 17:09
VLAI
Title
CODESYS Control - Linux/QNX SysSocket flaw
Summary
An unauthenticated remote attacker, who beats a race condition, can exploit a flaw in the communication servers of the CODESYS Control runtime system on Linux and QNX to trigger an out-of-bounds read via crafted socket communication, potentially causing a denial of service.
Severity
5.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
1 reference
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS PLCHandler |
Affected:
3.5.21.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Remote Target Visu |
Affected:
3.5.21.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
3.5.21.0 , < 3.5.21.40
(semver)
|
|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Edge Gateway for Linux |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS TargetVisu for Linux SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
4.15.0.0 , < 4.19.0.0
(semver)
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41739",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-01T14:03:10.321003Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-07T17:09:52.535Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS PLCHandler",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Remote Target Visu",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.40",
"status": "affected",
"version": "3.5.21.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Edge Gateway for Linux",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS TargetVisu for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.19.0.0",
"status": "affected",
"version": "4.15.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ABB AG"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker, who beats a race condition, can exploit a flaw in the communication servers of the CODESYS Control runtime system on Linux and QNX to trigger an out-of-bounds read via crafted socket communication, potentially causing a denial of service.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker, who beats a race condition, can exploit a flaw in the communication servers of the CODESYS Control runtime system on Linux and QNX to trigger an out-of-bounds read via crafted socket communication, potentially causing a denial of service."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-01T10:00:44.373Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/de/advisories/VDE-2025-099"
}
],
"source": {
"advisory": "VDE-2025-099",
"defect": [
"CERT@VDE#641888"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control - Linux/QNX SysSocket flaw",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41739",
"datePublished": "2025-12-01T10:00:44.373Z",
"dateReserved": "2025-04-16T11:17:48.320Z",
"dateUpdated": "2026-01-07T17:09:52.535Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-0694 (GCVE-0-2025-0694)
Vulnerability from cvelistv5 – Published: 2025-03-18 11:04 – Updated: 2025-03-18 13:09
VLAI
Title
CODESYS Control V3 removable media path traversal
Summary
Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access.
Severity
6.6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
Impacted products
15 products
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0694",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-18T13:09:24.499918Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T13:09:54.473Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.21.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.16.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "D. Blagojevic, S.Dietz and T. Weber from CyberDanube"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access."
}
],
"value": "Insufficient path validation in CODESYS Control allows low privileged attackers with physical access to gain full filesystem access."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-18T11:04:06.167Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2025-015"
}
],
"source": {
"advisory": "VDE-2025-015",
"defect": [
"CERT@VDE#641743"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS Control V3 removable media path traversal",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-0694",
"datePublished": "2025-03-18T11:04:06.167Z",
"dateReserved": "2025-01-24T08:27:09.159Z",
"dateUpdated": "2025-03-18T13:09:54.473Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-8175 (GCVE-0-2024-8175)
Vulnerability from cvelistv5 – Published: 2024-09-25 08:04 – Updated: 2024-09-25 14:02
VLAI
Title
CODESYS: web server vulnerable to DoS
Summary
An unauthenticated remote attacker can causes the CODESYS web server to access invalid memory which results in a DoS.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://cert.vde.com/en/advisories/VDE-2024-057 | |
| https://customers.codesys.com/index.php?eID=dumpF… | vendor-advisory |
Impacted products
22 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Embedded Target Visu Toolkit |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Remote Target Visu Toolkit |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
0 , < 3.5.20.30
(semver)
|
|
| CODESYS | CODESYS Virtual Control SL |
Affected:
0 , < 4.14.0.0
(semver)
|
|
| codesys | runtime_toolkit |
Affected:
0 , < 4.14.0.0
(custom)
cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_empc-a\/imx6_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_rte_\(for_beckhoff_cx\)_sl |
Affected:
0 , < 3.5.20.30
(custom)
cpe:2.3:a:codesys:control_rte_\(for_beckhoff_cx\)_sl:*:*:*:*:*:*:*:* |
|
| codesys | virtual_control_sl |
Affected:
0 , < 4.14.0.0
(custom)
cpe:2.3:a:codesys:virtual_control_sl:*:*:*:*:*:*:*:* |
|
| codesys | runtime_toolkit |
Affected:
0 , < 3.5.20.30
(custom)
cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:* cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(for_beckhoff_cx\\)_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(for_beckhoff_cx\\)_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:virtual_control_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "virtual_control_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:embedded_target_visu_toolkit:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:remote_target_visu_toolkit:*:*:*:*:*:*:*:*",
"cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-8175",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-25T13:44:03.391474Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-25T14:02:28.368Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Embedded Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Remote Target Visu Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.30",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Virtual Control SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.14.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ABB"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can\u0026nbsp;causes the CODESYS web server to access invalid memory which results in a DoS."
}
],
"value": "An unauthenticated remote attacker can\u00a0causes the CODESYS web server to access invalid memory which results in a DoS."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-25T13:33:10.408Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-057"
},
{
"tags": [
"vendor-advisory"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18604\u0026token=d5e1e2820ee63077b875b3bb41014b1f102e88a3\u0026download="
}
],
"source": {
"advisory": "VDE-2024-057",
"defect": [
"CERT@VDE#641681"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS: web server vulnerable to DoS",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-8175",
"datePublished": "2024-09-25T08:04:23.196Z",
"dateReserved": "2024-08-26T09:58:34.794Z",
"dateUpdated": "2024-09-25T14:02:28.368Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5000 (GCVE-0-2024-5000)
Vulnerability from cvelistv5 – Published: 2024-06-04 08:54 – Updated: 2024-08-01 20:55
VLAI
Title
CODESYS: Incorrect calculation of buffer size can cause DoS on CODESYS OPC UA products
Summary
An unauthenticated remote attacker can use a malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-131 - Incorrect Calculation of Buffer Size
Assigner
References
Impacted products
29 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < 4.12.0.0
(semver)
|
|
| CODESYS | CODESYS Control RTE (for Beckhoff CX) SL |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Control RTE (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS Control Win (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| CODESYS | CODESYS HMI (SL) |
Affected:
0 , < 3.5.20.10
(semver)
|
|
| codesys | control_for_empc-a\/imx6_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_empc-a\/imx6_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_beaglebone_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_iot2000_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_linux_arm_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_linux_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_pfc200_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_plcnext_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_raspberry_pi_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_for_wago_touch_panels_600_sl |
Affected:
0 , < 4.12.0.0
(custom)
cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_rte_\(for_beckhoff_cx\)_sl |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:control_rte_\(for_beckhoff_cx\)_sl:*:*:*:*:*:*:*:* |
|
| codesys | control_rte_\(sl\) |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:control_rte_\(sl\):*:*:*:*:*:*:*:* |
|
| codesys | control_win_\(sl\) |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:control_win_\(sl\):*:*:*:*:*:*:*:* |
|
| codesys | runtime_toolkit |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:* |
|
| codesys | hmi_\(sl\) |
Affected:
0 , < 3.5.20.10
(custom)
cpe:2.3:a:codesys:hmi_\(sl\):*:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_empc-a\\/imx6_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_beaglebone_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_iot2000_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_linux_arm_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_linux_arm_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_linux_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_pfc200_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_plcnext_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_raspberry_pi_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_for_wago_touch_panels_600_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(for_beckhoff_cx\\)_sl:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(for_beckhoff_cx\\)_sl",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_rte_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_rte_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:control_win_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "control_win_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:runtime_toolkit:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "runtime_toolkit",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:codesys:hmi_\\(sl\\):*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "hmi_\\(sl\\)",
"vendor": "codesys",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5000",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-06T14:26:44.507505Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T14:44:44.216Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:55:10.389Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2024-026"
},
{
"tags": [
"x_transferred"
],
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18355\u0026token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1\u0026download="
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.12.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (for Beckhoff CX) SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control RTE (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control Win (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS HMI (SL)",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.20.10",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ABB Schweiz AG."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can use a\u0026nbsp;malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker can use a\u00a0malicious OPC UA client to send a crafted request to affected CODESYS products which can cause a DoS due to incorrect calculation of buffer size.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-131",
"description": "CWE-131 Incorrect Calculation of Buffer Size",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T08:54:06.522Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-026"
},
{
"url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=18355\u0026token=e3e5a937ce72602bec39718ddc2f4ba6d983ccd1\u0026download="
}
],
"source": {
"advisory": "VDE-2024-026",
"defect": [
"CERT@VDE#641630"
],
"discovery": "UNKNOWN"
},
"title": "CODESYS: Incorrect calculation of buffer size can cause DoS on CODESYS OPC UA products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-5000",
"datePublished": "2024-06-04T08:54:06.522Z",
"dateReserved": "2024-05-16T12:09:56.937Z",
"dateUpdated": "2024-08-01T20:55:10.389Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-6357 (GCVE-0-2023-6357)
Vulnerability from cvelistv5 – Published: 2023-12-05 14:29 – Updated: 2024-08-02 08:28
VLAI
Title
OS Command Injection in multiple CODESYS products
Summary
A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device.
Severity
8.8 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
Impacted products
11 products
| Vendor | Product | Version | |
|---|---|---|---|
| CODESYS | CODESYS Control for BeagleBone SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for emPC-A/iMX6 SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for IOT2000 SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux ARM SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Linux SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC100 SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PFC200 SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for PLCnext SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for Raspberry Pi SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Control for WAGO Touch Panels 600 SL |
Affected:
0 , < 4.11.0.0
(semver)
|
|
| CODESYS | CODESYS Runtime Toolkit for Linux or QNX |
Affected:
0 , < 3.5.19.50
(semver)
|
Date Public
2023-12-05 14:25
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:28:21.783Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for BeagleBone SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for emPC-A/iMX6 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for IOT2000 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux ARM SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Linux SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC100 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PFC200 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for PLCnext SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for Raspberry Pi SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Control for WAGO Touch Panels 600 SL",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "4.11.0.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CODESYS Runtime Toolkit for Linux or QNX",
"vendor": "CODESYS",
"versions": [
{
"lessThan": "3.5.19.50",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Chuya Hayakawa of 00One, Inc."
}
],
"datePublic": "2023-12-05T14:25:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device."
}
],
"value": "A low-privileged remote attacker could exploit the vulnerability and inject additional system commands via file system libraries which could give the attacker full control of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-05T14:29:25.649Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-066"
}
],
"source": {
"advisory": "VDE-2023-066",
"defect": [
"CERT@VDE#64623"
],
"discovery": "UNKNOWN"
},
"title": "OS Command Injection in multiple CODESYS products",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-6357",
"datePublished": "2023-12-05T14:29:25.649Z",
"dateReserved": "2023-11-28T07:20:59.774Z",
"dateUpdated": "2024-08-02T08:28:21.783Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}