Search criteria
17 vulnerabilities found for AXC F 2152 by Phoenix Contact
CVE-2025-41670 (GCVE-0-2025-41670)
Vulnerability from nvd – Published: 2026-05-27 07:17 – Updated: 2026-05-27 12:04- CWE-427 - Uncontrolled Search Path Element
| Vendor | Product | Version | |
|---|---|---|---|
| Phoenix Contact | AXC F 1152 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | AXC F 1252 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | AXC F 2000 EA |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | AXC F 2152 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | AXC F 3152 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | BPC 9102S |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | EPC 1522 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | RFC 4072R |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | RFC 4072S |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VL3 UPC 2440 EDGE |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VPLCNEXT CONTROL 1000 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VPLCNEXT CONTROL 2000 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VPLCNEXT CONTROL 3000 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VPLCNEXT CONTROL 500 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41670",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-27T11:53:31.526293Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T12:04:21.896Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 1252",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2000 EA",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1522",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072R",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VL3 UPC 2440 EDGE",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VPLCNEXT CONTROL 1000",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VPLCNEXT CONTROL 2000",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VPLCNEXT CONTROL 3000",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VPLCNEXT CONTROL 500",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_1152:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_1252:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_2000_ea:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_2152:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_3152:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:bpc_9102s:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:epc_1522:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:rfc_4072r:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:rfc_4072s:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vl3_upc_2440_edge:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vplcnext_control_1000:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vplcnext_control_2000:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vplcnext_control_3000:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vplcnext_control_500:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Diego Giubertoni from Nozomi"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA local user with low privileges may be able to influence the behavior of a privileged system service by manipulating configuration or application-related files located in user-writable areas of the filesystem. The affected service processes data from locations that are not sufficiently protected against modification by low-privileged users. As the service runs with elevated privileges, successful exploitation may result in a local privilege escalation.\u003c/p\u003e"
}
],
"value": "A local user with low privileges may be able to influence the behavior of a privileged system service by manipulating configuration or application-related files located in user-writable areas of the filesystem. The affected service processes data from locations that are not sufficiently protected against modification by low-privileged users. As the service runs with elevated privileges, successful exploitation may result in a local privilege escalation."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T07:17:43.775Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.certvde.com/en/advisories/VDE-2026-050/"
}
],
"source": {
"advisory": "VDE-2026-050",
"defect": [
"CERT@VDE#641839"
],
"discovery": "UNKNOWN"
},
"title": "Untrusted Search Path",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41670",
"datePublished": "2026-05-27T07:17:43.775Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2026-05-27T12:04:21.896Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41669 (GCVE-0-2025-41669)
Vulnerability from nvd – Published: 2026-05-27 07:18 – Updated: 2026-05-27 12:04- CWE-347 - Improper Verification of Cryptographic Signature
| Vendor | Product | Version | |
|---|---|---|---|
| Phoenix Contact | AXC F 1152 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | AXC F 1252 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | AXC F 2000 EA |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | AXC F 2152 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | AXC F 3152 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | BPC 9102S |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | EPC 1522 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | RFC 4072R |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | RFC 4072S |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VL3 UPC 2440 EDGE |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VPLCNEXT CONTROL 1000 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VPLCNEXT CONTROL 2000 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VPLCNEXT CONTROL 3000 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VPLCNEXT CONTROL 500 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41669",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-27T11:53:22.514056Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T12:04:07.823Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 1252",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2000 EA",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1522",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072R",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VL3 UPC 2440 EDGE",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VPLCNEXT CONTROL 1000",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VPLCNEXT CONTROL 2000",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VPLCNEXT CONTROL 3000",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VPLCNEXT CONTROL 500",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_1152:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_1252:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_2000_ea:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_2152:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_3152:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:bpc_9102s:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:epc_1522:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:rfc_4072r:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:rfc_4072s:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vl3_upc_2440_edge:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vplcnext_control_1000:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vplcnext_control_2000:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vplcnext_control_3000:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vplcnext_control_500:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Diego Giubertoni from Nozomi"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Web-based Management allows a remote low privileged Engineer user to install additional APPs on the device downloaded from the PLCnext Store without implementing any data verification mechanism, leading to the capability for an Engineer user to reach arbitrary code execution with root privileges on the PLC device. A successful exploitation may allow to install a manipulated APP package, potentially impacting integrity and availability of the PLCnext Control."
}
],
"value": "The Web-based Management allows a remote low privileged Engineer user to install additional APPs on the device downloaded from the PLCnext Store without implementing any data verification mechanism, leading to the capability for an Engineer user to reach arbitrary code execution with root privileges on the PLC device. A successful exploitation may allow to install a manipulated APP package, potentially impacting integrity and availability of the PLCnext Control."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-347",
"description": "CWE-347 Improper Verification of Cryptographic Signature",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T07:18:28.236Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.certvde.com/en/advisories/VDE-2026-050/"
}
],
"source": {
"advisory": "VDE-2026-050",
"defect": [
"CERT@VDE#641839"
],
"discovery": "UNKNOWN"
},
"title": "Insufficient Verification of Data Authenticity",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41669",
"datePublished": "2026-05-27T07:18:28.236Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2026-05-27T12:04:07.823Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41668 (GCVE-0-2025-41668)
Vulnerability from nvd – Published: 2025-07-08 07:04 – Updated: 2025-07-08 14:28- CWE-59 - Improper Link Resolution Before File Access ('Link Following')
| Vendor | Product | Version | |
|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | AXC F 2152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | AXC F 3152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | BPC 9102S |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | RFC 4072S |
Affected:
0 , < 2025.0.2
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41668",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-08T14:23:22.573108Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T14:28:20.367Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Nozomi"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA low privileged remote attacker with file access can replace a critical file or folder used by the service security-profile to get read, write and execute access to any file on the device.\u003c/p\u003e"
}
],
"value": "A low privileged remote attacker with file access can replace a critical file or folder used by the service security-profile to get read, write and execute access to any file on the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-59",
"description": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T07:04:22.922Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/en/advisories/VDE-2025-054"
}
],
"source": {
"advisory": "VDE-2025-054",
"defect": [
"CERT@VDE#641795"
],
"discovery": "UNKNOWN"
},
"title": "Phoenix Contact: File access due to the replacement of a critical file used by the service security-profile",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41668",
"datePublished": "2025-07-08T07:04:22.922Z",
"dateReserved": "2025-04-16T11:17:48.307Z",
"dateUpdated": "2025-07-08T14:28:20.367Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41667 (GCVE-0-2025-41667)
Vulnerability from nvd – Published: 2025-07-08 07:03 – Updated: 2025-07-08 14:28- CWE-59 - Improper Link Resolution Before File Access ('Link Following')
| Vendor | Product | Version | |
|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | AXC F 2152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | AXC F 3152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | BPC 9102S |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | RFC 4072S |
Affected:
0 , < 2025.0.2
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41667",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-08T14:23:25.430004Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T14:28:29.391Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Nozomi"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A low privileged remote attacker with file access can replace a critical file used by the arp-preinit script to get read, write and execute access to any file on the device."
}
],
"value": "A low privileged remote attacker with file access can replace a critical file used by the arp-preinit script to get read, write and execute access to any file on the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-59",
"description": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T07:04:06.715Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/en/advisories/VDE-2025-054"
}
],
"source": {
"advisory": "VDE-2025-054",
"defect": [
"CERT@VDE#641795"
],
"discovery": "UNKNOWN"
},
"title": "Phoenix Contact: File access due to the replacement of a critical file used by the arp-preinit script",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41667",
"datePublished": "2025-07-08T07:03:50.761Z",
"dateReserved": "2025-04-16T11:17:48.307Z",
"dateUpdated": "2025-07-08T14:28:29.391Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41666 (GCVE-0-2025-41666)
Vulnerability from nvd – Published: 2025-07-08 07:03 – Updated: 2025-07-08 14:28- CWE-59 - Improper Link Resolution Before File Access ('Link Following')
| Vendor | Product | Version | |
|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | AXC F 2152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | AXC F 3152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | BPC 9102S |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | RFC 4072S |
Affected:
0 , < 2025.0.2
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41666",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-08T14:23:28.624235Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T14:28:36.584Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Nozomi"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A low privileged remote attacker with file access can replace a critical file used by the watchdog to get read, write and execute access to any file on the device after the watchdog has been initialized."
}
],
"value": "A low privileged remote attacker with file access can replace a critical file used by the watchdog to get read, write and execute access to any file on the device after the watchdog has been initialized."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-59",
"description": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T07:03:38.410Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/en/advisories/VDE-2025-054"
}
],
"source": {
"advisory": "VDE-2025-054",
"discovery": "UNKNOWN"
},
"title": "Phoenix Contact: File access due to the replacement of a critical file used by the watchdog",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41666",
"datePublished": "2025-07-08T07:03:38.410Z",
"dateReserved": "2025-04-16T11:17:48.307Z",
"dateUpdated": "2025-07-08T14:28:36.584Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41665 (GCVE-0-2025-41665)
Vulnerability from nvd – Published: 2025-07-08 07:03 – Updated: 2025-07-08 14:10- CWE-276 - Incorrect Default Permissions
| Vendor | Product | Version | |
|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | AXC F 2152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | AXC F 3152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | BPC 9102S |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | RFC 4072S |
Affected:
0 , < 2025.0.2
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41665",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-08T14:09:53.864838Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T14:10:19.960Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Nozomi"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn low privileged remote attacker can enforce the watchdog of the affected devices to reboot the PLC due to incorrect default permissions of a config file.\u003c/p\u003e"
}
],
"value": "An low privileged remote attacker can enforce the watchdog of the affected devices to reboot the PLC due to incorrect default permissions of a config file."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276 Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T07:03:26.147Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/en/advisories/VDE-2025-054"
}
],
"source": {
"advisory": "VDE-2025-054",
"defect": [
"CERT@VDE#641795"
],
"discovery": "UNKNOWN"
},
"title": "Phoenix Contact: DoS of the PLC due to incorrect default permissions possible",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41665",
"datePublished": "2025-07-08T07:03:26.147Z",
"dateReserved": "2025-04-16T11:17:48.307Z",
"dateUpdated": "2025-07-08T14:10:19.960Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-46144 (GCVE-0-2023-46144)
Vulnerability from nvd – Published: 2023-12-14 14:08 – Updated: 2024-10-01 06:18- CWE-494 - Download of Code Without Integrity Check
| Vendor | Product | Version | |
|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | AXC F 2152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | AXC F 3152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | BPC 9102S |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | EPC 1502 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | EPC 1522 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | PLCnext Engineer |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | RFC 4072R |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | RFC 4072S |
Affected:
0 , ≤ 2024.0
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:37:39.934Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1502",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1522",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PLCnext Engineer",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072R",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reid Wightman of Dragos, Inc."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
}
],
"value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494: Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-01T06:18:18.730Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"source": {
"advisory": "VDE-2023-058",
"defect": [
"CERT@VDE#64611"
],
"discovery": "EXTERNAL"
},
"title": "PHOENIX CONTACT: PLCnext Control prone to download of code without integrity check",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-46144",
"datePublished": "2023-12-14T14:08:07.244Z",
"dateReserved": "2023-10-17T07:04:03.577Z",
"dateUpdated": "2024-10-01T06:18:18.730Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-46142 (GCVE-0-2023-46142)
Vulnerability from nvd – Published: 2023-12-14 14:05 – Updated: 2024-08-02 20:37- CWE-732 - Incorrect Permission Assignment for Critical Resource
| Vendor | Product | Version | |
|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | AXC F 2152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | AXC F 3152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | BPC 9102S |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | EPC 1502 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | EPC 1522 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | PLCnext Engineer |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | RFC 4072R |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | RFC 4072S |
Affected:
0 , ≤ 2024.0
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:37:39.840Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1502",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1522",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PLCnext Engineer",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072R",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reid Wightman of Dragos, Inc."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
}
],
"value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T14:05:35.741Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"source": {
"advisory": "VDE-2023-056",
"defect": [
"CERT@VDE#64609"
],
"discovery": "EXTERNAL"
},
"title": "PHOENIX CONTACT: Insufficient Read and Write Protection to Logic and Runtime Data in PLCnext Control",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-46142",
"datePublished": "2023-12-14T14:05:35.741Z",
"dateReserved": "2023-10-17T07:04:03.576Z",
"dateUpdated": "2024-08-02T20:37:39.840Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41669 (GCVE-0-2025-41669)
Vulnerability from cvelistv5 – Published: 2026-05-27 07:18 – Updated: 2026-05-27 12:04- CWE-347 - Improper Verification of Cryptographic Signature
| Vendor | Product | Version | |
|---|---|---|---|
| Phoenix Contact | AXC F 1152 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | AXC F 1252 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | AXC F 2000 EA |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | AXC F 2152 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | AXC F 3152 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | BPC 9102S |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | EPC 1522 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | RFC 4072R |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | RFC 4072S |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VL3 UPC 2440 EDGE |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VPLCNEXT CONTROL 1000 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VPLCNEXT CONTROL 2000 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VPLCNEXT CONTROL 3000 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VPLCNEXT CONTROL 500 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41669",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-27T11:53:22.514056Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T12:04:07.823Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 1252",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2000 EA",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1522",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072R",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VL3 UPC 2440 EDGE",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VPLCNEXT CONTROL 1000",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VPLCNEXT CONTROL 2000",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VPLCNEXT CONTROL 3000",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VPLCNEXT CONTROL 500",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_1152:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_1252:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_2000_ea:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_2152:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_3152:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:bpc_9102s:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:epc_1522:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:rfc_4072r:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:rfc_4072s:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vl3_upc_2440_edge:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vplcnext_control_1000:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vplcnext_control_2000:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vplcnext_control_3000:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vplcnext_control_500:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Diego Giubertoni from Nozomi"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Web-based Management allows a remote low privileged Engineer user to install additional APPs on the device downloaded from the PLCnext Store without implementing any data verification mechanism, leading to the capability for an Engineer user to reach arbitrary code execution with root privileges on the PLC device. A successful exploitation may allow to install a manipulated APP package, potentially impacting integrity and availability of the PLCnext Control."
}
],
"value": "The Web-based Management allows a remote low privileged Engineer user to install additional APPs on the device downloaded from the PLCnext Store without implementing any data verification mechanism, leading to the capability for an Engineer user to reach arbitrary code execution with root privileges on the PLC device. A successful exploitation may allow to install a manipulated APP package, potentially impacting integrity and availability of the PLCnext Control."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-347",
"description": "CWE-347 Improper Verification of Cryptographic Signature",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T07:18:28.236Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.certvde.com/en/advisories/VDE-2026-050/"
}
],
"source": {
"advisory": "VDE-2026-050",
"defect": [
"CERT@VDE#641839"
],
"discovery": "UNKNOWN"
},
"title": "Insufficient Verification of Data Authenticity",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41669",
"datePublished": "2026-05-27T07:18:28.236Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2026-05-27T12:04:07.823Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41670 (GCVE-0-2025-41670)
Vulnerability from cvelistv5 – Published: 2026-05-27 07:17 – Updated: 2026-05-27 12:04- CWE-427 - Uncontrolled Search Path Element
| Vendor | Product | Version | |
|---|---|---|---|
| Phoenix Contact | AXC F 1152 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | AXC F 1252 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | AXC F 2000 EA |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | AXC F 2152 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | AXC F 3152 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | BPC 9102S |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | EPC 1522 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | RFC 4072R |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | RFC 4072S |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VL3 UPC 2440 EDGE |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VPLCNEXT CONTROL 1000 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VPLCNEXT CONTROL 2000 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VPLCNEXT CONTROL 3000 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
|
| Phoenix Contact | VPLCNEXT CONTROL 500 |
Affected:
0.0.0 , < 2026.0.3
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41670",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-27T11:53:31.526293Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T12:04:21.896Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 1252",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2000 EA",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1522",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072R",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VL3 UPC 2440 EDGE",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VPLCNEXT CONTROL 1000",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VPLCNEXT CONTROL 2000",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VPLCNEXT CONTROL 3000",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VPLCNEXT CONTROL 500",
"vendor": "Phoenix Contact",
"versions": [
{
"lessThan": "2026.0.3",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_1152:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_1252:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_2000_ea:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_2152:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:axc_f_3152:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:bpc_9102s:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:epc_1522:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:rfc_4072r:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:rfc_4072s:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vl3_upc_2440_edge:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vplcnext_control_1000:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vplcnext_control_2000:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vplcnext_control_3000:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenix_contact:vplcnext_control_500:*:*:*:*:*:*:*:*",
"versionEndExcluding": "2026.0.3",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Diego Giubertoni from Nozomi"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA local user with low privileges may be able to influence the behavior of a privileged system service by manipulating configuration or application-related files located in user-writable areas of the filesystem. The affected service processes data from locations that are not sufficiently protected against modification by low-privileged users. As the service runs with elevated privileges, successful exploitation may result in a local privilege escalation.\u003c/p\u003e"
}
],
"value": "A local user with low privileges may be able to influence the behavior of a privileged system service by manipulating configuration or application-related files located in user-writable areas of the filesystem. The affected service processes data from locations that are not sufficiently protected against modification by low-privileged users. As the service runs with elevated privileges, successful exploitation may result in a local privilege escalation."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T07:17:43.775Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.certvde.com/en/advisories/VDE-2026-050/"
}
],
"source": {
"advisory": "VDE-2026-050",
"defect": [
"CERT@VDE#641839"
],
"discovery": "UNKNOWN"
},
"title": "Untrusted Search Path",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41670",
"datePublished": "2026-05-27T07:17:43.775Z",
"dateReserved": "2025-04-16T11:17:48.308Z",
"dateUpdated": "2026-05-27T12:04:21.896Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41668 (GCVE-0-2025-41668)
Vulnerability from cvelistv5 – Published: 2025-07-08 07:04 – Updated: 2025-07-08 14:28- CWE-59 - Improper Link Resolution Before File Access ('Link Following')
| Vendor | Product | Version | |
|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | AXC F 2152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | AXC F 3152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | BPC 9102S |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | RFC 4072S |
Affected:
0 , < 2025.0.2
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41668",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-08T14:23:22.573108Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T14:28:20.367Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Nozomi"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA low privileged remote attacker with file access can replace a critical file or folder used by the service security-profile to get read, write and execute access to any file on the device.\u003c/p\u003e"
}
],
"value": "A low privileged remote attacker with file access can replace a critical file or folder used by the service security-profile to get read, write and execute access to any file on the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-59",
"description": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T07:04:22.922Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/en/advisories/VDE-2025-054"
}
],
"source": {
"advisory": "VDE-2025-054",
"defect": [
"CERT@VDE#641795"
],
"discovery": "UNKNOWN"
},
"title": "Phoenix Contact: File access due to the replacement of a critical file used by the service security-profile",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41668",
"datePublished": "2025-07-08T07:04:22.922Z",
"dateReserved": "2025-04-16T11:17:48.307Z",
"dateUpdated": "2025-07-08T14:28:20.367Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41667 (GCVE-0-2025-41667)
Vulnerability from cvelistv5 – Published: 2025-07-08 07:03 – Updated: 2025-07-08 14:28- CWE-59 - Improper Link Resolution Before File Access ('Link Following')
| Vendor | Product | Version | |
|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | AXC F 2152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | AXC F 3152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | BPC 9102S |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | RFC 4072S |
Affected:
0 , < 2025.0.2
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41667",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-08T14:23:25.430004Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T14:28:29.391Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Nozomi"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A low privileged remote attacker with file access can replace a critical file used by the arp-preinit script to get read, write and execute access to any file on the device."
}
],
"value": "A low privileged remote attacker with file access can replace a critical file used by the arp-preinit script to get read, write and execute access to any file on the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-59",
"description": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T07:04:06.715Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/en/advisories/VDE-2025-054"
}
],
"source": {
"advisory": "VDE-2025-054",
"defect": [
"CERT@VDE#641795"
],
"discovery": "UNKNOWN"
},
"title": "Phoenix Contact: File access due to the replacement of a critical file used by the arp-preinit script",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41667",
"datePublished": "2025-07-08T07:03:50.761Z",
"dateReserved": "2025-04-16T11:17:48.307Z",
"dateUpdated": "2025-07-08T14:28:29.391Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41666 (GCVE-0-2025-41666)
Vulnerability from cvelistv5 – Published: 2025-07-08 07:03 – Updated: 2025-07-08 14:28- CWE-59 - Improper Link Resolution Before File Access ('Link Following')
| Vendor | Product | Version | |
|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | AXC F 2152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | AXC F 3152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | BPC 9102S |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | RFC 4072S |
Affected:
0 , < 2025.0.2
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41666",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-08T14:23:28.624235Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T14:28:36.584Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Nozomi"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A low privileged remote attacker with file access can replace a critical file used by the watchdog to get read, write and execute access to any file on the device after the watchdog has been initialized."
}
],
"value": "A low privileged remote attacker with file access can replace a critical file used by the watchdog to get read, write and execute access to any file on the device after the watchdog has been initialized."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-59",
"description": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T07:03:38.410Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/en/advisories/VDE-2025-054"
}
],
"source": {
"advisory": "VDE-2025-054",
"discovery": "UNKNOWN"
},
"title": "Phoenix Contact: File access due to the replacement of a critical file used by the watchdog",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41666",
"datePublished": "2025-07-08T07:03:38.410Z",
"dateReserved": "2025-04-16T11:17:48.307Z",
"dateUpdated": "2025-07-08T14:28:36.584Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41665 (GCVE-0-2025-41665)
Vulnerability from cvelistv5 – Published: 2025-07-08 07:03 – Updated: 2025-07-08 14:10- CWE-276 - Incorrect Default Permissions
| Vendor | Product | Version | |
|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | AXC F 2152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | AXC F 3152 |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | BPC 9102S |
Affected:
0 , < 2025.0.2
(semver)
|
|
| PHOENIX CONTACT | RFC 4072S |
Affected:
0 , < 2025.0.2
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41665",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-08T14:09:53.864838Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T14:10:19.960Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThan": "2025.0.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Nozomi"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn low privileged remote attacker can enforce the watchdog of the affected devices to reboot the PLC due to incorrect default permissions of a config file.\u003c/p\u003e"
}
],
"value": "An low privileged remote attacker can enforce the watchdog of the affected devices to reboot the PLC due to incorrect default permissions of a config file."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276 Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-08T07:03:26.147Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://certvde.com/en/advisories/VDE-2025-054"
}
],
"source": {
"advisory": "VDE-2025-054",
"defect": [
"CERT@VDE#641795"
],
"discovery": "UNKNOWN"
},
"title": "Phoenix Contact: DoS of the PLC due to incorrect default permissions possible",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2025-41665",
"datePublished": "2025-07-08T07:03:26.147Z",
"dateReserved": "2025-04-16T11:17:48.307Z",
"dateUpdated": "2025-07-08T14:10:19.960Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-46144 (GCVE-0-2023-46144)
Vulnerability from cvelistv5 – Published: 2023-12-14 14:08 – Updated: 2024-10-01 06:18- CWE-494 - Download of Code Without Integrity Check
| Vendor | Product | Version | |
|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | AXC F 2152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | AXC F 3152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | BPC 9102S |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | EPC 1502 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | EPC 1522 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | PLCnext Engineer |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | RFC 4072R |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | RFC 4072S |
Affected:
0 , ≤ 2024.0
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:37:39.934Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1502",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1522",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PLCnext Engineer",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072R",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reid Wightman of Dragos, Inc."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
}
],
"value": "A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494: Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-01T06:18:18.730Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"source": {
"advisory": "VDE-2023-058",
"defect": [
"CERT@VDE#64611"
],
"discovery": "EXTERNAL"
},
"title": "PHOENIX CONTACT: PLCnext Control prone to download of code without integrity check",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-46144",
"datePublished": "2023-12-14T14:08:07.244Z",
"dateReserved": "2023-10-17T07:04:03.577Z",
"dateUpdated": "2024-10-01T06:18:18.730Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-46142 (GCVE-0-2023-46142)
Vulnerability from cvelistv5 – Published: 2023-12-14 14:05 – Updated: 2024-08-02 20:37- CWE-732 - Incorrect Permission Assignment for Critical Resource
| Vendor | Product | Version | |
|---|---|---|---|
| PHOENIX CONTACT | AXC F 1152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | AXC F 2152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | AXC F 3152 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | BPC 9102S |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | EPC 1502 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | EPC 1522 |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | PLCnext Engineer |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | RFC 4072R |
Affected:
0 , ≤ 2024.0
(semver)
|
|
| PHOENIX CONTACT | RFC 4072S |
Affected:
0 , ≤ 2024.0
(semver)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:37:39.840Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AXC F 1152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 2152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AXC F 3152",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "BPC 9102S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1502",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EPC 1522",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PLCnext Engineer",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072R",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "RFC 4072S",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"lessThanOrEqual": "2024.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Reid Wightman of Dragos, Inc."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
}
],
"value": "A incorrect permission assignment for critical resource vulnerability in PLCnext products allows an remote attacker with low privileges to gain full access on the affected devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-14T14:05:35.741Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://https://cert.vde.com/en/advisories/VDE-2023-056/"
}
],
"source": {
"advisory": "VDE-2023-056",
"defect": [
"CERT@VDE#64609"
],
"discovery": "EXTERNAL"
},
"title": "PHOENIX CONTACT: Insufficient Read and Write Protection to Logic and Runtime Data in PLCnext Control",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-46142",
"datePublished": "2023-12-14T14:05:35.741Z",
"dateReserved": "2023-10-17T07:04:03.576Z",
"dateUpdated": "2024-08-02T20:37:39.840Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
VAR-201906-1031
Vulnerability from variot - Updated: 2024-11-23 21:52An issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices. Unlimited physical access to the PLC may lead to a manipulation of SD cards data. SD card manipulation may lead to an authentication bypass opportunity. Phoenix Contact AXC F 2152 and AXC F 2152 STARTERKIT The device contains an authentication vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Phoenix Contact PLCNext AXC F 2152 is a programmable logic controller from Phoenix Contact, Germany. An information-disclosure vulnerability. 2. An authentication-bypass vulnerability. 3. A denial-of-service vulnerability. Attackers can exploit these issues to bypass the authentication process, obtain sensitive information, perform unauthorized actions and crash the service, denying service to legitimate users
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201906-1031",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "axc f 2152",
"scope": "lt",
"trust": 1.0,
"vendor": "phoenixcontact",
"version": "2019.0_lts"
},
{
"model": "axc f 2152 starterkit",
"scope": "lt",
"trust": 1.0,
"vendor": "phoenixcontact",
"version": "2019.0_lts"
},
{
"model": "axc f 2152 starterkit",
"scope": "lt",
"trust": 0.8,
"vendor": "phoenix contact",
"version": "2019.0 lts"
},
{
"model": "axc f 2152",
"scope": "lt",
"trust": 0.8,
"vendor": "phoenix contact",
"version": "2019.0 lts"
},
{
"model": "contact plcnext axc f",
"scope": "eq",
"trust": 0.6,
"vendor": "phoenix",
"version": "21521.*"
},
{
"model": "contact axc f starterkit",
"scope": "eq",
"trust": 0.3,
"vendor": "phoenix",
"version": "21521.x"
},
{
"model": "contact axc f",
"scope": "eq",
"trust": 0.3,
"vendor": "phoenix",
"version": "21521.x"
},
{
"model": "contact axc f starterkit lts",
"scope": "ne",
"trust": 0.3,
"vendor": "phoenix",
"version": "21522019.0"
},
{
"model": "contact axc f lts",
"scope": "ne",
"trust": 0.3,
"vendor": "phoenix",
"version": "21522019.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-02972"
},
{
"db": "BID",
"id": "108688"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005605"
},
{
"db": "NVD",
"id": "CVE-2019-10998"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/o:phoenixcontact:axc_f_2152_starterkit_firmware",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/o:phoenixcontact:axc_f_2152_firmware",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-005605"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Zahra Khani of Firmalyzer and OPC Foundation.",
"sources": [
{
"db": "BID",
"id": "108688"
}
],
"trust": 0.3
},
"cve": "CVE-2019-10998",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "CVE-2019-10998",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "CNVD-2020-02972",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.9,
"id": "CVE-2019-10998",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.8,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2019-10998",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2019-10998",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2020-02972",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201906-092",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-02972"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005605"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-092"
},
{
"db": "NVD",
"id": "CVE-2019-10998"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices. Unlimited physical access to the PLC may lead to a manipulation of SD cards data. SD card manipulation may lead to an authentication bypass opportunity. Phoenix Contact AXC F 2152 and AXC F 2152 STARTERKIT The device contains an authentication vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Phoenix Contact PLCNext AXC F 2152 is a programmable logic controller from Phoenix Contact, Germany. An information-disclosure vulnerability. \n2. An authentication-bypass vulnerability. \n3. A denial-of-service vulnerability. \nAttackers can exploit these issues to bypass the authentication process, obtain sensitive information, perform unauthorized actions and crash the service, denying service to legitimate users",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-10998"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005605"
},
{
"db": "CNVD",
"id": "CNVD-2020-02972"
},
{
"db": "BID",
"id": "108688"
}
],
"trust": 2.43
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-10998",
"trust": 3.3
},
{
"db": "ICS CERT",
"id": "ICSA-19-155-01",
"trust": 2.3
},
{
"db": "BID",
"id": "108688",
"trust": 0.9
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005605",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2020-02972",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201906-092",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-02972"
},
{
"db": "BID",
"id": "108688"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005605"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-092"
},
{
"db": "NVD",
"id": "CVE-2019-10998"
}
]
},
"id": "VAR-201906-1031",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-02972"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS",
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-02972"
}
]
},
"last_update_date": "2024-11-23T21:52:09.122000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "VDE-2019-009",
"trust": 0.8,
"url": "https://dam-mdc.phoenixcontact.com/asset/156443151564/fa7be4d04c301f18c6cc0e0872193a42/Security_Advisory_AXC_F_2152_FW.pdf"
},
{
"title": "Patch for Phoenix Contact PLCNext AXC F 2152 Authorization Issue Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/198329"
},
{
"title": "Phoenix Contact PLCNext AXC F 2152 Fixes for access control error vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=93181"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-02972"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005605"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-092"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-287",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-005605"
},
{
"db": "NVD",
"id": "CVE-2019-10998"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.9,
"url": "https://dam-mdc.phoenixcontact.com/asset/156443151564/fa7be4d04c301f18c6cc0e0872193a42/security_advisory_axc_f_2152_fw.pdf"
},
{
"trust": 1.5,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-19-155-01"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-10998"
},
{
"trust": 0.9,
"url": "https://www.phoenixcontact.com/online/portal/pc/pxc/offcontext/insite_landing_page/!ut/p/z1/xzrrt4mwfiv_dy_kdtc19zhgsowfudkn0bdsogb1fobi0h8v00czwczevjrnzjn33jb9gemixiuzkksjki0o3tnijgbw2l0t8cxnlm-hlvus"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-10998"
},
{
"trust": 0.8,
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-155-01"
},
{
"trust": 0.6,
"url": "https://www.securityfocus.com/bid/108688"
},
{
"trust": 0.3,
"url": "https://www.phoenixcontact.com/online/portal/pc"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2020-02972"
},
{
"db": "BID",
"id": "108688"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005605"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-092"
},
{
"db": "NVD",
"id": "CVE-2019-10998"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2020-02972"
},
{
"db": "BID",
"id": "108688"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-005605"
},
{
"db": "CNNVD",
"id": "CNNVD-201906-092"
},
{
"db": "NVD",
"id": "CVE-2019-10998"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-01-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-02972"
},
{
"date": "2019-06-04T00:00:00",
"db": "BID",
"id": "108688"
},
{
"date": "2019-06-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-005605"
},
{
"date": "2019-06-04T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201906-092"
},
{
"date": "2019-06-18T13:15:10.707000",
"db": "NVD",
"id": "CVE-2019-10998"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-01-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2020-02972"
},
{
"date": "2019-06-04T00:00:00",
"db": "BID",
"id": "108688"
},
{
"date": "2019-07-09T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-005605"
},
{
"date": "2019-07-02T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201906-092"
},
{
"date": "2024-11-21T04:20:19.380000",
"db": "NVD",
"id": "CVE-2019-10998"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote or local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201906-092"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Phoenix Contact AXC F 2152 and AXC F 2152 STARTERKIT Authentication vulnerabilities in devices",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-005605"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "authorization issue",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201906-092"
}
],
"trust": 0.6
}
}