Search

Find a vulnerability

Search criteria

    6 vulnerabilities found for 6es7416-3fs07-0ab0_firmware by siemens

    FKIE_CVE-2022-47375

    Vulnerability from fkie_nvd - Published: 2023-12-12 12:15 - Updated: 2026-06-17 05:13
    Summary
    A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly. This could allow an attacker to create a buffer overflow and create a denial of service condition for the device.

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC\u00a0PC-Station Plus",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 412-2 PN V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS S120 (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V5.2 SP3 HF15"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "source": "productcert@siemens.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:6es7412-2ek07-0ab0_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B9F039A6-AD1F-489C-9928-147973AE8DF3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:6es7412-2ek07-0ab0:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "363D7EEE-9AC0-40D9-9C0A-2B098D152230",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:6es7414-3em07-0ab0_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "257AB2BE-EA5A-47D0-9677-D00FF682C170",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:6es7414-3em07-0ab0:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "438FDBD7-1731-4D1B-ABA6-76F376054F07",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:6es7414-3fm07-0ab0_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0622ACDF-D82B-487C-84DF-75853A88184C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:6es7414-3fm07-0ab0:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "23B55825-D285-459F-AB82-110EC58D583C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:6es7416-3es07-0ab0_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "268D8CA8-92BD-40BE-BCB0-8EBA4B724381",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:6es7416-3es07-0ab0:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "877F922F-D395-4123-B4C2-DCA7D699EB22",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:6es7416-3fs07-0ab0_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1031CEF8-0F66-452E-8E79-BC4A5EDDB10E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:6es7416-3fs07-0ab0:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DDA99580-AF0C-4837-B4DB-593C5A045129",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:6ag1414-3em07-7ab0_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "228593D4-10E2-4345-85F5-FE69E68722A3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:6ag1414-3em07-7ab0:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D2066A76-56E4-41C4-9057-F1697B9ADAFE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:6ag1416-3es07-7ab0_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BD7B48F6-B94E-4B65-A2A9-2B5BB333415B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:6ag1416-3es07-7ab0:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "41422165-ABEF-4F09-9E39-C4F89497894B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CDA8B933-D7E3-4E3B-AA1D-75AFC89EA730",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D61A6DA0-1328-4D6F-80A1-2A7CE369A7C9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.8:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B46F2FCA-845B-4E65-AF8C-B924E55921B3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.9:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0CD43CE2-ED05-4BBF-9553-04AB07D33F50",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DB8DD275-D4EA-426C-8611-C2083036A799",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.1:sp1:*:*:*:*:*:*",
                  "matchCriteriaId": "9EB60A1E-ABE0-4A1C-A2F0-C77E59DCF577",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.1:sp1_hotfix1:*:*:*:*:*:*",
                  "matchCriteriaId": "03224943-DCAF-4203-90BD-A6100745A3A8",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.1:sp1_hotfix13:*:*:*:*:*:*",
                  "matchCriteriaId": "59460788-9C30-444F-B0F5-B2ACB7B5CDCD",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:-:*:*:*:*:*:*",
                  "matchCriteriaId": "6622AE2E-81B0-419C-8C37-A7C56FB92745",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:hotfix1:*:*:*:*:*:*",
                  "matchCriteriaId": "D8DFFEC3-B48B-4B47-83E4-B73383003F68",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:hotfix11:*:*:*:*:*:*",
                  "matchCriteriaId": "10596147-76C0-4626-987B-AECA3D359C9F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:hotfix7:*:*:*:*:*:*",
                  "matchCriteriaId": "4B6DEC37-63E1-479C-91C5-A5339E5F4FAB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3:*:*:*:*:*:*",
                  "matchCriteriaId": "AD9434B6-29F3-445C-A3CA-57E2230622EA",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix1:*:*:*:*:*:*",
                  "matchCriteriaId": "284207F1-E83D-4D32-8D0C-5D20126D0B11",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix13:*:*:*:*:*:*",
                  "matchCriteriaId": "95DC883D-5792-4ECD-9A19-D97173FD2D96",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix6:*:*:*:*:*:*",
                  "matchCriteriaId": "7ADD4FD1-F3E2-480A-AE4E-747AA744F8D6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix9:*:*:*:*:*:*",
                  "matchCriteriaId": "E9DF3564-63E8-4B17-A2CD-799954C31B42",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_pc-station_plus_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0EA49005-5CEB-4AC5-8E3A-6400650C4F1A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_pc-station_plus:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D170B645-158D-443D-A565-FC44663DEA16",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC\u00a0PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions \u003c V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly.\r\n\r\nThis could allow an attacker to create a buffer overflow and create a denial of service condition for the device."
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en:\nSIMATIC PC-Station Plus (todas las versiones), \nSIMATIC S7-400 CPU 412-2 PN V7 (todas las versiones), \nSIMATIC S7-400 CPU 414-3 PN/DP V7 (todas las versiones), \nSIMATIC S7 -400 CPU 414F-3 PN/DP V7 (todas las versiones), \nSIMATIC S7-400 CPU 416-3 PN/DP V7 (todas las versiones), \nSIMATIC S7-400 CPU 416F-3 PN/DP V7 (todas las versiones), \nSINAMICS S120 (incl. variantes SIPLUS) (todas las versiones \u0026lt; V5.2 SP3 HF15), \nSIPLUS S7-400 CPU 414-3 PN/DP V7 (todas las versiones), \nSIPLUS S7-400 CPU 416-3 PN/DP V7 (todas las versiones) ). \nLos productos afectados no manejan correctamente los nombres de archivos largos. Esto podr\u00eda permitir a un atacante crear un desbordamiento del b\u00fafer y crear una condici\u00f3n de denegaci\u00f3n de servicio para el dispositivo."
        }
      ],
      "id": "CVE-2022-47375",
      "lastModified": "2026-06-17T05:13:26.770",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "productcert@siemens.com",
            "type": "Secondary"
          }
        ]
      },
      "published": "2023-12-12T12:15:10.797",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-805"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-119"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-47374

    Vulnerability from fkie_nvd - Published: 2023-12-12 12:15 - Updated: 2026-06-17 05:13
    Summary
    A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly. This could allow an attacker to exhaust system resources and create a denial of service condition for the device.

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC\u00a0PC-Station Plus",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 412-2 PN V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS S120 (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V5.2 SP3 HF15"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "source": "productcert@siemens.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:6es7412-2ek07-0ab0_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B9F039A6-AD1F-489C-9928-147973AE8DF3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:6es7412-2ek07-0ab0:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "363D7EEE-9AC0-40D9-9C0A-2B098D152230",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:6es7414-3em07-0ab0_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "257AB2BE-EA5A-47D0-9677-D00FF682C170",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:6es7414-3em07-0ab0:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "438FDBD7-1731-4D1B-ABA6-76F376054F07",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:6es7414-3fm07-0ab0_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0622ACDF-D82B-487C-84DF-75853A88184C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:6es7414-3fm07-0ab0:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "23B55825-D285-459F-AB82-110EC58D583C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:6es7416-3es07-0ab0_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "268D8CA8-92BD-40BE-BCB0-8EBA4B724381",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:6es7416-3es07-0ab0:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "877F922F-D395-4123-B4C2-DCA7D699EB22",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:6es7416-3fs07-0ab0_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1031CEF8-0F66-452E-8E79-BC4A5EDDB10E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:6es7416-3fs07-0ab0:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DDA99580-AF0C-4837-B4DB-593C5A045129",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:6ag1414-3em07-7ab0_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "228593D4-10E2-4345-85F5-FE69E68722A3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:6ag1414-3em07-7ab0:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D2066A76-56E4-41C4-9057-F1697B9ADAFE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:6ag1416-3es07-7ab0_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BD7B48F6-B94E-4B65-A2A9-2B5BB333415B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:6ag1416-3es07-7ab0:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "41422165-ABEF-4F09-9E39-C4F89497894B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CDA8B933-D7E3-4E3B-AA1D-75AFC89EA730",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D61A6DA0-1328-4D6F-80A1-2A7CE369A7C9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.8:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B46F2FCA-845B-4E65-AF8C-B924E55921B3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.9:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0CD43CE2-ED05-4BBF-9553-04AB07D33F50",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DB8DD275-D4EA-426C-8611-C2083036A799",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.1:sp1:*:*:*:*:*:*",
                  "matchCriteriaId": "9EB60A1E-ABE0-4A1C-A2F0-C77E59DCF577",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.1:sp1_hotfix1:*:*:*:*:*:*",
                  "matchCriteriaId": "03224943-DCAF-4203-90BD-A6100745A3A8",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.1:sp1_hotfix13:*:*:*:*:*:*",
                  "matchCriteriaId": "59460788-9C30-444F-B0F5-B2ACB7B5CDCD",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:-:*:*:*:*:*:*",
                  "matchCriteriaId": "6622AE2E-81B0-419C-8C37-A7C56FB92745",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:hotfix1:*:*:*:*:*:*",
                  "matchCriteriaId": "D8DFFEC3-B48B-4B47-83E4-B73383003F68",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:hotfix11:*:*:*:*:*:*",
                  "matchCriteriaId": "10596147-76C0-4626-987B-AECA3D359C9F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:hotfix7:*:*:*:*:*:*",
                  "matchCriteriaId": "4B6DEC37-63E1-479C-91C5-A5339E5F4FAB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3:*:*:*:*:*:*",
                  "matchCriteriaId": "AD9434B6-29F3-445C-A3CA-57E2230622EA",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix1:*:*:*:*:*:*",
                  "matchCriteriaId": "284207F1-E83D-4D32-8D0C-5D20126D0B11",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix13:*:*:*:*:*:*",
                  "matchCriteriaId": "95DC883D-5792-4ECD-9A19-D97173FD2D96",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix6:*:*:*:*:*:*",
                  "matchCriteriaId": "7ADD4FD1-F3E2-480A-AE4E-747AA744F8D6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:sp3_hotfix9:*:*:*:*:*:*",
                  "matchCriteriaId": "E9DF3564-63E8-4B17-A2CD-799954C31B42",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_pc-station_plus_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0EA49005-5CEB-4AC5-8E3A-6400650C4F1A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_pc-station_plus:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D170B645-158D-443D-A565-FC44663DEA16",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC\u00a0PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions \u003c V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly.\r\n\r\nThis could allow an attacker to exhaust system resources and create a denial of service condition for the device."
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en:\nSIMATIC PC-Station Plus (todas las versiones), \nSIMATIC S7-400 CPU 412-2 PN V7 (todas las versiones), \nSIMATIC S7-400 CPU 414-3 PN/DP V7 (todas las versiones), \nSIMATIC S7 -400 CPU 414F-3 PN/DP V7 (todas las versiones), \nSIMATIC S7-400 CPU 416-3 PN/DP V7 (todas las versiones), \nSIMATIC S7-400 CPU 416F-3 PN/DP V7 (todas las versiones), \nSINAMICS S120 (incl. variantes SIPLUS) (todas las versiones \u0026lt; V5.2 SP3 HF15), \nSIPLUS S7-400 CPU 414-3 PN/DP V7 (todas las versiones), \nSIPLUS S7-400 CPU 416-3 PN/DP V7 (todas las versiones) ). \nLos productos afectados no manejan correctamente las solicitudes HTTP(S) al servidor web. Esto podr\u00eda permitir que un atacante agote los recursos del sistema y cree una condici\u00f3n de denegaci\u00f3n de servicio para el dispositivo."
        }
      ],
      "id": "CVE-2022-47374",
      "lastModified": "2026-06-17T05:13:26.603",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "productcert@siemens.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2022-47374",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2023-12-23T05:01:16.237841Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-12-12T12:15:10.563",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-674"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Secondary"
        }
      ]
    }

    CVE-2022-47375 (GCVE-0-2022-47375)

    Vulnerability from nvd – Published: 2023-12-12 11:25 – Updated: 2024-08-03 14:55
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly. This could allow an attacker to create a buffer overflow and create a denial of service condition for the device.
    CWE
    • CWE-805 - Buffer Access with Incorrect Length Value
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 90 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:55:07.916Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC\u00a0PC-Station Plus",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 412-2 PN V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS S120 (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V5.2 SP3 HF15"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC\u00a0PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions \u003c V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly.\r\n\r\nThis could allow an attacker to create a buffer overflow and create a denial of service condition for the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-805",
                  "description": "CWE-805: Buffer Access with Incorrect Length Value",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-12T11:25:32.533Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2022-47375",
        "datePublished": "2023-12-12T11:25:32.533Z",
        "dateReserved": "2022-12-13T14:51:37.210Z",
        "dateUpdated": "2024-08-03T14:55:07.916Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-47374 (GCVE-0-2022-47374)

    Vulnerability from nvd – Published: 2023-12-12 11:25 – Updated: 2026-02-25 16:34
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly. This could allow an attacker to exhaust system resources and create a denial of service condition for the device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2023-12-23 05:01 UTC
    CWE
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 90 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:55:07.699Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-47374",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2023-12-23T05:01:16.237841Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-25T16:34:35.793Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC\u00a0PC-Station Plus",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 412-2 PN V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS S120 (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V5.2 SP3 HF15"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC\u00a0PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions \u003c V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly.\r\n\r\nThis could allow an attacker to exhaust system resources and create a denial of service condition for the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-674",
                  "description": "CWE-674: Uncontrolled Recursion",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-12T11:25:31.314Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2022-47374",
        "datePublished": "2023-12-12T11:25:31.314Z",
        "dateReserved": "2022-12-13T14:51:37.209Z",
        "dateUpdated": "2026-02-25T16:34:35.793Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-47375 (GCVE-0-2022-47375)

    Vulnerability from cvelistv5 – Published: 2023-12-12 11:25 – Updated: 2024-08-03 14:55
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly. This could allow an attacker to create a buffer overflow and create a denial of service condition for the device.
    CWE
    • CWE-805 - Buffer Access with Incorrect Length Value
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 90 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:55:07.916Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC\u00a0PC-Station Plus",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 412-2 PN V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS S120 (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V5.2 SP3 HF15"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC\u00a0PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions \u003c V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly.\r\n\r\nThis could allow an attacker to create a buffer overflow and create a denial of service condition for the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-805",
                  "description": "CWE-805: Buffer Access with Incorrect Length Value",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-12T11:25:32.533Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2022-47375",
        "datePublished": "2023-12-12T11:25:32.533Z",
        "dateReserved": "2022-12-13T14:51:37.210Z",
        "dateUpdated": "2024-08-03T14:55:07.916Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-47374 (GCVE-0-2022-47374)

    Vulnerability from cvelistv5 – Published: 2023-12-12 11:25 – Updated: 2026-02-25 16:34
    VLAI
    Summary
    A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly. This could allow an attacker to exhaust system resources and create a denial of service condition for the device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2023-12-23 05:01 UTC
    CWE
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 90 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:55:07.699Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-47374",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2023-12-23T05:01:16.237841Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-25T16:34:35.793Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC\u00a0PC-Station Plus",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 412-2 PN V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS S120 (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V5.2 SP3 HF15"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in SIMATIC\u00a0PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions \u003c V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle HTTP(S) requests to the web server correctly.\r\n\r\nThis could allow an attacker to exhaust system resources and create a denial of service condition for the device."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-674",
                  "description": "CWE-674: Uncontrolled Recursion",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-12-12T11:25:31.314Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-892915.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2022-47374",
        "datePublished": "2023-12-12T11:25:31.314Z",
        "dateReserved": "2022-12-13T14:51:37.209Z",
        "dateUpdated": "2026-02-25T16:34:35.793Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }