Search
Find a vulnerability
Search criteria
4 vulnerabilities
CVE-2026-15203 (GCVE-0-2026-15203)
Vulnerability from cvelistv5 – Published: 2026-08-26 05:36 – Updated: 2026-08-26 14:58
VLAI
EPSS
VEX
Title
Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 7Hybrid software
Summary
Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-26 14:55 UTC
CWE
- CWE-1191 - On-Chip debug and test interface with improper access control
Assigner
References
3 references
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Danfoss | iC7-Automation SP |
Affected:
0 , ≤ 2025.3.3
(custom)
|
|
| Danfoss | iC7-Marine |
Affected:
0 , ≤ 2025.8.19
(custom)
|
|
| Danfoss | iC7-Hybrid |
Affected:
0 , ≤ 2025.10.300845
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-15203",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-26T14:55:58.163499Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-08-26T14:58:01.137Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "iC7-Automation SP",
"vendor": "Danfoss",
"versions": [
{
"lessThanOrEqual": "2025.3.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "iC7-Marine",
"vendor": "Danfoss",
"versions": [
{
"lessThanOrEqual": "2025.8.19",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "iC7-Hybrid",
"vendor": "Danfoss",
"versions": [
{
"lessThanOrEqual": "2025.10.300845",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cdiv\u003eImproper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms\u003cbr\u003e\u003c/div\u003e\u003c/div\u003e"
}
],
"value": "Improper access control in debug and engineering interfaces in Danfoss iC7-Automation SP, iC7-Marine, and iC7-Hybrid GR3 allows attackers to gain read/write access to internal values, upload and execute unsigned applications, and upload unsigned EEPROM data and firmware via exposed service interfaces and software update mechanisms"
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1191",
"description": "CWE-1191 On-Chip debug and test interface with improper access control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-26T05:36:02.006Z",
"orgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"shortName": "Danfoss"
},
"references": [
{
"tags": [
"patch"
],
"url": "https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip"
},
{
"tags": [
"patch"
],
"url": "https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip"
},
{
"tags": [
"patch"
],
"url": "https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003e\u003cul\u003e\u003cli\u003eiC7-Automation SP:\u0026nbsp;\u003ca href=\"https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\" title=\"https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\"\u003ehttps://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.2.5-26A)\u003c/li\u003e\u003cli\u003eiC7-Marine:\u0026nbsp;\u003ca href=\"https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\" title=\"https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\"\u003ehttps://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.6.30-GR4.4)\u003c/li\u003e\u003cli\u003eiC7-Hybrid:\u0026nbsp;\u003ca href=\"https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\" title=\"https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\"\u003ehttps://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip\u003c/a\u003e\u0026nbsp;(Release\u0026nbsp;2026.7.2-GR4.5)\u003c/li\u003e\u003c/ul\u003e\u003c/div\u003e"
}
],
"value": "* iC7-Automation SP:\u00a0 https://assets.danfoss.com/software/latest/572932/ID543724747716-0201.zip \u00a0(Release\u00a02026.2.5-26A)\n * iC7-Marine:\u00a0 https://assets.danfoss.com/software/latest/595833/ID506542766960-0501.zip \u00a0(Release\u00a02026.6.30-GR4.4)\n * iC7-Hybrid:\u00a0 https://assets.danfoss.com/software/latest/595835/ID506543688961-0601.zip \u00a0(Release\u00a02026.7.2-GR4.5)"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Debug interfaces are accessible by default in Danfoss iC7 Automation SP, iC7 Marine and iC7 7Hybrid software",
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
}
},
"cveMetadata": {
"assignerOrgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"assignerShortName": "Danfoss",
"cveId": "CVE-2026-15203",
"datePublished": "2026-08-26T05:36:02.006Z",
"dateReserved": "2026-07-09T06:41:49.174Z",
"dateUpdated": "2026-08-26T14:58:01.137Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-41452 (GCVE-0-2025-41452)
Vulnerability from cvelistv5 – Published: 2025-08-22 02:40 – Updated: 2025-08-22 10:52
VLAI
EPSS
VEX
Title
Post auth nginx configuration injection in Danfoss AK-SM8xxA Series
Summary
Post-authenticated external control of system web interface configuration setting vulnerability in Danfoss AK-SM8xxA Series prior to 4.3.1, which could allow for a denial of service attack induced by improper handling of exceptional conditions
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-08-22 10:52 UTC
CWE
- CWE-15 - External Control of System or Configuration Setting
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Danfoss | AK-SM8xxA Series |
Affected:
0 , < 4.3.1
(cpe)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41452",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-22T10:52:01.090719Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T10:52:36.122Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AK-SM8xxA Series",
"vendor": "Danfoss",
"versions": [
{
"lessThan": "4.3.1",
"status": "affected",
"version": "0",
"versionType": "cpe"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Post-authenticated external control of system web interface configuration setting vulnerability in Danfoss AK-SM8xxA Series prior to 4.3.1, which\u0026nbsp;could allow for a denial of service attack induced by improper handling of exceptional conditions"
}
],
"value": "Post-authenticated external control of system web interface configuration setting vulnerability in Danfoss AK-SM8xxA Series prior to 4.3.1, which\u00a0could allow for a denial of service attack induced by improper handling of exceptional conditions"
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:A/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-15",
"description": "CWE-15: External Control of System or Configuration Setting",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T02:40:53.563Z",
"orgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"shortName": "Danfoss"
},
"references": [
{
"url": "https://www.danfoss.com/en/service-and-support/downloads/dcs/adap-kool-software/ak-sm-800a/#tab-overview"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Post auth nginx configuration injection in Danfoss AK-SM8xxA Series",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"assignerShortName": "Danfoss",
"cveId": "CVE-2025-41452",
"datePublished": "2025-08-22T02:40:53.563Z",
"dateReserved": "2025-04-16T10:32:42.818Z",
"dateUpdated": "2025-08-22T10:52:36.122Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41451 (GCVE-0-2025-41451)
Vulnerability from cvelistv5 – Published: 2025-08-22 02:40 – Updated: 2025-08-22 11:25
VLAI
EPSS
VEX
Title
Post-Authentication OS Command Injection RCE in Danfoss AK-SM8xxA Series
Summary
Improper neutralization of alarm-to-mail configuration fields used in an OS shell Command ('Command Injection') in Danfoss AK-SM8xxA Series prior to version 4.3.1, leading to a potential post-authenticated remote code execution on an attacked system.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-08-22 10:59 UTC
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Danfoss | AK-SM8xxA Series |
Affected:
0 , < 4.3.1
(cpe)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41451",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-22T10:59:49.161150Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T11:25:28.640Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AK-SM8xxA Series",
"vendor": "Danfoss",
"versions": [
{
"lessThan": "4.3.1",
"status": "affected",
"version": "0",
"versionType": "cpe"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper neutralization of alarm-to-mail configuration fields used in an OS shell Command (\u0027Command Injection\u0027) in Danfoss AK-SM8xxA Series\u0026nbsp;prior to version 4.3.1, leading to a potential post-authenticated remote code execution on an attacked system."
}
],
"value": "Improper neutralization of alarm-to-mail configuration fields used in an OS shell Command (\u0027Command Injection\u0027) in Danfoss AK-SM8xxA Series\u00a0prior to version 4.3.1, leading to a potential post-authenticated remote code execution on an attacked system."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T02:40:46.216Z",
"orgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"shortName": "Danfoss"
},
"references": [
{
"url": "https://www.danfoss.com/en/service-and-support/downloads/dcs/adap-kool-software/ak-sm-800a/#tab-overview"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Post-Authentication OS Command Injection RCE in Danfoss AK-SM8xxA Series",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"assignerShortName": "Danfoss",
"cveId": "CVE-2025-41451",
"datePublished": "2025-08-22T02:40:46.216Z",
"dateReserved": "2025-04-16T10:32:42.818Z",
"dateUpdated": "2025-08-22T11:25:28.640Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-41450 (GCVE-0-2025-41450)
Vulnerability from cvelistv5 – Published: 2025-05-08 09:41 – Updated: 2025-08-27 07:14
VLAI
EPSS
VEX
Title
Authentication bypass with privileged access in Danfoss AK-SM 8xxA Series prior to version 4.2
Summary
Improper Authentication vulnerability in Danfoss AKSM8xxA Series.This issue affects Danfoss AK-SM 8xxA Series prior to version 4.2
Severity
8.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-08 13:51 UTC
CWE
- CWE-305 - Authentication Bypass by Primary Weakness
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Danfoss | AK-SM 8xxA Series |
Affected:
0 , < 4.2
(custom)
|
Date Public
2025-05-08 09:40
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-41450",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-08T13:51:39.737731Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-08T13:52:31.326Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AK-SM 8xxA Series",
"vendor": "Danfoss",
"versions": [
{
"lessThan": "4.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2025-05-08T09:40:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Authentication vulnerability in Danfoss AKSM8xxA Series.\u003cp\u003eThis issue affects Danfoss AK-SM 8xxA Series prior to version 4.2\u003c/p\u003e"
}
],
"value": "Improper Authentication vulnerability in Danfoss AKSM8xxA Series.This issue affects Danfoss AK-SM 8xxA Series prior to version 4.2"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-305",
"description": "CWE-305: Authentication Bypass by Primary Weakness",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T07:14:14.846Z",
"orgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"shortName": "Danfoss"
},
"references": [
{
"url": "https://www.danfoss.com/en/service-and-support/coordinated-vulnerability-disclosure/danfoss-security-advisories/dsa-2025-03-01/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Authentication bypass with privileged access in Danfoss AK-SM 8xxA Series prior to version 4.2",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "d7ff35af-cf88-454c-bab9-af60602f10f8",
"assignerShortName": "Danfoss",
"cveId": "CVE-2025-41450",
"datePublished": "2025-05-08T09:41:20.881Z",
"dateReserved": "2025-04-16T10:32:42.818Z",
"dateUpdated": "2025-08-27T07:14:14.846Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}