CWE-319

Cleartext Transmission of Sensitive Information

The product transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.

CVE-2021-20335 (GCVE-0-2021-20335)

Vulnerability from cvelistv5 – Published: 2021-02-11 10:10 – Updated: 2024-09-17 01:50
VLAI
Title
SSL may be unexpectedly disabled during upgrade of multiple-server MongoDB Ops Manager
Summary
For MongoDB Ops Manager versions prior to and including 4.2.24 with multiple OM application servers, that have SSL turned on for their MongoDB processes, the upgrade to MongoDB Ops Manager versions prior to and including 4.4.12 triggers a bug where Automation thinks SSL is being turned off, and can disable SSL temporarily for members of the cluster. This issue is temporary and eventually corrects itself after MongoDB Ops Manager instances have finished upgrading to MongoDB Ops Manager 4.4. In addition, customers must be running with clientCertificateMode=OPTIONAL / allowConnectionsWithoutCertificates=true to be impacted*.* Customers upgrading from Ops Manager 4.2.X to 4.2.24 and finally to Ops Manager 4.4.13+ are unaffected by this issue.
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
MongoDB Inc. MongoDB Ops Manager Affected: 4.2 , ≤ 4.2.24 (custom)
Create a notification for this product.
Date Public
2021-02-11 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:37:23.802Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://docs.opsmanager.mongodb.com/v4.2/release-notes/application/#onprem-server-4-2-23"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MongoDB Ops Manager",
          "vendor": "MongoDB Inc.",
          "versions": [
            {
              "lessThanOrEqual": "4.2.24",
              "status": "affected",
              "version": "4.2",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-02-11T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\u003c/p\u003e\u003cp\u003eFor MongoDB Ops Manager versions prior to and including 4.2.24 with multiple OM application servers, that have SSL turned on for their MongoDB processes, the upgrade to MongoDB Ops Manager versions prior to and including 4.4.12 triggers a bug where Automation thinks SSL is being turned off, and can disable SSL temporarily for members of the cluster. This issue is temporary and eventually corrects itself after MongoDB Ops Manager instances have finished upgrading to MongoDB Ops Manager 4.4. In addition, customers must be running with clientCertificateMode=OPTIONAL / allowConnectionsWithoutCertificates=true to be impacted*.* Customers upgrading from Ops Manager 4.2.X to 4.2.24 and finally to Ops Manager 4.4.13+ are unaffected by this issue.\u003c/p\u003e\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "For MongoDB Ops Manager versions prior to and including 4.2.24 with multiple OM application servers, that have SSL turned on for their MongoDB processes, the upgrade to MongoDB Ops Manager versions prior to and including 4.4.12 triggers a bug where Automation thinks SSL is being turned off, and can disable SSL temporarily for members of the cluster. This issue is temporary and eventually corrects itself after MongoDB Ops Manager instances have finished upgrading to MongoDB Ops Manager 4.4. In addition, customers must be running with clientCertificateMode=OPTIONAL / allowConnectionsWithoutCertificates=true to be impacted*.* Customers upgrading from Ops Manager 4.2.X to 4.2.24 and finally to Ops Manager 4.4.13+ are unaffected by this issue."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-23T16:21:36.855Z",
        "orgId": "a39b4221-9bd0-4244-95fc-f3e2e07f1deb",
        "shortName": "mongodb"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://docs.opsmanager.mongodb.com/v4.2/release-notes/application/#onprem-server-4-2-23"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "SSL may be unexpectedly disabled during upgrade of multiple-server MongoDB Ops Manager",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cna@mongodb.com",
          "DATE_PUBLIC": "2021-02-11T10:00:00.000Z",
          "ID": "CVE-2021-20335",
          "STATE": "PUBLIC",
          "TITLE": "SSL may be unexpectedly disabled during upgrade of multiple-server MongoDB Ops Manager"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Ops Manager",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "4.2",
                            "version_value": "4.2.24"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "MongoDB Inc."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "For MongoDB Ops Manager \u003c= 4.2.24 with multiple OM application servers, that have SSL turned on for their MongoDB processes, the upgrade to MongoDB Ops Manager \u003c= 4.4.12 triggers a bug where Automation thinks SSL is being turned off, and can disable SSL temporarily for members of the cluster. This issue is temporary and eventually corrects itself after MongoDB Ops Manager instances have finished upgrading to MongoDB Ops Manager 4.4. In addition, customers must be running with clientCertificateMode=OPTIONAL / allowConnectionsWithoutCertificates=true to be impacted*.* Customers upgrading from Ops Manager 4.2.X to 4.2.24 and finally to Ops Manager 4.4.13+ are unaffected by this issue."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-319 Cleartext Transmission of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://docs.opsmanager.mongodb.com/v4.2/release-notes/application/#onprem-server-4-2-23",
              "refsource": "CONFIRM",
              "url": "https://docs.opsmanager.mongodb.com/v4.2/release-notes/application/#onprem-server-4-2-23"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a39b4221-9bd0-4244-95fc-f3e2e07f1deb",
    "assignerShortName": "mongodb",
    "cveId": "CVE-2021-20335",
    "datePublished": "2021-02-11T10:10:13.856Z",
    "dateReserved": "2020-12-17T00:00:00.000Z",
    "dateUpdated": "2024-09-17T01:50:44.645Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-20599 (GCVE-0-2021-20599)

Vulnerability from cvelistv5 – Published: 2021-10-14 00:00 – Updated: 2024-08-03 17:45
VLAI
Summary
Cleartext Transmission of Sensitive InformationCleartext transmission of sensitive information vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU firmware versions "26" and prior and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than password.
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:mitsubishielectric:melsec_iq-r08sfcpu:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "melsec_iq-r08sfcpu",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "status": "affected",
                "version": "-"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:mitsubishielectric:r16sfcpu:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "r16sfcpu",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "status": "affected",
                "version": "-"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:mitsubishielectric:r32sfcpu:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "r32sfcpu",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "status": "affected",
                "version": "-"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:mitsubishielectric:r120sfcpu:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "r120sfcpu",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "status": "affected",
                "version": "-"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:mitsubishielectric:r08psfcpu:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "r08psfcpu",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "status": "affected",
                "version": "-"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:mitsubishielectric:r16psfcpu:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "r16psfcpu",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "status": "affected",
                "version": "-"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:mitsubishielectric:r32psfcpu:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "r32psfcpu",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "status": "affected",
                "version": "-"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:mitsubishielectric:r120psfcpu:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "r120psfcpu",
            "vendor": "mitsubishielectric",
            "versions": [
              {
                "status": "affected",
                "version": "-"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-20599",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-22T20:51:10.357119Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:12:41.515Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:45:44.681Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-011_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU98578731"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-287-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series Safety CPU R08SFCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware versions \"26\" and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R series Safety CPU R16SFCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware versions \"26\" and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R series Safety CPU R32SFCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware versions \"26\" and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R series Safety CPU R120SFCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware versions \"26\" and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R Series SIL2 Process CPU R08PSFCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware versions \"11\" and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R series SIL2 Process CPU R16PSFCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware versions \"11\" and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R series SIL2 Process CPU R32PSFCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware versions \"11\" and prior"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-R series SIL2 Process CPU R120PSFCPU",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware versions \"11\" and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Cleartext Transmission of Sensitive InformationCleartext transmission of sensitive information vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU firmware versions \"26\" and prior and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU firmware versions \"11\" and prior allows a remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than password."
            }
          ],
          "value": "Cleartext Transmission of Sensitive InformationCleartext transmission of sensitive information vulnerability in MELSEC iQ-R series Safety CPU R08/16/32/120SFCPU firmware versions \"26\" and prior and MELSEC iQ-R series SIL2 Process CPU R08/16/32/120PSFCPU firmware versions \"11\" and prior allows a remote unauthenticated attacker to login to a target CPU module by obtaining credentials other than password."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-18T05:28:04.068Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-011_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU98578731"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-287-03"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2021-20599",
    "datePublished": "2021-10-14T00:00:00.000Z",
    "dateReserved": "2020-12-17T00:00:00.000Z",
    "dateUpdated": "2024-08-03T17:45:44.681Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-20992 (GCVE-0-2021-20992)

Vulnerability from cvelistv5 – Published: 2021-04-19 14:05 – Updated: 2024-09-17 02:36
VLAI
Title
Fibaro Home Center Unencrypted management interface
Summary
In Fibaro Home Center 2 and Lite devices in all versions provide a web based management interface over unencrypted HTTP protocol. Communication between the user and the device can be eavesdropped to hijack sessions, tokens and passwords.
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
Fibar Group S.A Fibaro Home Center Affected: Home Center 2 all
Affected: Home Center Lite all
Create a notification for this product.
Date Public
2021-04-15 00:00
Credits
Marton Illes IoT Inspector Research Lab https://www.iot-inspector.com
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:53:23.114Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/"
          },
          {
            "name": "20210419 [CVE-2021-20989, CVE-2021-20990, CVE-2021-20991, CVE-2021-20992] Multiple vulnerabilities in Fibaro Home Center",
            "tags": [
              "mailing-list",
              "x_refsource_FULLDISC",
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2021/Apr/27"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Fibaro Home Center",
          "vendor": "Fibar Group S.A",
          "versions": [
            {
              "status": "affected",
              "version": "Home Center 2 all"
            },
            {
              "status": "affected",
              "version": "Home Center Lite all"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Marton Illes IoT Inspector Research Lab https://www.iot-inspector.com"
        }
      ],
      "datePublic": "2021-04-15T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "In Fibaro Home Center 2 and Lite devices in all versions provide a web based management interface over unencrypted HTTP protocol. Communication between the user and the device can be eavesdropped to hijack sessions, tokens and passwords."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-20T17:06:19.000Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/"
        },
        {
          "name": "20210419 [CVE-2021-20989, CVE-2021-20990, CVE-2021-20991, CVE-2021-20992] Multiple vulnerabilities in Fibaro Home Center",
          "tags": [
            "mailing-list",
            "x_refsource_FULLDISC"
          ],
          "url": "http://seclists.org/fulldisclosure/2021/Apr/27"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Fibaro Home Center Unencrypted management interface",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2021-04-15T10:00:00.000Z",
          "ID": "CVE-2021-20992",
          "STATE": "PUBLIC",
          "TITLE": "Fibaro Home Center Unencrypted management interface"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Fibaro Home Center",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "Home Center 2",
                            "version_value": "all"
                          },
                          {
                            "version_affected": "=",
                            "version_name": "Home Center Lite",
                            "version_value": "all"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Fibar Group S.A"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Marton Illes IoT Inspector Research Lab https://www.iot-inspector.com"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Fibaro Home Center 2 and Lite devices in all versions provide a web based management interface over unencrypted HTTP protocol. Communication between the user and the device can be eavesdropped to hijack sessions, tokens and passwords."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-319 Cleartext Transmission of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/",
              "refsource": "CONFIRM",
              "url": "https://www.iot-inspector.com/blog/advisory-fibaro-home-center/"
            },
            {
              "name": "20210419 [CVE-2021-20989, CVE-2021-20990, CVE-2021-20991, CVE-2021-20992] Multiple vulnerabilities in Fibaro Home Center",
              "refsource": "FULLDISC",
              "url": "http://seclists.org/fulldisclosure/2021/Apr/27"
            },
            {
              "name": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html",
              "refsource": "MISC",
              "url": "http://packetstormsecurity.com/files/162243/Fibaro-Home-Center-MITM-Missing-Authentication-Code-Execution.html"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2021-20992",
    "datePublished": "2021-04-19T14:05:02.730Z",
    "dateReserved": "2020-12-17T00:00:00.000Z",
    "dateUpdated": "2024-09-17T02:36:30.816Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21270 (GCVE-0-2021-21270)

Vulnerability from cvelistv5 – Published: 2021-01-22 18:05 – Updated: 2024-08-03 18:09
VLAI
Title
Cleartext Storage of Sensitive Information
Summary
OctopusDSC is a PowerShell module with DSC resources that can be used to install and configure an Octopus Deploy Server and Tentacle agent. In OctopusDSC version 4.0.977 and earlier a customer API key used to connect to Octopus Server is exposed via logging in plaintext. This vulnerability is patched in version 4.0.1002.
CWE
  • CWE-319 - {"CWE-319":"Cleartext Transmission of Sensitive Information"}
Assigner
Impacted products
Vendor Product Version
OctopusDeploy OctopusDSC Affected: < 4.0.1002
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:09:14.987Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/OctopusDeploy/OctopusDSC/security/advisories/GHSA-phmm-rfg9-94fm"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/OctopusDeploy/OctopusDSC/releases/tag/v4.0.1002"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/OctopusDeploy/OctopusDSC/pull/270"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/OctopusDeploy/OctopusDSC/commit/24b448e6ac964ed938475add494a145c0473ac42"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "OctopusDSC",
          "vendor": "OctopusDeploy",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 4.0.1002"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "OctopusDSC is a PowerShell module with DSC resources that can be used to install and configure an Octopus Deploy Server and Tentacle agent. In OctopusDSC version 4.0.977 and earlier a customer API key used to connect to Octopus Server is exposed via logging in plaintext. This vulnerability is patched in version 4.0.1002."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "{\"CWE-319\":\"Cleartext Transmission of Sensitive Information\"}",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-22T18:05:24.000Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/OctopusDeploy/OctopusDSC/security/advisories/GHSA-phmm-rfg9-94fm"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/OctopusDeploy/OctopusDSC/releases/tag/v4.0.1002"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/OctopusDeploy/OctopusDSC/pull/270"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/OctopusDeploy/OctopusDSC/commit/24b448e6ac964ed938475add494a145c0473ac42"
        }
      ],
      "source": {
        "advisory": "GHSA-phmm-rfg9-94fm",
        "discovery": "UNKNOWN"
      },
      "title": "Cleartext Storage of Sensitive Information",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-advisories@github.com",
          "ID": "CVE-2021-21270",
          "STATE": "PUBLIC",
          "TITLE": "Cleartext Storage of Sensitive Information"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "OctopusDSC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c 4.0.1002"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "OctopusDeploy"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "OctopusDSC is a PowerShell module with DSC resources that can be used to install and configure an Octopus Deploy Server and Tentacle agent. In OctopusDSC version 4.0.977 and earlier a customer API key used to connect to Octopus Server is exposed via logging in plaintext. This vulnerability is patched in version 4.0.1002."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.2,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "{\"CWE-319\":\"Cleartext Transmission of Sensitive Information\"}"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/OctopusDeploy/OctopusDSC/security/advisories/GHSA-phmm-rfg9-94fm",
              "refsource": "CONFIRM",
              "url": "https://github.com/OctopusDeploy/OctopusDSC/security/advisories/GHSA-phmm-rfg9-94fm"
            },
            {
              "name": "https://github.com/OctopusDeploy/OctopusDSC/releases/tag/v4.0.1002",
              "refsource": "MISC",
              "url": "https://github.com/OctopusDeploy/OctopusDSC/releases/tag/v4.0.1002"
            },
            {
              "name": "https://github.com/OctopusDeploy/OctopusDSC/pull/270",
              "refsource": "MISC",
              "url": "https://github.com/OctopusDeploy/OctopusDSC/pull/270"
            },
            {
              "name": "https://github.com/OctopusDeploy/OctopusDSC/commit/24b448e6ac964ed938475add494a145c0473ac42",
              "refsource": "MISC",
              "url": "https://github.com/OctopusDeploy/OctopusDSC/commit/24b448e6ac964ed938475add494a145c0473ac42"
            }
          ]
        },
        "source": {
          "advisory": "GHSA-phmm-rfg9-94fm",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2021-21270",
    "datePublished": "2021-01-22T18:05:24.000Z",
    "dateReserved": "2020-12-22T00:00:00.000Z",
    "dateUpdated": "2024-08-03T18:09:14.987Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21387 (GCVE-0-2021-21387)

Vulnerability from cvelistv5 – Published: 2021-03-19 15:25 – Updated: 2024-08-03 18:09
VLAI
Title
Partial secret key disclosure, improper safety number calculation, & inadequate encryption strength
Summary
Wrongthink peer-to-peer, end-to-end encrypted messenger with PeerJS and Axolotl ratchet. In wrongthink from version 2.0.0 and before 2.3.0 there was a set of vulnerabilities causing inadequate encryption strength. Part of the secret identity key was disclosed by the fingerprint used for connection. Additionally, the safety number was improperly calculated. It was computed using part of one of the public identity keys instead of being derived from both public identity keys. This caused issues in computing safety numbers which would potentially be exploitable in the real world. Additionally there was inadequate encryption strength due to use of 1024-bit DSA keys. These issues are all fixed in version 2.3.0.
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
  • CWE-326 - Inadequate Encryption Strength
  • CWE-358 - Improperly Implemented Security Check for Standard
Assigner
References
Impacted products
Vendor Product Version
parabirb wrongthink Affected: >= 2.0.0, < 2.2.0
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:09:15.979Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/parabirb/wrongthink/security/advisories/GHSA-5jxh-6378-rg7v"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "wrongthink",
          "vendor": "parabirb",
          "versions": [
            {
              "status": "affected",
              "version": "\u003e= 2.0.0, \u003c 2.2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Wrongthink peer-to-peer, end-to-end encrypted messenger with PeerJS and Axolotl ratchet. In wrongthink from version 2.0.0 and before 2.3.0 there was a set of vulnerabilities causing inadequate encryption strength. Part of the secret identity key was disclosed by the fingerprint used for connection. Additionally, the safety number was improperly calculated. It was computed using part of one of the public identity keys instead of being derived from both public identity keys. This caused issues in computing safety numbers which would potentially be exploitable in the real world. Additionally there was inadequate encryption strength due to use of 1024-bit DSA keys. These issues are all fixed in version 2.3.0."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319: Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326: Inadequate Encryption Strength",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-358",
              "description": "CWE-358: Improperly Implemented Security Check for Standard",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-03-19T15:25:12.000Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/parabirb/wrongthink/security/advisories/GHSA-5jxh-6378-rg7v"
        }
      ],
      "source": {
        "advisory": "GHSA-5jxh-6378-rg7v",
        "discovery": "UNKNOWN"
      },
      "title": "Partial secret key disclosure, improper safety number calculation, \u0026 inadequate encryption strength",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-advisories@github.com",
          "ID": "CVE-2021-21387",
          "STATE": "PUBLIC",
          "TITLE": "Partial secret key disclosure, improper safety number calculation, \u0026 inadequate encryption strength"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "wrongthink",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003e= 2.0.0, \u003c 2.2.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "parabirb"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Wrongthink peer-to-peer, end-to-end encrypted messenger with PeerJS and Axolotl ratchet. In wrongthink from version 2.0.0 and before 2.3.0 there was a set of vulnerabilities causing inadequate encryption strength. Part of the secret identity key was disclosed by the fingerprint used for connection. Additionally, the safety number was improperly calculated. It was computed using part of one of the public identity keys instead of being derived from both public identity keys. This caused issues in computing safety numbers which would potentially be exploitable in the real world. Additionally there was inadequate encryption strength due to use of 1024-bit DSA keys. These issues are all fixed in version 2.3.0."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-319: Cleartext Transmission of Sensitive Information"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-326: Inadequate Encryption Strength"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-358: Improperly Implemented Security Check for Standard"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/parabirb/wrongthink/security/advisories/GHSA-5jxh-6378-rg7v",
              "refsource": "CONFIRM",
              "url": "https://github.com/parabirb/wrongthink/security/advisories/GHSA-5jxh-6378-rg7v"
            }
          ]
        },
        "source": {
          "advisory": "GHSA-5jxh-6378-rg7v",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2021-21387",
    "datePublished": "2021-03-19T15:25:12.000Z",
    "dateReserved": "2020-12-22T00:00:00.000Z",
    "dateUpdated": "2024-08-03T18:09:15.979Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-22702 (GCVE-0-2021-22702)

Vulnerability from cvelistv5 – Published: 2021-02-19 15:13 – Updated: 2024-08-03 18:51
VLAI
Summary
A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts Telnet network traffic between a user and the device.
Severity
No CVSS data available.
CWE
  • CWE-319 - Cleartext transmission of sensitive information
Assigner
References
Impacted products
Vendor Product Version
n/a PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions) Affected: EcoStruxure Power Build - Rapsody software V2.1.13 and prior.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:51:07.456Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "EcoStruxure Power Build - Rapsody software V2.1.13 and prior."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts Telnet network traffic between a user and the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319: Cleartext transmission of sensitive information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-02-19T15:13:31.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2021-22702",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "EcoStruxure Power Build - Rapsody software V2.1.13 and prior."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts Telnet network traffic between a user and the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-319: Cleartext transmission of sensitive information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/",
              "refsource": "MISC",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2021-22702",
    "datePublished": "2021-02-19T15:13:31.000Z",
    "dateReserved": "2021-01-06T00:00:00.000Z",
    "dateUpdated": "2024-08-03T18:51:07.456Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-22703 (GCVE-0-2021-22703)

Vulnerability from cvelistv5 – Published: 2021-02-19 15:14 – Updated: 2024-08-03 18:51
VLAI
Summary
A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device.
Severity
No CVSS data available.
CWE
  • CWE-319 - Cleartext transmission of sensitive information
Assigner
References
Impacted products
Vendor Product Version
n/a PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions) Affected: EcoStruxure Power Build - Rapsody software V2.1.13 and prior.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:51:07.062Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "EcoStruxure Power Build - Rapsody software V2.1.13 and prior."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319: Cleartext transmission of sensitive information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-02-19T15:14:25.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2021-22703",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "EcoStruxure Power Build - Rapsody software V2.1.13 and prior."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-319: Cleartext transmission of sensitive information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/",
              "refsource": "MISC",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2021-040-01/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2021-22703",
    "datePublished": "2021-02-19T15:14:25.000Z",
    "dateReserved": "2021-01-06T00:00:00.000Z",
    "dateUpdated": "2024-08-03T18:51:07.062Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-22923 (GCVE-0-2021-22923)

Vulnerability from cvelistv5 – Published: 2021-08-05 00:00 – Updated: 2024-11-19 14:25
VLAI
Summary
When curl is instructed to get content using the metalink feature, and a user name and password are used to download the metalink XML file, those same credentials are then subsequently passed on to each of the servers from which curl will download or try to download the contents from. Often contrary to the user's expectations and intentions and without telling the user it happened.
Severity
No CVSS data available.
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information (CWE-319)
Assigner
Impacted products
Vendor Product Version
n/a https://github.com/curl/curl Affected: curl 7.27.0 to and including 7.77.0
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:58:26.153Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://hackerone.com/reports/1213181"
          },
          {
            "name": "FEDORA-2021-5d21b90a30",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/FRUCW2UVNYUDZF72DQLFQR4PJEC6CF7V/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20210902-0003/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
          },
          {
            "name": "GLSA-202212-01",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://security.gentoo.org/glsa/202212-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-22923",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-19T14:25:07.338932Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-19T14:25:24.567Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "https://github.com/curl/curl",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "curl 7.27.0 to and including 7.77.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "When curl is instructed to get content using the metalink feature, and a user name and password are used to download the metalink XML file, those same credentials are then subsequently passed on to each of the servers from which curl will download or try to download the contents from. Often contrary to the user\u0027s expectations and intentions and without telling the user it happened."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "Cleartext Transmission of Sensitive Information (CWE-319)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-19T00:00:00.000Z",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "url": "https://hackerone.com/reports/1213181"
        },
        {
          "name": "FEDORA-2021-5d21b90a30",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/FRUCW2UVNYUDZF72DQLFQR4PJEC6CF7V/"
        },
        {
          "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20210902-0003/"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
        },
        {
          "name": "GLSA-202212-01",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202212-01"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2021-22923",
    "datePublished": "2021-08-05T00:00:00.000Z",
    "dateReserved": "2021-01-06T00:00:00.000Z",
    "dateUpdated": "2024-11-19T14:25:24.567Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-23018 (GCVE-0-2021-23018)

Vulnerability from cvelistv5 – Published: 2021-06-01 11:51 – Updated: 2024-08-03 18:58
VLAI
Summary
Intra-cluster communication does not use TLS. The services within the NGINX Controller 3.x before 3.4.0 namespace are using cleartext protocols inside the cluster.
Severity
No CVSS data available.
CWE
Assigner
f5
References
Impacted products
Vendor Product Version
n/a Nginx Controller Affected: "3.x before 3.4.0"
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:58:26.256Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.f5.com/csp/article/K97002210"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Nginx Controller",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "\"3.x before 3.4.0\""
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Intra-cluster communication does not use TLS. The services within the NGINX Controller 3.x before 3.4.0 namespace are using cleartext protocols inside the cluster."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-01T11:51:20.000Z",
        "orgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
        "shortName": "f5"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.f5.com/csp/article/K97002210"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "f5sirt@f5.com",
          "ID": "CVE-2021-23018",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Nginx Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\"3.x before 3.4.0\""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Intra-cluster communication does not use TLS. The services within the NGINX Controller 3.x before 3.4.0 namespace are using cleartext protocols inside the cluster."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-319"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.f5.com/csp/article/K97002210",
              "refsource": "MISC",
              "url": "https://support.f5.com/csp/article/K97002210"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
    "assignerShortName": "f5",
    "cveId": "CVE-2021-23018",
    "datePublished": "2021-06-01T11:51:20.000Z",
    "dateReserved": "2021-01-06T00:00:00.000Z",
    "dateUpdated": "2024-08-03T18:58:26.256Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-23846 (GCVE-0-2021-23846)

Vulnerability from cvelistv5 – Published: 2021-06-18 13:38 – Updated: 2024-09-16 16:38
VLAI
Title
B426 Credential Disclosure
Summary
When using http protocol, the user password is transmitted as a clear text parameter for which it is possible to be obtained by an attacker through a MITM attack. This will be fixed starting from Firmware version 3.11.5, which will be released on the 30th of June, 2021.
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
Bosch B426 Firmware Affected: 03.01.0004
Affected: 03.02.002
Affected: 03.05.0003
Affected: 03.03.0009
Create a notification for this product.
Date Public
2021-05-28 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T19:14:09.219Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/security-advisories/bosch-sa-196933-bt.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "B426\u00a0Firmware",
          "vendor": "Bosch",
          "versions": [
            {
              "status": "affected",
              "version": "03.01.0004"
            },
            {
              "status": "affected",
              "version": "03.02.002"
            },
            {
              "status": "affected",
              "version": "03.05.0003"
            },
            {
              "status": "affected",
              "version": "03.03.0009"
            }
          ]
        }
      ],
      "datePublic": "2021-05-28T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "When using http protocol, the user password is transmitted as a clear text parameter for which it is possible to be obtained by an attacker through a MITM attack. This will be fixed starting from Firmware version 3.11.5, which will be released on the 30th of June, 2021."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-18T13:38:38.000Z",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/security-advisories/bosch-sa-196933-bt.html"
        }
      ],
      "source": {
        "advisory": "BOSCH-SA-196933-BT",
        "discovery": "UNKNOWN"
      },
      "title": "B426 Credential Disclosure",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2021-05-28",
          "ID": "CVE-2021-23846",
          "STATE": "PUBLIC",
          "TITLE": "B426 Credential Disclosure"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "B426\u00a0Firmware",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "03.01.0004"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "03.02.002"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "03.05.0003"
                          },
                          {
                            "version_affected": "=",
                            "version_value": "03.03.0009"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "When using http protocol, the user password is transmitted as a clear text parameter for which it is possible to be obtained by an attacker through a MITM attack. This will be fixed starting from Firmware version 3.11.5, which will be released on the 30th of June, 2021."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-319 Cleartext Transmission of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/security-advisories/bosch-sa-196933-bt.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/security-advisories/bosch-sa-196933-bt.html"
            }
          ]
        },
        "source": {
          "advisory": "BOSCH-SA-196933-BT",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2021-23846",
    "datePublished": "2021-06-18T13:38:38.275Z",
    "dateReserved": "2021-01-12T00:00:00.000Z",
    "dateUpdated": "2024-09-16T16:38:12.268Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation

Phase: Architecture and Design

Description:

  • Before transmitting, encrypt the data using reliable, confidentiality-protecting cryptographic protocols.
Mitigation

Phase: Implementation

Description:

  • When using web applications with SSL, use SSL for the entire session from login to logout, not just for the initial login page.
Mitigation

Phase: Implementation

Description:

  • When designing hardware platforms, ensure that approved encryption algorithms (such as those recommended by NIST) protect paths from security critical data to trusted user applications.
Mitigation

Phase: Testing

Description:

  • Use tools and techniques that require manual (human) analysis, such as penetration testing, threat modeling, and interactive tools that allow the tester to record and modify an active session. These may be more effective than strictly automated techniques. This is especially the case with weaknesses that are related to design and business rules.
Mitigation

Phase: Operation

Description:

  • Configure servers to use encrypted channels for communication, which may include SSL or other secure protocols.
CAPEC-102: Session Sidejacking

Session sidejacking takes advantage of an unencrypted communication channel between a victim and target system. The attacker sniffs traffic on a network looking for session tokens in unencrypted traffic. Once a session token is captured, the attacker performs malicious actions by using the stolen token with the targeted application to impersonate the victim. This attack is a specific method of session hijacking, which is exploiting a valid session token to gain unauthorized access to a target system or information. Other methods to perform a session hijacking are session fixation, cross-site scripting, or compromising a user or server machine and stealing the session token.

CAPEC-117: Interception

An adversary monitors data streams to or from the target for information gathering purposes. This attack may be undertaken to solely gather sensitive information or to support a further attack against the target. This attack pattern can involve sniffing network traffic as well as other types of data streams (e.g. radio). The adversary can attempt to initiate the establishment of a data stream or passively observe the communications as they unfold. In all variants of this attack, the adversary is not the intended recipient of the data stream. In contrast to other means of gathering information (e.g., targeting data leaks), the adversary must actively position themself so as to observe explicit data channels (e.g. network traffic) and read the content. However, this attack differs from a Adversary-In-the-Middle (CAPEC-94) attack, as the adversary does not alter the content of the communications nor forward data to the intended recipient.

CAPEC-383: Harvesting Information via API Event Monitoring

An adversary hosts an event within an application framework and then monitors the data exchanged during the course of the event for the purpose of harvesting any important data leaked during the transactions. One example could be harvesting lists of usernames or userIDs for the purpose of sending spam messages to those users. One example of this type of attack involves the adversary creating an event within the sub-application. Assume the adversary hosts a "virtual sale" of rare items. As other users enter the event, the attacker records via AiTM (CAPEC-94) proxy the user_ids and usernames of everyone who attends. The adversary would then be able to spam those users within the application using an automated script.

CAPEC-477: Signature Spoofing by Mixing Signed and Unsigned Content

An attacker exploits the underlying complexity of a data structure that allows for both signed and unsigned content, to cause unsigned data to be processed as though it were signed data.

CAPEC-65: Sniff Application Code

An adversary passively sniffs network communications and captures application code bound for an authorized client. Once obtained, they can use it as-is, or through reverse-engineering glean sensitive information or exploit the trust relationship between the client and server. Such code may belong to a dynamic update to the client, a patch being applied to a client component or any such interaction where the client is authorized to communicate with the server.

Back to CWE stats page