CWE-319
Cleartext Transmission of Sensitive Information
The product transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.
CVE-2018-19944 (GCVE-0-2018-19944)
Vulnerability from cvelistv5 – Published: 2020-12-31 16:33 – Updated: 2024-09-17 02:11| URL | Tags |
|---|---|
| https://www.qnap.com/zh-tw/security-advisory/qsa-20-22 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| QNAP Systems Inc. | QTS |
Affected:
unspecified , < 4.4.3.1354
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T11:51:17.673Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-22"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"platforms": [
"build 20200702"
],
"product": "QTS",
"vendor": "QNAP Systems Inc.",
"versions": [
{
"lessThan": "4.4.3.1354",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Independent Security Evaluators"
}
],
"datePublic": "2020-12-30T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A cleartext transmission of sensitive information vulnerability has been reported to affect certain QTS devices. If exploited, this vulnerability allows a remote attacker to gain access to sensitive information. QNAP have already fixed this vulnerability in the following versions: QTS 4.4.3.1354 build 20200702 (and later)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-311",
"description": "CWE-311 Missing Encryption of Sensitive Data",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-31T16:33:27.000Z",
"orgId": "2fd009eb-170a-4625-932b-17a53af1051f",
"shortName": "qnap"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-22"
}
],
"solutions": [
{
"lang": "en",
"value": "QNAP have already fixed this vulnerability in the following versions:\nQTS 4.4.3.1354 build 20200702 (and later)"
}
],
"source": {
"advisory": "QSA-20-22",
"discovery": "EXTERNAL"
},
"title": "Cleartext Transmission of Sensitive Information in SNMP",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@qnap.com",
"DATE_PUBLIC": "2020-12-30T02:55:00.000Z",
"ID": "CVE-2018-19944",
"STATE": "PUBLIC",
"TITLE": "Cleartext Transmission of Sensitive Information in SNMP"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "QTS",
"version": {
"version_data": [
{
"platform": "build 20200702",
"version_affected": "\u003c",
"version_value": "4.4.3.1354"
}
]
}
}
]
},
"vendor_name": "QNAP Systems Inc."
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Independent Security Evaluators"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A cleartext transmission of sensitive information vulnerability has been reported to affect certain QTS devices. If exploited, this vulnerability allows a remote attacker to gain access to sensitive information. QNAP have already fixed this vulnerability in the following versions: QTS 4.4.3.1354 build 20200702 (and later)"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-311 Missing Encryption of Sensitive Data"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-319 Cleartext Transmission of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-22",
"refsource": "MISC",
"url": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-22"
}
]
},
"solution": [
{
"lang": "en",
"value": "QNAP have already fixed this vulnerability in the following versions:\nQTS 4.4.3.1354 build 20200702 (and later)"
}
],
"source": {
"advisory": "QSA-20-22",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "2fd009eb-170a-4625-932b-17a53af1051f",
"assignerShortName": "qnap",
"cveId": "CVE-2018-19944",
"datePublished": "2020-12-31T16:33:27.820Z",
"dateReserved": "2018-12-07T00:00:00.000Z",
"dateUpdated": "2024-09-17T02:11:00.534Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-5401 (GCVE-0-2018-5401)
Vulnerability from cvelistv5 – Published: 2018-10-08 15:00 – Updated: 2024-09-17 03:37- CWE-319 - Cleartext Transmission of Sensitive Information
| URL | Tags |
|---|---|
| https://www.kb.cert.org/vuls/id/176301 | third-party-advisoryx_refsource_CERT-VN |
| https://www.us-cert.gov/ics/advisories/icsa-20-051-04 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Auto-Maskin | DCU-210E |
Affected:
3.7 , < 3.7
(custom)
|
|
| Auto-Maskin | RP-210E |
Affected:
3.7 , < 3.7
(custom)
|
|
| Auto-Maskin | Marine Pro Observer Android App |
Unknown:
0.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T05:33:44.365Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VU#176301",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "https://www.kb.cert.org/vuls/id/176301"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"platforms": [
"ARMv7"
],
"product": "DCU-210E",
"vendor": "Auto-Maskin",
"versions": [
{
"lessThan": "3.7",
"status": "affected",
"version": "3.7",
"versionType": "custom"
}
]
},
{
"platforms": [
"ARMv7"
],
"product": "RP-210E",
"vendor": "Auto-Maskin",
"versions": [
{
"lessThan": "3.7",
"status": "affected",
"version": "3.7",
"versionType": "custom"
}
]
},
{
"platforms": [
"android"
],
"product": "Marine Pro Observer Android App",
"vendor": "Auto-Maskin",
"versions": [
{
"status": "unknown",
"version": "0.1"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Reporters: Brian Satira, Brian Olson, Organization: Project Gunsway"
}
],
"datePublic": "2018-10-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The Auto-Maskin DCU 210E, RP-210E, and Marine Pro Observer Android App transmit sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The devices transmit process control information via unencrypted Modbus communications. Impact: An attacker can exploit this vulnerability to observe information about configurations, settings, what sensors are present and in use, and other information to aid in crafting spoofed messages. Requires access to the network. Affected releases are Auto-Maskin DCU-210E, RP-210E, and Marine Pro Observer Android App. Versions prior to 3.7 on ARMv7."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-24T14:50:24.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"name": "VU#176301",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "https://www.kb.cert.org/vuls/id/176301"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04"
}
],
"solutions": [
{
"lang": "en",
"value": "The devices should implement Modbus TCP Security Protocol (v21, 2018) per Modbus specifications over port 802 TCP, for Modbus TCP with encryption and authentication."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "The Auto-Maskin DCU 210E, RP-210E, and Marine Pro Observer Android App transmit sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"DATE_PUBLIC": "2018-10-01T04:00:00.000Z",
"ID": "CVE-2018-5401",
"STATE": "PUBLIC",
"TITLE": "The Auto-Maskin DCU 210E, RP-210E, and Marine Pro Observer Android App transmit sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DCU-210E",
"version": {
"version_data": [
{
"affected": "\u003c",
"platform": "ARMv7",
"version_affected": "\u003c",
"version_name": "3.7",
"version_value": "3.7"
}
]
}
},
{
"product_name": "RP-210E",
"version": {
"version_data": [
{
"affected": "\u003c",
"platform": "ARMv7",
"version_affected": "\u003c",
"version_name": "3.7",
"version_value": "3.7"
}
]
}
},
{
"product_name": "Marine Pro Observer Android App",
"version": {
"version_data": [
{
"affected": "?",
"platform": "android",
"version_affected": "?",
"version_value": "0.1"
}
]
}
}
]
},
"vendor_name": "Auto-Maskin"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Reporters: Brian Satira, Brian Olson, Organization: Project Gunsway"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Auto-Maskin DCU 210E, RP-210E, and Marine Pro Observer Android App transmit sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The devices transmit process control information via unencrypted Modbus communications. Impact: An attacker can exploit this vulnerability to observe information about configurations, settings, what sensors are present and in use, and other information to aid in crafting spoofed messages. Requires access to the network. Affected releases are Auto-Maskin DCU-210E, RP-210E, and Marine Pro Observer Android App. Versions prior to 3.7 on ARMv7."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-319: Cleartext Transmission of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "VU#176301",
"refsource": "CERT-VN",
"url": "https://www.kb.cert.org/vuls/id/176301"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04"
}
]
},
"solution": [
{
"lang": "en",
"value": "The devices should implement Modbus TCP Security Protocol (v21, 2018) per Modbus specifications over port 802 TCP, for Modbus TCP with encryption and authentication."
}
],
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2018-5401",
"datePublished": "2018-10-08T15:00:00.000Z",
"dateReserved": "2018-01-12T00:00:00.000Z",
"dateUpdated": "2024-09-17T03:37:46.527Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-5402 (GCVE-0-2018-5402)
Vulnerability from cvelistv5 – Published: 2018-10-08 15:00 – Updated: 2024-09-16 17:28- CWE-319 - Cleartext Transmission of Sensitive Information
| URL | Tags |
|---|---|
| https://www.kb.cert.org/vuls/id/176301 | third-party-advisoryx_refsource_CERT-VN |
| https://www.us-cert.gov/ics/advisories/icsa-20-051-04 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Auto-Maskin | DCU-210E |
Affected:
3.7 , < 3.7
(custom)
|
|
| Auto-Maskin | RP-210E |
Affected:
3.7 , < 3.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T05:33:44.364Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VU#176301",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "https://www.kb.cert.org/vuls/id/176301"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"platforms": [
"ARMv7"
],
"product": "DCU-210E",
"vendor": "Auto-Maskin",
"versions": [
{
"lessThan": "3.7",
"status": "affected",
"version": "3.7",
"versionType": "custom"
}
]
},
{
"platforms": [
"ARMv7"
],
"product": "RP-210E",
"vendor": "Auto-Maskin",
"versions": [
{
"lessThan": "3.7",
"status": "affected",
"version": "3.7",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Reporters: Brian Satira, Brian Olson, Organization: Project Gunsway"
}
],
"datePublic": "2018-10-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The Auto-Maskin DCU 210E, RP-210E, and Marine Pro Observer Android App use an embedded webserver that uses unencrypted plaintext for the transmission of the administrator PIN Impact: An attacker once authenticated can change configurations, upload new configuration files, and upload executable code via file upload for firmware updates. Requires access to the network. Affected releases are Auto-Maskin DCU-210E, RP-210E, and the Marine Pro Observer Android App. Versions prior to 3.7 on ARMv7."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-24T14:50:13.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"name": "VU#176301",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "https://www.kb.cert.org/vuls/id/176301"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04"
}
],
"solutions": [
{
"lang": "en",
"value": "The devices should implement TLS for authentication to administrator functions via embedded webserver."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "The Auto-Maskin DCU 210E, RP-210E, and Marine Pro Observer Android App use an embedded webserver that uses unencrypted plaintext for the transmission of the administrator PIN",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"DATE_PUBLIC": "2018-10-01T04:00:00.000Z",
"ID": "CVE-2018-5402",
"STATE": "PUBLIC",
"TITLE": "The Auto-Maskin DCU 210E, RP-210E, and Marine Pro Observer Android App use an embedded webserver that uses unencrypted plaintext for the transmission of the administrator PIN"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DCU-210E",
"version": {
"version_data": [
{
"affected": "\u003c",
"platform": "ARMv7",
"version_affected": "\u003c",
"version_name": "3.7",
"version_value": "3.7"
}
]
}
},
{
"product_name": "RP-210E",
"version": {
"version_data": [
{
"affected": "\u003c",
"platform": "ARMv7",
"version_affected": "\u003c",
"version_name": "3.7",
"version_value": "3.7"
}
]
}
}
]
},
"vendor_name": "Auto-Maskin"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Reporters: Brian Satira, Brian Olson, Organization: Project Gunsway"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Auto-Maskin DCU 210E, RP-210E, and Marine Pro Observer Android App use an embedded webserver that uses unencrypted plaintext for the transmission of the administrator PIN Impact: An attacker once authenticated can change configurations, upload new configuration files, and upload executable code via file upload for firmware updates. Requires access to the network. Affected releases are Auto-Maskin DCU-210E, RP-210E, and the Marine Pro Observer Android App. Versions prior to 3.7 on ARMv7."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-319: Cleartext Transmission of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "VU#176301",
"refsource": "CERT-VN",
"url": "https://www.kb.cert.org/vuls/id/176301"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-051-04"
}
]
},
"solution": [
{
"lang": "en",
"value": "The devices should implement TLS for authentication to administrator functions via embedded webserver."
}
],
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2018-5402",
"datePublished": "2018-10-08T15:00:00.000Z",
"dateReserved": "2018-01-12T00:00:00.000Z",
"dateUpdated": "2024-09-16T17:28:38.924Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-5471 (GCVE-0-2018-5471)
Vulnerability from cvelistv5 – Published: 2018-03-06 21:00 – Updated: 2024-08-05 05:33| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/103340 | vdb-entryx_refsource_BID |
| https://ics-cert.us-cert.gov/advisories/ICSA-18-065-01 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Hirschmann Automation and Control GmbH Classic Platform Switches |
Affected:
Hirschmann Automation and Control GmbH Classic Platform Switches
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T05:33:44.433Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "103340",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/103340"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Hirschmann Automation and Control GmbH Classic Platform Switches",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Hirschmann Automation and Control GmbH Classic Platform Switches"
}
]
}
],
"datePublic": "2018-03-06T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A Cleartext Transmission of Sensitive Information issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. A cleartext transmission of sensitive information vulnerability in the web interface has been identified, which may allow an attacker to obtain sensitive information through a successful man-in-the-middle attack."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-10T10:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "103340",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/103340"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2018-5471",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Hirschmann Automation and Control GmbH Classic Platform Switches",
"version": {
"version_data": [
{
"version_value": "Hirschmann Automation and Control GmbH Classic Platform Switches"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Cleartext Transmission of Sensitive Information issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. A cleartext transmission of sensitive information vulnerability in the web interface has been identified, which may allow an attacker to obtain sensitive information through a successful man-in-the-middle attack."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-319"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "103340",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/103340"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-5471",
"datePublished": "2018-03-06T21:00:00.000Z",
"dateReserved": "2018-01-12T00:00:00.000Z",
"dateUpdated": "2024-08-05T05:33:44.433Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-8842 (GCVE-0-2018-8842)
Vulnerability from cvelistv5 – Published: 2018-09-26 19:00 – Updated: 2024-09-16 17:18- CWE-319 - CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319
| URL | Tags |
|---|---|
| https://www.usa.philips.com/healthcare/about/cust… | x_refsource_CONFIRM |
| http://www.securityfocus.com/bid/105194 | vdb-entryx_refsource_BID |
| https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | e-Alert Unit (non-medical device) |
Affected:
R2.1 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T07:10:46.213Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"name": "105194",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105194"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "e-Alert Unit (non-medical device)",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "R2.1 and prior"
}
]
}
],
"datePublic": "2018-08-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to disclosure of personal contact information and application login credentials from within the same subnet."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-09-27T09:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"name": "105194",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105194"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-08-31T00:00:00",
"ID": "CVE-2018-8842",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "e-Alert Unit (non-medical device)",
"version": {
"version_data": [
{
"version_value": "R2.1 and prior"
}
]
}
}
]
},
"vendor_name": "Philips"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to disclosure of personal contact information and application login credentials from within the same subnet."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.usa.philips.com/healthcare/about/customer-support/product-security",
"refsource": "CONFIRM",
"url": "https://www.usa.philips.com/healthcare/about/customer-support/product-security"
},
{
"name": "105194",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105194"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-8842",
"datePublished": "2018-09-26T19:00:00.000Z",
"dateReserved": "2018-03-20T00:00:00.000Z",
"dateUpdated": "2024-09-16T17:18:41.660Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-8855 (GCVE-0-2018-8855)
Vulnerability from cvelistv5 – Published: 2018-07-24 17:00 – Updated: 2024-09-17 01:10- CWE-319 - CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319
| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-18-200-03 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Echelon | SmartServer 1 |
Affected:
all versions
|
|
| Echelon | SmartServer 2 |
Affected:
all versions prior to release 4.11.007
|
|
| Echelon | i.LON 100 |
Affected:
all versions
|
|
| Echelon | i.LON 600 |
Affected:
all versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T07:10:46.267Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-200-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SmartServer 1",
"vendor": "Echelon",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "SmartServer 2",
"vendor": "Echelon",
"versions": [
{
"status": "affected",
"version": "all versions prior to release 4.11.007"
}
]
},
{
"product": "i.LON 100",
"vendor": "Echelon",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "i.LON 600",
"vendor": "Echelon",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"datePublic": "2018-07-19T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices allow unencrypted Web connections by default, and devices can receive configuration and firmware updates by unsecure FTP."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-07-24T16:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-200-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-07-19T00:00:00",
"ID": "CVE-2018-8855",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SmartServer 1",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "SmartServer 2",
"version": {
"version_data": [
{
"version_value": "all versions prior to release 4.11.007"
}
]
}
},
{
"product_name": "i.LON 100",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "i.LON 600",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
}
]
},
"vendor_name": "Echelon"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices allow unencrypted Web connections by default, and devices can receive configuration and firmware updates by unsecure FTP."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-200-03",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-200-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-8855",
"datePublished": "2018-07-24T17:00:00.000Z",
"dateReserved": "2018-03-20T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:10:42.995Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-8929 (GCVE-0-2018-8929)
Vulnerability from cvelistv5 – Published: 2018-07-06 12:00 – Updated: 2024-09-16 20:41- CWE-319 - Cleartext Transmission of Sensitive Information
| URL | Tags |
|---|---|
| https://www.synology.com/en-global/support/securi… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Synology | SSL VPN Client |
Affected:
unspecified , < 1.2.4-0224
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T07:10:46.759Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.synology.com/en-global/support/security/Synology_SA_18_19"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SSL VPN Client",
"vendor": "Synology",
"versions": [
{
"lessThan": "1.2.4-0224",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2018-07-06T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Improper restriction of communication channel to intended endpoints vulnerability in HTTP daemon in Synology SSL VPN Client before 1.2.4-0224 allows remote attackers to conduct man-in-the-middle attacks via a crafted payload."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-12T12:50:49.000Z",
"orgId": "db201096-a0cc-46c7-9a55-61d9e221bf01",
"shortName": "synology"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.synology.com/en-global/support/security/Synology_SA_18_19"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@synology.com",
"DATE_PUBLIC": "2018-07-06T00:00:00",
"ID": "CVE-2018-8929",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SSL VPN Client",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_value": "1.2.4-0224"
}
]
}
}
]
},
"vendor_name": "Synology"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper restriction of communication channel to intended endpoints vulnerability in HTTP daemon in Synology SSL VPN Client before 1.2.4-0224 allows remote attackers to conduct man-in-the-middle attacks via a crafted payload."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-319: Cleartext Transmission of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.synology.com/en-global/support/security/Synology_SA_18_19",
"refsource": "CONFIRM",
"url": "https://www.synology.com/en-global/support/security/Synology_SA_18_19"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "db201096-a0cc-46c7-9a55-61d9e221bf01",
"assignerShortName": "synology",
"cveId": "CVE-2018-8929",
"datePublished": "2018-07-06T12:00:00.000Z",
"dateReserved": "2018-03-22T00:00:00.000Z",
"dateUpdated": "2024-09-16T20:41:43.731Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-10926 (GCVE-0-2019-10926)
Vulnerability from cvelistv5 – Published: 2019-06-12 13:47 – Updated: 2024-08-04 22:40- CWE-319 - Cleartext Transmission of Sensitive Information
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/108725 | vdb-entryx_refsource_BID |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC MV400 family |
Affected:
All Versions < V7.0.6
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.135Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "108725",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/108725"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC MV400 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c V7.0.6"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC MV400 family (All Versions \u003c V7.0.6). Communication with the device is not encrypted. Data transmitted between the device and the user can be obtained by an attacker in a privileged network position. The security vulnerability can be exploited by an attacker in a privileged network position which allows eavesdropping the communication between the affected device and the user. The user must invoke a session. Successful exploitation of the vulnerability compromises confidentiality of the data transmitted."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-15T17:03:29.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "108725",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/108725"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-10926",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC MV400 family",
"version": {
"version_data": [
{
"version_value": "All Versions \u003c V7.0.6"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC MV400 family (All Versions \u003c V7.0.6). Communication with the device is not encrypted. Data transmitted between the device and the user can be obtained by an attacker in a privileged network position. The security vulnerability can be exploited by an attacker in a privileged network position which allows eavesdropping the communication between the affected device and the user. The user must invoke a session. Successful exploitation of the vulnerability compromises confidentiality of the data transmitted."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-319: Cleartext Transmission of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "108725",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/108725"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-10926",
"datePublished": "2019-06-12T13:47:56.000Z",
"dateReserved": "2019-04-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T22:40:15.135Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-11276 (GCVE-0-2019-11276)
Vulnerability from cvelistv5 – Published: 2019-08-19 14:49 – Updated: 2024-09-16 16:13- CWE-319 - Cleartext Transmission of Sensitive Information
| URL | Tags |
|---|---|
| https://pivotal.io/security/cve-2019-11276 | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Pivotal | Pivotal Application Service (PAS) |
Affected:
2.3 , < 2.3.16
(custom)
Affected: 2.4 , < 2.4.12 (custom) Affected: 2.5 , < 2.5.8 (custom) Affected: 2.6 , < 2.6.3 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:48:09.149Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://pivotal.io/security/cve-2019-11276"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Pivotal Application Service (PAS)",
"vendor": "Pivotal",
"versions": [
{
"lessThan": "2.3.16",
"status": "affected",
"version": "2.3",
"versionType": "custom"
},
{
"lessThan": "2.4.12",
"status": "affected",
"version": "2.4",
"versionType": "custom"
},
{
"lessThan": "2.5.8",
"status": "affected",
"version": "2.5",
"versionType": "custom"
},
{
"lessThan": "2.6.3",
"status": "affected",
"version": "2.6",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-08-16T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Pivotal Apps Manager, included in Pivotal Application Service versions 2.3.x prior to 2.3.16, 2.4.x prior to 2.4.12, 2.5.x prior to 2.5.8, and 2.6.x prior to 2.6.3, makes a request to the /cloudapplication endpoint via Spring actuator, and subsequent requests via unsecured http. An adjacent unauthenticated user could eavesdrop on the network traffic and gain access to the unencrypted token allowing the attacker to read the type of access a user has over an app. They may also modify the logging level, potentially leading to lost information that would otherwise have been logged."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319: Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-08-19T14:49:27.000Z",
"orgId": "862b2186-222f-48b9-af87-f1fb7bb26d03",
"shortName": "pivotal"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://pivotal.io/security/cve-2019-11276"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Apps Manager sends tokens to Spring apps via HTTP",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@pivotal.io",
"DATE_PUBLIC": "2019-08-16T19:23:14.737Z",
"ID": "CVE-2019-11276",
"STATE": "PUBLIC",
"TITLE": "Apps Manager sends tokens to Spring apps via HTTP"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Pivotal Application Service (PAS)",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_name": "2.3",
"version_value": "2.3.16"
},
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_name": "2.4",
"version_value": "2.4.12"
},
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_name": "2.5",
"version_value": "2.5.8"
},
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_name": "2.6",
"version_value": "2.6.3"
}
]
}
}
]
},
"vendor_name": "Pivotal"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Pivotal Apps Manager, included in Pivotal Application Service versions 2.3.x prior to 2.3.16, 2.4.x prior to 2.4.12, 2.5.x prior to 2.5.8, and 2.6.x prior to 2.6.3, makes a request to the /cloudapplication endpoint via Spring actuator, and subsequent requests via unsecured http. An adjacent unauthenticated user could eavesdrop on the network traffic and gain access to the unencrypted token allowing the attacker to read the type of access a user has over an app. They may also modify the logging level, potentially leading to lost information that would otherwise have been logged."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-319: Cleartext Transmission of Sensitive Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://pivotal.io/security/cve-2019-11276",
"refsource": "CONFIRM",
"url": "https://pivotal.io/security/cve-2019-11276"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "862b2186-222f-48b9-af87-f1fb7bb26d03",
"assignerShortName": "pivotal",
"cveId": "CVE-2019-11276",
"datePublished": "2019-08-19T14:49:27.910Z",
"dateReserved": "2019-04-18T00:00:00.000Z",
"dateUpdated": "2024-09-16T16:13:54.745Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-18231 (GCVE-0-2019-18231)
Vulnerability from cvelistv5 – Published: 2021-03-17 18:12 – Updated: 2024-08-05 01:47- CWE-319 - CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-054-03 | x_refsource_MISC |
| https://ep.advantech-bb.cz/support/router-models/… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Advantech Spectre RT ERT351 |
Affected:
Versions 5.1.3 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T01:47:14.006Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-054-03"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ep.advantech-bb.cz/support/router-models/download/511/sa-2021-01-fw-5.1.3-and-older-en.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Advantech Spectre RT ERT351",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 5.1.3 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Advantech Spectre RT ERT351 Versions 5.1.3 and prior logins and passwords are transmitted in clear text form, which may allow an attacker to intercept the request."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-17T18:12:07.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-054-03"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ep.advantech-bb.cz/support/router-models/download/511/sa-2021-01-fw-5.1.3-and-older-en.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2019-18231",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Advantech Spectre RT ERT351",
"version": {
"version_data": [
{
"version_value": "Versions 5.1.3 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Advantech Spectre RT ERT351 Versions 5.1.3 and prior logins and passwords are transmitted in clear text form, which may allow an attacker to intercept the request."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-054-03",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-054-03"
},
{
"name": "https://ep.advantech-bb.cz/support/router-models/download/511/sa-2021-01-fw-5.1.3-and-older-en.pdf",
"refsource": "MISC",
"url": "https://ep.advantech-bb.cz/support/router-models/download/511/sa-2021-01-fw-5.1.3-and-older-en.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2019-18231",
"datePublished": "2021-03-17T18:12:07.000Z",
"dateReserved": "2019-10-22T00:00:00.000Z",
"dateUpdated": "2024-08-05T01:47:14.006Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
Phase: Architecture and Design
Description:
- Before transmitting, encrypt the data using reliable, confidentiality-protecting cryptographic protocols.
Mitigation
Phase: Implementation
Description:
- When using web applications with SSL, use SSL for the entire session from login to logout, not just for the initial login page.
Mitigation
Phase: Implementation
Description:
- When designing hardware platforms, ensure that approved encryption algorithms (such as those recommended by NIST) protect paths from security critical data to trusted user applications.
Mitigation
Phase: Testing
Description:
- Use tools and techniques that require manual (human) analysis, such as penetration testing, threat modeling, and interactive tools that allow the tester to record and modify an active session. These may be more effective than strictly automated techniques. This is especially the case with weaknesses that are related to design and business rules.
Mitigation
Phase: Operation
Description:
- Configure servers to use encrypted channels for communication, which may include SSL or other secure protocols.
CAPEC-102: Session Sidejacking
Session sidejacking takes advantage of an unencrypted communication channel between a victim and target system. The attacker sniffs traffic on a network looking for session tokens in unencrypted traffic. Once a session token is captured, the attacker performs malicious actions by using the stolen token with the targeted application to impersonate the victim. This attack is a specific method of session hijacking, which is exploiting a valid session token to gain unauthorized access to a target system or information. Other methods to perform a session hijacking are session fixation, cross-site scripting, or compromising a user or server machine and stealing the session token.
CAPEC-117: Interception
An adversary monitors data streams to or from the target for information gathering purposes. This attack may be undertaken to solely gather sensitive information or to support a further attack against the target. This attack pattern can involve sniffing network traffic as well as other types of data streams (e.g. radio). The adversary can attempt to initiate the establishment of a data stream or passively observe the communications as they unfold. In all variants of this attack, the adversary is not the intended recipient of the data stream. In contrast to other means of gathering information (e.g., targeting data leaks), the adversary must actively position themself so as to observe explicit data channels (e.g. network traffic) and read the content. However, this attack differs from a Adversary-In-the-Middle (CAPEC-94) attack, as the adversary does not alter the content of the communications nor forward data to the intended recipient.
CAPEC-383: Harvesting Information via API Event Monitoring
An adversary hosts an event within an application framework and then monitors the data exchanged during the course of the event for the purpose of harvesting any important data leaked during the transactions. One example could be harvesting lists of usernames or userIDs for the purpose of sending spam messages to those users. One example of this type of attack involves the adversary creating an event within the sub-application. Assume the adversary hosts a "virtual sale" of rare items. As other users enter the event, the attacker records via AiTM (CAPEC-94) proxy the user_ids and usernames of everyone who attends. The adversary would then be able to spam those users within the application using an automated script.
CAPEC-477: Signature Spoofing by Mixing Signed and Unsigned Content
An attacker exploits the underlying complexity of a data structure that allows for both signed and unsigned content, to cause unsigned data to be processed as though it were signed data.
CAPEC-65: Sniff Application Code
An adversary passively sniffs network communications and captures application code bound for an authorized client. Once obtained, they can use it as-is, or through reverse-engineering glean sensitive information or exploit the trust relationship between the client and server. Such code may belong to a dynamic update to the client, a patch being applied to a client component or any such interaction where the client is authorized to communicate with the server.