CWE-284

Improper Access Control

The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

CVE-2019-5487 (GCVE-0-2019-5487)

Vulnerability from cvelistv5 – Published: 2019-12-18 21:00 – Updated: 2024-08-04 19:54
VLAI
Summary
An improper access control vulnerability exists in Gitlab EE <v12.3.3, <v12.2.7, & <v12.1.13 that allowed the group search feature with Elasticsearch to return private code, merge requests and commits.
Severity
No CVSS data available.
CWE
  • CWE-284 - Improper Access Control - Generic (CWE-284)
Assigner
References
URL Tags
https://hackerone.com/reports/692252 x_refsource_MISC
Impacted products
Vendor Product Version
n/a GitLab EE Affected: 12.3.3, 12.2.7, 12.1.13
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:54:53.564Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://hackerone.com/reports/692252"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "GitLab EE",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "12.3.3, 12.2.7, 12.1.13"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An improper access control vulnerability exists in Gitlab EE \u003cv12.3.3, \u003cv12.2.7, \u0026 \u003cv12.1.13 that allowed the group search feature with Elasticsearch to return private code, merge requests and commits."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "Improper Access Control - Generic (CWE-284)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-12-18T21:00:29.000Z",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://hackerone.com/reports/692252"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "support@hackerone.com",
          "ID": "CVE-2019-5487",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "GitLab EE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "12.3.3, 12.2.7, 12.1.13"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An improper access control vulnerability exists in Gitlab EE \u003cv12.3.3, \u003cv12.2.7, \u0026 \u003cv12.1.13 that allowed the group search feature with Elasticsearch to return private code, merge requests and commits."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper Access Control - Generic (CWE-284)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://hackerone.com/reports/692252",
              "refsource": "MISC",
              "url": "https://hackerone.com/reports/692252"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2019-5487",
    "datePublished": "2019-12-18T21:00:29.000Z",
    "dateReserved": "2019-01-04T00:00:00.000Z",
    "dateUpdated": "2024-08-04T19:54:53.564Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-5617 (GCVE-0-2019-5617)

Vulnerability from cvelistv5 – Published: 2019-11-06 18:30 – Updated: 2024-09-17 02:21
VLAI
Title
C4G BLIS Improper Access Control
Summary
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Computing For Good Basic Laboratory Information System Affected: unspecified , ≤ 3.4 (custom)
Create a notification for this product.
Date Public
2019-09-10 00:00
Credits
This vulnerability was first discovered privately and reported internally by C4G BLIS team member Aditi Shah in December 2018. Jacob Robles of Rapid7 rediscovered and reported these issues in March of 2019 per Rapid7's vulnerability disclosure policy (https://www.rapid7.com/security/disclosure/).
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:01:51.813Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Basic Laboratory Information System",
          "vendor": "Computing For Good",
          "versions": [
            {
              "lessThanOrEqual": "3.4",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "This vulnerability was first discovered privately and reported internally by C4G BLIS team member Aditi Shah in December 2018. Jacob Robles of Rapid7 rediscovered and reported these issues in March of 2019 per Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/security/disclosure/)."
        }
      ],
      "datePublic": "2019-09-10T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Computing For Good\u0027s Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, \"Improper Access Control.\" As a result, an unauthenticated user may change the password of any administrator-level user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-06T18:30:42.000Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "C4G BLIS users should update to version 3.5 or later."
        }
      ],
      "source": {
        "advisory": "R7-2019-09.1",
        "discovery": "EXTERNAL"
      },
      "title": "C4G BLIS Improper Access Control",
      "x_generator": {
        "engine": "Vulnogram 0.0.8"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2019-09-10T13:05:00.000Z",
          "ID": "CVE-2019-5617",
          "STATE": "PUBLIC",
          "TITLE": "C4G BLIS Improper Access Control"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Basic Laboratory Information System",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "3.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Computing For Good"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "This vulnerability was first discovered privately and reported internally by C4G BLIS team member Aditi Shah in December 2018. Jacob Robles of Rapid7 rediscovered and reported these issues in March of 2019 per Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/security/disclosure/)."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Computing For Good\u0027s Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, \"Improper Access Control.\" As a result, an unauthenticated user may change the password of any administrator-level user."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.8"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/",
              "refsource": "MISC",
              "url": "https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "C4G BLIS users should update to version 3.5 or later."
          }
        ],
        "source": {
          "advisory": "R7-2019-09.1",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2019-5617",
    "datePublished": "2019-11-06T18:30:42.339Z",
    "dateReserved": "2019-01-07T00:00:00.000Z",
    "dateUpdated": "2024-09-17T02:21:04.696Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-5643 (GCVE-0-2019-5643)

Vulnerability from cvelistv5 – Published: 2019-11-06 18:30 – Updated: 2024-09-16 19:14
VLAI
Title
C4G BLIS Improper Access Control
Summary
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may enumerate the user names and facility names in use on a particular installation.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Computing For Good Basic Laboratory Information System Affected: unspecified , ≤ 3.5 (custom)
Create a notification for this product.
Date Public
2019-09-10 00:00
Credits
This vulnerability was first discovered privately and reported internally by C4G BLIS team member Aditi Shah in December 2018. Jacob Robles of Rapid7 rediscovered and reported these issues in March of 2019 per Rapid7's vulnerability disclosure policy (https://www.rapid7.com/security/disclosure/).
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:01:52.011Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Basic Laboratory Information System",
          "vendor": "Computing For Good",
          "versions": [
            {
              "lessThanOrEqual": "3.5",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "This vulnerability was first discovered privately and reported internally by C4G BLIS team member Aditi Shah in December 2018. Jacob Robles of Rapid7 rediscovered and reported these issues in March of 2019 per Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/security/disclosure/)."
        }
      ],
      "datePublic": "2019-09-10T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Computing For Good\u0027s Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, \"Improper Access Control.\" As a result, an unauthenticated user may enumerate the user names and facility names in use on a particular installation."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-06T18:30:43.000Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "C4G BLIS users should update to version 3.51 or later."
        }
      ],
      "source": {
        "advisory": "R7-2019-09.2",
        "discovery": "EXTERNAL"
      },
      "title": "C4G BLIS Improper Access Control",
      "x_generator": {
        "engine": "Vulnogram 0.0.8"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2019-09-10T13:05:00.000Z",
          "ID": "CVE-2019-5643",
          "STATE": "PUBLIC",
          "TITLE": "C4G BLIS Improper Access Control"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Basic Laboratory Information System",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "3.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Computing For Good"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "This vulnerability was first discovered privately and reported internally by C4G BLIS team member Aditi Shah in December 2018. Jacob Robles of Rapid7 rediscovered and reported these issues in March of 2019 per Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/security/disclosure/)."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Computing For Good\u0027s Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, \"Improper Access Control.\" As a result, an unauthenticated user may enumerate the user names and facility names in use on a particular installation."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.8"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/",
              "refsource": "MISC",
              "url": "https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "C4G BLIS users should update to version 3.51 or later."
          }
        ],
        "source": {
          "advisory": "R7-2019-09.2",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2019-5643",
    "datePublished": "2019-11-06T18:30:43.187Z",
    "dateReserved": "2019-01-07T00:00:00.000Z",
    "dateUpdated": "2024-09-16T19:14:34.337Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-5644 (GCVE-0-2019-5644)

Vulnerability from cvelistv5 – Published: 2019-11-06 18:30 – Updated: 2024-09-16 22:41
VLAI
Title
C4G BLIS Improper Access Control
Summary
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Computing For Good Basic Laboratory Information System Affected: unspecified , ≤ 3.5 (custom)
Create a notification for this product.
Date Public
2019-09-10 00:00
Credits
This vulnerability was first discovered privately and reported internally by C4G BLIS team member Aditi Shah in December 2018. Jacob Robles of Rapid7 rediscovered and reported these issues in March of 2019 per Rapid7's vulnerability disclosure policy (https://www.rapid7.com/security/disclosure/).
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:01:52.195Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Basic Laboratory Information System",
          "vendor": "Computing For Good",
          "versions": [
            {
              "lessThanOrEqual": "3.5",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "This vulnerability was first discovered privately and reported internally by C4G BLIS team member Aditi Shah in December 2018. Jacob Robles of Rapid7 rediscovered and reported these issues in March of 2019 per Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/security/disclosure/)."
        }
      ],
      "datePublic": "2019-09-10T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Computing For Good\u0027s Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, \"Improper Access Control.\" As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-06T18:30:43.000Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "C4G BLIS users should update to version 3.51 or later."
        }
      ],
      "source": {
        "advisory": "R7-2019-09.3",
        "discovery": "EXTERNAL"
      },
      "title": "C4G BLIS Improper Access Control",
      "x_generator": {
        "engine": "Vulnogram 0.0.8"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2019-09-10T13:05:00.000Z",
          "ID": "CVE-2019-5644",
          "STATE": "PUBLIC",
          "TITLE": "C4G BLIS Improper Access Control"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Basic Laboratory Information System",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "3.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Computing For Good"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "This vulnerability was first discovered privately and reported internally by C4G BLIS team member Aditi Shah in December 2018. Jacob Robles of Rapid7 rediscovered and reported these issues in March of 2019 per Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/security/disclosure/)."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Computing For Good\u0027s Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, \"Improper Access Control.\" As a result, an unauthenticated user may alter several facets of a user account, including promoting any user to an administrator."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.8"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/",
              "refsource": "MISC",
              "url": "https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "C4G BLIS users should update to version 3.51 or later."
          }
        ],
        "source": {
          "advisory": "R7-2019-09.3",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2019-5644",
    "datePublished": "2019-11-06T18:30:43.639Z",
    "dateReserved": "2019-01-07T00:00:00.000Z",
    "dateUpdated": "2024-09-16T22:41:06.846Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6140 (GCVE-0-2019-6140)

Vulnerability from cvelistv5 – Published: 2019-04-09 20:51 – Updated: 2024-08-04 20:16
VLAI
Summary
A configuration issue has been discovered in Forcepoint Email Security 8.4.x and 8.5.x: the product is left in a vulnerable state if the hybrid registration process is not completed.
Severity
No CVSS data available.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Forcepoint Forcepoint Email Security Affected: 8.4
Affected: 8.5
Create a notification for this product.
Date Public
2019-04-03 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:16:23.961Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://help.forcepoint.com/security/CVE/CVE-2019-6140.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Forcepoint Email Security",
          "vendor": "Forcepoint",
          "versions": [
            {
              "status": "affected",
              "version": "8.4"
            },
            {
              "status": "affected",
              "version": "8.5"
            }
          ]
        }
      ],
      "datePublic": "2019-04-03T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A configuration issue has been discovered in Forcepoint Email Security 8.4.x and 8.5.x: the product is left in a vulnerable state if the hybrid registration process is not completed."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-10T17:07:51.000Z",
        "orgId": "e23ea22c-8c39-4eff-8980-2881e5ae54e2",
        "shortName": "forcepoint"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://help.forcepoint.com/security/CVE/CVE-2019-6140.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@forcepoint.com",
          "ID": "CVE-2019-6140",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Forcepoint Email Security",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "8.4"
                          },
                          {
                            "version_value": "8.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Forcepoint"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A configuration issue has been discovered in Forcepoint Email Security 8.4.x and 8.5.x: the product is left in a vulnerable state if the hybrid registration process is not completed."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://help.forcepoint.com/security/CVE/CVE-2019-6140.html",
              "refsource": "CONFIRM",
              "url": "https://help.forcepoint.com/security/CVE/CVE-2019-6140.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e23ea22c-8c39-4eff-8980-2881e5ae54e2",
    "assignerShortName": "forcepoint",
    "cveId": "CVE-2019-6140",
    "datePublished": "2019-04-09T20:51:32.000Z",
    "dateReserved": "2019-01-11T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:16:23.961Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6144 (GCVE-0-2019-6144)

Vulnerability from cvelistv5 – Published: 2019-10-23 18:57 – Updated: 2024-08-04 20:16
VLAI
Summary
This vulnerability allows a normal (non-admin) user to disable the Forcepoint One Endpoint (versions 19.04 through 19.08) and bypass DLP and Web protection.
Severity
No CVSS data available.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
n/a Forcepoint One Endpoint Affected: Versions 19.04 through 19.08
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:16:24.328Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://help.forcepoint.com/security/CVE/CVE-2019-6144.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Forcepoint One Endpoint",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 19.04 through 19.08"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows a normal (non-admin) user to disable the Forcepoint One Endpoint (versions 19.04 through 19.08) and bypass DLP and Web protection."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-10T17:05:08.000Z",
        "orgId": "e23ea22c-8c39-4eff-8980-2881e5ae54e2",
        "shortName": "forcepoint"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://help.forcepoint.com/security/CVE/CVE-2019-6144.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@forcepoint.com",
          "ID": "CVE-2019-6144",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Forcepoint One Endpoint",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions 19.04 through 19.08"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows a normal (non-admin) user to disable the Forcepoint One Endpoint (versions 19.04 through 19.08) and bypass DLP and Web protection."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://help.forcepoint.com/security/CVE/CVE-2019-6144.html",
              "refsource": "CONFIRM",
              "url": "https://help.forcepoint.com/security/CVE/CVE-2019-6144.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e23ea22c-8c39-4eff-8980-2881e5ae54e2",
    "assignerShortName": "forcepoint",
    "cveId": "CVE-2019-6144",
    "datePublished": "2019-10-23T18:57:51.000Z",
    "dateReserved": "2019-01-11T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:16:24.328Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6193 (GCVE-0-2019-6193)

Vulnerability from cvelistv5 – Published: 2020-02-14 17:10 – Updated: 2024-09-17 02:47
VLAI
Summary
An information disclosure vulnerability was reported in Lenovo XClarity Administrator (LXCA) versions prior to 2.6.6 that could allow unauthenticated access to some configuration files which may contain usernames, license keys, IP addresses, and encrypted password hashes.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Lenovo XClarity Administrator (LXCA) Affected: unspecified , < 2.6.6 (custom)
Create a notification for this product.
Date Public
2020-02-14 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:16:24.476Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.lenovo.com/us/en/product_security/LEN-29477"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "XClarity Administrator (LXCA)",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "2.6.6",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2020-02-14T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An information disclosure vulnerability was reported in Lenovo XClarity Administrator (LXCA) versions prior to 2.6.6 that could allow unauthenticated access to some configuration files which may contain usernames, license keys, IP addresses, and encrypted password hashes."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-02-14T17:10:26.000Z",
        "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "shortName": "lenovo"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.lenovo.com/us/en/product_security/LEN-29477"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update your LXCA installation to version 2.6.6 or later. Installation note:  You will need to update to LXCA 2.6.0 before installing the latest fix bundle (v 2.6.6)."
        }
      ],
      "source": {
        "advisory": "LEN-29477",
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@lenovo.com",
          "DATE_PUBLIC": "2020-02-14T17:00:00.000Z",
          "ID": "CVE-2019-6193",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "XClarity Administrator (LXCA)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "2.6.6"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Lenovo"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An information disclosure vulnerability was reported in Lenovo XClarity Administrator (LXCA) versions prior to 2.6.6 that could allow unauthenticated access to some configuration files which may contain usernames, license keys, IP addresses, and encrypted password hashes."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.lenovo.com/us/en/product_security/LEN-29477",
              "refsource": "MISC",
              "url": "https://support.lenovo.com/us/en/product_security/LEN-29477"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update your LXCA installation to version 2.6.6 or later. Installation note:  You will need to update to LXCA 2.6.0 before installing the latest fix bundle (v 2.6.6)."
          }
        ],
        "source": {
          "advisory": "LEN-29477",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
    "assignerShortName": "lenovo",
    "cveId": "CVE-2019-6193",
    "datePublished": "2020-02-14T17:10:26.717Z",
    "dateReserved": "2019-01-11T00:00:00.000Z",
    "dateUpdated": "2024-09-17T02:47:43.822Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6517 (GCVE-0-2019-6517)

Vulnerability from cvelistv5 – Published: 2019-02-06 21:00 – Updated: 2024-09-16 20:22
VLAI
Summary
BD FACSLyric Research Use Only, Windows 10 Professional Operating System, U.S. and Malaysian Releases, between November 2017 and November 2018 and BD FACSLyric IVD Windows 10 Professional Operating System US release does not properly enforce user access control to privileged accounts, which may allow for unauthorized access to administrative level functions.
Severity
No CVSS data available.
CWE
  • CWE-284 - IMPROPER ACCESS CONTROL CWE-284
Assigner
References
Impacted products
Vendor Product Version
ICS-CERT BD FACSLyric Affected: BD FACSLyric Research Use Only, Windows 10 Professional Operating System, U.S. and Malaysian Releases, between November 2017 and November 2018 and BD FACSLyric IVD Windows 10 Professional Operating System US release.
Create a notification for this product.
Date Public
2019-01-29 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:21.440Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "106766",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/106766"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-19-029-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "BD FACSLyric",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "BD FACSLyric Research Use Only, Windows 10 Professional Operating System, U.S. and Malaysian Releases, between November 2017 and November 2018 and BD FACSLyric IVD Windows 10 Professional Operating System US release."
            }
          ]
        }
      ],
      "datePublic": "2019-01-29T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "BD FACSLyric Research Use Only, Windows 10 Professional Operating System, U.S. and Malaysian Releases, between November 2017 and November 2018 and BD FACSLyric IVD Windows 10 Professional Operating System US release does not properly enforce user access control to privileged accounts, which may allow for unauthorized access to administrative level functions."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "IMPROPER ACCESS CONTROL CWE-284",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-02-07T10:57:02.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "106766",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/106766"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-19-029-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2019-01-29T00:00:00",
          "ID": "CVE-2019-6517",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "BD FACSLyric",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "BD FACSLyric Research Use Only, Windows 10 Professional Operating System, U.S. and Malaysian Releases, between November 2017 and November 2018 and BD FACSLyric IVD Windows 10 Professional Operating System US release."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "BD FACSLyric Research Use Only, Windows 10 Professional Operating System, U.S. and Malaysian Releases, between November 2017 and November 2018 and BD FACSLyric IVD Windows 10 Professional Operating System US release does not properly enforce user access control to privileged accounts, which may allow for unauthorized access to administrative level functions."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER ACCESS CONTROL CWE-284"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "106766",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/106766"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-19-029-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-19-029-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-6517",
    "datePublished": "2019-02-06T21:00:00.000Z",
    "dateReserved": "2019-01-22T00:00:00.000Z",
    "dateUpdated": "2024-09-16T20:22:23.258Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6520 (GCVE-0-2019-6520)

Vulnerability from cvelistv5 – Published: 2019-03-05 21:00 – Updated: 2024-09-16 19:01
VLAI
Summary
Moxa IKS and EDS does not properly check authority on server side, which results in a read-only user being able to perform arbitrary configuration changes.
Severity
No CVSS data available.
CWE
  • CWE-284 - Improper access control CWE-284
Assigner
References
Impacted products
Vendor Product Version
ICS-CERT Moxa IKS, EDS Affected: IKS-G6824A series Versions 4.5 and prior, EDS-405A series Version 3.8 and prior, EDS-408A series Version 3.8 and prior, and EDS-510A series Version 3.8 and prior
Create a notification for this product.
Date Public
2019-03-05 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:21.422Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-057-01"
          },
          {
            "name": "107178",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/107178"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Moxa IKS, EDS",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "IKS-G6824A series Versions 4.5 and prior, EDS-405A series Version 3.8 and prior, EDS-408A series Version 3.8 and prior, and EDS-510A series Version 3.8 and prior"
            }
          ]
        }
      ],
      "datePublic": "2019-03-05T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Moxa IKS and EDS does not properly check authority on server side, which results in a read-only user being able to perform arbitrary configuration changes."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "Improper access control CWE-284",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-06T10:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-057-01"
        },
        {
          "name": "107178",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/107178"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2019-03-05T00:00:00",
          "ID": "CVE-2019-6520",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Moxa IKS, EDS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "IKS-G6824A series Versions 4.5 and prior, EDS-405A series Version 3.8 and prior, EDS-408A series Version 3.8 and prior, and EDS-510A series Version 3.8 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Moxa IKS and EDS does not properly check authority on server side, which results in a read-only user being able to perform arbitrary configuration changes."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper access control CWE-284"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-057-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-057-01"
            },
            {
              "name": "107178",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/107178"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-6520",
    "datePublished": "2019-03-05T21:00:00.000Z",
    "dateReserved": "2019-01-22T00:00:00.000Z",
    "dateUpdated": "2024-09-16T19:01:03.479Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6538 (GCVE-0-2019-6538)

Vulnerability from cvelistv5 – Published: 2019-03-25 21:26 – Updated: 2025-05-22 19:26
VLAI
Title
Medtronic Conexus Radio Frequency Telemetry Protocol Improper Access Control
Summary
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.
CWE
Assigner
References
Impacted products
Vendor Product Version
Medtronic Conexus Radio Frequency Telemetry Protocol Affected: All versions
Create a notification for this product.
Medtronic MyCareLink Monitor Affected: 24950
Affected: 24952
Create a notification for this product.
Medtronic CareLink Monitor Affected: 2490C
Create a notification for this product.
Medtronic CareLink 2090 Programmer Affected: All versions
Create a notification for this product.
Medtronic Amplia CRT-D Affected: All versions
Create a notification for this product.
Medtronic Claria CRT-D Affected: All versions
Create a notification for this product.
Medtronic Compia CRT-D Affected: All versions
Create a notification for this product.
Medtronic Concerto CRT-D Affected: All versions
Create a notification for this product.
Medtronic Concerto II CRT-D Affected: All versions
Create a notification for this product.
Medtronic Consulta CRT-D Affected: All versions
Create a notification for this product.
Medtronic Evera ICD Affected: All versions
Create a notification for this product.
Medtronic Maximo II CRT-D Affected: All versions
Create a notification for this product.
Medtronic Maximo II ICD Affected: All versions
Create a notification for this product.
Medtronic Mirro ICD Affected: All versions
Create a notification for this product.
Medtronic Nayamed ND ICD Affected: All versions
Create a notification for this product.
Medtronic Primo ICD Affected: All versions
Create a notification for this product.
Medtronic Protecta ICD, Protecta CRT-D Affected: All versions
Create a notification for this product.
Medtronic Secura ICD Affected: All versions
Create a notification for this product.
Medtronic Virtuoso ICD Affected: All versions
Create a notification for this product.
Medtronic Virtuoso II ICD Affected: All versions
Create a notification for this product.
Medtronic Visia AF ICD Affected: All versions
Create a notification for this product.
Medtronic Viva CRT-D Affected: All versions
Create a notification for this product.
Medtronic Brava CRT-D Affected: All versions
Create a notification for this product.
Medtronic Mirro MRI ICD Affected: All versions
Create a notification for this product.
Date Public
2019-03-21 06:00
Credits
Peter Morgan of Clever Security; Dave Singelée and Bart Preneel of KU Leuven; Eduard Marin formerly of KU Leuven, currently with University of Birmingham; Flavio D. Garcia; Tom Chothia of the University of Birmingham; and Rik Willems of University Hospital Gasthuisberg Leuven reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:21.992Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "107544",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/107544"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-19-080-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Conexus Radio Frequency Telemetry Protocol",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MyCareLink Monitor",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "24950"
            },
            {
              "status": "affected",
              "version": "24952"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CareLink Monitor",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "2490C"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CareLink 2090 Programmer",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Amplia CRT-D",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Claria CRT-D",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Compia CRT-D",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Concerto CRT-D",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Concerto II CRT-D",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Consulta CRT-D",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Evera ICD",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Maximo II CRT-D",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Maximo II ICD",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Mirro ICD",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Nayamed ND ICD",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Primo ICD",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Protecta ICD, Protecta CRT-D",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Secura ICD",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Virtuoso ICD",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Virtuoso II ICD",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Visia AF ICD",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Viva CRT-D",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Brava CRT-D",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Mirro MRI ICD",
          "vendor": "Medtronic",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Peter Morgan of Clever Security; Dave Singel\u00e9e and Bart Preneel of KU Leuven; Eduard Marin formerly of KU Leuven, currently with University of Birmingham; Flavio D. Garcia; Tom Chothia of the University of Birmingham; and Rik Willems of University Hospital Gasthuisberg Leuven reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2019-03-21T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\nThe Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product\u2019s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.\n\n\u003c/p\u003e"
            }
          ],
          "value": "The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product\u2019s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-22T19:26:15.126Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-19-080-01"
        },
        {
          "name": "107544",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/107544"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMedtronic has developed mitigating patches for a subset of the \naffected implanted cardiac device models. These patches are installed \nduring regular office visits. Medtronic has stated that patches for \nadditional impacted models are being developed by Medtronic and will be \ndeployed through future updates. Patches are currently available for the\n following affected models:\u003cbr\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eProtecta CRT-D and implantable cardioverter defibrillators (ICDs), all models\u003c/li\u003e\u003c/ul\u003e\u003cul\u003e\u003cli\u003eAmplia MRI CRT-D, all models (patch available in U.S. only)\u003c/li\u003e\u003cli\u003eClaria MRI CRT-D, all models (patch available in U.S. only)\u003c/li\u003e\u003cli\u003eCompia MRI CRT-D, all models (patch available in U.S. only)\u003c/li\u003e\u003cli\u003eVisia AF MRI ICD, all models\u003c/li\u003e\u003cli\u003eVisia AF ICD, all models \u003c/li\u003e\u003cli\u003eBrava CRT-D, all models \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\u003c/li\u003e\u003cli\u003eEvera MRI ICD, all models\u003c/li\u003e\u003cli\u003eEvera ICD, all models\u003c/li\u003e\u003cli\u003eMirro MRI ICD, all models\u003c/li\u003e\u003cli\u003ePrimo MRI ICD, all models\u003c/li\u003e\u003cli\u003eViva CRT-D, all models\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Medtronic has developed mitigating patches for a subset of the \naffected implanted cardiac device models. These patches are installed \nduring regular office visits. Medtronic has stated that patches for \nadditional impacted models are being developed by Medtronic and will be \ndeployed through future updates. Patches are currently available for the\n following affected models:\n\n\n  *  Protecta CRT-D and implantable cardioverter defibrillators (ICDs), all models\n\n\n  *  Amplia MRI CRT-D, all models (patch available in U.S. only)\n  *  Claria MRI CRT-D, all models (patch available in U.S. only)\n  *  Compia MRI CRT-D, all models (patch available in U.S. only)\n  *  Visia AF MRI ICD, all models\n  *  Visia AF ICD, all models \n  *  Brava CRT-D, all models \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\n  *  Evera MRI ICD, all models\n  *  Evera ICD, all models\n  *  Mirro MRI ICD, all models\n  *  Primo MRI ICD, all models\n  *  Viva CRT-D, all models"
        }
      ],
      "source": {
        "advisory": "ICSMA-19-080-01",
        "discovery": "EXTERNAL"
      },
      "title": "Medtronic Conexus Radio Frequency Telemetry Protocol Improper Access Control",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMedtronic has applied additional controls for monitoring and responding to improper use of the Conexus telemetry protocol by the affected implanted cardiac devices. Additional mitigations are being developed and will be deployed through future updates, assuming regulatory approval.\u003c/p\u003e\u003cp\u003eMedtronic recommends that users take additional defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\u003c/p\u003e\u003cul\u003e\u003cli\u003eMaintain good physical control over home monitors and programmers.\u003c/li\u003e\u003cli\u003eUse only home monitors, programmers, and implantable devices obtained directly from your healthcare provider or a Medtronic representative to ensure integrity of the system.\u003c/li\u003e\u003cli\u003eDo not connect unapproved devices to home monitors and programmers through USB ports or other physical connections.\u003c/li\u003e\u003cli\u003eOnly use programmers to connect and interact with implanted devices in physically controlled hospital and clinical environments.\u003c/li\u003e\u003cli\u003eOnly use home monitors in private environments such as a home, apartment, or otherwise physically controlled environment.\u003c/li\u003e\u003cli\u003eReport any concerning behavior regarding these products to your healthcare provider or a Medtronic representative.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eMedtronic has released additional \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.medtronic.com/security\"\u003epatient focused information\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Medtronic has applied additional controls for monitoring and responding to improper use of the Conexus telemetry protocol by the affected implanted cardiac devices. Additional mitigations are being developed and will be deployed through future updates, assuming regulatory approval.\n\nMedtronic recommends that users take additional defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\n\n  *  Maintain good physical control over home monitors and programmers.\n  *  Use only home monitors, programmers, and implantable devices obtained directly from your healthcare provider or a Medtronic representative to ensure integrity of the system.\n  *  Do not connect unapproved devices to home monitors and programmers through USB ports or other physical connections.\n  *  Only use programmers to connect and interact with implanted devices in physically controlled hospital and clinical environments.\n  *  Only use home monitors in private environments such as a home, apartment, or otherwise physically controlled environment.\n  *  Report any concerning behavior regarding these products to your healthcare provider or a Medtronic representative.\n\n\nMedtronic has released additional  patient focused information https://www.medtronic.com/security ."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2019-6540",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Conexus Radio Frequency Telemetry Protocol",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "MyCareLink Monitor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "24950"
                          },
                          {
                            "version_value": "24952"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CareLink Monitor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2490C"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "CareLink 2090 Programmer",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Amplia CRT-D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Claria CRT-D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Compia CRT-D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Concerto CRT-D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Concerto II CRT-D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Consulta CRT-D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Evera ICD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Maximo II CRT-D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Maximo II ICD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Mirro ICD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Nayamed ND ICD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Primo ICD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Protecta ICD, Protecta CRT-D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Secura ICD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Virtuoso ICD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Virtuoso II ICD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Visia AF ICD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Viva CRT-D",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Medtronic"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cleartext transmission of sensitive information CWE-319"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-19-080-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-19-080-01"
            },
            {
              "name": "107544",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/107544"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-6538",
    "datePublished": "2019-03-25T21:26:03.000Z",
    "dateReserved": "2019-01-22T00:00:00.000Z",
    "dateUpdated": "2025-05-22T19:26:15.126Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation ID: MIT-1

Phases: Architecture and Design, Operation

Description:

  • Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.
Mitigation ID: MIT-46

Phase: Architecture and Design

Strategy: Separation of Privilege

Description:

  • Compartmentalize the system to have "safe" areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area.
  • Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.
CAPEC-19: Embedding Scripts within Scripts

An adversary leverages the capability to execute their own script by embedding it within other scripts that the target software is likely to execute due to programs' vulnerabilities that are brought on by allowing remote hosts to execute scripts.

CAPEC-441: Malicious Logic Insertion

An adversary installs or adds malicious logic (also known as malware) into a seemingly benign component of a fielded system. This logic is often hidden from the user of the system and works behind the scenes to achieve negative impacts. With the proliferation of mass digital storage and inexpensive multimedia devices, Bluetooth and 802.11 support, new attack vectors for spreading malware are emerging for things we once thought of as innocuous greeting cards, picture frames, or digital projectors. This pattern of attack focuses on systems already fielded and used in operation as opposed to systems and their components that are still under development and part of the supply chain.

CAPEC-478: Modification of Windows Service Configuration

An adversary exploits a weakness in access control to modify the execution parameters of a Windows service. The goal of this attack is to execute a malicious binary in place of an existing service.

CAPEC-479: Malicious Root Certificate

An adversary exploits a weakness in authorization and installs a new root certificate on a compromised system. Certificates are commonly used for establishing secure TLS/SSL communications within a web browser. When a user attempts to browse a website that presents a certificate that is not trusted an error message will be displayed to warn the user of the security risk. Depending on the security settings, the browser may not allow the user to establish a connection to the website. Adversaries have used this technique to avoid security warnings prompting users when compromised systems connect over HTTPS to adversary controlled web servers that spoof legitimate websites in order to collect login credentials.

CAPEC-502: Intent Spoof

An adversary, through a previously installed malicious application, issues an intent directed toward a specific trusted application's component in an attempt to achieve a variety of different objectives including modification of data, information disclosure, and data injection. Components that have been unintentionally exported and made public are subject to this type of an attack. If the component trusts the intent's action without verififcation, then the target application performs the functionality at the adversary's request, helping the adversary achieve the desired negative technical impact.

CAPEC-503: WebView Exposure

An adversary, through a malicious web page, accesses application specific functionality by leveraging interfaces registered through WebView's addJavascriptInterface API. Once an interface is registered to WebView through addJavascriptInterface, it becomes global and all pages loaded in the WebView can call this interface.

CAPEC-536: Data Injected During Configuration

An attacker with access to data files and processes on a victim's system injects malicious data into critical operational data during configuration or recalibration, causing the victim's system to perform in a suboptimal manner that benefits the adversary.

CAPEC-546: Incomplete Data Deletion in a Multi-Tenant Environment

An adversary obtains unauthorized information due to insecure or incomplete data deletion in a multi-tenant environment. If a cloud provider fails to completely delete storage and data from former cloud tenants' systems/resources, once these resources are allocated to new, potentially malicious tenants, the latter can probe the provided resources for sensitive information still there.

CAPEC-550: Install New Service

When an operating system starts, it also starts programs called services or daemons. Adversaries may install a new service which will be executed at startup (on a Windows system, by modifying the registry). The service name may be disguised by using a name from a related operating system or benign software. Services are usually run with elevated privileges.

CAPEC-551: Modify Existing Service

When an operating system starts, it also starts programs called services or daemons. Modifying existing services may break existing services or may enable services that are disabled/not commonly used.

CAPEC-552: Install Rootkit

An adversary exploits a weakness in authentication to install malware that alters the functionality and information provide by targeted operating system API calls. Often referred to as rootkits, it is often used to hide the presence of programs, files, network connections, services, drivers, and other system components.

CAPEC-556: Replace File Extension Handlers

When a file is opened, its file handler is checked to determine which program opens the file. File handlers are configuration properties of many operating systems. Applications can modify the file handler for a given file extension to call an arbitrary program when a file with the given extension is opened.

CAPEC-558: Replace Trusted Executable

An adversary exploits weaknesses in privilege management or access control to replace a trusted executable with a malicious version and enable the execution of malware when that trusted executable is called.

CAPEC-562: Modify Shared File

An adversary manipulates the files in a shared location by adding malicious programs, scripts, or exploit code to valid content. Once a user opens the shared content, the tainted content is executed.

CAPEC-563: Add Malicious File to Shared Webroot

An adversaries may add malicious content to a website through the open file share and then browse to that content with a web browser to cause the server to execute the content. The malicious content will typically run under the context and permissions of the web server process, often resulting in local system or administrative privileges depending on how the web server is configured.

CAPEC-564: Run Software at Logon

Operating system allows logon scripts to be run whenever a specific user or users logon to a system. If adversaries can access these scripts, they may insert additional code into the logon script. This code can allow them to maintain persistence or move laterally within an enclave because it is executed every time the affected user or users logon to a computer. Modifying logon scripts can effectively bypass workstation and enclave firewalls. Depending on the access configuration of the logon scripts, either local credentials or a remote administrative account may be necessary.

CAPEC-578: Disable Security Software

An adversary exploits a weakness in access control to disable security tools so that detection does not occur. This can take the form of killing processes, deleting registry keys so that tools do not start at run time, deleting log files, or other methods.

Back to CWE stats page