Common Weakness Enumeration

CWE-77

Allowed-with-Review

Improper Neutralization of Special Elements used in a Command ('Command Injection')

Abstraction: Class · Status: Draft

The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.

5383 vulnerabilities reference this CWE, most recent first.

CVE-2024-7436 (GCVE-0-2024-7436)

Vulnerability from cvelistv5 – Published: 2024-08-03 14:00 – Updated: 2024-08-07 16:07
VLAI
Title
D-Link DI-8100 msp_info.htm msp_info_htm command injection
Summary
A vulnerability, which was classified as critical, has been found in D-Link DI-8100 16.07. This issue affects the function msp_info_htm of the file msp_info.htm. The manipulation of the argument cmd leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-273521 was assigned to this vulnerability.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.273521 vdb-entrytechnical-description
https://vuldb.com/?ctiid.273521 signaturepermissions-required
https://vuldb.com/?submit.370591 third-party-advisory
https://github.com/aLtEr6/pdf/blob/main/2.pdf exploit
Impacted products
Vendor Product Version
D-Link DI-8100 Affected: 16.07
Create a notification for this product.
d-link di-8100 Affected: 16.07
    cpe:2.3:h:d-link:di-8100:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
aLtEr (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:d-link:di-8100:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "di-8100",
            "vendor": "d-link",
            "versions": [
              {
                "status": "affected",
                "version": "16.07"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7436",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-07T16:06:22.421863Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-07T16:07:37.883Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DI-8100",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "16.07"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "aLtEr (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in D-Link DI-8100 16.07. This issue affects the function msp_info_htm of the file msp_info.htm. The manipulation of the argument cmd leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-273521 was assigned to this vulnerability."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in D-Link DI-8100 16.07 entdeckt. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion msp_info_htm der Datei msp_info.htm. Mittels Manipulieren des Arguments cmd mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-03T14:00:08.723Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-273521 | D-Link DI-8100 msp_info.htm msp_info_htm command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.273521"
        },
        {
          "name": "VDB-273521 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.273521"
        },
        {
          "name": "Submit #370591 | D-Link NetworkManager D-LINK DI-8100 16.07 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.370591"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/aLtEr6/pdf/blob/main/2.pdf"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-08-02T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-08-02T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-08-02T23:16:41.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "D-Link DI-8100 msp_info.htm msp_info_htm command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7436",
    "datePublished": "2024-08-03T14:00:08.723Z",
    "dateReserved": "2024-08-02T21:11:25.416Z",
    "dateUpdated": "2024-08-07T16:07:37.883Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-7397 (GCVE-0-2024-7397)

Vulnerability from cvelistv5 – Published: 2024-08-05 13:25 – Updated: 2025-11-04 16:15
VLAI
Title
Unauthenticated Command Injection
Summary
Improper filering of special characters result in a command ('command injection') vulnerability in Korenix JetPort 5601v3.This issue affects JetPort 5601v3: through 1.2.
SSVC
Exploitation: poc Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
Impacted products
Vendor Product Version
Korenix JetPort 5601v3 Affected: 0 , ≤ 1.2 (custom)
Create a notification for this product.
korenix jetport5601v3 Affected: 0 , ≤ 1.2 (custom)
    cpe:2.3:a:korenix:jetport5601v3:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
S. Dietz (CyberDanube)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:korenix:jetport5601v3:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "jetport5601v3",
            "vendor": "korenix",
            "versions": [
              {
                "lessThanOrEqual": "1.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7397",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-05T14:15:49.858700Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:26:13.585Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-04T16:15:55.337Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2024/Aug/2"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "JetPort 5601v3",
          "vendor": "Korenix",
          "versions": [
            {
              "lessThanOrEqual": "1.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "S. Dietz (CyberDanube)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper filering of special characters result in a command (\u0027command injection\u0027) vulnerability in Korenix JetPort 5601v3.\u003cp\u003eThis issue affects JetPort 5601v3: through 1.2.\u003c/p\u003e"
            }
          ],
          "value": "Improper filering of special characters result in a command (\u0027command injection\u0027) vulnerability in Korenix JetPort 5601v3.This issue affects JetPort 5601v3: through 1.2."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-88",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-88 OS Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-05T13:25:43.610Z",
        "orgId": "7d092a75-6bbd-48c6-a15a-0297458009bc",
        "shortName": "CyberDanube"
      },
      "references": [
        {
          "url": "https://cyberdanube.com/de/en-multiple-vulnerabilities-in-korenix-jetport/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Unauthenticated Command Injection",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d092a75-6bbd-48c6-a15a-0297458009bc",
    "assignerShortName": "CyberDanube",
    "cveId": "CVE-2024-7397",
    "datePublished": "2024-08-05T13:25:43.610Z",
    "dateReserved": "2024-08-01T21:46:36.711Z",
    "dateUpdated": "2025-11-04T16:15:55.337Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2024-7215 (GCVE-0-2024-7215)

Vulnerability from cvelistv5 – Published: 2024-07-30 03:31 – Updated: 2024-08-01 21:52
VLAI
Title
TOTOLINK LR1200 cstecgi.cgi NTPSyncWithHost command injection
Summary
A vulnerability was found in TOTOLINK LR1200 9.3.1cu.2832 and classified as critical. Affected by this issue is the function NTPSyncWithHost of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument host_time leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-272786 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.272786 vdb-entrytechnical-description
https://vuldb.com/?ctiid.272786 signaturepermissions-required
https://vuldb.com/?submit.378330 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
TOTOLINK LR1200 Affected: 9.3.1cu.2832
Create a notification for this product.
totolink lr1200_firmware Affected: 9.3.1cu.2832
    cpe:2.3:o:totolink:lr1200_firmware:9.3.1cu.2832:*:*:*:*:*:*:*
Create a notification for this product.
Credits
yhryhryhr_miemie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:totolink:lr1200_firmware:9.3.1cu.2832:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "lr1200_firmware",
            "vendor": "totolink",
            "versions": [
              {
                "status": "affected",
                "version": "9.3.1cu.2832"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7215",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-30T18:46:32.788829Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-30T18:49:27.559Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:52:31.460Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-272786 | TOTOLINK LR1200 cstecgi.cgi NTPSyncWithHost command injection",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.272786"
          },
          {
            "name": "VDB-272786 | CTI Indicators (IOB, IOC, TTP, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.272786"
          },
          {
            "name": "Submit #378330 | TOTOLINK LR1200 V9.3.1cu.2832 Command Injection",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.378330"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/LR1200/NTPSyncWithHost.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LR1200",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "9.3.1cu.2832"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in TOTOLINK LR1200 9.3.1cu.2832 and classified as critical. Affected by this issue is the function NTPSyncWithHost of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument host_time leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-272786 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in TOTOLINK LR1200 9.3.1cu.2832 gefunden. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion NTPSyncWithHost der Datei /cgi-bin/cstecgi.cgi. Durch Manipulieren des Arguments host_time mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-30T03:31:03.942Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-272786 | TOTOLINK LR1200 cstecgi.cgi NTPSyncWithHost command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.272786"
        },
        {
          "name": "VDB-272786 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.272786"
        },
        {
          "name": "Submit #378330 | TOTOLINK LR1200 V9.3.1cu.2832 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.378330"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/LR1200/NTPSyncWithHost.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-07-29T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-07-29T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-07-29T20:22:59.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK LR1200 cstecgi.cgi NTPSyncWithHost command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7215",
    "datePublished": "2024-07-30T03:31:03.942Z",
    "dateReserved": "2024-07-29T18:17:43.039Z",
    "dateUpdated": "2024-08-01T21:52:31.460Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-7214 (GCVE-0-2024-7214)

Vulnerability from cvelistv5 – Published: 2024-07-30 03:00 – Updated: 2024-08-01 21:52
VLAI
Title
TOTOLINK LR350 cstecgi.cgi setWanCfg command injection
Summary
A vulnerability has been found in TOTOLINK LR350 9.3.5u.6369_B20220309 and classified as critical. Affected by this vulnerability is the function setWanCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument hostName leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272785 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.272785 vdb-entrytechnical-description
https://vuldb.com/?ctiid.272785 signaturepermissions-required
https://vuldb.com/?submit.378319 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
TOTOLINK LR350 Affected: 9.3.5u.6369_B20220309
Create a notification for this product.
totolink lr350 Affected: 9.3.5u.6369_b20220309
    cpe:2.3:h:totolink:lr350:9.3.5u.6369_b20220309:*:*:*:*:*:*:*
Create a notification for this product.
Credits
yhryhryhr_miemie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:totolink:lr350:9.3.5u.6369_b20220309:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "lr350",
            "vendor": "totolink",
            "versions": [
              {
                "status": "affected",
                "version": "9.3.5u.6369_b20220309"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7214",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-30T14:37:05.291303Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-31T17:35:01.503Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:52:31.506Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-272785 | TOTOLINK LR350 cstecgi.cgi setWanCfg command injection",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.272785"
          },
          {
            "name": "VDB-272785 | CTI Indicators (IOB, IOC, TTP, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.272785"
          },
          {
            "name": "Submit #378319 | TOTOLINK LR350 V9.3.5u.6369_B20220309 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.378319"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/LR350/setWanCfg.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LR350",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "9.3.5u.6369_B20220309"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_miemie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in TOTOLINK LR350 9.3.5u.6369_B20220309 and classified as critical. Affected by this vulnerability is the function setWanCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument hostName leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272785 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In TOTOLINK LR350 9.3.5u.6369_B20220309 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Es geht um die Funktion setWanCfg der Datei /cgi-bin/cstecgi.cgi. Durch das Manipulieren des Arguments hostName mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-30T03:00:08.298Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-272785 | TOTOLINK LR350 cstecgi.cgi setWanCfg command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.272785"
        },
        {
          "name": "VDB-272785 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.272785"
        },
        {
          "name": "Submit #378319 | TOTOLINK LR350 V9.3.5u.6369_B20220309 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.378319"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/LR350/setWanCfg.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-07-29T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-07-29T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-07-29T20:22:57.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK LR350 cstecgi.cgi setWanCfg command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7214",
    "datePublished": "2024-07-30T03:00:08.298Z",
    "dateReserved": "2024-07-29T18:17:40.060Z",
    "dateUpdated": "2024-08-01T21:52:31.506Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-7181 (GCVE-0-2024-7181)

Vulnerability from cvelistv5 – Published: 2024-07-29 03:31 – Updated: 2024-08-01 21:52
VLAI
Title
TOTOLINK A3600R cstecgi.cgi setTelnetCfg command injection
Summary
A vulnerability classified as critical was found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. This vulnerability affects the function setTelnetCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument telnet_enabled leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-272602 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.272602 vdb-entrytechnical-description
https://vuldb.com/?ctiid.272602 signaturepermissions-required
https://vuldb.com/?submit.378050 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
TOTOLINK A3600R Affected: 4.1.2cu.5182_B20201102
Create a notification for this product.
totolink a3600r_firmware Affected: 4.1.2cu.5182_b20201102
    cpe:2.3:o:totolink:a3600r_firmware:4.1.2cu.5182_b20201102:*:*:*:*:*:*:*
Create a notification for this product.
Credits
wxhwxhwxh_tutu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:totolink:a3600r_firmware:4.1.2cu.5182_b20201102:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "a3600r_firmware",
            "vendor": "totolink",
            "versions": [
              {
                "status": "affected",
                "version": "4.1.2cu.5182_b20201102"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7181",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-29T13:26:49.861827Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-29T13:27:22.498Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:52:30.842Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-272602 | TOTOLINK A3600R cstecgi.cgi setTelnetCfg command injection",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.272602"
          },
          {
            "name": "VDB-272602 | CTI Indicators (IOB, IOC, TTP, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.272602"
          },
          {
            "name": "Submit #378050 | TOTOLINK A3600R V4.1.2cu.5182_B20201102 Command Injection",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.378050"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3600R/setTelnetCfg.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "A3600R",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.2cu.5182_B20201102"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_tutu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. This vulnerability affects the function setTelnetCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument telnet_enabled leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-272602 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In TOTOLINK A3600R 4.1.2cu.5182_B20201102 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Betroffen ist die Funktion setTelnetCfg der Datei /cgi-bin/cstecgi.cgi. Dank der Manipulation des Arguments telnet_enabled mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-29T03:31:04.422Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-272602 | TOTOLINK A3600R cstecgi.cgi setTelnetCfg command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.272602"
        },
        {
          "name": "VDB-272602 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.272602"
        },
        {
          "name": "Submit #378050 | TOTOLINK A3600R V4.1.2cu.5182_B20201102 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.378050"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3600R/setTelnetCfg.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-07-28T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-07-28T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-07-28T07:40:23.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK A3600R cstecgi.cgi setTelnetCfg command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7181",
    "datePublished": "2024-07-29T03:31:04.422Z",
    "dateReserved": "2024-07-28T05:35:17.289Z",
    "dateUpdated": "2024-08-01T21:52:30.842Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-7160 (GCVE-0-2024-7160)

Vulnerability from cvelistv5 – Published: 2024-07-28 15:00 – Updated: 2024-08-01 21:52
VLAI
Title
TOTOLINK A3700R cstecgi.cgi setWanCfg command injection
Summary
A vulnerability classified as critical has been found in TOTOLINK A3700R 9.1.2u.5822_B20200513. Affected is the function setWanCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument hostName leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-272574 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.272574 vdb-entrytechnical-description
https://vuldb.com/?ctiid.272574 signaturepermissions-required
https://vuldb.com/?submit.377080 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
TOTOLINK A3700R Affected: 9.1.2u.5822_B20200513
Create a notification for this product.
totolink a3700r_firmware Affected: 9.1.2u.5822_b20200513
    cpe:2.3:o:totolink:a3700r_firmware:9.1.2u.5822_b20200513:*:*:*:*:*:*:*
Create a notification for this product.
Credits
yhryhryhr_tu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:totolink:a3700r_firmware:9.1.2u.5822_b20200513:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "a3700r_firmware",
            "vendor": "totolink",
            "versions": [
              {
                "status": "affected",
                "version": "9.1.2u.5822_b20200513"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7160",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-29T13:29:48.121455Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-29T13:30:39.583Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:52:30.737Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-272574 | TOTOLINK A3700R cstecgi.cgi setWanCfg command injection",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.272574"
          },
          {
            "name": "VDB-272574 | CTI Indicators (IOB, IOC, TTP, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.272574"
          },
          {
            "name": "Submit #377080 | TOTOLINK A3700R V9.1.2u.5822_B20200513 Command Injection",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.377080"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3700R/setWanCfg.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "A3700R",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "9.1.2u.5822_B20200513"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_tu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in TOTOLINK A3700R 9.1.2u.5822_B20200513. Affected is the function setWanCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument hostName leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-272574 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in TOTOLINK A3700R 9.1.2u.5822_B20200513 entdeckt. Betroffen hiervon ist die Funktion setWanCfg der Datei /cgi-bin/cstecgi.cgi. Mittels dem Manipulieren des Arguments hostName mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-28T15:00:07.203Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-272574 | TOTOLINK A3700R cstecgi.cgi setWanCfg command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.272574"
        },
        {
          "name": "VDB-272574 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.272574"
        },
        {
          "name": "Submit #377080 | TOTOLINK A3700R V9.1.2u.5822_B20200513 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.377080"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3700R/setWanCfg.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-07-27T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-07-27T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-07-27T20:50:37.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK A3700R cstecgi.cgi setWanCfg command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7160",
    "datePublished": "2024-07-28T15:00:07.203Z",
    "dateReserved": "2024-07-27T18:43:00.373Z",
    "dateUpdated": "2024-08-01T21:52:30.737Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-7158 (GCVE-0-2024-7158)

Vulnerability from cvelistv5 – Published: 2024-07-28 13:31 – Updated: 2024-08-01 21:52
VLAI
Title
TOTOLINK A3100R HTTP POST Request cstecgi.cgi setTelnetCfg command injection
Summary
A vulnerability was found in TOTOLINK A3100R 4.1.2cu.5050_B20200504. It has been declared as critical. This vulnerability affects the function setTelnetCfg of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument telnet_enabled leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272572. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
URL Tags
https://vuldb.com/?id.272572 vdb-entrytechnical-description
https://vuldb.com/?ctiid.272572 signaturepermissions-required
https://vuldb.com/?submit.377543 third-party-advisory
https://github.com/abcdefg-png/IoT-vulnerable/blo… exploit
Impacted products
Vendor Product Version
TOTOLINK A3100R Affected: 4.1.2cu.5050_B20200504
Create a notification for this product.
totolink a3100r Affected: 4.1.2cu.5050
    cpe:2.3:h:totolink:a3100r:-:*:*:*:*:*:*:*
Create a notification for this product.
Credits
yhryhryhr_tu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:totolink:a3100r:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "a3100r",
            "vendor": "totolink",
            "versions": [
              {
                "status": "affected",
                "version": "4.1.2cu.5050"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7158",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-29T17:25:16.094997Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-29T17:27:15.923Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:52:30.601Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-272572 | TOTOLINK A3100R HTTP POST Request cstecgi.cgi setTelnetCfg command injection",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.272572"
          },
          {
            "name": "VDB-272572 | CTI Indicators (IOB, IOC, TTP, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.272572"
          },
          {
            "name": "Submit #377543 | TOTOLINK A3100R V4.1.2cu.5050_B20200504 Command Injection",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.377543"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3100R/setTelnetCfg.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "HTTP POST Request Handler"
          ],
          "product": "A3100R",
          "vendor": "TOTOLINK",
          "versions": [
            {
              "status": "affected",
              "version": "4.1.2cu.5050_B20200504"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "yhryhryhr_tu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in TOTOLINK A3100R 4.1.2cu.5050_B20200504. It has been declared as critical. This vulnerability affects the function setTelnetCfg of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument telnet_enabled leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272572. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "In TOTOLINK A3100R 4.1.2cu.5050_B20200504 wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Betroffen ist die Funktion setTelnetCfg der Datei /cgi-bin/cstecgi.cgi der Komponente HTTP POST Request Handler. Durch die Manipulation des Arguments telnet_enabled mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-28T13:31:03.637Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-272572 | TOTOLINK A3100R HTTP POST Request cstecgi.cgi setTelnetCfg command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.272572"
        },
        {
          "name": "VDB-272572 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.272572"
        },
        {
          "name": "Submit #377543 | TOTOLINK A3100R V4.1.2cu.5050_B20200504 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.377543"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/TOTOLINK/A3100R/setTelnetCfg.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-07-27T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-07-27T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-07-27T19:32:42.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "TOTOLINK A3100R HTTP POST Request cstecgi.cgi setTelnetCfg command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-7158",
    "datePublished": "2024-07-28T13:31:03.637Z",
    "dateReserved": "2024-07-27T17:27:25.551Z",
    "dateUpdated": "2024-08-01T21:52:30.601Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-7110 (GCVE-0-2024-7110)

Vulnerability from cvelistv5 – Published: 2024-08-22 15:30 – Updated: 2024-09-17 15:35
VLAI
Title
Improper Neutralization of Special Elements used in a Command ('Command Injection') in GitLab
Summary
An issue was discovered in GitLab EE affecting all versions starting 17.0 to 17.1.6, 17.2 prior to 17.2.4, and 17.3 prior to 17.3.1 allows an attacker to execute arbitrary command in a victim's pipeline through prompt injection.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
URL Tags
https://gitlab.com/gitlab-org/gitlab/-/issues/472603 issue-trackingpermissions-required
Impacted products
Vendor Product Version
GitLab GitLab Affected: 17.1 , < 17.1.6 (semver)
Affected: 17.2 , < 17.2.4 (semver)
Affected: 17.3 , < 17.3.1 (semver)
    cpe:2.3:a:gitlab:gitlab:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
This vulnerability has been discovered internally by GitLab team member [Dennis Appelt](hhttps://gitlab.com/dappelt).
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7110",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-22T17:32:38.600598Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-17T15:35:37.142Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:a:gitlab:gitlab:*:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "GitLab",
          "repo": "git://git@gitlab.com:gitlab-org/gitlab.git",
          "vendor": "GitLab",
          "versions": [
            {
              "lessThan": "17.1.6",
              "status": "affected",
              "version": "17.1",
              "versionType": "semver"
            },
            {
              "lessThan": "17.2.4",
              "status": "affected",
              "version": "17.2",
              "versionType": "semver"
            },
            {
              "lessThan": "17.3.1",
              "status": "affected",
              "version": "17.3",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This vulnerability has been discovered internally by GitLab team member [Dennis Appelt](hhttps://gitlab.com/dappelt)."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in GitLab EE affecting all versions starting 17.0 to 17.1.6, 17.2 prior to 17.2.4, and 17.3 prior to 17.3.1 allows an attacker to execute arbitrary command in a victim\u0027s pipeline through prompt injection."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-29T15:05:01.045Z",
        "orgId": "ceab7361-8a18-47b1-92ba-4d7d25f6715a",
        "shortName": "GitLab"
      },
      "references": [
        {
          "name": "GitLab Issue #472603",
          "tags": [
            "issue-tracking",
            "permissions-required"
          ],
          "url": "https://gitlab.com/gitlab-org/gitlab/-/issues/472603"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Upgrade to versions 17.3.1, 17.2.4, 17.1.6 or above."
        }
      ],
      "title": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) in GitLab"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ceab7361-8a18-47b1-92ba-4d7d25f6715a",
    "assignerShortName": "GitLab",
    "cveId": "CVE-2024-7110",
    "datePublished": "2024-08-22T15:30:47.474Z",
    "dateReserved": "2024-07-25T13:30:43.896Z",
    "dateUpdated": "2024-09-17T15:35:37.142Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-7029 (GCVE-0-2024-7029)

Vulnerability from cvelistv5 – Published: 2024-08-02 15:08 – Updated: 2025-01-09 19:22
VLAI
Title
Command Injection in AVTech AVM1203 (IP Camera)
Summary
Commands can be injected over the network and executed without authentication.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
Impacted products
Vendor Product Version
AVTech AVM1203 (IP Camera) Affected: 0 , ≤ FullImg-1023-1007-1011-1009 (custom)
Create a notification for this product.
avtec avm1203\/ipcamera\/ Affected: 0 , ≤ fullImg-1023-1007-1011-1009 (custom)
    cpe:2.3:a:avtec:avm1203\/ipcamera\/:*:*:*:*:*:*:*:*
Create a notification for this product.
Credits
Larry Cashdollar and Aline Eliovich of Akamai Technologies reported this vulnerability to CISA. An anonymous third-party organization confirmed Akamai's report and identified specific affected products and firmware versions.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:avtec:avm1203\\/ipcamera\\/:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "avm1203\\/ipcamera\\/",
            "vendor": "avtec",
            "versions": [
              {
                "lessThanOrEqual": "fullImg-1023-1007-1011-1009",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7029",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-05T15:18:01.228848Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-09T19:22:30.663Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "AVM1203 (IP Camera)",
          "vendor": "AVTech",
          "versions": [
            {
              "lessThanOrEqual": "FullImg-1023-1007-1011-1009",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Larry Cashdollar and Aline Eliovich of Akamai Technologies reported this vulnerability to CISA."
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "An anonymous third-party organization confirmed Akamai\u0027s report and identified specific affected products and firmware versions."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCommands can be injected over the network and executed without authentication.\u003c/span\u003e"
            }
          ],
          "value": "Commands can be injected over the network and executed without authentication."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-25T22:56:58.061Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-214-07"
        },
        {
          "url": "https://www.akamai.com/blog/security-research/2024-corona-mirai-botnet-infects-zero-day-sirt"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAVTECH SECURITY Corporation has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of the affected products are encouraged to contact \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.avtech.com.tw/ContactUs.aspx\"\u003eAVTECH\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;for additional information.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "AVTECH SECURITY Corporation has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of the affected products are encouraged to contact  AVTECH https://www.avtech.com.tw/ContactUs.aspx \u00a0for additional information."
        }
      ],
      "source": {
        "advisory": "ICSA-24-214-07",
        "discovery": "EXTERNAL"
      },
      "title": "Command Injection in AVTech AVM1203 (IP Camera)",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2024-7029",
    "datePublished": "2024-08-02T15:08:35.991Z",
    "dateReserved": "2024-07-23T16:19:10.205Z",
    "dateUpdated": "2025-01-09T19:22:30.663Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-6333 (GCVE-0-2024-6333)

Vulnerability from cvelistv5 – Published: 2024-10-17 13:51 – Updated: 2025-09-17 16:52
VLAI
Title
Authenticated Remote Code Execution in Altalink, Versalink & WorkCentre Products
Summary
Authenticated Remote Code Execution in Altalink, Versalink & WorkCentre Products.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
Impacted products
Vendor Product Version
Xerox AltaLink® B8045 / B8055 / B8065 / B8075 / B8090 | C8030 / C8035 / C8045 / C8055 / C807 Affected: 103.xxx.024.18600 (custom)
Create a notification for this product.
Xerox Xerox® EC8036 / EC8056 Affected: 103.xxx.024.18600
Create a notification for this product.
Xerox Xerox® EC8036 / EC8056 - Common Criteria (June 2022) Affected: 103.023.031.35105
Create a notification for this product.
Xerox Xerox® EC8036 / EC8056 - Common Criteria (June 2024) Affected: 103.xxx.013.14115
Create a notification for this product.
Xerox AltaLink®C8130 / C8135 / C8145 / C8155 / C8170 | B8145 / B8155 / B8170 Common Criteria (Aug 2024) Affected: 119.xxx.023.13006
Create a notification for this product.
Xerox AltaLink® C8130 / C8135 / C8145 / C8155 / C8170 | B8145 / B8155 / B8170 Common Criteria Certified (Aug 2023) Affected: 111.xxx.003.11600
Create a notification for this product.
Xerox VersaLink® B625 / C625 | B425 / C425 Common Criteria Certified (2024) Affected: 119.xxx.003.11705
Create a notification for this product.
Xerox WorkCentre 3655/3655i Affected: 075.060.004.07810
Create a notification for this product.
Xerox WorkCentre 5945/55i Affected: 075.091.004.07810
Create a notification for this product.
Xerox WorkCentre 6655/6655i Affected: 075.110.004.07810
Create a notification for this product.
Xerox WorkCentre 7220/7225i Affected: 075.030.004.07810
Create a notification for this product.
Xerox WorkCentre 7830/7835i Affected: 075.010 004.07810
Create a notification for this product.
Xerox WorkCentre 7845/7855i Affected: 075.040.004.07810
Create a notification for this product.
Xerox WorkCentre 7845/7855 (IBG) Affected: 075.080.004.07810
Create a notification for this product.
Xerox WorkCentre 7970/7970i Affected: 075.200.004.07810
Create a notification for this product.
Xerox WorkCentre EC7836 Affected: 075.050.004.07810
Create a notification for this product.
Xerox WorkCentre EC7856 Affected: 075.020.004.07810
Create a notification for this product.
xerox altalink_firmware Affected: 0 , < 103.xxx.024.18600 (custom)
Affected: 0 , < 119.xxx.023.13006 (custom)
Affected: 0 , < 111.xxx.003.11600 (custom)
    cpe:2.3:o:xerox:altalink_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
xerox versalink_firmware Affected: 0 , < 119.xxx.003.11705 (custom)
    cpe:2.3:o:xerox:versalink_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
xerox workcentre_firmware Affected: 0 , < 075.060.004.07810 (custom)
Affected: 0 , < 075.091.004.07810 (custom)
Affected: 0 , < 075.110.004.07810 (custom)
Affected: 0 , < 075.030.004.07810 (custom)
Affected: 0 , < 075.010 004.07810 (custom)
Affected: 0 , < 075.040.004.07810 (custom)
Affected: 0 , < 075.080.004.07810 (custom)
Affected: 0 , < 075.200.004.07810 (custom)
Affected: 0 , < 075.050.004.07810 (custom)
Affected: 0 , < 075.020.004.07810 (custom)
    cpe:2.3:o:xerox:workcentre_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
xerox xerox_firmware Affected: 0 , < 103.xxx.024.18600 (custom)
Affected: 0 , < 103.023.031.35105 (custom)
Affected: 0 , < 103.xxx.013.14115 (custom)
    cpe:2.3:o:xerox:xerox_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-10-16 13:46
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:xerox:altalink_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "altalink_firmware",
            "vendor": "xerox",
            "versions": [
              {
                "lessThan": "103.xxx.024.18600",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "119.xxx.023.13006",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "111.xxx.003.11600",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:xerox:versalink_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "versalink_firmware",
            "vendor": "xerox",
            "versions": [
              {
                "lessThan": "119.xxx.003.11705",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:xerox:workcentre_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "workcentre_firmware",
            "vendor": "xerox",
            "versions": [
              {
                "lessThan": "075.060.004.07810",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "075.091.004.07810",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "075.110.004.07810",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "075.030.004.07810",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "075.010 004.07810",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "075.040.004.07810",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "075.080.004.07810",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "075.200.004.07810",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "075.050.004.07810",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "075.020.004.07810",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:xerox:xerox_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "xerox_firmware",
            "vendor": "xerox",
            "versions": [
              {
                "lessThan": "103.xxx.024.18600",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "103.023.031.35105",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              },
              {
                "lessThan": "103.xxx.013.14115",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-6333",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-25T18:32:51.988456Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-25T19:19:55.218Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-10-29T05:02:50.054Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2024/Oct/17"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "AltaLink\u00ae B8045 / B8055 / B8065 / B8075 / B8090 | C8030 / C8035 / C8045 / C8055 / C807",
          "vendor": "Xerox",
          "versions": [
            {
              "status": "affected",
              "version": "103.xxx.024.18600",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Xerox\u00ae EC8036 / EC8056",
          "vendor": "Xerox",
          "versions": [
            {
              "status": "affected",
              "version": "103.xxx.024.18600"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Xerox\u00ae EC8036 / EC8056 - Common Criteria (June 2022)",
          "vendor": "Xerox",
          "versions": [
            {
              "status": "affected",
              "version": "103.023.031.35105"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Xerox\u00ae EC8036 / EC8056 - Common Criteria (June 2024)",
          "vendor": "Xerox",
          "versions": [
            {
              "status": "affected",
              "version": "103.xxx.013.14115"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AltaLink\u00aeC8130 / C8135 / C8145 / C8155 / C8170 | B8145 / B8155 / B8170 Common Criteria (Aug 2024)",
          "vendor": "Xerox",
          "versions": [
            {
              "status": "affected",
              "version": "119.xxx.023.13006"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AltaLink\u00ae C8130 / C8135 / C8145 / C8155 / C8170 | B8145 / B8155 / B8170 Common Criteria Certified (Aug 2023)",
          "vendor": "Xerox",
          "versions": [
            {
              "status": "affected",
              "version": "111.xxx.003.11600"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VersaLink\u00ae B625 / C625 | B425 / C425 Common Criteria Certified (2024)",
          "vendor": "Xerox",
          "versions": [
            {
              "status": "affected",
              "version": "119.xxx.003.11705"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "WorkCentre 3655/3655i",
          "vendor": "Xerox",
          "versions": [
            {
              "status": "affected",
              "version": "075.060.004.07810"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "WorkCentre 5945/55i",
          "vendor": "Xerox",
          "versions": [
            {
              "status": "affected",
              "version": "075.091.004.07810"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "WorkCentre 6655/6655i",
          "vendor": "Xerox",
          "versions": [
            {
              "status": "affected",
              "version": "075.110.004.07810"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "WorkCentre 7220/7225i",
          "vendor": "Xerox",
          "versions": [
            {
              "status": "affected",
              "version": "075.030.004.07810"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "WorkCentre 7830/7835i",
          "vendor": "Xerox",
          "versions": [
            {
              "status": "affected",
              "version": "075.010 004.07810"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "WorkCentre 7845/7855i",
          "vendor": "Xerox",
          "versions": [
            {
              "status": "affected",
              "version": "075.040.004.07810"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "WorkCentre 7845/7855 (IBG)",
          "vendor": "Xerox",
          "versions": [
            {
              "status": "affected",
              "version": "075.080.004.07810"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "WorkCentre 7970/7970i",
          "vendor": "Xerox",
          "versions": [
            {
              "status": "affected",
              "version": "075.200.004.07810"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "WorkCentre EC7836",
          "vendor": "Xerox",
          "versions": [
            {
              "status": "affected",
              "version": "075.050.004.07810"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "WorkCentre EC7856",
          "vendor": "Xerox",
          "versions": [
            {
              "status": "affected",
              "version": "075.020.004.07810"
            }
          ]
        }
      ],
      "datePublic": "2024-10-16T13:46:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Authenticated Remote Code Execution in Altalink, Versalink \u0026amp; WorkCentre Products."
            }
          ],
          "value": "Authenticated Remote Code Execution in Altalink, Versalink \u0026 WorkCentre Products."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-253",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-253 Remote Code Inclusion"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-17T16:52:52.859Z",
        "orgId": "10b61619-3869-496c-8a1e-f291b0e71e3f",
        "shortName": "Xerox"
      },
      "references": [
        {
          "url": "https://securitydocs.business.xerox.com/wp-content/uploads/2024/10/Xerox-Security-Bulletin-XRX24-015-for-Altalink-Versalink-and-WorkCentre-%E2%80%93-CVE-2024-6333-.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Authenticated Remote Code Execution in Altalink, Versalink \u0026 WorkCentre Products",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "10b61619-3869-496c-8a1e-f291b0e71e3f",
    "assignerShortName": "Xerox",
    "cveId": "CVE-2024-6333",
    "datePublished": "2024-10-17T13:51:16.011Z",
    "dateReserved": "2024-06-25T18:31:05.065Z",
    "dateUpdated": "2025-09-17T16:52:52.859Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation
Architecture and Design

If at all possible, use library calls rather than external processes to recreate the desired functionality.

Mitigation
Implementation

If possible, ensure that all external commands called from the program are statically created.

Mitigation MIT-5
Implementation

Strategy: Input Validation

  • Assume all input is malicious. Use an "accept known good" input validation strategy, i.e., use a list of acceptable inputs that strictly conform to specifications. Reject any input that does not strictly conform to specifications, or transform it into something that does.
  • When performing input validation, consider all potentially relevant properties, including length, type of input, the full range of acceptable values, missing or extra inputs, syntax, consistency across related fields, and conformance to business rules. As an example of business rule logic, "boat" may be syntactically valid because it only contains alphanumeric characters, but it is not valid if the input is only expected to contain colors such as "red" or "blue."
  • Do not rely exclusively on looking for malicious or malformed inputs. This is likely to miss at least one undesirable input, especially if the code's environment changes. This can give attackers enough room to bypass the intended validation. However, denylists can be useful for detecting potential attacks or determining which inputs are so malformed that they should be rejected outright.
Mitigation
Operation

Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.

Mitigation
System Configuration

Assign permissions that prevent the user from accessing/opening privileged files.

CAPEC-136: LDAP Injection

An attacker manipulates or crafts an LDAP query for the purpose of undermining the security of the target. Some applications use user input to create LDAP queries that are processed by an LDAP server. For example, a user might provide their username during authentication and the username might be inserted in an LDAP query during the authentication process. An attacker could use this input to inject additional commands into an LDAP query that could disclose sensitive information. For example, entering a * in the aforementioned query might return information about all users on the system. This attack is very similar to an SQL injection attack in that it manipulates a query to gather additional information or coerce a particular return value.

CAPEC-15: Command Delimiters

An attack of this type exploits a programs' vulnerabilities that allows an attacker's commands to be concatenated onto a legitimate command with the intent of targeting other resources such as the file system or database. The system that uses a filter or denylist input validation, as opposed to allowlist validation is vulnerable to an attacker who predicts delimiters (or combinations of delimiters) not present in the filter or denylist. As with other injection attacks, the attacker uses the command delimiter payload as an entry point to tunnel through the application and activate additional attacks through SQL queries, shell commands, network scanning, and so on.

CAPEC-183: IMAP/SMTP Command Injection

An adversary exploits weaknesses in input validation on web-mail servers to execute commands on the IMAP/SMTP server. Web-mail servers often sit between the Internet and the IMAP or SMTP mail server. User requests are received by the web-mail servers which then query the back-end mail server for the requested information and return this response to the user. In an IMAP/SMTP command injection attack, mail-server commands are embedded in parts of the request sent to the web-mail server. If the web-mail server fails to adequately sanitize these requests, these commands are then sent to the back-end mail server when it is queried by the web-mail server, where the commands are then executed. This attack can be especially dangerous since administrators may assume that the back-end server is protected against direct Internet access and therefore may not secure it adequately against the execution of malicious commands.

CAPEC-248: Command Injection

An adversary looking to execute a command of their choosing, injects new items into an existing command thus modifying interpretation away from what was intended. Commands in this context are often standalone strings that are interpreted by a downstream component and cause specific responses. This type of attack is possible when untrusted values are used to build these command strings. Weaknesses in input validation or command construction can enable the attack and lead to successful exploitation.

CAPEC-40: Manipulating Writeable Terminal Devices

This attack exploits terminal devices that allow themselves to be written to by other users. The attacker sends command strings to the target terminal device hoping that the target user will hit enter and thereby execute the malicious command with their privileges. The attacker can send the results (such as copying /etc/passwd) to a known directory and collect once the attack has succeeded.

CAPEC-43: Exploiting Multiple Input Interpretation Layers

An attacker supplies the target software with input data that contains sequences of special characters designed to bypass input validation logic. This exploit relies on the target making multiples passes over the input data and processing a "layer" of special characters with each pass. In this manner, the attacker can disguise input that would otherwise be rejected as invalid by concealing it with layers of special/escape characters that are stripped off by subsequent processing steps. The goal is to first discover cases where the input validation layer executes before one or more parsing layers. That is, user input may go through the following logic in an application: <parser1> --> <input validator> --> <parser2>. In such cases, the attacker will need to provide input that will pass through the input validator, but after passing through parser2, will be converted into something that the input validator was supposed to stop.

CAPEC-75: Manipulating Writeable Configuration Files

Generally these are manually edited files that are not in the preview of the system administrators, any ability on the attackers' behalf to modify these files, for example in a CVS repository, gives unauthorized access directly to the application, the same as authorized users.

CAPEC-76: Manipulating Web Input to File System Calls