CWE-400
Weakness DiscouragedUncontrolled Resource Consumption
Abstraction: Class · Status: Draft
The product does not properly control the allocation and maintenance of a limited resource.
Dimensions
- Behavior-Property: Uncontrolled
- Behavior-Type: Consumption
- Resource-Type: Resource
Mapping guidance
CWE-400 is intended for incorrect behaviors in which the product is expected to track and restrict how many resources it consumes, but CWE-400 is often misused because it is conflated with the "technical impact" of vulnerabilities in which resource consumption occurs. It is sometimes used for low-information vulnerability reports. It is a level-1 Class (i.e., a child of a Pillar).
Closely analyze the specific mistake that is causing resource consumption, and perform a CWE mapping for that mistake. Consider children/descendants.
Modes of introduction
The product could be operated in a system or environment with lower resource limits than expected, which might make it easier for attackers to consume all available resources.
The product could be configured with lower resource limits than expected, which might make it easier for attackers to consume all available resources.
The designer might not consider how to handle and throttle excessive resource requests, which typically requires careful planning to handle more gracefully than a crash or exit.
There are at least three distinct scenarios that can commonly lead to resource exhaustion:
Lack of throttling for the number of allocated resources.
Losing all references to a resource before reaching the shutdown stage.
Not closing/returning a resource after processing.
Resource exhaustion problems often occur due to an incorrect implementation of the following situations:
Error conditions and other exceptional circumstances.
Confusion over which part of the program is responsible for releasing the resource.
Detection methods
Automated Static Analysis
Automated static analysis typically has limited utility in recognizing resource exhaustion problems, except for program-independent system resources such as files, sockets, and processes. For system resources, automated static analysis may be able to detect circumstances in which resources are not released after they have expired. Automated analysis of configuration files may be able to detect settings that do not specify a maximum value.
Automated static analysis tools will not be appropriate for detecting exhaustion of custom resources, such as an intended security policy in which a bulletin board user is only allowed to make a limited number of posts per day.
Effectiveness: Limited
Automated Dynamic Analysis
Certain automated dynamic analysis techniques may be effective in spotting resource exhaustion problems, especially with resources such as processes, memory, and connections. The technique may involve generating a large number of requests to the product within a short time frame.
Effectiveness: Moderate
Fuzzing
While fuzzing is typically geared toward finding low-level implementation bugs, it can inadvertently find resource exhaustion problems. This can occur when the fuzzer generates a large number of test cases but does not restart the targeted product in between test cases. If an individual test case produces a crash, but it does not do so reliably, then an inability to handle resource exhaustion may be the cause.
Effectiveness: Opportunistic
Notes
Theoretical
Vulnerability theory is largely about how behaviors and resources interact. "Resource exhaustion" can be regarded as either a consequence or an attack, depending on the perspective. This entry is an attempt to reflect the underlying weaknesses that enable these attacks (or consequences) to take place.
Other
Database queries that take a long time to process are good DoS targets. An attacker would have to write a few lines of code to generate enough traffic to exceed the site's ability to keep up. This would effectively prevent authorized users from using the site at all. Resources can be exploited simply by ensuring that the target machine must do much more work and consume more resources in order to service a request than the attacker must do to initiate a request.
A prime example of this can be found in old switches that were vulnerable to "macof" attacks (so named for a tool developed by Dugsong). These attacks flooded a switch with random IP and MAC address combinations, therefore exhausting the switch's cache, which held the information of which port corresponded to which MAC addresses. Once this cache was exhausted, the switch would fail in an insecure way and would begin to act simply as a hub, broadcasting all traffic on all ports and allowing for basic sniffing attacks.
Limited resources include memory, file system storage, database connection pool entries, CPU, and others.
Content history
Suggested mappings to ISA/IEC 62443.
Suggested mappings to ISA/IEC 62443.
Provided diagram to improve CWE usability.
updated Time_of_Introduction
Suggested OWASP Top Ten 2004 mapping
updated Common_Consequences, Relationships, Other_Notes, Taxonomy_Mappings
updated Description, Name, Relationships
updated Description
updated Name, Relationships
updated Description, Relationships
updated Relationships
updated Common_Consequences, Demonstrative_Examples, Detection_Factors, Likelihood_of_Exploit, Observed_Examples, Other_Notes, Potential_Mitigations, References
updated Detection_Factors, Potential_Mitigations, References, Taxonomy_Mappings
updated Related_Attack_Patterns
updated Description
updated Demonstrative_Examples
updated Common_Consequences, Relationships, Taxonomy_Mappings
updated Demonstrative_Examples, Related_Attack_Patterns, Relationships, Taxonomy_Mappings
updated Relationships
updated Relationships, Taxonomy_Mappings
updated Related_Attack_Patterns, Relationships
updated Relationships
updated Applicable_Platforms, Demonstrative_Examples, Likelihood_of_Exploit, Potential_Mitigations, References, Relationships
updated References, Type
updated Alternate_Terms, Description, Name, Relationships, Taxonomy_Mappings, Theoretical_Notes
updated Related_Attack_Patterns, Relationships
updated Description, Relationships
updated Description, References, Related_Attack_Patterns, Relationships
updated Description, Maintenance_Notes
updated Relationships
updated Related_Attack_Patterns
updated Observed_Examples, Relationships
updated Observed_Examples, Relationships
updated Common_Consequences, Description, Detection_Factors, Maintenance_Notes, Related_Attack_Patterns, Taxonomy_Mappings
updated Demonstrative_Examples, Relationships, Taxonomy_Mappings
updated Mapping_Notes, Relationships
updated Relationships
updated Common_Consequences, Description, Diagram, Modes_of_Introduction, Other_Notes, Time_of_Introduction
updated Observed_Examples, References
updated Applicable_Platforms, Maintenance_Notes, Weakness_Ordinalities
updated Applicable_Platforms, Maintenance_Notes, Mapping_Notes, Other_Notes
updated Applicable_Platforms, Dimensions, References, Relationships, Taxonomy_Mappings
7207 vulnerabilities reference this CWE, most recent first.
CVE-2017-7935 (GCVE-0-2017-7935)
Vulnerability from cvelistv5 – Published: 2017-05-19 02:43 – Updated: 2024-08-05 16:19| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-17-131-01 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Phoenix Contact GmbH mGuard |
Affected:
Phoenix Contact GmbH mGuard
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:19:29.422Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-131-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Phoenix Contact GmbH mGuard",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Phoenix Contact GmbH mGuard"
}
]
}
],
"datePublic": "2017-05-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A Resource Exhaustion issue was discovered in Phoenix Contact GmbH mGuard firmware versions 8.3.0 to 8.4.2. An attacker may compromise the device\u0027s availability by performing multiple initial VPN requests."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-05-19T02:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-131-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2017-7935",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Phoenix Contact GmbH mGuard",
"version": {
"version_data": [
{
"version_value": "Phoenix Contact GmbH mGuard"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Resource Exhaustion issue was discovered in Phoenix Contact GmbH mGuard firmware versions 8.3.0 to 8.4.2. An attacker may compromise the device\u0027s availability by performing multiple initial VPN requests."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-131-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-131-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-7935",
"datePublished": "2017-05-19T02:43:00.000Z",
"dateReserved": "2017-04-18T00:00:00.000Z",
"dateUpdated": "2024-08-05T16:19:29.422Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-7521 (GCVE-0-2017-7521)
Vulnerability from cvelistv5 – Published: 2017-06-27 13:00 – Updated: 2024-08-05 16:04| URL | Tags |
|---|---|
| https://community.openvpn.net/openvpn/wiki/Vulner… | x_refsource_CONFIRM |
| http://www.securitytracker.com/id/1038768 | vdb-entryx_refsource_SECTRACK |
| http://www.securityfocus.com/bid/99230 | vdb-entryx_refsource_BID |
| http://www.debian.org/security/2017/dsa-3900 | vendor-advisoryx_refsource_DEBIAN |
| Vendor | Product | Version | |
|---|---|---|---|
| OpenVPN Technologies, Inc | OpenVPN |
Affected:
before 2.4.3
Affected: before 2.3.17 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:04:11.856Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://community.openvpn.net/openvpn/wiki/VulnerabilitiesFixedInOpenVPN243"
},
{
"name": "1038768",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1038768"
},
{
"name": "99230",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/99230"
},
{
"name": "DSA-3900",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN",
"x_transferred"
],
"url": "http://www.debian.org/security/2017/dsa-3900"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "OpenVPN",
"vendor": "OpenVPN Technologies, Inc",
"versions": [
{
"status": "affected",
"version": "before 2.4.3"
},
{
"status": "affected",
"version": "before 2.3.17"
}
]
}
],
"datePublic": "2017-06-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "OpenVPN versions before 2.4.3 and before 2.3.17 are vulnerable to remote denial-of-service due to memory exhaustion caused by memory leaks and double-free issue in extract_x509_extension()."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-11-03T18:57:01.000Z",
"orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"shortName": "redhat"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://community.openvpn.net/openvpn/wiki/VulnerabilitiesFixedInOpenVPN243"
},
{
"name": "1038768",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1038768"
},
{
"name": "99230",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/99230"
},
{
"name": "DSA-3900",
"tags": [
"vendor-advisory",
"x_refsource_DEBIAN"
],
"url": "http://www.debian.org/security/2017/dsa-3900"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secalert@redhat.com",
"ID": "CVE-2017-7521",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "OpenVPN",
"version": {
"version_data": [
{
"version_value": "before 2.4.3"
},
{
"version_value": "before 2.3.17"
}
]
}
}
]
},
"vendor_name": "OpenVPN Technologies, Inc"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "OpenVPN versions before 2.4.3 and before 2.3.17 are vulnerable to remote denial-of-service due to memory exhaustion caused by memory leaks and double-free issue in extract_x509_extension()."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://community.openvpn.net/openvpn/wiki/VulnerabilitiesFixedInOpenVPN243",
"refsource": "CONFIRM",
"url": "https://community.openvpn.net/openvpn/wiki/VulnerabilitiesFixedInOpenVPN243"
},
{
"name": "1038768",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1038768"
},
{
"name": "99230",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/99230"
},
{
"name": "DSA-3900",
"refsource": "DEBIAN",
"url": "http://www.debian.org/security/2017/dsa-3900"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"assignerShortName": "redhat",
"cveId": "CVE-2017-7521",
"datePublished": "2017-06-27T13:00:00.000Z",
"dateReserved": "2017-04-05T00:00:00.000Z",
"dateUpdated": "2024-08-05T16:04:11.856Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-6043 (GCVE-0-2017-6043)
Vulnerability from cvelistv5 – Published: 2017-06-21 19:00 – Updated: 2024-08-05 15:18| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-17-164-01 | x_refsource_MISC |
| http://www.securityfocus.com/bid/99066 | vdb-entryx_refsource_BID |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Trihedral VTScada |
Affected:
Trihedral VTScada
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T15:18:49.741Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-164-01"
},
{
"name": "99066",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/99066"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Trihedral VTScada",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Trihedral VTScada"
}
]
}
],
"datePublic": "2017-06-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A Resource Consumption issue was discovered in Trihedral VTScada Versions prior to 11.2.26. The client does not properly validate the input or limit the amount of resources that are utilized by an attacker, which can be used to consume more resources than are available."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-06-22T09:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-164-01"
},
{
"name": "99066",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/99066"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2017-6043",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Trihedral VTScada",
"version": {
"version_data": [
{
"version_value": "Trihedral VTScada"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Resource Consumption issue was discovered in Trihedral VTScada Versions prior to 11.2.26. The client does not properly validate the input or limit the amount of resources that are utilized by an attacker, which can be used to consume more resources than are available."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-164-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-164-01"
},
{
"name": "99066",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/99066"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-6043",
"datePublished": "2017-06-21T19:00:00.000Z",
"dateReserved": "2017-02-16T00:00:00.000Z",
"dateUpdated": "2024-08-05T15:18:49.741Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-6024 (GCVE-0-2017-6024)
Vulnerability from cvelistv5 – Published: 2017-05-06 00:00 – Updated: 2024-08-05 15:18| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-17-094-05 | x_refsource_MISC |
| http://www.securityfocus.com/bid/98309 | vdb-entryx_refsource_BID |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Rockwell Automation ControlLogix 5580 and CompactLogix 5380 |
Affected:
Rockwell Automation ControlLogix 5580 and CompactLogix 5380
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T15:18:49.530Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-094-05"
},
{
"name": "98309",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/98309"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Rockwell Automation ControlLogix 5580 and CompactLogix 5380",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Rockwell Automation ControlLogix 5580 and CompactLogix 5380"
}
]
}
],
"datePublic": "2017-05-05T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A Resource Exhaustion issue was discovered in Rockwell Automation ControlLogix 5580 controllers V28.011, V28.012, and V28.013; ControlLogix 5580 controllers V29.011; CompactLogix 5380 controllers V28.011; and CompactLogix 5380 controllers V29.011. This vulnerability may allow an attacker to cause a denial of service condition by sending a series of specific CIP-based commands to the controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-05-08T09:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-094-05"
},
{
"name": "98309",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/98309"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2017-6024",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Rockwell Automation ControlLogix 5580 and CompactLogix 5380",
"version": {
"version_data": [
{
"version_value": "Rockwell Automation ControlLogix 5580 and CompactLogix 5380"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Resource Exhaustion issue was discovered in Rockwell Automation ControlLogix 5580 controllers V28.011, V28.012, and V28.013; ControlLogix 5580 controllers V29.011; CompactLogix 5380 controllers V28.011; and CompactLogix 5380 controllers V29.011. This vulnerability may allow an attacker to cause a denial of service condition by sending a series of specific CIP-based commands to the controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-094-05",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-094-05"
},
{
"name": "98309",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/98309"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-6024",
"datePublished": "2017-05-06T00:00:00.000Z",
"dateReserved": "2017-02-16T00:00:00.000Z",
"dateUpdated": "2024-08-05T15:18:49.530Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-6019 (GCVE-0-2017-6019)
Vulnerability from cvelistv5 – Published: 2017-04-07 22:00 – Updated: 2024-08-05 15:18| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-17-061-02 | x_refsource_MISC |
| http://download.schneider-electric.com/files?p_Do… | x_refsource_CONFIRM |
| http://www.securityfocus.com/bid/96543 | vdb-entryx_refsource_BID |
| https://www.exploit-db.com/exploits/41537/ | exploitx_refsource_EXPLOIT-DB |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Schneider Electric Conext ComBox |
Affected:
Schneider Electric Conext ComBox
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T15:18:49.485Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-061-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-01"
},
{
"name": "96543",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/96543"
},
{
"name": "41537",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "https://www.exploit-db.com/exploits/41537/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Schneider Electric Conext ComBox",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Schneider Electric Conext ComBox"
}
]
}
],
"datePublic": "2017-04-07T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-15T09:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-061-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-01"
},
{
"name": "96543",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/96543"
},
{
"name": "41537",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "https://www.exploit-db.com/exploits/41537/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2017-6019",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Schneider Electric Conext ComBox",
"version": {
"version_data": [
{
"version_value": "Schneider Electric Conext ComBox"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-061-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-061-02"
},
{
"name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-01",
"refsource": "CONFIRM",
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-01"
},
{
"name": "96543",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/96543"
},
{
"name": "41537",
"refsource": "EXPLOIT-DB",
"url": "https://www.exploit-db.com/exploits/41537/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-6019",
"datePublished": "2017-04-07T22:00:00.000Z",
"dateReserved": "2017-02-16T00:00:00.000Z",
"dateUpdated": "2024-08-05T15:18:49.485Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-6017 (GCVE-0-2017-6017)
Vulnerability from cvelistv5 – Published: 2017-06-30 02:35 – Updated: 2024-08-05 15:18| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
| http://www.securityfocus.com/bid/96414 | vdb-entryx_refsource_BID |
| https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Schneider Electric Modicon M340 PLC |
Affected:
Schneider Electric Modicon M340 PLC
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T15:18:49.611Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/"
},
{
"name": "96414",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/96414"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Schneider Electric Modicon M340 PLC",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Schneider Electric Modicon M340 PLC"
}
]
}
],
"datePublic": "2017-06-29T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-12-24T15:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/"
},
{
"name": "96414",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/96414"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2017-6017",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Schneider Electric Modicon M340 PLC",
"version": {
"version_data": [
{
"version_value": "Schneider Electric Modicon M340 PLC"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/"
},
{
"name": "96414",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/96414"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-6017",
"datePublished": "2017-06-30T02:35:00.000Z",
"dateReserved": "2017-02-16T00:00:00.000Z",
"dateUpdated": "2024-08-05T15:18:49.611Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-2681 (GCVE-0-2017-2681)
Vulnerability from cvelistv5 – Published: 2017-05-11 10:00 – Updated: 2024-09-10 09:33- CWE-400 - Uncontrolled Resource Consumption
| URL | Tags |
|---|---|
| http://www.securitytracker.com/id/1038463 | vdb-entryx_refsource_SECTRACK |
| http://www.securityfocus.com/bid/98369 | vdb-entryx_refsource_BID |
| https://www.siemens.com/cert/pool/cert/siemens_se… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/html/… |
50 of 124 products shown. All of them on the page of CVE-2017-2681.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-2681",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-23T20:22:19.045364Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-23T20:22:26.181Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:02:07.386Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1038463",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1038463"
},
{
"name": "98369",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/98369"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.1 Patch04"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2.1 Patch03"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4.0 Patch01"
}
]
},
{
"defaultStatus": "unknown",
"product": "IE/AS-i Link PN IO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "IE/PB-Link (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.03"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W-700 IEEE 802.11n family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-200 family (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.4.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X408 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X414",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.10.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM-400 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR-500 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CM 1542-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CM 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1604",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1616",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 OPC UA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC DK-16xx PN IO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200AL IM 157-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200M (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-3 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-4 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN: IO-Link Master",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200S (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-B",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-B Body",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-P Body",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 HR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 SR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 UR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF650R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF680R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF685R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.X.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CP51M1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CPU555",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Basic",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Standard",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX F 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCM w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.4 SP1 HF5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCP w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.2 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G110M w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP6 HF3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP6 HF3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V4.7: All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S110 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4 SP3 HF5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS V90 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 828D V4.5 and prior",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 SP6 HF2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 828D V4.7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP4 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 840D sl V4.5 and prior",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 SP6 HF2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 840D sl V4.7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP4 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS ACT 3SU1 interface module PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Motor Starter M200D PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter 3RW44 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP PSU8600 PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "Softnet PROFINET IO for PC-based Windows systems",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:20.658Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "1038463",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1038463"
},
{
"name": "98369",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/98369"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2017-2681",
"datePublished": "2017-05-11T10:00:00.000Z",
"dateReserved": "2016-12-01T00:00:00.000Z",
"dateUpdated": "2024-09-10T09:33:20.658Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-2680 (GCVE-0-2017-2680)
Vulnerability from cvelistv5 – Published: 2017-05-11 01:00 – Updated: 2024-09-10 09:33- CWE-400 - Uncontrolled Resource Consumption
| URL | Tags |
|---|---|
| http://www.securitytracker.com/id/1038463 | vdb-entryx_refsource_SECTRACK |
| http://www.securityfocus.com/bid/98369 | vdb-entryx_refsource_BID |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02 | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.siemens.com/cert/pool/cert/siemens_se… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/html/… | |
| https://cert-portal.siemens.com/productcert/html/… | |
| https://cert-portal.siemens.com/productcert/html/… |
50 of 139 products shown. All of them on the page of CVE-2017-2680.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-2680",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T13:26:04.237652Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T13:26:15.327Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:02:07.270Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1038463",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1038463"
},
{
"name": "98369",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/98369"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.1 Patch04"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2.1 Patch03"
}
]
},
{
"defaultStatus": "unknown",
"product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4.0 Patch01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 12\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 15\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 19\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "Extension Unit 22\" PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V01.01.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "IE/AS-i Link PN IO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "IE/PB-Link (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.03"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE W-700 IEEE 802.11n family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-200 family (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.4.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X408 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X414",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.10.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XM-400 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XR-500 family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CM 1542-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CM 1542SP-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-7 LTE US",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1243-8 IRC",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1.82"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0.15"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1604",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1616",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 1626",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.1.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC CP 443-1 OPC UA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC DK-16xx PN IO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200AL IM 157-1 PN",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200M (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-3 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200pro IM 154-4 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN HS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200ecoPN: IO-Link Master",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ET200S (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-B",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-B Body",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-P",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV420 SR-P Body",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 HR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 SR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC MV440 UR",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF650R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF680R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC RF685R",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-200 SMART",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.X.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V6.0.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V7.0.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CP51M1",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC TDC CPU555",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.1.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Basic",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Teleservice Adapter IE Standard",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC WinAC RTX F 2010",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2010 SP3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.0.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4 HF26"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCM w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.4 SP1 HF5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS DCP w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.2 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G110M w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP6 HF3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP6 HF3"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G130 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V4.7: All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS G150 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GH150 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP5 HF7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GL150 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS GM150 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF31"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S110 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.4 SP3 HF5"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.7 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF27"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS S150 V4.8 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 HF4"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7.0 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 HF30"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7.4 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SL150 V4.7.5 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS SM120 V4.7 w. PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.8 SP2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINAMICS V90 w. PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.01"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 828D V4.5 and prior",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 SP6 HF2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 828D V4.7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP4 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 840D sl V4.5 and prior",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 SP6 HF2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SINUMERIK 840D sl V4.7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.7 SP4 HF1"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V4.1.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS ACT 3SU1 interface module PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Motor Starter M200D PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIRIUS Soft Starter 3RW44 PN",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP PSU8600 PROFINET",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "Softnet PROFINET IO for PC-based Windows systems",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T09:33:18.492Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "1038463",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1038463"
},
{
"name": "98369",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/98369"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2017-2680",
"datePublished": "2017-05-11T01:00:00.000Z",
"dateReserved": "2016-12-01T00:00:00.000Z",
"dateUpdated": "2024-09-10T09:33:18.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-0938 (GCVE-0-2017-0938)
Vulnerability from cvelistv5 – Published: 2019-02-12 22:00 – Updated: 2024-09-16 18:49- CWE-400 - Denial of Service (CWE-400)
| URL | Tags |
|---|---|
| https://community.ubnt.com/t5/airMAX-Updates-Blog… | x_refsource_MISC |
| https://hackerone.com/reports/221625 | x_refsource_MISC |
| https://community.ubnt.com/t5/airMAX-Updates-Blog… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| HackerOne | airMAX, EdgeMAX |
Affected:
airMAX < 8.3.2, airMAX < 6.0.7, EdgeRouter < v1.9.7
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T13:25:17.343Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://community.ubnt.com/t5/airMAX-Updates-Blog/airOS-v6-0-7-Has-Been-Released/ba-p/2056522"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://hackerone.com/reports/221625"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://community.ubnt.com/t5/airMAX-Updates-Blog/airOS-v8-3-2-Has-Been-Released/ba-p/2049215"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "airMAX, EdgeMAX",
"vendor": "HackerOne",
"versions": [
{
"status": "affected",
"version": "airMAX \u003c 8.3.2, airMAX \u003c 6.0.7, EdgeRouter \u003c v1.9.7"
}
]
}
],
"datePublic": "2019-02-06T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Denial of Service attack in airMAX \u003c 8.3.2 , airMAX \u003c 6.0.7 and EdgeMAX \u003c 1.9.7 allow attackers to use the Discovery Protocol in amplification attacks."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "Denial of Service (CWE-400)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-02-12T21:57:01.000Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://community.ubnt.com/t5/airMAX-Updates-Blog/airOS-v6-0-7-Has-Been-Released/ba-p/2056522"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://hackerone.com/reports/221625"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://community.ubnt.com/t5/airMAX-Updates-Blog/airOS-v8-3-2-Has-Been-Released/ba-p/2049215"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "support@hackerone.com",
"DATE_PUBLIC": "2019-02-06T00:00:00",
"ID": "CVE-2017-0938",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "airMAX, EdgeMAX",
"version": {
"version_data": [
{
"version_value": "airMAX \u003c 8.3.2, airMAX \u003c 6.0.7, EdgeRouter \u003c v1.9.7"
}
]
}
}
]
},
"vendor_name": "HackerOne"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Denial of Service attack in airMAX \u003c 8.3.2 , airMAX \u003c 6.0.7 and EdgeMAX \u003c 1.9.7 allow attackers to use the Discovery Protocol in amplification attacks."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Denial of Service (CWE-400)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://community.ubnt.com/t5/airMAX-Updates-Blog/airOS-v6-0-7-Has-Been-Released/ba-p/2056522",
"refsource": "MISC",
"url": "https://community.ubnt.com/t5/airMAX-Updates-Blog/airOS-v6-0-7-Has-Been-Released/ba-p/2056522"
},
{
"name": "https://hackerone.com/reports/221625",
"refsource": "MISC",
"url": "https://hackerone.com/reports/221625"
},
{
"name": "https://community.ubnt.com/t5/airMAX-Updates-Blog/airOS-v8-3-2-Has-Been-Released/ba-p/2049215",
"refsource": "MISC",
"url": "https://community.ubnt.com/t5/airMAX-Updates-Blog/airOS-v8-3-2-Has-Been-Released/ba-p/2049215"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2017-0938",
"datePublished": "2019-02-12T22:00:00.000Z",
"dateReserved": "2016-11-30T00:00:00.000Z",
"dateUpdated": "2024-09-16T18:49:35.479Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-10544 (GCVE-0-2016-10544)
Vulnerability from cvelistv5 – Published: 2018-05-31 20:00 – Updated: 2024-09-17 02:56- CWE-400 - Denial of Service (CWE-400)
| URL | Tags |
|---|---|
| https://github.com/uWebSockets/uWebSockets/commit… | x_refsource_MISC |
| https://nodesecurity.io/advisories/149 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| HackerOne | uws node module |
Affected:
>=0.10.0 <=0.10.8
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T03:21:52.282Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/uWebSockets/uWebSockets/commit/37deefd01f0875e133ea967122e3a5e421b8fcd9"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://nodesecurity.io/advisories/149"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "uws node module",
"vendor": "HackerOne",
"versions": [
{
"status": "affected",
"version": "\u003e=0.10.0 \u003c=0.10.8"
}
]
}
],
"datePublic": "2018-04-26T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "uws is a WebSocket server library. By sending a 256mb websocket message to a uws server instance with permessage-deflate enabled, there is a possibility used compression will shrink said 256mb down to less than 16mb of websocket payload which passes the length check of 16mb payload. This data will then inflate up to 256mb and crash the node process by exceeding V8\u0027s maximum string size. This affects uws \u003e=0.10.0 \u003c=0.10.8."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "Denial of Service (CWE-400)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-05-31T19:57:01.000Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/uWebSockets/uWebSockets/commit/37deefd01f0875e133ea967122e3a5e421b8fcd9"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://nodesecurity.io/advisories/149"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "support@hackerone.com",
"DATE_PUBLIC": "2018-04-26T00:00:00",
"ID": "CVE-2016-10544",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "uws node module",
"version": {
"version_data": [
{
"version_value": "\u003e=0.10.0 \u003c=0.10.8"
}
]
}
}
]
},
"vendor_name": "HackerOne"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "uws is a WebSocket server library. By sending a 256mb websocket message to a uws server instance with permessage-deflate enabled, there is a possibility used compression will shrink said 256mb down to less than 16mb of websocket payload which passes the length check of 16mb payload. This data will then inflate up to 256mb and crash the node process by exceeding V8\u0027s maximum string size. This affects uws \u003e=0.10.0 \u003c=0.10.8."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Denial of Service (CWE-400)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/uWebSockets/uWebSockets/commit/37deefd01f0875e133ea967122e3a5e421b8fcd9",
"refsource": "MISC",
"url": "https://github.com/uWebSockets/uWebSockets/commit/37deefd01f0875e133ea967122e3a5e421b8fcd9"
},
{
"name": "https://nodesecurity.io/advisories/149",
"refsource": "MISC",
"url": "https://nodesecurity.io/advisories/149"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2016-10544",
"datePublished": "2018-05-31T20:00:00.000Z",
"dateReserved": "2017-10-29T00:00:00.000Z",
"dateUpdated": "2024-09-17T02:56:54.139Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
Design throttling mechanisms into the system architecture. The best protection is to limit the amount of resources that an unauthorized user can cause to be expended. A strong authentication and access control model will help prevent such attacks from occurring in the first place. The login application should be protected against DoS attacks as much as possible. Limiting the database access, perhaps by caching result sets, can help minimize the resources expended. To further limit the potential for a DoS attack, consider tracking the rate of requests received from users and blocking requests that exceed a defined rate threshold.
Mitigation
- Mitigation of resource exhaustion attacks requires that the target system either:
- recognizes the attack and denies that user further access for a given amount of time, or
- uniformly throttles all requests in order to make it more difficult to consume resources more quickly than they can again be freed.
- The first of these solutions is an issue in itself though, since it may allow attackers to prevent the use of the system by a particular valid user. If the attacker impersonates the valid user, they may be able to prevent the user from accessing the server in question.
- The second solution is simply difficult to effectively institute -- and even when properly done, it does not provide a full solution. It simply makes the attack require more resources on the part of the attacker.
Mitigation
Ensure that protocols have specific limits of scale placed on them.
Mitigation
Ensure that all failures in resource allocation place the system into a safe posture.
CAPEC-147: XML Ping of the Death
An attacker initiates a resource depletion attack where a large number of small XML messages are delivered at a sufficiently rapid rate to cause a denial of service or crash of the target. Transactions such as repetitive SOAP transactions can deplete resources faster than a simple flooding attack because of the additional resources used by the SOAP protocol and the resources necessary to process SOAP messages. The transactions used are immaterial as long as they cause resource utilization on the target. In other words, this is a normal flooding attack augmented by using messages that will require extra processing on the target.
CAPEC-227: Sustained Client Engagement
An adversary attempts to deny legitimate users access to a resource by continually engaging a specific resource in an attempt to keep the resource tied up as long as possible. The adversary's primary goal is not to crash or flood the target, which would alert defenders; rather it is to repeatedly perform actions or abuse algorithmic flaws such that a given resource is tied up and not available to a legitimate user. By carefully crafting a requests that keep the resource engaged through what is seemingly benign requests, legitimate users are limited or completely denied access to the resource.
CAPEC-492: Regular Expression Exponential Blowup
An adversary may execute an attack on a program that uses a poor Regular Expression(Regex) implementation by choosing input that results in an extreme situation for the Regex. A typical extreme situation operates at exponential time compared to the input size. This is due to most implementations using a Nondeterministic Finite Automaton(NFA) state machine to be built by the Regex algorithm since NFA allows backtracking and thus more complex regular expressions.