CWE-400
Weakness DiscouragedUncontrolled Resource Consumption
Abstraction: Class · Status: Draft
The product does not properly control the allocation and maintenance of a limited resource.
Dimensions
- Behavior-Property: Uncontrolled
- Behavior-Type: Consumption
- Resource-Type: Resource
Mapping guidance
CWE-400 is intended for incorrect behaviors in which the product is expected to track and restrict how many resources it consumes, but CWE-400 is often misused because it is conflated with the "technical impact" of vulnerabilities in which resource consumption occurs. It is sometimes used for low-information vulnerability reports. It is a level-1 Class (i.e., a child of a Pillar).
Closely analyze the specific mistake that is causing resource consumption, and perform a CWE mapping for that mistake. Consider children/descendants.
Modes of introduction
The product could be operated in a system or environment with lower resource limits than expected, which might make it easier for attackers to consume all available resources.
The product could be configured with lower resource limits than expected, which might make it easier for attackers to consume all available resources.
The designer might not consider how to handle and throttle excessive resource requests, which typically requires careful planning to handle more gracefully than a crash or exit.
There are at least three distinct scenarios that can commonly lead to resource exhaustion:
Lack of throttling for the number of allocated resources.
Losing all references to a resource before reaching the shutdown stage.
Not closing/returning a resource after processing.
Resource exhaustion problems often occur due to an incorrect implementation of the following situations:
Error conditions and other exceptional circumstances.
Confusion over which part of the program is responsible for releasing the resource.
Detection methods
Automated Static Analysis
Automated static analysis typically has limited utility in recognizing resource exhaustion problems, except for program-independent system resources such as files, sockets, and processes. For system resources, automated static analysis may be able to detect circumstances in which resources are not released after they have expired. Automated analysis of configuration files may be able to detect settings that do not specify a maximum value.
Automated static analysis tools will not be appropriate for detecting exhaustion of custom resources, such as an intended security policy in which a bulletin board user is only allowed to make a limited number of posts per day.
Effectiveness: Limited
Automated Dynamic Analysis
Certain automated dynamic analysis techniques may be effective in spotting resource exhaustion problems, especially with resources such as processes, memory, and connections. The technique may involve generating a large number of requests to the product within a short time frame.
Effectiveness: Moderate
Fuzzing
While fuzzing is typically geared toward finding low-level implementation bugs, it can inadvertently find resource exhaustion problems. This can occur when the fuzzer generates a large number of test cases but does not restart the targeted product in between test cases. If an individual test case produces a crash, but it does not do so reliably, then an inability to handle resource exhaustion may be the cause.
Effectiveness: Opportunistic
Notes
Theoretical
Vulnerability theory is largely about how behaviors and resources interact. "Resource exhaustion" can be regarded as either a consequence or an attack, depending on the perspective. This entry is an attempt to reflect the underlying weaknesses that enable these attacks (or consequences) to take place.
Other
Database queries that take a long time to process are good DoS targets. An attacker would have to write a few lines of code to generate enough traffic to exceed the site's ability to keep up. This would effectively prevent authorized users from using the site at all. Resources can be exploited simply by ensuring that the target machine must do much more work and consume more resources in order to service a request than the attacker must do to initiate a request.
A prime example of this can be found in old switches that were vulnerable to "macof" attacks (so named for a tool developed by Dugsong). These attacks flooded a switch with random IP and MAC address combinations, therefore exhausting the switch's cache, which held the information of which port corresponded to which MAC addresses. Once this cache was exhausted, the switch would fail in an insecure way and would begin to act simply as a hub, broadcasting all traffic on all ports and allowing for basic sniffing attacks.
Limited resources include memory, file system storage, database connection pool entries, CPU, and others.
Content history
Suggested mappings to ISA/IEC 62443.
Suggested mappings to ISA/IEC 62443.
Provided diagram to improve CWE usability.
updated Time_of_Introduction
Suggested OWASP Top Ten 2004 mapping
updated Common_Consequences, Relationships, Other_Notes, Taxonomy_Mappings
updated Description, Name, Relationships
updated Description
updated Name, Relationships
updated Description, Relationships
updated Relationships
updated Common_Consequences, Demonstrative_Examples, Detection_Factors, Likelihood_of_Exploit, Observed_Examples, Other_Notes, Potential_Mitigations, References
updated Detection_Factors, Potential_Mitigations, References, Taxonomy_Mappings
updated Related_Attack_Patterns
updated Description
updated Demonstrative_Examples
updated Common_Consequences, Relationships, Taxonomy_Mappings
updated Demonstrative_Examples, Related_Attack_Patterns, Relationships, Taxonomy_Mappings
updated Relationships
updated Relationships, Taxonomy_Mappings
updated Related_Attack_Patterns, Relationships
updated Relationships
updated Applicable_Platforms, Demonstrative_Examples, Likelihood_of_Exploit, Potential_Mitigations, References, Relationships
updated References, Type
updated Alternate_Terms, Description, Name, Relationships, Taxonomy_Mappings, Theoretical_Notes
updated Related_Attack_Patterns, Relationships
updated Description, Relationships
updated Description, References, Related_Attack_Patterns, Relationships
updated Description, Maintenance_Notes
updated Relationships
updated Related_Attack_Patterns
updated Observed_Examples, Relationships
updated Observed_Examples, Relationships
updated Common_Consequences, Description, Detection_Factors, Maintenance_Notes, Related_Attack_Patterns, Taxonomy_Mappings
updated Demonstrative_Examples, Relationships, Taxonomy_Mappings
updated Mapping_Notes, Relationships
updated Relationships
updated Common_Consequences, Description, Diagram, Modes_of_Introduction, Other_Notes, Time_of_Introduction
updated Observed_Examples, References
updated Applicable_Platforms, Maintenance_Notes, Weakness_Ordinalities
updated Applicable_Platforms, Maintenance_Notes, Mapping_Notes, Other_Notes
updated Applicable_Platforms, Dimensions, References, Relationships, Taxonomy_Mappings
7207 vulnerabilities reference this CWE, most recent first.
CVE-2021-27385 (GCVE-0-2021-27385)
Vulnerability from cvelistv5 – Published: 2021-05-12 13:18 – Updated: 2026-06-02 19:07- CWE-400 - Uncontrolled Resource Consumption
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:16.474Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2021-27385",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-02T19:07:48.517703Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-02T19:07:52.624Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 6"
}
]
},
{
"product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 4"
}
]
},
{
"product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 6"
}
]
},
{
"product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 4"
}
]
},
{
"product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 6"
}
]
},
{
"product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 4"
}
]
},
{
"product": "SIMATIC WinCC Runtime Advanced V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Update 6"
}
]
},
{
"product": "SIMATIC WinCC Runtime Advanced V16",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V16 Update 4"
}
]
},
{
"product": "SINAMICS GH150",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINAMICS GL150 (with option X30)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINAMICS GM150 (with option X30)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINAMICS SH150",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINAMICS SL150",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINAMICS SM120",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINAMICS SM150",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SINAMICS SM150i",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-12T09:49:17.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-27385",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 6"
}
]
}
},
{
"product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 4"
}
]
}
},
{
"product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 6"
}
]
}
},
{
"product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 4"
}
]
}
},
{
"product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 6"
}
]
}
},
{
"product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 4"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Advanced V15",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Update 6"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Advanced V16",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V16 Update 4"
}
]
}
},
{
"product_name": "SINAMICS GH150",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINAMICS GL150 (with option X30)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINAMICS GM150 (with option X30)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINAMICS SH150",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINAMICS SL150",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINAMICS SM120",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINAMICS SM150",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SINAMICS SM150i",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-27385",
"datePublished": "2021-05-12T13:18:23.000Z",
"dateReserved": "2021-02-18T00:00:00.000Z",
"dateUpdated": "2026-06-02T19:07:52.624Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-26945 (GCVE-0-2021-26945)
Vulnerability from cvelistv5 – Published: 2021-06-08 11:39 – Updated: 2024-08-03 20:33| URL | Tags |
|---|---|
| https://bugzilla.redhat.com/show_bug.cgi?id=1947591 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:33:41.491Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1947591"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "OpenEXR",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "OpenEXR 3.0.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An integer overflow leading to a heap-buffer overflow was found in OpenEXR in versions before 3.0.1. An attacker could use this flaw to crash an application compiled with OpenEXR."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-08T11:39:06.000Z",
"orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"shortName": "redhat"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1947591"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secalert@redhat.com",
"ID": "CVE-2021-26945",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "OpenEXR",
"version": {
"version_data": [
{
"version_value": "OpenEXR 3.0.1"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An integer overflow leading to a heap-buffer overflow was found in OpenEXR in versions before 3.0.1. An attacker could use this flaw to crash an application compiled with OpenEXR."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://bugzilla.redhat.com/show_bug.cgi?id=1947591",
"refsource": "MISC",
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1947591"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"assignerShortName": "redhat",
"cveId": "CVE-2021-26945",
"datePublished": "2021-06-08T11:39:06.000Z",
"dateReserved": "2021-04-22T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:33:41.491Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-26260 (GCVE-0-2021-26260)
Vulnerability from cvelistv5 – Published: 2021-06-08 00:00 – Updated: 2024-08-03 20:19| URL | Tags |
|---|---|
| https://lists.fedoraproject.org/archives/list/pac… | vendor-advisory |
| https://bugzilla.redhat.com/show_bug.cgi?id=1947582 | |
| https://lists.debian.org/debian-lts-announce/2021… | mailing-list |
| https://www.debian.org/security/2022/dsa-5299 | vendor-advisory |
| https://lists.debian.org/debian-lts-announce/2022… | mailing-list |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:19:20.135Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "FEDORA-2021-6af32bfcd2",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/BXFLD4ZAXKAIWO6ZPBCQEEDZB5IG676K/"
},
{
"tags": [
"x_transferred"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1947582"
},
{
"name": "[debian-lts-announce] 20210703 [SECURITY] [DLA 2701-1] openexr security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2021/07/msg00001.html"
},
{
"name": "DSA-5299",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2022/dsa-5299"
},
{
"name": "[debian-lts-announce] 20221211 [SECURITY] [DLA 3236-1] openexr security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00022.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "OpenEXR",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "OpenEXR 3.0.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An integer overflow leading to a heap-buffer overflow was found in the DwaCompressor of OpenEXR in versions before 3.0.1. An attacker could use this flaw to crash an application compiled with OpenEXR. This is a different flaw from CVE-2021-23215."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-12T00:00:00.000Z",
"orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"shortName": "redhat"
},
"references": [
{
"name": "FEDORA-2021-6af32bfcd2",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/BXFLD4ZAXKAIWO6ZPBCQEEDZB5IG676K/"
},
{
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1947582"
},
{
"name": "[debian-lts-announce] 20210703 [SECURITY] [DLA 2701-1] openexr security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2021/07/msg00001.html"
},
{
"name": "DSA-5299",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2022/dsa-5299"
},
{
"name": "[debian-lts-announce] 20221211 [SECURITY] [DLA 3236-1] openexr security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00022.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"assignerShortName": "redhat",
"cveId": "CVE-2021-26260",
"datePublished": "2021-06-08T00:00:00.000Z",
"dateReserved": "2021-04-22T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:19:20.135Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-25909 (GCVE-0-2021-25909)
Vulnerability from cvelistv5 – Published: 2021-01-29 13:24 – Updated: 2024-09-16 18:24- CWE-400 - Uncontrolled Resource Consumption
| URL | Tags |
|---|---|
| https://www.incibe-cert.es/en/early-warning/ics-a… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| ZIV AUTOMATION | 4CCT-EA6-334126BF |
Affected:
3.23.80.27.36371
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:11:28.529Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.incibe-cert.es/en/early-warning/ics-advisories/4cct-vulnerable-denial-service-attack"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "4CCT-EA6-334126BF",
"vendor": "ZIV AUTOMATION",
"versions": [
{
"status": "affected",
"version": "3.23.80.27.36371"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Industrial Cybersecurity team of S21Sec, special mention to Aar\u00f3n Flecha Men\u00e9ndez"
}
],
"datePublic": "2021-01-28T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "ZIV Automation 4CCT-EA6-334126BF firmware version 3.23.80.27.36371, allows an unauthenticated, remote attacker to cause a denial of service condition on the device. An attacker could exploit this vulnerability by sending specific packets to the port 7919."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-01-29T13:24:37.000Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.incibe-cert.es/en/early-warning/ics-advisories/4cct-vulnerable-denial-service-attack"
}
],
"solutions": [
{
"lang": "en",
"value": "Update to firmware version 3.23.80.58.46120"
}
],
"source": {
"advisory": "INCIBE-2021-0039",
"discovery": "EXTERNAL"
},
"title": "ZIV AUTOMATION 4CCT Denial of Service vulnerability",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve-coordination@incibe.es",
"DATE_PUBLIC": "2021-01-28T09:00:00.000Z",
"ID": "CVE-2021-25909",
"STATE": "PUBLIC",
"TITLE": "ZIV AUTOMATION 4CCT Denial of Service vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "4CCT-EA6-334126BF",
"version": {
"version_data": [
{
"version_affected": "=",
"version_name": "3.23.80.27.36371",
"version_value": "3.23.80.27.36371"
}
]
}
}
]
},
"vendor_name": "ZIV AUTOMATION"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Industrial Cybersecurity team of S21Sec, special mention to Aar\u00f3n Flecha Men\u00e9ndez"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "ZIV Automation 4CCT-EA6-334126BF firmware version 3.23.80.27.36371, allows an unauthenticated, remote attacker to cause a denial of service condition on the device. An attacker could exploit this vulnerability by sending specific packets to the port 7919."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400 Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.incibe-cert.es/en/early-warning/ics-advisories/4cct-vulnerable-denial-service-attack",
"refsource": "CONFIRM",
"url": "https://www.incibe-cert.es/en/early-warning/ics-advisories/4cct-vulnerable-denial-service-attack"
}
]
},
"solution": [
{
"lang": "en",
"value": "Update to firmware version 3.23.80.58.46120"
}
],
"source": {
"advisory": "INCIBE-2021-0039",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2021-25909",
"datePublished": "2021-01-29T13:24:37.269Z",
"dateReserved": "2021-01-22T00:00:00.000Z",
"dateUpdated": "2024-09-16T18:24:13.155Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-25701 (GCVE-0-2021-25701)
Vulnerability from cvelistv5 – Published: 2021-07-21 12:37 – Updated: 2024-08-03 20:11- CWE-400 - Uncontrolled Resource Consumption (CWE-400)
| URL | Tags |
|---|---|
| https://advisory.teradici.com/security-advisories/103/ | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | - PCoIP Software Client |
Affected:
21.07.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:11:27.862Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://advisory.teradici.com/security-advisories/103/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "- PCoIP Software Client",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "21.07.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The fUSBHub driver in the PCoIP Software Client prior to version 21.07.0 had an error in object management during the handling of a variety of IOCTLs, which allowed an attacker to cause a denial of service."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "Uncontrolled Resource Consumption (CWE-400)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-21T12:37:39.000Z",
"orgId": "ba3c294d-a544-4fff-ad44-2de7c7bbb6be",
"shortName": "Teradici"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://advisory.teradici.com/security-advisories/103/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@teradici.com",
"ID": "CVE-2021-25701",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "- PCoIP Software Client",
"version": {
"version_data": [
{
"version_value": "21.07.0"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The fUSBHub driver in the PCoIP Software Client prior to version 21.07.0 had an error in object management during the handling of a variety of IOCTLs, which allowed an attacker to cause a denial of service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Uncontrolled Resource Consumption (CWE-400)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://advisory.teradici.com/security-advisories/103/",
"refsource": "MISC",
"url": "https://advisory.teradici.com/security-advisories/103/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "ba3c294d-a544-4fff-ad44-2de7c7bbb6be",
"assignerShortName": "Teradici",
"cveId": "CVE-2021-25701",
"datePublished": "2021-07-21T12:37:39.000Z",
"dateReserved": "2021-01-21T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:11:27.862Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-25659 (GCVE-0-2021-25659)
Vulnerability from cvelistv5 – Published: 2021-08-10 10:35 – Updated: 2024-08-03 20:11- CWE-400 - Uncontrolled Resource Consumption
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | Automation License Manager 5 |
Affected:
All versions
|
|
| Siemens | Automation License Manager 6 |
Affected:
All versions < V6.0 SP9 Update 2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:11:27.685Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-158827.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Automation License Manager 5",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "Automation License Manager 6",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V6.0 SP9 Update 2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Automation License Manager 5 (All versions), Automation License Manager 6 (All versions \u003c V6.0 SP9 Update 2). Sending specially crafted packets to port 4410/tcp of an affected system could lead to extensive memory being consumed and as such could cause a denial-of-service preventing legitimate users from using the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400: Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-10T10:35:25.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-158827.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-25659",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Automation License Manager 5",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "Automation License Manager 6",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V6.0 SP9 Update 2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Automation License Manager 5 (All versions), Automation License Manager 6 (All versions \u003c V6.0 SP9 Update 2). Sending specially crafted packets to port 4410/tcp of an affected system could lead to extensive memory being consumed and as such could cause a denial-of-service preventing legitimate users from using the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400: Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-158827.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-158827.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-25659",
"datePublished": "2021-08-10T10:35:25.000Z",
"dateReserved": "2021-01-21T00:00:00.000Z",
"dateUpdated": "2024-08-03T20:11:27.685Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-24893 (GCVE-0-2021-24893)
Vulnerability from cvelistv5 – Published: 2022-01-03 12:49 – Updated: 2024-08-03 19:49- CWE-400 - Uncontrolled Resource Consumption
| URL | Tags |
|---|---|
| https://wpscan.com/vulnerability/05d3af69-20b4-49… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Unknown | Stars Rating |
Affected:
3.5.1 , < 3.5.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T19:49:14.012Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://wpscan.com/vulnerability/05d3af69-20b4-499a-8322-2b53674d6a58"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Stars Rating",
"vendor": "Unknown",
"versions": [
{
"lessThan": "3.5.1",
"status": "affected",
"version": "3.5.1",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Drew Jones"
}
],
"descriptions": [
{
"lang": "en",
"value": "The Stars Rating WordPress plugin before 3.5.1 does not validate the submitted rating, allowing submission of long integer, causing a Denial of Service in the comments section, or pending comment dashboard depending if the user sent it as unauthenticated or authenticated."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-03T12:49:06.000Z",
"orgId": "1bfdd5d7-9bf6-4a53-96ea-42e2716d7a81",
"shortName": "WPScan"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://wpscan.com/vulnerability/05d3af69-20b4-499a-8322-2b53674d6a58"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Stars Rating \u003c 3.5.1 - Comments Denial of Service",
"x_generator": "WPScan CVE Generator",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "contact@wpscan.com",
"ID": "CVE-2021-24893",
"STATE": "PUBLIC",
"TITLE": "Stars Rating \u003c 3.5.1 - Comments Denial of Service"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Stars Rating",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "3.5.1",
"version_value": "3.5.1"
}
]
}
}
]
},
"vendor_name": "Unknown"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Drew Jones"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Stars Rating WordPress plugin before 3.5.1 does not validate the submitted rating, allowing submission of long integer, causing a Denial of Service in the comments section, or pending comment dashboard depending if the user sent it as unauthenticated or authenticated."
}
]
},
"generator": "WPScan CVE Generator",
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400 Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://wpscan.com/vulnerability/05d3af69-20b4-499a-8322-2b53674d6a58",
"refsource": "MISC",
"url": "https://wpscan.com/vulnerability/05d3af69-20b4-499a-8322-2b53674d6a58"
}
]
},
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "1bfdd5d7-9bf6-4a53-96ea-42e2716d7a81",
"assignerShortName": "WPScan",
"cveId": "CVE-2021-24893",
"datePublished": "2022-01-03T12:49:06.000Z",
"dateReserved": "2021-01-14T00:00:00.000Z",
"dateUpdated": "2024-08-03T19:49:14.012Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-23852 (GCVE-0-2021-23852)
Vulnerability from cvelistv5 – Published: 2021-06-09 14:18 – Updated: 2024-09-16 22:03- CWE-400 - Uncontrolled Resource Consumption
| URL | Tags |
|---|---|
| https://psirt.bosch.com/security-advisories/bosch… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Bosch | CPP Firmware |
Affected:
all
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T19:14:09.365Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"platforms": [
"CPP4, CPP6, CPP7, CPP7.3, CPP13"
],
"product": "CPP Firmware",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "all"
}
]
}
],
"datePublic": "2021-05-20T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An authenticated attacker with administrator rights Bosch IP cameras can call an URL with an invalid parameter that causes the camera to become unresponsive for a few seconds and cause a Denial of Service (DoS)."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-09T14:18:24.000Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
}
],
"source": {
"advisory": "BOSCH-SA-478243-BT",
"discovery": "UNKNOWN"
},
"title": "Denial of Service (DoS) due to invalid web parameter",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2021-05-20",
"ID": "CVE-2021-23852",
"STATE": "PUBLIC",
"TITLE": "Denial of Service (DoS) due to invalid web parameter"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CPP Firmware",
"version": {
"version_data": [
{
"platform": "CPP4, CPP6, CPP7, CPP7.3, CPP13",
"version_affected": "=",
"version_value": "all"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An authenticated attacker with administrator rights Bosch IP cameras can call an URL with an invalid parameter that causes the camera to become unresponsive for a few seconds and cause a Denial of Service (DoS)."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400 Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
}
]
},
"source": {
"advisory": "BOSCH-SA-478243-BT",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2021-23852",
"datePublished": "2021-06-09T14:18:24.707Z",
"dateReserved": "2021-01-12T00:00:00.000Z",
"dateUpdated": "2024-09-16T22:03:24.110Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-23236 (GCVE-0-2021-23236)
Vulnerability from cvelistv5 – Published: 2022-01-21 18:17 – Updated: 2025-04-16 16:48- CWE-400 - Uncontrolled Resource Consumption
| URL | Tags |
|---|---|
| https://www.cisa.gov/uscert/ics/advisories/icsma-… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Fresenius Kabi | Agilia Link+ |
Affected:
unspecified , < 3.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T19:05:55.456Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-23236",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T16:00:06.380083Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:48:05.390Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Agilia Link+",
"vendor": "Fresenius Kabi",
"versions": [
{
"lessThan": "3.0",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Julian Suleder (ERNW Research GmbH), Nils Emmerich (ERNW Research GmbH), Raphael Pavlidis (ERNW Research GmbH), and Dr. Oliver Matula (ERNW Enno Rey Netzwerke GmbH) reported these vulnerabilities to the German Federal Office for Information Security (BSI) in the context of the BSI project ManiMed (Medical Device Manipulation Project)."
}
],
"descriptions": [
{
"lang": "en",
"value": "Requests may be used to interrupt the normal operation of the device. When exploited, Fresenius Kabi Agilia Link+ version 3.0 must be rebooted via a hard reset triggered by pressing a button on the rack system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-21T18:17:35.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01"
}
],
"solutions": [
{
"lang": "en",
"value": "Fresenius Kabi has created new versions to address these vulnerabilities:\n\u2022\tLink+ v3.0 (D16 or later)\n\u2022\tVSS v1.0.3 (or later)\n\u2022\tAgilia Connect Pumps Wifi Module (D29 or later)\n\u2022\tAgilia Connect Partner v3.3.2 (or later) \nFresenius Kabi has initiated communication on this topic in April 2021 with customers to inform them about availability of the new versions in corresponding countries. Contact Fresenius Kabi online or by phone at 1-800-333-6925 for more information on updating to the newest version.\nFresenius Kabi also identified that early Link+ devices (approximatively 1200 devices) would need hardware change to support D16 or later firmware. Until those devices can be replaced in customers\u2019 installation, Fresenius Kabi recommends users to rely on CISA recommendation. \n"
}
],
"source": {
"advisory": "ICSMA-21-355-01",
"discovery": "EXTERNAL"
},
"title": "Fresenius Kabi Agilia Connect Infusion System uncontrolled resource consumption",
"workarounds": [
{
"lang": "en",
"value": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\n\u2022\tMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\n\u2022\tLocate control system networks and remote devices behind firewalls and isolate them from the business network.\n\u2022\tWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-23236",
"STATE": "PUBLIC",
"TITLE": "Fresenius Kabi Agilia Connect Infusion System uncontrolled resource consumption"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Agilia Link+",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "3.0"
}
]
}
}
]
},
"vendor_name": "Fresenius Kabi"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Julian Suleder (ERNW Research GmbH), Nils Emmerich (ERNW Research GmbH), Raphael Pavlidis (ERNW Research GmbH), and Dr. Oliver Matula (ERNW Enno Rey Netzwerke GmbH) reported these vulnerabilities to the German Federal Office for Information Security (BSI) in the context of the BSI project ManiMed (Medical Device Manipulation Project)."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Requests may be used to interrupt the normal operation of the device. When exploited, Fresenius Kabi Agilia Link+ version 3.0 must be rebooted via a hard reset triggered by pressing a button on the rack system."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-400 Uncontrolled Resource Consumption"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsma-21-355-01"
}
]
},
"solution": [
{
"lang": "en",
"value": "Fresenius Kabi has created new versions to address these vulnerabilities:\n\u2022\tLink+ v3.0 (D16 or later)\n\u2022\tVSS v1.0.3 (or later)\n\u2022\tAgilia Connect Pumps Wifi Module (D29 or later)\n\u2022\tAgilia Connect Partner v3.3.2 (or later) \nFresenius Kabi has initiated communication on this topic in April 2021 with customers to inform them about availability of the new versions in corresponding countries. Contact Fresenius Kabi online or by phone at 1-800-333-6925 for more information on updating to the newest version.\nFresenius Kabi also identified that early Link+ devices (approximatively 1200 devices) would need hardware change to support D16 or later firmware. Until those devices can be replaced in customers\u2019 installation, Fresenius Kabi recommends users to rely on CISA recommendation. \n"
}
],
"source": {
"advisory": "ICSMA-21-355-01",
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:\n\u2022\tMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\n\u2022\tLocate control system networks and remote devices behind firewalls and isolate them from the business network.\n\u2022\tWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\n"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-23236",
"datePublished": "2022-01-21T18:17:35.000Z",
"dateReserved": "2021-11-30T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:48:05.390Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-23215 (GCVE-0-2021-23215)
Vulnerability from cvelistv5 – Published: 2021-06-08 00:00 – Updated: 2024-08-03 19:05| URL | Tags |
|---|---|
| https://lists.fedoraproject.org/archives/list/pac… | vendor-advisory |
| https://bugzilla.redhat.com/show_bug.cgi?id=1947586 | |
| https://lists.debian.org/debian-lts-announce/2021… | mailing-list |
| https://www.debian.org/security/2022/dsa-5299 | vendor-advisory |
| https://lists.debian.org/debian-lts-announce/2022… | mailing-list |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T19:05:53.906Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "FEDORA-2021-6af32bfcd2",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/BXFLD4ZAXKAIWO6ZPBCQEEDZB5IG676K/"
},
{
"tags": [
"x_transferred"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1947586"
},
{
"name": "[debian-lts-announce] 20210703 [SECURITY] [DLA 2701-1] openexr security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2021/07/msg00001.html"
},
{
"name": "DSA-5299",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2022/dsa-5299"
},
{
"name": "[debian-lts-announce] 20221211 [SECURITY] [DLA 3236-1] openexr security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00022.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "OpenEXR",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "OpenEXR 3.0.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An integer overflow leading to a heap-buffer overflow was found in the DwaCompressor of OpenEXR in versions before 3.0.1. An attacker could use this flaw to crash an application compiled with OpenEXR."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-12T00:00:00.000Z",
"orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"shortName": "redhat"
},
"references": [
{
"name": "FEDORA-2021-6af32bfcd2",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/BXFLD4ZAXKAIWO6ZPBCQEEDZB5IG676K/"
},
{
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1947586"
},
{
"name": "[debian-lts-announce] 20210703 [SECURITY] [DLA 2701-1] openexr security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2021/07/msg00001.html"
},
{
"name": "DSA-5299",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2022/dsa-5299"
},
{
"name": "[debian-lts-announce] 20221211 [SECURITY] [DLA 3236-1] openexr security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00022.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"assignerShortName": "redhat",
"cveId": "CVE-2021-23215",
"datePublished": "2021-06-08T00:00:00.000Z",
"dateReserved": "2021-04-22T00:00:00.000Z",
"dateUpdated": "2024-08-03T19:05:53.906Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
Design throttling mechanisms into the system architecture. The best protection is to limit the amount of resources that an unauthorized user can cause to be expended. A strong authentication and access control model will help prevent such attacks from occurring in the first place. The login application should be protected against DoS attacks as much as possible. Limiting the database access, perhaps by caching result sets, can help minimize the resources expended. To further limit the potential for a DoS attack, consider tracking the rate of requests received from users and blocking requests that exceed a defined rate threshold.
Mitigation
- Mitigation of resource exhaustion attacks requires that the target system either:
- recognizes the attack and denies that user further access for a given amount of time, or
- uniformly throttles all requests in order to make it more difficult to consume resources more quickly than they can again be freed.
- The first of these solutions is an issue in itself though, since it may allow attackers to prevent the use of the system by a particular valid user. If the attacker impersonates the valid user, they may be able to prevent the user from accessing the server in question.
- The second solution is simply difficult to effectively institute -- and even when properly done, it does not provide a full solution. It simply makes the attack require more resources on the part of the attacker.
Mitigation
Ensure that protocols have specific limits of scale placed on them.
Mitigation
Ensure that all failures in resource allocation place the system into a safe posture.
CAPEC-147: XML Ping of the Death
An attacker initiates a resource depletion attack where a large number of small XML messages are delivered at a sufficiently rapid rate to cause a denial of service or crash of the target. Transactions such as repetitive SOAP transactions can deplete resources faster than a simple flooding attack because of the additional resources used by the SOAP protocol and the resources necessary to process SOAP messages. The transactions used are immaterial as long as they cause resource utilization on the target. In other words, this is a normal flooding attack augmented by using messages that will require extra processing on the target.
CAPEC-227: Sustained Client Engagement
An adversary attempts to deny legitimate users access to a resource by continually engaging a specific resource in an attempt to keep the resource tied up as long as possible. The adversary's primary goal is not to crash or flood the target, which would alert defenders; rather it is to repeatedly perform actions or abuse algorithmic flaws such that a given resource is tied up and not available to a legitimate user. By carefully crafting a requests that keep the resource engaged through what is seemingly benign requests, legitimate users are limited or completely denied access to the resource.
CAPEC-492: Regular Expression Exponential Blowup
An adversary may execute an attack on a program that uses a poor Regular Expression(Regex) implementation by choosing input that results in an extreme situation for the Regex. A typical extreme situation operates at exponential time compared to the input size. This is due to most implementations using a Nondeterministic Finite Automaton(NFA) state machine to be built by the Regex algorithm since NFA allows backtracking and thus more complex regular expressions.