CWE-287
DiscouragedImproper Authentication
Abstraction: Class · Status: Draft
When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct.
5993 vulnerabilities reference this CWE, most recent first.
CVE-2019-13423 (GCVE-0-2019-13423)
Vulnerability from cvelistv5 – Published: 2019-08-23 13:30 – Updated: 2024-08-04 23:49- CWE-287 - Improper Authentication
| URL | Tags |
|---|---|
| https://search-guard.com/cve-advisory/ | x_refsource_MISC |
| https://docs.search-guard.com/6.x-25/changelog-ki… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| floragunn | Search Guard Kibana Plugin |
Affected:
unspecified , < 5.6.8-7
(custom)
Affected: unspecified , < 6.x.y-12 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:49:24.978Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://search-guard.com/cve-advisory/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://docs.search-guard.com/6.x-25/changelog-kibana-6.x-12"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Search Guard Kibana Plugin",
"vendor": "floragunn",
"versions": [
{
"lessThan": "5.6.8-7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThan": "6.x.y-12",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Search Guard Kibana Plugin versions before 5.6.8-7 and before 6.x.y-12 had an issue that an authenticated Kibana user could impersonate as kibanaserver user when providing wrong credentials when all of the following conditions a-c are true: a) Kibana is configured to use Single-Sign-On as authentication method, one of Kerberos, JWT, Proxy, Client certificate. b) The kibanaserver user is configured to use HTTP Basic as the authentication method. c) Search Guard is configured to use an SSO authentication domain and HTTP Basic at the same time"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287: Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-08-23T13:30:26.000Z",
"orgId": "9f311a02-c44f-4938-8530-9219246b8255",
"shortName": "floragunn"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://search-guard.com/cve-advisory/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://docs.search-guard.com/6.x-25/changelog-kibana-6.x-12"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@search-guard.com",
"ID": "CVE-2019-13423",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Search Guard Kibana Plugin",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "5.6.8-7"
},
{
"version_affected": "\u003c",
"version_value": "6.x.y-12"
}
]
}
}
]
},
"vendor_name": "floragunn"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Search Guard Kibana Plugin versions before 5.6.8-7 and before 6.x.y-12 had an issue that an authenticated Kibana user could impersonate as kibanaserver user when providing wrong credentials when all of the following conditions a-c are true: a) Kibana is configured to use Single-Sign-On as authentication method, one of Kerberos, JWT, Proxy, Client certificate. b) The kibanaserver user is configured to use HTTP Basic as the authentication method. c) Search Guard is configured to use an SSO authentication domain and HTTP Basic at the same time"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287: Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://search-guard.com/cve-advisory/",
"refsource": "MISC",
"url": "https://search-guard.com/cve-advisory/"
},
{
"name": "https://docs.search-guard.com/6.x-25/changelog-kibana-6.x-12",
"refsource": "CONFIRM",
"url": "https://docs.search-guard.com/6.x-25/changelog-kibana-6.x-12"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "9f311a02-c44f-4938-8530-9219246b8255",
"assignerShortName": "floragunn",
"cveId": "CVE-2019-13423",
"datePublished": "2019-08-23T13:30:26.000Z",
"dateReserved": "2019-07-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T23:49:24.978Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-12643 (GCVE-0-2019-12643)
Vulnerability from cvelistv5 – Published: 2019-08-28 18:40 – Updated: 2024-11-19 18:58| URL | Tags |
|---|---|
| https://tools.cisco.com/security/center/content/C… | vendor-advisoryx_refsource_CISCO |
| Vendor | Product | Version | |
|---|---|---|---|
| Cisco | Cisco IOS XE Software |
Affected:
unspecified , < 16.09.03
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:24:39.215Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20190828 Cisco REST API Container for IOS XE Software Authentication Bypass Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190828-iosxe-rest-auth-bypass"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2019-12643",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-19T17:21:08.669851Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-19T18:58:42.446Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco IOS XE Software",
"vendor": "Cisco",
"versions": [
{
"lessThan": "16.09.03",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-08-28T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the Cisco REST API virtual service container for Cisco IOS XE Software could allow an unauthenticated, remote attacker to bypass authentication on the managed Cisco IOS XE device. The vulnerability is due to an improper check performed by the area of code that manages the REST API authentication service. An attacker could exploit this vulnerability by submitting malicious HTTP requests to the targeted device. A successful exploit could allow the attacker to obtain the token-id of an authenticated user. This token-id could be used to bypass authentication and execute privileged actions through the interface of the REST API virtual service container on the affected Cisco IOS XE device. The REST API interface is not enabled by default and must be installed and activated separately on IOS XE devices. See the Details section for more information."
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-08-28T18:40:12.000Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20190828 Cisco REST API Container for IOS XE Software Authentication Bypass Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190828-iosxe-rest-auth-bypass"
}
],
"source": {
"advisory": "cisco-sa-20190828-iosxe-rest-auth-bypass",
"defect": [
[
"CSCvn93524",
"CSCvo47376"
]
],
"discovery": "INTERNAL"
},
"title": "Cisco REST API Container for IOS XE Software Authentication Bypass Vulnerability",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"DATE_PUBLIC": "2019-08-28T16:00:00-0700",
"ID": "CVE-2019-12643",
"STATE": "PUBLIC",
"TITLE": "Cisco REST API Container for IOS XE Software Authentication Bypass Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco IOS XE Software",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_value": "16.09.03"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the Cisco REST API virtual service container for Cisco IOS XE Software could allow an unauthenticated, remote attacker to bypass authentication on the managed Cisco IOS XE device. The vulnerability is due to an improper check performed by the area of code that manages the REST API authentication service. An attacker could exploit this vulnerability by submitting malicious HTTP requests to the targeted device. A successful exploit could allow the attacker to obtain the token-id of an authenticated user. This token-id could be used to bypass authentication and execute privileged actions through the interface of the REST API virtual service container on the affected Cisco IOS XE device. The REST API interface is not enabled by default and must be installed and activated separately on IOS XE devices. See the Details section for more information."
}
]
},
"exploit": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"impact": {
"cvss": {
"baseScore": "10.0",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20190828 Cisco REST API Container for IOS XE Software Authentication Bypass Vulnerability",
"refsource": "CISCO",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190828-iosxe-rest-auth-bypass"
}
]
},
"source": {
"advisory": "cisco-sa-20190828-iosxe-rest-auth-bypass",
"defect": [
[
"CSCvn93524",
"CSCvo47376"
]
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2019-12643",
"datePublished": "2019-08-28T18:40:12.837Z",
"dateReserved": "2019-06-04T00:00:00.000Z",
"dateUpdated": "2024-11-19T18:58:42.446Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-12254 (GCVE-0-2019-12254)
Vulnerability from cvelistv5 – Published: 2022-05-06 17:30 – Updated: 2024-09-16 20:22- CWE-287 - Improper Authentication
| URL | Tags |
|---|---|
| https://cert.vde.com/en/advisories/VDE-2019-012/ | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| TECSON | e-litro net |
Affected:
unspecified , < V6.32
(custom)
|
|
| TECSON | LX-Net |
Affected:
unspecified , < V6.32
(custom)
|
|
| TECSON | LX-Q-Net |
Affected:
unspecified , < V6.32
(custom)
|
|
| GOK | SmartBox 4 LAN |
Affected:
unspecified , < V6.3
(custom)
|
|
| GOK | SmartBox 4 LAN PRO |
Affected:
unspecified , < V6.3
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:17:39.190Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2019-012/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "e-litro net",
"vendor": "TECSON",
"versions": [
{
"lessThan": "V6.32",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "LX-Net",
"vendor": "TECSON",
"versions": [
{
"lessThan": "V6.32",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "LX-Q-Net",
"vendor": "TECSON",
"versions": [
{
"lessThan": "V6.32",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "SmartBox 4 LAN",
"vendor": "GOK",
"versions": [
{
"lessThan": "V6.3",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "SmartBox 4 LAN PRO",
"vendor": "GOK",
"versions": [
{
"lessThan": "V6.3",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Maxim Rupp (rupp.it) reported this vulnerability to CERT@VDE."
}
],
"datePublic": "2019-04-06T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "In multiple Tecson Tankspion and GOKs SmartBox 4 products the affected application doesn\u0027t properly restrict access to an endpoint that is responsible for saving settings, to a unauthenticated user with limited access rights. Based on the lack of adequately implemented access-control rules, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to change the application settings without authenticating at all, which violates originally laid ACL rules."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-06T17:30:11.000Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en/advisories/VDE-2019-012/"
}
],
"solutions": [
{
"lang": "en",
"value": "Upgrade to firmware version \u003e 6.32"
}
],
"source": {
"advisory": "VDE-2019-012",
"discovery": "EXTERNAL"
},
"title": "TECSON/GOK: Improper Authentication and Access Control on multiple devices",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2019-04-06T10:00:00.000Z",
"ID": "CVE-2019-12254",
"STATE": "PUBLIC",
"TITLE": "TECSON/GOK: Improper Authentication and Access Control on multiple devices"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "e-litro net",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "V6.32"
}
]
}
},
{
"product_name": "LX-Net",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "V6.32"
}
]
}
},
{
"product_name": "LX-Q-Net",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "V6.32"
}
]
}
}
]
},
"vendor_name": "TECSON"
},
{
"product": {
"product_data": [
{
"product_name": "SmartBox 4 LAN",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "V6.3"
}
]
}
},
{
"product_name": "SmartBox 4 LAN PRO",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "V6.3"
}
]
}
}
]
},
"vendor_name": "GOK"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Maxim Rupp (rupp.it) reported this vulnerability to CERT@VDE."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In multiple Tecson Tankspion and GOKs SmartBox 4 products the affected application doesn\u0027t properly restrict access to an endpoint that is responsible for saving settings, to a unauthenticated user with limited access rights. Based on the lack of adequately implemented access-control rules, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to change the application settings without authenticating at all, which violates originally laid ACL rules."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287 Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en/advisories/VDE-2019-012/",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en/advisories/VDE-2019-012/"
}
]
},
"solution": [
{
"lang": "en",
"value": "Upgrade to firmware version \u003e 6.32"
}
],
"source": {
"advisory": "VDE-2019-012",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2019-12254",
"datePublished": "2022-05-06T17:30:12.071Z",
"dateReserved": "2019-05-21T00:00:00.000Z",
"dateUpdated": "2024-09-16T20:22:12.620Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-11272 (GCVE-0-2019-11272)
Vulnerability from cvelistv5 – Published: 2019-06-26 14:06 – Updated: 2024-09-16 19:25- CWE-287 - Improper Authentication - Generic
| URL | Tags |
|---|---|
| https://pivotal.io/security/cve-2019-11272 | x_refsource_CONFIRM |
| https://lists.debian.org/debian-lts-announce/2019… | mailing-listx_refsource_MLIST |
| Vendor | Product | Version | |
|---|---|---|---|
| Spring | Spring Security |
Affected:
4.2 , < 4.2.13.RELEASE
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:48:09.049Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://pivotal.io/security/cve-2019-11272"
},
{
"name": "[debian-lts-announce] 20190709 [SECURITY] [DLA 1848-1] libspring-security-2.0-java security update",
"tags": [
"mailing-list",
"x_refsource_MLIST",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2019/07/msg00008.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Spring Security",
"vendor": "Spring",
"versions": [
{
"lessThan": "4.2.13.RELEASE",
"status": "affected",
"version": "4.2",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-06-20T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Spring Security, versions 4.2.x up to 4.2.12, and older unsupported versions support plain text passwords using PlaintextPasswordEncoder. If an application using an affected version of Spring Security is leveraging PlaintextPasswordEncoder and a user has a null encoded password, a malicious user (or attacker) can authenticate using a password of \"null\"."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287: Improper Authentication - Generic",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-07-09T08:06:02.000Z",
"orgId": "862b2186-222f-48b9-af87-f1fb7bb26d03",
"shortName": "pivotal"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://pivotal.io/security/cve-2019-11272"
},
{
"name": "[debian-lts-announce] 20190709 [SECURITY] [DLA 1848-1] libspring-security-2.0-java security update",
"tags": [
"mailing-list",
"x_refsource_MLIST"
],
"url": "https://lists.debian.org/debian-lts-announce/2019/07/msg00008.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "PlaintextPasswordEncoder authenticates encoded passwords that are null",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@pivotal.io",
"DATE_PUBLIC": "2019-06-20T20:19:44.000Z",
"ID": "CVE-2019-11272",
"STATE": "PUBLIC",
"TITLE": "PlaintextPasswordEncoder authenticates encoded passwords that are null"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Spring Security",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_name": "4.2",
"version_value": "4.2.13.RELEASE"
}
]
}
}
]
},
"vendor_name": "Spring"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Spring Security, versions 4.2.x up to 4.2.12, and older unsupported versions support plain text passwords using PlaintextPasswordEncoder. If an application using an affected version of Spring Security is leveraging PlaintextPasswordEncoder and a user has a null encoded password, a malicious user (or attacker) can authenticate using a password of \"null\"."
}
]
},
"impact": null,
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287: Improper Authentication - Generic"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://pivotal.io/security/cve-2019-11272",
"refsource": "CONFIRM",
"url": "https://pivotal.io/security/cve-2019-11272"
},
{
"name": "[debian-lts-announce] 20190709 [SECURITY] [DLA 1848-1] libspring-security-2.0-java security update",
"refsource": "MLIST",
"url": "https://lists.debian.org/debian-lts-announce/2019/07/msg00008.html"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "862b2186-222f-48b9-af87-f1fb7bb26d03",
"assignerShortName": "pivotal",
"cveId": "CVE-2019-11272",
"datePublished": "2019-06-26T14:06:15.312Z",
"dateReserved": "2019-04-18T00:00:00.000Z",
"dateUpdated": "2024-09-16T19:25:59.208Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-10966 (GCVE-0-2019-10966)
Vulnerability from cvelistv5 – Published: 2019-07-10 17:52 – Updated: 2024-08-04 22:40- CWE-287 - IMPROPER AUTHENTICATION CWE-287
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/109102 | vdb-entryx_refsource_BID |
| https://www.us-cert.gov/ics/advisories/icsma-19-190-01 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| GE | Aestiva and Aespire |
Affected:
versions 7100
Affected: versions 7900 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:40:15.555Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "109102",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/109102"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsma-19-190-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Aestiva and Aespire",
"vendor": "GE",
"versions": [
{
"status": "affected",
"version": "versions 7100"
},
{
"status": "affected",
"version": "versions 7900"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In GE Aestiva and Aespire versions 7100 and 7900, a vulnerability exists where serial devices are connected via an added unsecured terminal server to a TCP/IP network configuration, which could allow an attacker to remotely modify device configuration and silence alarms."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "IMPROPER AUTHENTICATION CWE-287",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-07-10T17:52:39.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "109102",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/109102"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsma-19-190-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2019-10966",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Aestiva and Aespire",
"version": {
"version_data": [
{
"version_value": "versions 7100"
},
{
"version_value": "versions 7900"
}
]
}
}
]
},
"vendor_name": "GE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In GE Aestiva and Aespire versions 7100 and 7900, a vulnerability exists where serial devices are connected via an added unsecured terminal server to a TCP/IP network configuration, which could allow an attacker to remotely modify device configuration and silence alarms."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER AUTHENTICATION CWE-287"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "109102",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/109102"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsma-19-190-01",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsma-19-190-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2019-10966",
"datePublished": "2019-07-10T17:52:23.000Z",
"dateReserved": "2019-04-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T22:40:15.555Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-10150 (GCVE-0-2019-10150)
Vulnerability from cvelistv5 – Published: 2019-06-12 13:42 – Updated: 2024-08-04 22:10| URL | Tags |
|---|---|
| https://docs.openshift.com/container-platform/3.1… | x_refsource_MISC |
| https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2… | x_refsource_CONFIRM |
| https://access.redhat.com/errata/RHSA-2019:2989 | vendor-advisoryx_refsource_REDHAT |
| https://access.redhat.com/errata/RHSA-2019:3007 | vendor-advisoryx_refsource_REDHAT |
| https://access.redhat.com/errata/RHSA-2019:3143 | vendor-advisoryx_refsource_REDHAT |
| https://access.redhat.com/errata/RHSA-2019:3811 | vendor-advisoryx_refsource_REDHAT |
| Vendor | Product | Version | |
|---|---|---|---|
| redhat | atomic-openshift |
Affected:
3.6.x - 4.0.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:10:10.023Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://docs.openshift.com/container-platform/3.11/dev_guide/builds/build_inputs.html#source-secrets-ssh-key-authentication"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-10150"
},
{
"name": "RHSA-2019:2989",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT",
"x_transferred"
],
"url": "https://access.redhat.com/errata/RHSA-2019:2989"
},
{
"name": "RHSA-2019:3007",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT",
"x_transferred"
],
"url": "https://access.redhat.com/errata/RHSA-2019:3007"
},
{
"name": "RHSA-2019:3143",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT",
"x_transferred"
],
"url": "https://access.redhat.com/errata/RHSA-2019:3143"
},
{
"name": "RHSA-2019:3811",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT",
"x_transferred"
],
"url": "https://access.redhat.com/errata/RHSA-2019:3811"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "atomic-openshift",
"vendor": "redhat",
"versions": [
{
"status": "affected",
"version": "3.6.x - 4.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "It was found that OpenShift Container Platform versions 3.6.x - 4.6.0 does not perform SSH Host Key checking when using ssh key authentication during builds. An attacker, with the ability to redirect network traffic, could use this to alter the resulting build output."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:L",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-07T18:06:33.000Z",
"orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"shortName": "redhat"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://docs.openshift.com/container-platform/3.11/dev_guide/builds/build_inputs.html#source-secrets-ssh-key-authentication"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-10150"
},
{
"name": "RHSA-2019:2989",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT"
],
"url": "https://access.redhat.com/errata/RHSA-2019:2989"
},
{
"name": "RHSA-2019:3007",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT"
],
"url": "https://access.redhat.com/errata/RHSA-2019:3007"
},
{
"name": "RHSA-2019:3143",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT"
],
"url": "https://access.redhat.com/errata/RHSA-2019:3143"
},
{
"name": "RHSA-2019:3811",
"tags": [
"vendor-advisory",
"x_refsource_REDHAT"
],
"url": "https://access.redhat.com/errata/RHSA-2019:3811"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"assignerShortName": "redhat",
"cveId": "CVE-2019-10150",
"datePublished": "2019-06-12T13:42:36.000Z",
"dateReserved": "2019-03-27T00:00:00.000Z",
"dateUpdated": "2024-08-04T22:10:10.023Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6854 (GCVE-0-2019-6854)
Vulnerability from cvelistv5 – Published: 2020-01-06 22:56 – Updated: 2024-08-04 20:31- CWE-287 - Improper Authentication
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | EcoStruxure Geo SCADA Expert (ClearSCADA) with initial releases before 1 January 2019 (see notification for more details) |
Affected:
EcoStruxure Geo SCADA Expert (ClearSCADA) with initial releases before 1 January 2019 (see notification for more details)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.395Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-05/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EcoStruxure Geo SCADA Expert (ClearSCADA) with initial releases before 1 January 2019 (see notification for more details)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "EcoStruxure Geo SCADA Expert (ClearSCADA) with initial releases before 1 January 2019 (see notification for more details)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert (ClearSCADA) -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the file system of that operating system to exploit this vulnerability. Affected versions in current support includes ClearSCADA 2017 R3, ClearSCADA 2017 R2, and ClearSCADA 2017."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287: Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-19T12:10:47.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-05/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6854",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EcoStruxure Geo SCADA Expert (ClearSCADA) with initial releases before 1 January 2019 (see notification for more details)",
"version": {
"version_data": [
{
"version_value": "EcoStruxure Geo SCADA Expert (ClearSCADA) with initial releases before 1 January 2019 (see notification for more details)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert (ClearSCADA) -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the file system of that operating system to exploit this vulnerability. Affected versions in current support includes ClearSCADA 2017 R3, ClearSCADA 2017 R2, and ClearSCADA 2017."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287: Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-05/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-05/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6854",
"datePublished": "2020-01-06T22:56:53.000Z",
"dateReserved": "2019-01-25T00:00:00.000Z",
"dateUpdated": "2024-08-04T20:31:04.395Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6832 (GCVE-0-2019-6832)
Vulnerability from cvelistv5 – Published: 2019-09-17 19:31 – Updated: 2024-08-04 20:31- CWE-287 - Authentication
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | spaceLYnk |
Affected:
all versions before 2.4.0
|
|
| Schneider Electric SE | Wiser for KNX |
Affected:
all versions before 2.4.0 - formerly known as homeLYnk
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.434Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-07/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "spaceLYnk",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions before 2.4.0"
}
]
},
{
"product": "Wiser for KNX",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions before 2.4.0 - formerly known as homeLYnk"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control when an attacker bypasses the authentication."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287: Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-17T19:31:14.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-07/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6832",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "spaceLYnk",
"version": {
"version_data": [
{
"version_value": "all versions before 2.4.0"
}
]
}
},
{
"product_name": "Wiser for KNX",
"version": {
"version_data": [
{
"version_value": "all versions before 2.4.0 - formerly known as homeLYnk"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control when an attacker bypasses the authentication."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287: Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-07/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-07/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6832",
"datePublished": "2019-09-17T19:31:14.000Z",
"dateReserved": "2019-01-25T00:00:00.000Z",
"dateUpdated": "2024-08-04T20:31:04.434Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6814 (GCVE-0-2019-6814)
Vulnerability from cvelistv5 – Published: 2019-05-22 19:38 – Updated: 2024-08-04 20:31- CWE-287 - Improper Authentication
| URL | Tags |
|---|---|
| https://www.se.com/ww/en/download/document/SEVD-2… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | ÊNET55XX Encoder with firmware prior to version 2.1.9.Ê |
Affected:
ÊNET55XX Encoder with firmware prior to version 2.1.9.Ê
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.237Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-134-01/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "\u00caNET55XX Encoder with firmware prior to version 2.1.9.\u00ca",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "\u00caNET55XX Encoder with firmware prior to version 2.1.9.\u00ca"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-287: Improper Authentication vulnerability exists in the NET55XX Encoder with firmware prior to version 2.1.9.7 which could cause impact to confidentiality, integrity, and availability when a remote attacker crafts a malicious request to the encoder webUI."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287: Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-19T12:13:04.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-134-01/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6814",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "\u00caNET55XX Encoder with firmware prior to version 2.1.9.\u00ca",
"version": {
"version_data": [
{
"version_value": "\u00caNET55XX Encoder with firmware prior to version 2.1.9.\u00ca"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-287: Improper Authentication vulnerability exists in the NET55XX Encoder with firmware prior to version 2.1.9.7 which could cause impact to confidentiality, integrity, and availability when a remote attacker crafts a malicious request to the encoder webUI."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287: Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2019-134-01/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2019-134-01/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6814",
"datePublished": "2019-05-22T19:38:32.000Z",
"dateReserved": "2019-01-25T00:00:00.000Z",
"dateUpdated": "2024-08-04T20:31:04.237Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6527 (GCVE-0-2019-6527)
Vulnerability from cvelistv5 – Published: 2019-02-12 17:00 – Updated: 2024-09-17 02:32- CWE-287 - IMPROPER AUTHENTICATION CWE-287
| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| ICS-CERT | PR100088 Modbus gateway |
Affected:
All versions prior to Release R02 (or Software Version 1.1.13166)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:23:21.535Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PR100088 Modbus gateway",
"vendor": "ICS-CERT",
"versions": [
{
"status": "affected",
"version": "All versions prior to Release R02 (or Software Version 1.1.13166)"
}
]
}
],
"datePublic": "2019-02-05T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "IMPROPER AUTHENTICATION CWE-287",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-02-12T16:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2019-02-05T00:00:00",
"ID": "CVE-2019-6527",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PR100088 Modbus gateway",
"version": {
"version_data": [
{
"version_value": "All versions prior to Release R02 (or Software Version 1.1.13166)"
}
]
}
}
]
},
"vendor_name": "ICS-CERT"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) may allow an attacker to be able to change the password for an admin user who is currently or previously logged in, provided the device has not been restarted."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER AUTHENTICATION CWE-287"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2019-6527",
"datePublished": "2019-02-12T17:00:00.000Z",
"dateReserved": "2019-01-22T00:00:00.000Z",
"dateUpdated": "2024-09-17T02:32:35.184Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
Strategy: Libraries or Frameworks
Use an authentication framework or library such as the OWASP ESAPI Authentication feature.
CAPEC-114: Authentication Abuse
An attacker obtains unauthorized access to an application, service or device either through knowledge of the inherent weaknesses of an authentication mechanism, or by exploiting a flaw in the authentication scheme's implementation. In such an attack an authentication mechanism is functioning but a carefully controlled sequence of events causes the mechanism to grant access to the attacker.
CAPEC-115: Authentication Bypass
An attacker gains access to application, service, or device with the privileges of an authorized or privileged user by evading or circumventing an authentication mechanism. The attacker is therefore able to access protected data without authentication ever having taken place.
CAPEC-151: Identity Spoofing
Identity Spoofing refers to the action of assuming (i.e., taking on) the identity of some other entity (human or non-human) and then using that identity to accomplish a goal. An adversary may craft messages that appear to come from a different principle or use stolen / spoofed authentication credentials.
CAPEC-194: Fake the Source of Data
An adversary takes advantage of improper authentication to provide data or services under a falsified identity. The purpose of using the falsified identity may be to prevent traceability of the provided data or to assume the rights granted to another individual. One of the simplest forms of this attack would be the creation of an email message with a modified "From" field in order to appear that the message was sent from someone other than the actual sender. The root of the attack (in this case the email system) fails to properly authenticate the source and this results in the reader incorrectly performing the instructed action. Results of the attack vary depending on the details of the attack, but common results include privilege escalation, obfuscation of other attacks, and data corruption/manipulation.
CAPEC-22: Exploiting Trust in Client
An attack of this type exploits vulnerabilities in client/server communication channel authentication and data integrity. It leverages the implicit trust a server places in the client, or more importantly, that which the server believes is the client. An attacker executes this type of attack by communicating directly with the server where the server believes it is communicating only with a valid client. There are numerous variations of this type of attack.
CAPEC-57: Utilizing REST's Trust in the System Resource to Obtain Sensitive Data
This attack utilizes a REST(REpresentational State Transfer)-style applications' trust in the system resources and environment to obtain sensitive data once SSL is terminated.
CAPEC-593: Session Hijacking
This type of attack involves an adversary that exploits weaknesses in an application's use of sessions in performing authentication. The adversary is able to steal or manipulate an active session and use it to gain unathorized access to the application.
CAPEC-633: Token Impersonation
An adversary exploits a weakness in authentication to create an access token (or equivalent) that impersonates a different entity, and then associates a process/thread to that that impersonated token. This action causes a downstream user to make a decision or take action that is based on the assumed identity, and not the response that blocks the adversary.
CAPEC-650: Upload a Web Shell to a Web Server
By exploiting insufficient permissions, it is possible to upload a web shell to a web server in such a way that it can be executed remotely. This shell can have various capabilities, thereby acting as a "gateway" to the underlying web server. The shell might execute at the higher permission level of the web server, providing the ability the execute malicious code at elevated levels.
CAPEC-94: Adversary in the Middle (AiTM)
An adversary targets the communication between two components (typically client and server), in order to alter or obtain data from transactions. A general approach entails the adversary placing themself within the communication channel between the two components.