CWE-259
AllowedUse of Hard-coded Password
Abstraction: Variant · Status: Draft
The product contains a hard-coded password, which it uses for its own inbound authentication or for outbound communication to external components.
327 vulnerabilities reference this CWE, most recent first.
CVE-2020-12039 (GCVE-0-2020-12039)
Vulnerability from cvelistv5 – Published: 2020-06-29 13:45 – Updated: 2024-08-04 11:48| URL | Tags |
|---|---|
| https://www.us-cert.gov/ics/advisories/icsma-20-170-04 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Baxter Sigma Spectrum Infusion Pumps |
Affected:
Sigma Spectrum v6.x model 35700BAX,Spectrum v8.x model 35700BAX2,Sigma Spectrum v6.x with Wireless Battery Module (WBM) v9,v11,v13,v14,v15,v16,v20D29,v20D30,v20D31,v22D24, Spectrum v8.x w/WBM v17,v20D29,v20D30,v20D31,v22D24,Spectrum WBM v17,v20D29,v20D30,v20D31,v22D24,Spectrum LVP v8.x with WBM v17, v20D29,v20D30,v20D31,and v22D24
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:58.109Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Baxter Sigma Spectrum Infusion Pumps",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Sigma Spectrum v6.x model 35700BAX,Spectrum v8.x model 35700BAX2,Sigma Spectrum v6.x with Wireless Battery Module (WBM) v9,v11,v13,v14,v15,v16,v20D29,v20D30,v20D31,v22D24, Spectrum v8.x w/WBM v17,v20D29,v20D30,v20D31,v22D24,Spectrum WBM v17,v20D29,v20D30,v20D31,v22D24,Spectrum LVP v8.x with WBM v17, v20D29,v20D30,v20D31,and v22D24"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v\u0027s6.x model 35700BAX \u0026 Baxter Spectrum Infusion System v\u0027s8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "CWE-259",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-29T13:45:48.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-12039",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Baxter Sigma Spectrum Infusion Pumps",
"version": {
"version_data": [
{
"version_value": "Sigma Spectrum v6.x model 35700BAX,Spectrum v8.x model 35700BAX2,Sigma Spectrum v6.x with Wireless Battery Module (WBM) v9,v11,v13,v14,v15,v16,v20D29,v20D30,v20D31,v22D24, Spectrum v8.x w/WBM v17,v20D29,v20D30,v20D31,v22D24,Spectrum WBM v17,v20D29,v20D30,v20D31,v22D24,Spectrum LVP v8.x with WBM v17, v20D29,v20D30,v20D31,and v22D24"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v\u0027s6.x model 35700BAX \u0026 Baxter Spectrum Infusion System v\u0027s8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-259"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsma-20-170-04",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-12039",
"datePublished": "2020-06-29T13:45:48.000Z",
"dateReserved": "2020-04-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:48:58.109Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12037 (GCVE-0-2020-12037)
Vulnerability from cvelistv5 – Published: 2020-06-29 13:49 – Updated: 2024-08-04 11:48- CWE-259 - USE OF HARD-CODED PASSWORD CWE-259
| URL | Tags |
|---|---|
| https://www.us-cert.gov/ics/advisories/icsma-20-170-01 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Baxter PrismaFlex and PrisMax |
Affected:
PrismaFlex all versions, PrisMax all versions prior to 3.x
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:57.853Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Baxter PrismaFlex and PrisMax",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "PrismaFlex all versions, PrisMax all versions prior to 3.x"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "USE OF HARD-CODED PASSWORD CWE-259",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-29T13:49:46.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-12037",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Baxter PrismaFlex and PrisMax",
"version": {
"version_data": [
{
"version_value": "PrismaFlex all versions, PrisMax all versions prior to 3.x"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "USE OF HARD-CODED PASSWORD CWE-259"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-12037",
"datePublished": "2020-06-29T13:49:46.000Z",
"dateReserved": "2020-04-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:48:57.853Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12016 (GCVE-0-2020-12016)
Vulnerability from cvelistv5 – Published: 2020-06-29 13:54 – Updated: 2024-08-04 11:48- CWE-259 - USE OF HARD-CODED PASSWORD CWE-259
| URL | Tags |
|---|---|
| https://www.us-cert.gov/ics/advisories/icsma-20-170-01 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Baxter ExactaMix EM 2400 & EM 1200 |
Affected:
ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:57.993Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Baxter ExactaMix EM 2400 \u0026 EM 1200",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Baxter ExactaMix EM 2400 \u0026 EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, including access to execute software or to view/update files, directories, or system configuration. This could allow an attacker with network access to view sensitive data including PHI."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "USE OF HARD-CODED PASSWORD CWE-259",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-29T13:54:50.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-12016",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Baxter ExactaMix EM 2400 \u0026 EM 1200",
"version": {
"version_data": [
{
"version_value": "ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Baxter ExactaMix EM 2400 \u0026 EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, including access to execute software or to view/update files, directories, or system configuration. This could allow an attacker with network access to view sensitive data including PHI."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "USE OF HARD-CODED PASSWORD CWE-259"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-12016",
"datePublished": "2020-06-29T13:54:50.000Z",
"dateReserved": "2020-04-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:48:57.993Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12012 (GCVE-0-2020-12012)
Vulnerability from cvelistv5 – Published: 2020-06-29 13:54 – Updated: 2024-08-04 11:48- CWE-259 - USE OF HARD-CODED PASSWORD CWE-259
| URL | Tags |
|---|---|
| https://www.us-cert.gov/ics/advisories/icsma-20-170-01 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Baxter ExactaMix EM 2400 & EM 1200 |
Affected:
ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:57.903Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Baxter ExactaMix EM 2400 \u0026 EM 1200",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Baxter ExactaMix EM 2400 \u0026 EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13, and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 have hard-coded administrative account credentials for the ExactaMix application. Successful exploitation of this vulnerability may allow an attacker with physical access to gain unauthorized access to view/update system configuration or data. This could impact confidentiality and integrity of the system and risk exposure of sensitive information including PHI."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "USE OF HARD-CODED PASSWORD CWE-259",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-29T13:54:53.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-12012",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Baxter ExactaMix EM 2400 \u0026 EM 1200",
"version": {
"version_data": [
{
"version_value": "ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Baxter ExactaMix EM 2400 \u0026 EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13, and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 have hard-coded administrative account credentials for the ExactaMix application. Successful exploitation of this vulnerability may allow an attacker with physical access to gain unauthorized access to view/update system configuration or data. This could impact confidentiality and integrity of the system and risk exposure of sensitive information including PHI."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "USE OF HARD-CODED PASSWORD CWE-259"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-12012",
"datePublished": "2020-06-29T13:54:53.000Z",
"dateReserved": "2020-04-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T11:48:57.903Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7590 (GCVE-0-2020-7590)
Vulnerability from cvelistv5 – Published: 2020-10-13 15:30 – Updated: 2024-08-04 09:33- CWE-259 - Use of Hard-coded Password
| URL | Tags |
|---|---|
| https://www.siemens-healthineers.com/support-docu… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | DCA Vantage Analyzer |
Affected:
All versions < V4.5 are affected by CVE-2020-7590. In addition, serial numbers < 40000 running software V4.4.0 are also affected by CVE-2020-15797
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.941Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.siemens-healthineers.com/support-documentation/security-advisory"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DCA Vantage Analyzer",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.5 are affected by CVE-2020-7590. In addition, serial numbers \u003c 40000 running software V4.4.0 are also affected by CVE-2020-15797"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in DCA Vantage Analyzer (All versions \u003c V4.5 are affected by CVE-2020-7590. In addition, serial numbers \u003c 40000 running software V4.4.0 are also affected by CVE-2020-15797). Affected devices use a hard-coded password to protect the onboard database. This could allow an attacker to read and or modify the onboard database. Successful exploitation requires direct physical access to the device."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "CWE-259: Use of Hard-coded Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-13T15:30:19.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.siemens-healthineers.com/support-documentation/security-advisory"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7590",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DCA Vantage Analyzer",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.5 are affected by CVE-2020-7590. In addition, serial numbers \u003c 40000 running software V4.4.0 are also affected by CVE-2020-15797"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in DCA Vantage Analyzer (All versions \u003c V4.5 are affected by CVE-2020-7590. In addition, serial numbers \u003c 40000 running software V4.4.0 are also affected by CVE-2020-15797). Affected devices use a hard-coded password to protect the onboard database. This could allow an attacker to read and or modify the onboard database. Successful exploitation requires direct physical access to the device."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-259: Use of Hard-coded Password"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.siemens-healthineers.com/support-documentation/security-advisory",
"refsource": "MISC",
"url": "https://www.siemens-healthineers.com/support-documentation/security-advisory"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-7590",
"datePublished": "2020-10-13T15:30:19.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T09:33:19.941Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5351 (GCVE-0-2020-5351)
Vulnerability from cvelistv5 – Published: 2021-07-28 00:05 – Updated: 2024-09-17 01:31- CWE-259 - Use of Hard-coded Password
| URL | Tags |
|---|---|
| https://www.dell.com/support/security/en-us/detai… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Data Protection Advisor |
Affected:
unspecified , < 6.4, 6.5, 18.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:30:23.412Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/security/en-us/details/542649/DSA-2020-080-Dell-EMC-Data-Protection-Advisor-Hard-Coded-Credential-Vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Data Protection Advisor",
"vendor": "Dell",
"versions": [
{
"lessThan": "6.4, 6.5, 18.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-04-07T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC Data Protection Advisor versions 6.4, 6.5 and 18.1 contain an undocumented account with limited privileges that is protected with a hard-coded password. A remote unauthenticated malicious user with the knowledge of the hard-coded password may login to the system and gain read-only privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "CWE-259: Use of Hard-coded Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-28T00:05:16.000Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/security/en-us/details/542649/DSA-2020-080-Dell-EMC-Data-Protection-Advisor-Hard-Coded-Credential-Vulnerability"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2020-04-07",
"ID": "CVE-2020-5351",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Data Protection Advisor",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "6.4, 6.5, 18.1"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC Data Protection Advisor versions 6.4, 6.5 and 18.1 contain an undocumented account with limited privileges that is protected with a hard-coded password. A remote unauthenticated malicious user with the knowledge of the hard-coded password may login to the system and gain read-only privileges."
}
]
},
"impact": {
"cvss": {
"baseScore": 7.5,
"baseSeverity": "High",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-259: Use of Hard-coded Password"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/security/en-us/details/542649/DSA-2020-080-Dell-EMC-Data-Protection-Advisor-Hard-Coded-Credential-Vulnerability",
"refsource": "MISC",
"url": "https://www.dell.com/support/security/en-us/details/542649/DSA-2020-080-Dell-EMC-Data-Protection-Advisor-Hard-Coded-Credential-Vulnerability"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2020-5351",
"datePublished": "2021-07-28T00:05:16.265Z",
"dateReserved": "2020-01-03T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:31:23.532Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-2499 (GCVE-0-2020-2499)
Vulnerability from cvelistv5 – Published: 2020-12-24 01:38 – Updated: 2024-09-17 03:18| URL | Tags |
|---|---|
| https://www.qnap.com/zh-tw/security-advisory/qsa-20-19 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| QNAP Systems Inc. | QES |
Affected:
unspecified , < 2.1.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T07:09:54.172Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-19"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"platforms": [
"build 20200515"
],
"product": "QES",
"vendor": "QNAP Systems Inc.",
"versions": [
{
"lessThan": "2.1.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Lodestone Security"
}
],
"datePublic": "2020-12-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A hard-coded password vulnerability has been reported to affect earlier versions of QES. If exploited, this vulnerability could allow attackers to log in with a hard-coded password. QNAP has already fixed the issue in QES 2.1.1 Build 20200515 and later."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:C/C:L/I:H/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "CWE-259 Use of Hard-coded Password",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522 Insufficiently Protected Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-31T16:33:28.000Z",
"orgId": "2fd009eb-170a-4625-932b-17a53af1051f",
"shortName": "qnap"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-19"
}
],
"solutions": [
{
"lang": "en",
"value": "QNAP has already fixed the issue in QES 2.1.1 Build 20200515 and later."
}
],
"source": {
"advisory": "QSA-20-19",
"discovery": "EXTERNAL"
},
"title": "Hard-coded Password Vulnerability in QES",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@qnap.com",
"DATE_PUBLIC": "2020-12-23T05:49:00.000Z",
"ID": "CVE-2020-2499",
"STATE": "PUBLIC",
"TITLE": "Hard-coded Password Vulnerability in QES"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "QES",
"version": {
"version_data": [
{
"platform": "build 20200515",
"version_affected": "\u003c",
"version_value": "2.1.1"
}
]
}
}
]
},
"vendor_name": "QNAP Systems Inc."
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Lodestone Security"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A hard-coded password vulnerability has been reported to affect earlier versions of QES. If exploited, this vulnerability could allow attackers to log in with a hard-coded password. QNAP has already fixed the issue in QES 2.1.1 Build 20200515 and later."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:C/C:L/I:H/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-259 Use of Hard-coded Password"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-798 Use of Hard-coded Credentials"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-522 Insufficiently Protected Credentials"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-19",
"refsource": "MISC",
"url": "https://www.qnap.com/zh-tw/security-advisory/qsa-20-19"
}
]
},
"solution": [
{
"lang": "en",
"value": "QNAP has already fixed the issue in QES 2.1.1 Build 20200515 and later."
}
],
"source": {
"advisory": "QSA-20-19",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "2fd009eb-170a-4625-932b-17a53af1051f",
"assignerShortName": "qnap",
"cveId": "CVE-2020-2499",
"datePublished": "2020-12-24T01:38:14.895Z",
"dateReserved": "2019-12-09T00:00:00.000Z",
"dateUpdated": "2024-09-17T03:18:12.926Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-13530 (GCVE-0-2019-13530)
Vulnerability from cvelistv5 – Published: 2019-09-12 19:05 – Updated: 2024-08-04 23:57- CWE-259 - USE OF HARD-CODED PASSWORD CWE-259
| URL | Tags |
|---|---|
| https://www.us-cert.gov/ics/advisories/icsma-19-255-01 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Philips IntelliVue WLAN, portable patient monitors |
Affected:
WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:57:39.229Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsma-19-255-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Philips IntelliVue WLAN, portable patient monitors",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). An attacker can use these credentials to login via ftp and upload a malicious firmware."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "USE OF HARD-CODED PASSWORD CWE-259",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-12T19:05:08.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsma-19-255-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2019-13530",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Philips IntelliVue WLAN, portable patient monitors",
"version": {
"version_data": [
{
"version_value": "WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). An attacker can use these credentials to login via ftp and upload a malicious firmware."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "USE OF HARD-CODED PASSWORD CWE-259"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsma-19-255-01",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsma-19-255-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2019-13530",
"datePublished": "2019-09-12T19:05:08.000Z",
"dateReserved": "2019-07-11T00:00:00.000Z",
"dateUpdated": "2024-08-04T23:57:39.229Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-10881 (GCVE-0-2019-10881)
Vulnerability from cvelistv5 – Published: 2021-04-13 20:58 – Updated: 2024-08-04 22:32- CWE-259 - Use of Hard-coded Password
| URL | Tags |
|---|---|
| https://airbus-seclab.github.io/ | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| XEROX | AltaLink B8045/B8055/B8065/B8075/B8090 |
Affected:
n/a
|
|
| XEROX | AltaLink C8030/C8035/C8045/C8055/C8070 |
Affected:
n/a
|
|
| XEROX | WorkCentre 3655 |
Affected:
n/a
|
|
| XEROX | WorkCentre 5845/5855/5865/5875/5890 |
Affected:
n/a
|
|
| XEROX | WorkCentre 5945/5955 |
Affected:
n/a
|
|
| XEROX | WorkCentre 6655 |
Affected:
n/a
|
|
| XEROX | WorkCentre 7220/7225 |
Affected:
n/a
|
|
| XEROX | WorkCentre 7830/7835/7845/7855 |
Affected:
n/a
|
|
| XEROX | WorkCentre 7970 |
Affected:
n/a
|
|
| XEROX | WorkCentre EC7836/EC7856 |
Affected:
n/a
|
|
| XEROX | ColorQube 9301/9302/9303 |
Affected:
n/a
|
|
| XEROX | ColorQube 8700/8900 |
Affected:
n/a
|
|
| XEROX | WorkCentre 6400 |
Affected:
n/a
|
|
| XEROX | Phaser 6700 |
Affected:
n/a
|
|
| XEROX | Phaser 7800 |
Affected:
n/a
|
|
| XEROX | WorkCentre 5735/5740/5745/5755/5765/5775/5790 |
Affected:
n/a
|
|
| XEROX | WorkCentre 7525/7530/7535/7545/7556 |
Affected:
n/a
|
|
| XEROX | WorkCentre 7755/7765/7775 |
Affected:
n/a
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T22:32:02.132Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://airbus-seclab.github.io/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AltaLink B8045/B8055/B8065/B8075/B8090",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
},
{
"product": "AltaLink C8030/C8035/C8045/C8055/C8070",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
},
{
"product": "WorkCentre 3655",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
},
{
"product": "WorkCentre 5845/5855/5865/5875/5890",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
},
{
"product": "WorkCentre 5945/5955",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
},
{
"product": "WorkCentre 6655",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
},
{
"product": "WorkCentre 7220/7225",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
},
{
"product": "WorkCentre 7830/7835/7845/7855",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
},
{
"product": "WorkCentre 7970",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
},
{
"product": "WorkCentre EC7836/EC7856",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
},
{
"product": "ColorQube 9301/9302/9303",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
},
{
"product": "ColorQube 8700/8900",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
},
{
"product": "WorkCentre 6400",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
},
{
"product": "Phaser 6700",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
},
{
"product": "Phaser 7800",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
},
{
"product": "WorkCentre 5735/5740/5745/5755/5765/5775/5790",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
},
{
"product": "WorkCentre 7525/7530/7535/7545/7556",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
},
{
"product": "WorkCentre 7755/7765/7775",
"vendor": "XEROX",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Rapha\u00ebl Rigo from the Airbus Security Lab"
}
],
"descriptions": [
{
"lang": "en",
"value": "Xerox AltaLink B8045/B8055/B8065/B8075/B8090, AltaLink C8030/C8035/C8045/C8055/C8070 with software releases before 103.xxx.030.32000 includes two accounts with weak hard-coded passwords which can be exploited and allow unauthorized access which cannot be disabled."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "CWE-259 Use of Hard-coded Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-13T20:58:01.000Z",
"orgId": "24a3c815-5f22-4d74-967a-30958d6466f4",
"shortName": "airbus"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://airbus-seclab.github.io/"
}
],
"solutions": [
{
"lang": "en",
"value": "No fix available for now."
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Default hidden Privileged Account Vulnerability in multiple XEROX devices",
"workarounds": [
{
"lang": "en",
"value": "There no known workaround for now available."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.6"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@airbus.com",
"ID": "CVE-2019-10881",
"STATE": "PUBLIC",
"TITLE": "Default hidden Privileged Account Vulnerability in multiple XEROX devices"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AltaLink B8045/B8055/B8065/B8075/B8090",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
},
{
"product_name": "AltaLink C8030/C8035/C8045/C8055/C8070",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
},
{
"product_name": "WorkCentre 3655",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
},
{
"product_name": "WorkCentre 5845/5855/5865/5875/5890",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
},
{
"product_name": "WorkCentre 5945/5955",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
},
{
"product_name": "WorkCentre 6655",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
},
{
"product_name": "WorkCentre 7220/7225",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
},
{
"product_name": "WorkCentre 7830/7835/7845/7855",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
},
{
"product_name": "WorkCentre 7970",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
},
{
"product_name": "WorkCentre EC7836/EC7856",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
},
{
"product_name": "ColorQube 9301/9302/9303",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
},
{
"product_name": "ColorQube 8700/8900",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
},
{
"product_name": "WorkCentre 6400",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
},
{
"product_name": "Phaser 6700",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
},
{
"product_name": "Phaser 7800",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
},
{
"product_name": "WorkCentre 5735/5740/5745/5755/5765/5775/5790",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
},
{
"product_name": "WorkCentre 7525/7530/7535/7545/7556",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
},
{
"product_name": "WorkCentre 7755/7765/7775",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "XEROX"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Rapha\u00ebl Rigo from the Airbus Security Lab"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Xerox AltaLink B8045/B8055/B8065/B8075/B8090, AltaLink C8030/C8035/C8045/C8055/C8070 with software releases before 103.xxx.030.32000 includes two accounts with weak hard-coded passwords which can be exploited and allow unauthorized access which cannot be disabled."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.6"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-259 Use of Hard-coded Password"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://airbus-seclab.github.io/",
"refsource": "MISC",
"url": "https://airbus-seclab.github.io/"
}
]
},
"solution": [
{
"lang": "en",
"value": "No fix available for now."
}
],
"source": {
"discovery": "INTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "There no known workaround for now available."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "24a3c815-5f22-4d74-967a-30958d6466f4",
"assignerShortName": "airbus",
"cveId": "CVE-2019-10881",
"datePublished": "2021-04-13T20:58:01.000Z",
"dateReserved": "2019-04-05T00:00:00.000Z",
"dateUpdated": "2024-08-04T22:32:02.132Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3908 (GCVE-0-2019-3908)
Vulnerability from cvelistv5 – Published: 2019-01-18 18:00 – Updated: 2024-08-04 19:26- CWE-259 - Hard-coded Password
| URL | Tags |
|---|---|
| https://www.tenable.com/security/research/tra-2019-01 | x_refsource_MISC |
| http://www.securityfocus.com/bid/106552 | vdb-entryx_refsource_BID |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Premisys Identicard 3.1.190 |
Affected:
Premisys Identicard 3.1.190
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:26.712Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-01"
},
{
"name": "106552",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/106552"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Premisys Identicard 3.1.190",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Premisys Identicard 3.1.190"
}
]
}
],
"datePublic": "2019-01-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Premisys Identicard version 3.1.190 stores backup files as encrypted zip files. The password to the zip is hard-coded and unchangeable. An attacker with access to these backups can decrypt them and obtain sensitive data."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "CWE-259 Hard-coded Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-01-19T10:57:02.000Z",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-01"
},
{
"name": "106552",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/106552"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3908",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Premisys Identicard 3.1.190",
"version": {
"version_data": [
{
"version_value": "Premisys Identicard 3.1.190"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Premisys Identicard version 3.1.190 stores backup files as encrypted zip files. The password to the zip is hard-coded and unchangeable. An attacker with access to these backups can decrypt them and obtain sensitive data."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-259 Hard-coded Password"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-01",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-01"
},
{
"name": "106552",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/106552"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3908",
"datePublished": "2019-01-18T18:00:00.000Z",
"dateReserved": "2019-01-03T00:00:00.000Z",
"dateUpdated": "2024-08-04T19:26:26.712Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
For outbound authentication: store passwords outside of the code in a strongly-protected, encrypted configuration file or database that is protected from access by all outsiders, including other local users on the same system. Properly protect the key (CWE-320). If you cannot use encryption to protect the file, then make sure that the permissions are as restrictive as possible.
Mitigation
For inbound authentication: Rather than hard-code a default username and password for first time logins, utilize a "first login" mode that requires the user to enter a unique strong password.
Mitigation
Perform access control checks and limit which entities can access the feature that requires the hard-coded password. For example, a feature might only be enabled through the system console instead of through a network connection.
Mitigation
- For inbound authentication: apply strong one-way hashes to your passwords and store those hashes in a configuration file or database with appropriate access control. That way, theft of the file/database still requires the attacker to try to crack the password. When receiving an incoming password during authentication, take the hash of the password and compare it to the hash that you have saved.
- Use randomly assigned salts for each separate hash that you generate. This increases the amount of computation that an attacker needs to conduct a brute-force attack, possibly limiting the effectiveness of the rainbow table method.
Mitigation
For front-end to back-end connections: Three solutions are possible, although none are complete.
No CAPEC attack patterns related to this CWE.