Common Weakness Enumeration

CWE-190

Allowed

Integer Overflow or Wraparound

Abstraction: Base · Status: Stable

The product performs a calculation that can produce an integer overflow or wraparound when the logic assumes that the resulting value will always be larger than the original value. This occurs when an integer value is incremented to a value that is too large to store in the associated representation. When this occurs, the value may become a very small or negative number.

3867 vulnerabilities reference this CWE, most recent first.

CVE-2022-0185 (GCVE-0-2022-0185)

Vulnerability from cvelistv5 – Published: 2022-02-11 17:40 – Updated: 2025-10-21 23:15
VLAI
Summary
A heap-based buffer overflow flaw was found in the way the legacy_parse_param function in the Filesystem Context functionality of the Linux kernel verified the supplied parameters length. An unprivileged (in case of unprivileged user namespaces enabled, otherwise needs namespaced CAP_SYS_ADMIN privilege) local user able to open a filesystem that does not support the Filesystem Context API (and thus fallbacks to legacy handling) could use this flaw to escalate their privileges on the system.
SSVC
Exploitation: active Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-190 - Integer Overflow or Wraparound CWE-190
Assigner
Impacted products
Vendor Product Version
n/a kernel Affected: 8.4
linux linux_kernel Affected: 8.4
    cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T23:18:42.536Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit/?id=722d94847de2"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Crusaders-of-Rust/CVE-2022-0185"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.openwall.com/lists/oss-security/2022/01/18/7"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.willsroot.io/2022/01/cve-2022-0185.html"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20220225-0003/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "linux_kernel",
            "vendor": "linux",
            "versions": [
              {
                "status": "affected",
                "version": "8.4"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 8.4,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2024-08-21",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-0185"
              },
              "type": "kev"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2022-0185",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-22T12:49:08.646375Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-21T23:15:46.536Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2022-0185"
          }
        ],
        "timeline": [
          {
            "lang": "en",
            "time": "2024-08-21T00:00:00.000Z",
            "value": "CVE-2022-0185 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "kernel",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "8.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A heap-based buffer overflow flaw was found in the way the legacy_parse_param function in the Filesystem Context functionality of the Linux kernel verified the supplied parameters length. An unprivileged (in case of unprivileged user namespaces enabled, otherwise needs namespaced CAP_SYS_ADMIN privilege) local user able to open a filesystem that does not support the Filesystem Context API (and thus fallbacks to legacy handling) could use this flaw to escalate their privileges on the system."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-190",
              "description": "Integer Overflow or Wraparound CWE-190",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-25T09:06:15.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit/?id=722d94847de2"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Crusaders-of-Rust/CVE-2022-0185"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.openwall.com/lists/oss-security/2022/01/18/7"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.willsroot.io/2022/01/cve-2022-0185.html"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220225-0003/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2022-0185",
    "datePublished": "2022-02-11T17:40:57.000Z",
    "dateReserved": "2022-01-11T00:00:00.000Z",
    "dateUpdated": "2025-10-21T23:15:46.536Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-46750 (GCVE-0-2021-46750)

Vulnerability from cvelistv5 – Published: 2025-09-06 16:03 – Updated: 2025-09-08 13:45
VLAI
Summary
Failure to validate the address and size in TEE (Trusted Execution Environment) may allow a malicious x86 attacker to send malformed messages to the graphics mailbox resulting in an overlap of a TMR (Trusted Memory Region) that was previously allocated by the ASP bootloader leading to a potential loss of integrity.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-190 - Integer Overflow or Wraparound
Assigner
AMD
Impacted products
Vendor Product Version
AMD AMD Athlon™ 3000 Series Mobile Processors with Radeon™ Graphics Unaffected: PicassoPI-FP5 1.0.0.E
Create a notification for this product.
AMD AMD Ryzen™ 3000 Series Mobile Processors with Radeon™ Graphics Unaffected: PicassoPI-FP5 1.0.0.E
Create a notification for this product.
AMD AMD Ryzen™ 7035 Series Processors with Radeon™ Graphics Unaffected: RembrandtPI-FP7_0.0.8.0 RC1
Create a notification for this product.
AMD AMD Ryzen™ 4000 Series Mobile Processors with Radeon™ Graphics Unaffected: RenoirPI-FP6 1.0.0.8
Create a notification for this product.
AMD AMD Ryzen™ 6000 Series Processors with Radeon™ Graphics Unaffected: RembrandtPI-FP7_0.0.8.0 RC1
Create a notification for this product.
AMD AMD Ryzen™ 7030 Series Mobile Processors with Radeon™ Graphics Unaffected: CezannePI-FP6 1.0.0.8
Create a notification for this product.
AMD AMD Ryzen™ 5000 Series Mobile Processors with Radeon™ Graphics Unaffected: CezannePI-FP6 1.0.0.8
Create a notification for this product.
AMD AMD Ryzen™ 4000 Series Desktop Processors Unaffected: ComboAM4v2 PI 1.2.0.5
Create a notification for this product.
AMD AMD Ryzen™ Embedded R1000 Series Processors Unaffected: EmbeddedPI-FP5_1.2.0.A
Create a notification for this product.
AMD AMD Ryzen™ Embedded R2000 Series Processors Unaffected: EmbeddedR2KPI-FP5_1.0.0.2
Create a notification for this product.
AMD AMD Ryzen™ Embedded V1000 Series Processors Unaffected: EmbeddedPI-FP5_1.2.0.A
Create a notification for this product.
AMD AMD Ryzen™ Embedded V2000 Series Processors Unaffected: EmbeddedPI-FP6_1.0.0.6
Create a notification for this product.
AMD AMD Ryzen™ Embedded V3000 Series Unaffected: EmbeddedPI-FP7r2_1000
Create a notification for this product.
AMD AMD Radeon™ RX 6000 Series Graphics Products Unaffected: AMD Software: Adrenalin Edition 23.12.1 (23.30.13.01)
Create a notification for this product.
AMD AMD Radeon™ PRO W6000 Series Graphics Products Unaffected: AMD Software: PRO Edition 23.Q4 (23.30.13.03)
Create a notification for this product.
AMD AMD Radeon™ PRO V620 Graphics Products Unaffected: Contact your AMD Customer Engineering representative
Create a notification for this product.
Date Public
2025-09-06 15:42
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-46750",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-08T13:44:54.633621Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-08T13:45:05.234Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "AMD Athlon\u2122 3000 Series Mobile Processors with Radeon\u2122 Graphics",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "PicassoPI-FP5 1.0.0.E"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "AMD Ryzen\u2122 3000 Series Mobile Processors with Radeon\u2122 Graphics",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "PicassoPI-FP5 1.0.0.E"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "AMD Ryzen\u2122 7035 Series Processors with Radeon\u2122 Graphics",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "RembrandtPI-FP7_0.0.8.0 RC1"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "AMD Ryzen\u2122 4000 Series Mobile Processors with Radeon\u2122 Graphics",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "RenoirPI-FP6 1.0.0.8"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "AMD Ryzen\u2122 6000 Series Processors with Radeon\u2122 Graphics",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "RembrandtPI-FP7_0.0.8.0 RC1"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "AMD Ryzen\u2122 7030 Series Mobile Processors with Radeon\u2122 Graphics",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "CezannePI-FP6 1.0.0.8"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "AMD Ryzen\u2122 5000 Series Mobile Processors with Radeon\u2122 Graphics",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "CezannePI-FP6 1.0.0.8"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "AMD Ryzen\u2122 4000 Series Desktop Processors",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "ComboAM4v2 PI 1.2.0.5"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "AMD Ryzen\u2122 Embedded R1000 Series Processors",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "EmbeddedPI-FP5_1.2.0.A"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "AMD Ryzen\u2122 Embedded R2000 Series Processors",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "EmbeddedR2KPI-FP5_1.0.0.2"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "AMD Ryzen\u2122 Embedded V1000 Series Processors",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "EmbeddedPI-FP5_1.2.0.A"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "AMD Ryzen\u2122 Embedded V2000 Series Processors",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "EmbeddedPI-FP6_1.0.0.6"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "AMD Ryzen\u2122 Embedded V3000 Series",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "EmbeddedPI-FP7r2_1000"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "AMD Radeon\u2122 RX 6000 Series Graphics Products",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "AMD Software: Adrenalin Edition 23.12.1 (23.30.13.01)"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "AMD Radeon\u2122 PRO W6000 Series Graphics Products",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "AMD Software: PRO Edition 23.Q4 (23.30.13.03)"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "AMD Radeon\u2122 PRO V620 Graphics Products",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "Contact your AMD Customer Engineering representative"
            }
          ]
        }
      ],
      "datePublic": "2025-09-06T15:42:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Failure to validate the address and size in TEE (Trusted Execution Environment) may allow a malicious x86 attacker to send malformed messages to the graphics mailbox resulting in an overlap of a TMR (Trusted Memory Region) that was previously allocated by the ASP bootloader leading to a potential loss of integrity.\u003cbr\u003e"
            }
          ],
          "value": "Failure to validate the address and size in TEE (Trusted Execution Environment) may allow a malicious x86 attacker to send malformed messages to the graphics mailbox resulting in an overlap of a TMR (Trusted Memory Region) that was previously allocated by the ASP bootloader leading to a potential loss of integrity."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-190",
              "description": "CWE-190  Integer Overflow or Wraparound",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-06T16:03:55.584Z",
        "orgId": "b58fc414-a1e4-4f92-9d70-1add41838648",
        "shortName": "AMD"
      },
      "references": [
        {
          "url": "https://www.amd.com/en/resources/product-security/bulletin/AMD-SB-4012.html"
        },
        {
          "url": "https://www.amd.com/en/resources/product-security/bulletin/AMD-SB-6018.html"
        },
        {
          "url": "https://www.amd.com/en/resources/product-security/bulletin/AMD-SB-5007.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "AMD PSIRT Automation 1.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b58fc414-a1e4-4f92-9d70-1add41838648",
    "assignerShortName": "AMD",
    "cveId": "CVE-2021-46750",
    "datePublished": "2025-09-06T16:03:55.584Z",
    "dateReserved": "2022-03-31T16:50:27.866Z",
    "dateUpdated": "2025-09-08T13:45:05.234Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44711 (GCVE-0-2021-44711)

Vulnerability from cvelistv5 – Published: 2022-01-14 19:05 – Updated: 2024-09-16 16:17
VLAI
Title
Adobe Acrobat Reader DC annotation gestures integer overflow vulnerability
Summary
Acrobat Reader DC version 21.007.20099 (and earlier), 20.004.30017 (and earlier) and 17.011.30204 (and earlier) are affected by an Integer Overflow or Wraparound vulnerability that could result in arbitrary code execution in the context of the current user. Exploitation of this issue requires user interaction in that a victim must open a malicious file.
CWE
  • CWE-190 - Integer Overflow or Wraparound (CWE-190)
Assigner
References
Impacted products
Vendor Product Version
Adobe Acrobat Reader Affected: unspecified , ≤ 21.007.20099 (custom)
Affected: unspecified , ≤ 20.004.30017 (custom)
Affected: unspecified , ≤ 17.011.30204 (custom)
Affected: unspecified , ≤ None (custom)
Create a notification for this product.
Date Public
2022-01-11 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:17.019Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://helpx.adobe.com/security/products/acrobat/apsb22-01.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Acrobat Reader",
          "vendor": "Adobe",
          "versions": [
            {
              "lessThanOrEqual": "21.007.20099",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "20.004.30017",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "17.011.30204",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "None",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-01-11T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Acrobat Reader DC version 21.007.20099 (and earlier), 20.004.30017 (and earlier) and 17.011.30204 (and earlier) are affected by an Integer Overflow or Wraparound vulnerability that could result in arbitrary code execution in the context of the current user. Exploitation of this issue requires user interaction in that a victim must open a malicious file."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-190",
              "description": "Integer Overflow or Wraparound (CWE-190)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-14T19:05:14.000Z",
        "orgId": "078d4453-3bcd-4900-85e6-15281da43538",
        "shortName": "adobe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://helpx.adobe.com/security/products/acrobat/apsb22-01.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Adobe Acrobat Reader DC annotation gestures integer overflow vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@adobe.com",
          "DATE_PUBLIC": "2022-01-11T23:00:00.000Z",
          "ID": "CVE-2021-44711",
          "STATE": "PUBLIC",
          "TITLE": "Adobe Acrobat Reader DC annotation gestures integer overflow vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Acrobat Reader",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "21.007.20099"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_value": "20.004.30017"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_value": "17.011.30204"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_value": "None"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Adobe"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Acrobat Reader DC version 21.007.20099 (and earlier), 20.004.30017 (and earlier) and 17.011.30204 (and earlier) are affected by an Integer Overflow or Wraparound vulnerability that could result in arbitrary code execution in the context of the current user. Exploitation of this issue requires user interaction in that a victim must open a malicious file."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "userInteraction": "Required",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Integer Overflow or Wraparound (CWE-190)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://helpx.adobe.com/security/products/acrobat/apsb22-01.html",
              "refsource": "MISC",
              "url": "https://helpx.adobe.com/security/products/acrobat/apsb22-01.html"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "078d4453-3bcd-4900-85e6-15281da43538",
    "assignerShortName": "adobe",
    "cveId": "CVE-2021-44711",
    "datePublished": "2022-01-14T19:05:14.975Z",
    "dateReserved": "2021-12-07T00:00:00.000Z",
    "dateUpdated": "2024-09-16T16:17:46.197Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-43784 (GCVE-0-2021-43784)

Vulnerability from cvelistv5 – Published: 2021-12-06 00:00 – Updated: 2024-10-15 17:14
VLAI
Title
Overflow in netlink bytemsg length field allows attacker to override netlink-based container configuration
Summary
runc is a CLI tool for spawning and running containers on Linux according to the OCI specification. In runc, netlink is used internally as a serialization system for specifying the relevant container configuration to the `C` portion of the code (responsible for the based namespace setup of containers). In all versions of runc prior to 1.0.3, the encoder did not handle the possibility of an integer overflow in the 16-bit length field for the byte array attribute type, meaning that a large enough malicious byte array attribute could result in the length overflowing and the attribute contents being parsed as netlink messages for container configuration. This vulnerability requires the attacker to have some control over the configuration of the container and would allow the attacker to bypass the namespace restrictions of the container by simply adding their own netlink payload which disables all namespaces. The main users impacted are those who allow untrusted images with untrusted configurations to run on their machines (such as with shared cloud infrastructure). runc version 1.0.3 contains a fix for this bug. As a workaround, one may try disallowing untrusted namespace paths from your container. It should be noted that untrusted namespace paths would allow the attacker to disable namespace protections entirely even in the absence of this bug.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-190 - Integer Overflow or Wraparound
Assigner
Impacted products
Vendor Product Version
opencontainers runc Affected: < 1.0.3
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:03:08.907Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/opencontainers/runc/security/advisories/GHSA-v95c-p5hm-xq8f"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/opencontainers/runc/commit/9c444070ec7bb83995dbc0185da68284da71c554"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/opencontainers/runc/commit/d72d057ba794164c3cce9451a00b72a78b25e1ae"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/opencontainers/runc/commit/f50369af4b571e358f20b139eea52d612eb55eed"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://bugs.chromium.org/p/project-zero/issues/detail?id=2241"
          },
          {
            "name": "[debian-lts-announce] 20211206 [SECURITY] [DLA 2841-1] runc security update",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2021/12/msg00005.html"
          },
          {
            "name": "[debian-lts-announce] 20240219 [SECURITY] [DLA 3735-1] runc security update",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2024/02/msg00005.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-43784",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-15T17:09:32.113665Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-15T17:14:20.240Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "runc",
          "vendor": "opencontainers",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 1.0.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "runc is a CLI tool for spawning and running containers on Linux according to the OCI specification. In runc, netlink is used internally as a serialization system for specifying the relevant container configuration to the `C` portion of the code (responsible for the based namespace setup of containers). In all versions of runc prior to 1.0.3, the encoder did not handle the possibility of an integer overflow in the 16-bit length field for the byte array attribute type, meaning that a large enough malicious byte array attribute could result in the length overflowing and the attribute contents being parsed as netlink messages for container configuration. This vulnerability requires the attacker to have some control over the configuration of the container and would allow the attacker to bypass the namespace restrictions of the container by simply adding their own netlink payload which disables all namespaces. The main users impacted are those who allow untrusted images with untrusted configurations to run on their machines (such as with shared cloud infrastructure). runc version 1.0.3 contains a fix for this bug. As a workaround, one may try disallowing untrusted namespace paths from your container. It should be noted that untrusted namespace paths would allow the attacker to disable namespace protections entirely even in the absence of this bug."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-190",
              "description": "CWE-190: Integer Overflow or Wraparound",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-19T03:06:18.060Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "url": "https://github.com/opencontainers/runc/security/advisories/GHSA-v95c-p5hm-xq8f"
        },
        {
          "url": "https://github.com/opencontainers/runc/commit/9c444070ec7bb83995dbc0185da68284da71c554"
        },
        {
          "url": "https://github.com/opencontainers/runc/commit/d72d057ba794164c3cce9451a00b72a78b25e1ae"
        },
        {
          "url": "https://github.com/opencontainers/runc/commit/f50369af4b571e358f20b139eea52d612eb55eed"
        },
        {
          "url": "https://bugs.chromium.org/p/project-zero/issues/detail?id=2241"
        },
        {
          "name": "[debian-lts-announce] 20211206 [SECURITY] [DLA 2841-1] runc security update",
          "tags": [
            "mailing-list"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2021/12/msg00005.html"
        },
        {
          "name": "[debian-lts-announce] 20240219 [SECURITY] [DLA 3735-1] runc security update",
          "tags": [
            "mailing-list"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2024/02/msg00005.html"
        }
      ],
      "source": {
        "advisory": "GHSA-v95c-p5hm-xq8f",
        "discovery": "UNKNOWN"
      },
      "title": "Overflow in netlink bytemsg length field allows attacker to override netlink-based container configuration"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2021-43784",
    "datePublished": "2021-12-06T00:00:00.000Z",
    "dateReserved": "2021-11-16T00:00:00.000Z",
    "dateUpdated": "2024-10-15T17:14:20.240Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-42019 (GCVE-0-2021-42019)

Vulnerability from cvelistv5 – Published: 2022-03-08 11:31 – Updated: 2025-08-12 11:11
VLAI
Summary
A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969F, RUGGEDCOM M969NC, RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600T, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400, RUGGEDCOM RS400F, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416F, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PF, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000H, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000T, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900F, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GF, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPF, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GF, RUGGEDCOM RS940GNC, RUGGEDCOM RS969, RUGGEDCOM RS969NC, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100F, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100P (32M) V4.X, RUGGEDCOM RSG2100P (32M) V5.X, RUGGEDCOM RSG2100PF, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2100PNC (32M) V4.X, RUGGEDCOM RSG2100PNC (32M) V5.X, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200F, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300F, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PF, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488F, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V4.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. Within a third-party component, the process to allocate partition size fails to check memory boundaries. Therefore, if a large amount is requested by an attacker, due to an integer-wrap around, it could result in a small size being allocated instead.
CWE
  • CWE-190 - Integer Overflow or Wraparound
Assigner
Impacted products
Vendor Product Version
Siemens RUGGEDCOM i800 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM i800NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM i801 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM i801NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM i802 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM i802NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM i803 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM i803NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM M2100 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM M2100F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM M2100NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM M2200 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM M2200F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM M2200NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM M969 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM M969F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM M969NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RMC30 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RMC30NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RMC8388 V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RMC8388 V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RMC8388NC V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RMC8388NC V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RP110 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RP110NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS1600 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS1600F Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS1600FNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS1600NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS1600T Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS1600TNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS400 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS400F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS400NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS401 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS401NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416NCv2 V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416NCv2 V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416P Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416PF Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416PNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416PNCv2 V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416PNCv2 V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416Pv2 V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416Pv2 V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416v2 V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416v2 V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS8000 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS8000A Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS8000ANC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS8000H Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS8000HNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS8000NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS8000T Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS8000TNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900 (32M) V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900 (32M) V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900G Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900G (32M) V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900G (32M) V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900GF Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900GNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900GNC(32M) V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900GNC(32M) V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900GP Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900GPF Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900GPNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900L Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900LNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900M-GETS-C01 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900M-GETS-XX Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900M-STND-C01 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900M-STND-XX Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900MNC-GETS-C01 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900MNC-GETS-XX Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900MNC-STND-XX Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900MNC-STND-XX-C01 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900NC(32M) V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900NC(32M) V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900W Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS910 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS910L Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS910LNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS910NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS910W Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS920L Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS920LNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS920W Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS930L Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS930LNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS930W Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS940G Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS940GF Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS940GNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS969 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS969NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100 (32M) V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100 (32M) V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100NC(32M) V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100NC(32M) V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100P Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100P (32M) V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100P (32M) V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100PF Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100PNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100PNC (32M) V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100PNC (32M) V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2200 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2200F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2200NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2288 V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2288 V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2288NC V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2288NC V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300 V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300 V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300NC V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300NC V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300P V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300P V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300PF Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300PNC V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300PNC V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2488 V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2488 V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2488F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2488NC V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2488NC V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG907R Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG908C Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG909R Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG910C Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG920P V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG920P V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG920PNC V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG920PNC V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSL910 Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSL910NC Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RST2228 Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RST2228P Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RST916C Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RST916P Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:22:25.623Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256353.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i800",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i800NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i801",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i801NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i802",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i802NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i803",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i803NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M2100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M2100F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M2100NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M2200",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M2200F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M2200NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M969",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M969F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M969NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RMC30",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RMC30NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RMC8388 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RMC8388 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RMC8388NC V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RMC8388NC V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RP110",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RP110NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS1600",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS1600F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS1600FNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS1600NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS1600T",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS1600TNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS400",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS400F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS400NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS401",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS401NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416NCv2 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416NCv2 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416PF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416PNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416PNCv2 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416PNCv2 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416Pv2 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416Pv2 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416v2 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416v2 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000A",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000ANC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000H",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000HNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000T",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000TNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900 (32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900 (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900G (32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900G (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900GF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900GNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900GNC(32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900GNC(32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900GP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900GPF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900GPNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900LNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900M-GETS-C01",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900M-GETS-XX",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900M-STND-C01",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900M-STND-XX",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900MNC-GETS-C01",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900MNC-GETS-XX",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900MNC-STND-XX",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900MNC-STND-XX-C01",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900NC(32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900NC(32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900W",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS910",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS910L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS910LNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS910NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS910W",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS920L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS920LNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS920W",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS930L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS930LNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS930W",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS940G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS940GF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS940GNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS969",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS969NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100 (32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100 (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100NC(32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100NC(32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100P (32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100P (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100PF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100PNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100PNC (32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100PNC (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2200",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2200F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2200NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2288 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2288 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2288NC V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2288NC V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300NC V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300NC V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300P V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300P V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300PF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300PNC V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300PNC V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2488 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2488 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2488F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2488NC V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2488NC V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG907R",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG908C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG909R",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG910C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG920P V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG920P V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG920PNC V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG920PNC V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSL910",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSL910NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RST2228",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RST2228P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RST916C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RST916P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969F, RUGGEDCOM M969NC, RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600T, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400, RUGGEDCOM RS400F, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416F, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PF, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000H, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000T, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900F, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GF, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPF, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GF, RUGGEDCOM RS940GNC, RUGGEDCOM RS969, RUGGEDCOM RS969NC, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100F, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100P (32M) V4.X, RUGGEDCOM RSG2100P (32M) V5.X, RUGGEDCOM RSG2100PF, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2100PNC (32M) V4.X, RUGGEDCOM RSG2100PNC (32M) V5.X, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200F, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300F, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PF, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488F, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V4.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. Within a third-party component, the process to allocate partition size fails to check memory boundaries.\r\n\r\nTherefore, if a large amount is requested by an attacker, due to an integer-wrap around, it could result in a small size being allocated instead."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-190",
              "description": "CWE-190: Integer Overflow or Wraparound",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:11:06.363Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256353.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-256353.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-42019",
    "datePublished": "2022-03-08T11:31:18.000Z",
    "dateReserved": "2021-10-06T00:00:00.000Z",
    "dateUpdated": "2025-08-12T11:11:06.363Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-41199 (GCVE-0-2021-41199)

Vulnerability from cvelistv5 – Published: 2021-11-05 19:55 – Updated: 2024-08-04 03:08
VLAI
Title
Overflow/crash in `tf.image.resize` when size is large
Summary
TensorFlow is an open source platform for machine learning. In affected versions if `tf.image.resize` is called with a large input argument then the TensorFlow process will crash due to a `CHECK`-failure caused by an overflow. The number of elements in the output tensor is too much for the `int64_t` type and the overflow is detected via a `CHECK` statement. This aborts the process. The fix will be included in TensorFlow 2.7.0. We will also cherrypick this commit on TensorFlow 2.6.1, TensorFlow 2.5.2, and TensorFlow 2.4.4, as these are also affected and still in supported range.
CWE
  • CWE-190 - Integer Overflow or Wraparound
Assigner
Impacted products
Vendor Product Version
tensorflow tensorflow Affected: >= 2.6.0, < 2.6.1
Affected: >= 2.5.0, < 2.5.2
Affected: < 2.4.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:08:31.400Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/tensorflow/tensorflow/security/advisories/GHSA-5hx2-qx8j-qjqm"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/tensorflow/tensorflow/issues/46914"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/tensorflow/tensorflow/commit/e5272d4204ff5b46136a1ef1204fc00597e21837"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "tensorflow",
          "vendor": "tensorflow",
          "versions": [
            {
              "status": "affected",
              "version": "\u003e= 2.6.0, \u003c 2.6.1"
            },
            {
              "status": "affected",
              "version": "\u003e= 2.5.0, \u003c 2.5.2"
            },
            {
              "status": "affected",
              "version": "\u003c 2.4.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "TensorFlow is an open source platform for machine learning. In affected versions if `tf.image.resize` is called with a large input argument then the TensorFlow process will crash due to a `CHECK`-failure caused by an overflow. The number of elements in the output tensor is too much for the `int64_t` type and the overflow is detected via a `CHECK` statement. This aborts the process. The fix will be included in TensorFlow 2.7.0. We will also cherrypick this commit on TensorFlow 2.6.1, TensorFlow 2.5.2, and TensorFlow 2.4.4, as these are also affected and still in supported range."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-190",
              "description": "CWE-190: Integer Overflow or Wraparound",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-05T19:55:19.000Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/tensorflow/tensorflow/security/advisories/GHSA-5hx2-qx8j-qjqm"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/tensorflow/tensorflow/issues/46914"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/tensorflow/tensorflow/commit/e5272d4204ff5b46136a1ef1204fc00597e21837"
        }
      ],
      "source": {
        "advisory": "GHSA-5hx2-qx8j-qjqm",
        "discovery": "UNKNOWN"
      },
      "title": "Overflow/crash in `tf.image.resize` when size is large",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-advisories@github.com",
          "ID": "CVE-2021-41199",
          "STATE": "PUBLIC",
          "TITLE": "Overflow/crash in `tf.image.resize` when size is large"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "tensorflow",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003e= 2.6.0, \u003c 2.6.1"
                          },
                          {
                            "version_value": "\u003e= 2.5.0, \u003c 2.5.2"
                          },
                          {
                            "version_value": "\u003c 2.4.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "tensorflow"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "TensorFlow is an open source platform for machine learning. In affected versions if `tf.image.resize` is called with a large input argument then the TensorFlow process will crash due to a `CHECK`-failure caused by an overflow. The number of elements in the output tensor is too much for the `int64_t` type and the overflow is detected via a `CHECK` statement. This aborts the process. The fix will be included in TensorFlow 2.7.0. We will also cherrypick this commit on TensorFlow 2.6.1, TensorFlow 2.5.2, and TensorFlow 2.4.4, as these are also affected and still in supported range."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-190: Integer Overflow or Wraparound"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/tensorflow/tensorflow/security/advisories/GHSA-5hx2-qx8j-qjqm",
              "refsource": "CONFIRM",
              "url": "https://github.com/tensorflow/tensorflow/security/advisories/GHSA-5hx2-qx8j-qjqm"
            },
            {
              "name": "https://github.com/tensorflow/tensorflow/issues/46914",
              "refsource": "MISC",
              "url": "https://github.com/tensorflow/tensorflow/issues/46914"
            },
            {
              "name": "https://github.com/tensorflow/tensorflow/commit/e5272d4204ff5b46136a1ef1204fc00597e21837",
              "refsource": "MISC",
              "url": "https://github.com/tensorflow/tensorflow/commit/e5272d4204ff5b46136a1ef1204fc00597e21837"
            }
          ]
        },
        "source": {
          "advisory": "GHSA-5hx2-qx8j-qjqm",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2021-41199",
    "datePublished": "2021-11-05T19:55:19.000Z",
    "dateReserved": "2021-09-15T00:00:00.000Z",
    "dateUpdated": "2024-08-04T03:08:31.400Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-41198 (GCVE-0-2021-41198)

Vulnerability from cvelistv5 – Published: 2021-11-05 19:55 – Updated: 2024-08-04 03:08
VLAI
Title
Overflow/crash in `tf.tile` when tiling tensor is large
Summary
TensorFlow is an open source platform for machine learning. In affected versions if `tf.tile` is called with a large input argument then the TensorFlow process will crash due to a `CHECK`-failure caused by an overflow. The number of elements in the output tensor is too much for the `int64_t` type and the overflow is detected via a `CHECK` statement. This aborts the process. The fix will be included in TensorFlow 2.7.0. We will also cherrypick this commit on TensorFlow 2.6.1, TensorFlow 2.5.2, and TensorFlow 2.4.4, as these are also affected and still in supported range.
CWE
  • CWE-190 - Integer Overflow or Wraparound
Assigner
Impacted products
Vendor Product Version
tensorflow tensorflow Affected: >= 2.6.0, < 2.6.1
Affected: >= 2.5.0, < 2.5.2
Affected: < 2.4.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:08:31.248Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/tensorflow/tensorflow/security/advisories/GHSA-2p25-55c9-h58q"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/tensorflow/tensorflow/issues/46911"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/tensorflow/tensorflow/commit/9294094df6fea79271778eb7e7ae1bad8b5ef98f"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "tensorflow",
          "vendor": "tensorflow",
          "versions": [
            {
              "status": "affected",
              "version": "\u003e= 2.6.0, \u003c 2.6.1"
            },
            {
              "status": "affected",
              "version": "\u003e= 2.5.0, \u003c 2.5.2"
            },
            {
              "status": "affected",
              "version": "\u003c 2.4.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "TensorFlow is an open source platform for machine learning. In affected versions if `tf.tile` is called with a large input argument then the TensorFlow process will crash due to a `CHECK`-failure caused by an overflow. The number of elements in the output tensor is too much for the `int64_t` type and the overflow is detected via a `CHECK` statement. This aborts the process. The fix will be included in TensorFlow 2.7.0. We will also cherrypick this commit on TensorFlow 2.6.1, TensorFlow 2.5.2, and TensorFlow 2.4.4, as these are also affected and still in supported range."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-190",
              "description": "CWE-190: Integer Overflow or Wraparound",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-05T19:55:26.000Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/tensorflow/tensorflow/security/advisories/GHSA-2p25-55c9-h58q"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/tensorflow/tensorflow/issues/46911"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/tensorflow/tensorflow/commit/9294094df6fea79271778eb7e7ae1bad8b5ef98f"
        }
      ],
      "source": {
        "advisory": "GHSA-2p25-55c9-h58q",
        "discovery": "UNKNOWN"
      },
      "title": "Overflow/crash in `tf.tile` when tiling tensor is large",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-advisories@github.com",
          "ID": "CVE-2021-41198",
          "STATE": "PUBLIC",
          "TITLE": "Overflow/crash in `tf.tile` when tiling tensor is large"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "tensorflow",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003e= 2.6.0, \u003c 2.6.1"
                          },
                          {
                            "version_value": "\u003e= 2.5.0, \u003c 2.5.2"
                          },
                          {
                            "version_value": "\u003c 2.4.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "tensorflow"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "TensorFlow is an open source platform for machine learning. In affected versions if `tf.tile` is called with a large input argument then the TensorFlow process will crash due to a `CHECK`-failure caused by an overflow. The number of elements in the output tensor is too much for the `int64_t` type and the overflow is detected via a `CHECK` statement. This aborts the process. The fix will be included in TensorFlow 2.7.0. We will also cherrypick this commit on TensorFlow 2.6.1, TensorFlow 2.5.2, and TensorFlow 2.4.4, as these are also affected and still in supported range."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-190: Integer Overflow or Wraparound"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/tensorflow/tensorflow/security/advisories/GHSA-2p25-55c9-h58q",
              "refsource": "CONFIRM",
              "url": "https://github.com/tensorflow/tensorflow/security/advisories/GHSA-2p25-55c9-h58q"
            },
            {
              "name": "https://github.com/tensorflow/tensorflow/issues/46911",
              "refsource": "MISC",
              "url": "https://github.com/tensorflow/tensorflow/issues/46911"
            },
            {
              "name": "https://github.com/tensorflow/tensorflow/commit/9294094df6fea79271778eb7e7ae1bad8b5ef98f",
              "refsource": "MISC",
              "url": "https://github.com/tensorflow/tensorflow/commit/9294094df6fea79271778eb7e7ae1bad8b5ef98f"
            }
          ]
        },
        "source": {
          "advisory": "GHSA-2p25-55c9-h58q",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2021-41198",
    "datePublished": "2021-11-05T19:55:26.000Z",
    "dateReserved": "2021-09-15T00:00:00.000Z",
    "dateUpdated": "2024-08-04T03:08:31.248Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-41197 (GCVE-0-2021-41197)

Vulnerability from cvelistv5 – Published: 2021-11-05 19:55 – Updated: 2024-08-04 03:08
VLAI
Title
Crashes due to overflow and `CHECK`-fail in ops with large tensor shapes
Summary
TensorFlow is an open source platform for machine learning. In affected versions TensorFlow allows tensor to have a large number of dimensions and each dimension can be as large as desired. However, the total number of elements in a tensor must fit within an `int64_t`. If an overflow occurs, `MultiplyWithoutOverflow` would return a negative result. In the majority of TensorFlow codebase this then results in a `CHECK`-failure. Newer constructs exist which return a `Status` instead of crashing the binary. This is similar to CVE-2021-29584. The fix will be included in TensorFlow 2.7.0. We will also cherrypick this commit on TensorFlow 2.6.1, TensorFlow 2.5.2, and TensorFlow 2.4.4, as these are also affected and still in supported range.
CWE
  • CWE-190 - Integer Overflow or Wraparound
Assigner
Impacted products
Vendor Product Version
tensorflow tensorflow Affected: >= 2.6.0, < 2.6.1
Affected: >= 2.5.0, < 2.5.2
Affected: < 2.4.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:08:31.502Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/tensorflow/tensorflow/security/advisories/GHSA-prcg-wp5q-rv7p"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/tensorflow/tensorflow/issues/46890"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/tensorflow/tensorflow/issues/51908"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/tensorflow/tensorflow/commit/7c1692bd417eb4f9b33ead749a41166d6080af85"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/tensorflow/tensorflow/commit/a871989d7b6c18cdebf2fb4f0e5c5b62fbc19edf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/tensorflow/tensorflow/commit/d81b1351da3e8c884ff836b64458d94e4a157c15"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "tensorflow",
          "vendor": "tensorflow",
          "versions": [
            {
              "status": "affected",
              "version": "\u003e= 2.6.0, \u003c 2.6.1"
            },
            {
              "status": "affected",
              "version": "\u003e= 2.5.0, \u003c 2.5.2"
            },
            {
              "status": "affected",
              "version": "\u003c 2.4.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "TensorFlow is an open source platform for machine learning. In affected versions TensorFlow allows tensor to have a large number of dimensions and each dimension can be as large as desired. However, the total number of elements in a tensor must fit within an `int64_t`. If an overflow occurs, `MultiplyWithoutOverflow` would return a negative result. In the majority of TensorFlow codebase this then results in a `CHECK`-failure. Newer constructs exist which return a `Status` instead of crashing the binary. This is similar to CVE-2021-29584. The fix will be included in TensorFlow 2.7.0. We will also cherrypick this commit on TensorFlow 2.6.1, TensorFlow 2.5.2, and TensorFlow 2.4.4, as these are also affected and still in supported range."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-190",
              "description": "CWE-190: Integer Overflow or Wraparound",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-05T19:55:35.000Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/tensorflow/tensorflow/security/advisories/GHSA-prcg-wp5q-rv7p"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/tensorflow/tensorflow/issues/46890"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/tensorflow/tensorflow/issues/51908"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/tensorflow/tensorflow/commit/7c1692bd417eb4f9b33ead749a41166d6080af85"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/tensorflow/tensorflow/commit/a871989d7b6c18cdebf2fb4f0e5c5b62fbc19edf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/tensorflow/tensorflow/commit/d81b1351da3e8c884ff836b64458d94e4a157c15"
        }
      ],
      "source": {
        "advisory": "GHSA-prcg-wp5q-rv7p",
        "discovery": "UNKNOWN"
      },
      "title": "Crashes due to overflow and `CHECK`-fail in ops with large tensor shapes",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-advisories@github.com",
          "ID": "CVE-2021-41197",
          "STATE": "PUBLIC",
          "TITLE": "Crashes due to overflow and `CHECK`-fail in ops with large tensor shapes"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "tensorflow",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003e= 2.6.0, \u003c 2.6.1"
                          },
                          {
                            "version_value": "\u003e= 2.5.0, \u003c 2.5.2"
                          },
                          {
                            "version_value": "\u003c 2.4.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "tensorflow"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "TensorFlow is an open source platform for machine learning. In affected versions TensorFlow allows tensor to have a large number of dimensions and each dimension can be as large as desired. However, the total number of elements in a tensor must fit within an `int64_t`. If an overflow occurs, `MultiplyWithoutOverflow` would return a negative result. In the majority of TensorFlow codebase this then results in a `CHECK`-failure. Newer constructs exist which return a `Status` instead of crashing the binary. This is similar to CVE-2021-29584. The fix will be included in TensorFlow 2.7.0. We will also cherrypick this commit on TensorFlow 2.6.1, TensorFlow 2.5.2, and TensorFlow 2.4.4, as these are also affected and still in supported range."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-190: Integer Overflow or Wraparound"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/tensorflow/tensorflow/security/advisories/GHSA-prcg-wp5q-rv7p",
              "refsource": "CONFIRM",
              "url": "https://github.com/tensorflow/tensorflow/security/advisories/GHSA-prcg-wp5q-rv7p"
            },
            {
              "name": "https://github.com/tensorflow/tensorflow/issues/46890",
              "refsource": "MISC",
              "url": "https://github.com/tensorflow/tensorflow/issues/46890"
            },
            {
              "name": "https://github.com/tensorflow/tensorflow/issues/51908",
              "refsource": "MISC",
              "url": "https://github.com/tensorflow/tensorflow/issues/51908"
            },
            {
              "name": "https://github.com/tensorflow/tensorflow/commit/7c1692bd417eb4f9b33ead749a41166d6080af85",
              "refsource": "MISC",
              "url": "https://github.com/tensorflow/tensorflow/commit/7c1692bd417eb4f9b33ead749a41166d6080af85"
            },
            {
              "name": "https://github.com/tensorflow/tensorflow/commit/a871989d7b6c18cdebf2fb4f0e5c5b62fbc19edf",
              "refsource": "MISC",
              "url": "https://github.com/tensorflow/tensorflow/commit/a871989d7b6c18cdebf2fb4f0e5c5b62fbc19edf"
            },
            {
              "name": "https://github.com/tensorflow/tensorflow/commit/d81b1351da3e8c884ff836b64458d94e4a157c15",
              "refsource": "MISC",
              "url": "https://github.com/tensorflow/tensorflow/commit/d81b1351da3e8c884ff836b64458d94e4a157c15"
            }
          ]
        },
        "source": {
          "advisory": "GHSA-prcg-wp5q-rv7p",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2021-41197",
    "datePublished": "2021-11-05T19:55:36.000Z",
    "dateReserved": "2021-09-15T00:00:00.000Z",
    "dateUpdated": "2024-08-04T03:08:31.502Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-41195 (GCVE-0-2021-41195)

Vulnerability from cvelistv5 – Published: 2021-11-05 19:50 – Updated: 2024-08-04 03:08
VLAI
Title
Crash in `tf.math.segment_*` operations
Summary
TensorFlow is an open source platform for machine learning. In affected versions the implementation of `tf.math.segment_*` operations results in a `CHECK`-fail related abort (and denial of service) if a segment id in `segment_ids` is large. This is similar to CVE-2021-29584 (and similar other reported vulnerabilities in TensorFlow, localized to specific APIs): the implementation (both on CPU and GPU) computes the output shape using `AddDim`. However, if the number of elements in the tensor overflows an `int64_t` value, `AddDim` results in a `CHECK` failure which provokes a `std::abort`. Instead, code should use `AddDimWithStatus`. The fix will be included in TensorFlow 2.7.0. We will also cherrypick this commit on TensorFlow 2.6.1, TensorFlow 2.5.2, and TensorFlow 2.4.4, as these are also affected and still in supported range.
CWE
  • CWE-190 - Integer Overflow or Wraparound
Assigner
Impacted products
Vendor Product Version
tensorflow tensorflow Affected: >= 2.6.0, < 2.6.1
Affected: >= 2.5.0, < 2.5.2
Affected: < 2.4.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:08:31.297Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/tensorflow/tensorflow/security/advisories/GHSA-cq76-mxrc-vchh"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/tensorflow/tensorflow/issues/46888"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/tensorflow/tensorflow/pull/51733"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/tensorflow/tensorflow/commit/e9c81c1e1a9cd8dd31f4e83676cab61b60658429"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "tensorflow",
          "vendor": "tensorflow",
          "versions": [
            {
              "status": "affected",
              "version": "\u003e= 2.6.0, \u003c 2.6.1"
            },
            {
              "status": "affected",
              "version": "\u003e= 2.5.0, \u003c 2.5.2"
            },
            {
              "status": "affected",
              "version": "\u003c 2.4.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "TensorFlow is an open source platform for machine learning. In affected versions the implementation of `tf.math.segment_*` operations results in a `CHECK`-fail related abort (and denial of service) if a segment id in `segment_ids` is large. This is similar to CVE-2021-29584 (and similar other reported vulnerabilities in TensorFlow, localized to specific APIs): the implementation (both on CPU and GPU) computes the output shape using `AddDim`. However, if the number of elements in the tensor overflows an `int64_t` value, `AddDim` results in a `CHECK` failure which provokes a `std::abort`. Instead, code should use `AddDimWithStatus`. The fix will be included in TensorFlow 2.7.0. We will also cherrypick this commit on TensorFlow 2.6.1, TensorFlow 2.5.2, and TensorFlow 2.4.4, as these are also affected and still in supported range."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-190",
              "description": "CWE-190: Integer Overflow or Wraparound",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-05T19:50:12.000Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/tensorflow/tensorflow/security/advisories/GHSA-cq76-mxrc-vchh"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/tensorflow/tensorflow/issues/46888"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/tensorflow/tensorflow/pull/51733"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/tensorflow/tensorflow/commit/e9c81c1e1a9cd8dd31f4e83676cab61b60658429"
        }
      ],
      "source": {
        "advisory": "GHSA-cq76-mxrc-vchh",
        "discovery": "UNKNOWN"
      },
      "title": "Crash in `tf.math.segment_*` operations",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-advisories@github.com",
          "ID": "CVE-2021-41195",
          "STATE": "PUBLIC",
          "TITLE": "Crash in `tf.math.segment_*` operations"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "tensorflow",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003e= 2.6.0, \u003c 2.6.1"
                          },
                          {
                            "version_value": "\u003e= 2.5.0, \u003c 2.5.2"
                          },
                          {
                            "version_value": "\u003c 2.4.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "tensorflow"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "TensorFlow is an open source platform for machine learning. In affected versions the implementation of `tf.math.segment_*` operations results in a `CHECK`-fail related abort (and denial of service) if a segment id in `segment_ids` is large. This is similar to CVE-2021-29584 (and similar other reported vulnerabilities in TensorFlow, localized to specific APIs): the implementation (both on CPU and GPU) computes the output shape using `AddDim`. However, if the number of elements in the tensor overflows an `int64_t` value, `AddDim` results in a `CHECK` failure which provokes a `std::abort`. Instead, code should use `AddDimWithStatus`. The fix will be included in TensorFlow 2.7.0. We will also cherrypick this commit on TensorFlow 2.6.1, TensorFlow 2.5.2, and TensorFlow 2.4.4, as these are also affected and still in supported range."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-190: Integer Overflow or Wraparound"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/tensorflow/tensorflow/security/advisories/GHSA-cq76-mxrc-vchh",
              "refsource": "CONFIRM",
              "url": "https://github.com/tensorflow/tensorflow/security/advisories/GHSA-cq76-mxrc-vchh"
            },
            {
              "name": "https://github.com/tensorflow/tensorflow/issues/46888",
              "refsource": "MISC",
              "url": "https://github.com/tensorflow/tensorflow/issues/46888"
            },
            {
              "name": "https://github.com/tensorflow/tensorflow/pull/51733",
              "refsource": "MISC",
              "url": "https://github.com/tensorflow/tensorflow/pull/51733"
            },
            {
              "name": "https://github.com/tensorflow/tensorflow/commit/e9c81c1e1a9cd8dd31f4e83676cab61b60658429",
              "refsource": "MISC",
              "url": "https://github.com/tensorflow/tensorflow/commit/e9c81c1e1a9cd8dd31f4e83676cab61b60658429"
            }
          ]
        },
        "source": {
          "advisory": "GHSA-cq76-mxrc-vchh",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2021-41195",
    "datePublished": "2021-11-05T19:50:12.000Z",
    "dateReserved": "2021-09-15T00:00:00.000Z",
    "dateUpdated": "2024-08-04T03:08:31.297Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-41099 (GCVE-0-2021-41099)

Vulnerability from cvelistv5 – Published: 2021-10-04 18:05 – Updated: 2024-08-04 02:59
VLAI
Title
Integer overflow issue with strings in Redis
Summary
Redis is an open source, in-memory database that persists on disk. An integer overflow bug in the underlying string library can be used to corrupt the heap and potentially result with denial of service or remote code execution. The vulnerability involves changing the default proto-max-bulk-len configuration parameter to a very large value and constructing specially crafted network payloads or commands. The problem is fixed in Redis versions 6.2.6, 6.0.16 and 5.0.14. An additional workaround to mitigate the problem without patching the redis-server executable is to prevent users from modifying the proto-max-bulk-len configuration parameter. This can be done using ACL to restrict unprivileged users from using the CONFIG SET command.
CWE
  • CWE-190 - Integer Overflow or Wraparound
  • CWE-680 - Integer Overflow to Buffer Overflow
Assigner
Impacted products
Vendor Product Version
redis redis Affected: < 5.0.14
Affected: >= 6.0.0, < 6.0.16
Affected: >= 6.2.0, 6.2.6
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T02:59:31.395Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/redis/redis/security/advisories/GHSA-j3cr-9h5g-6cph"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/redis/redis/commit/c6ad876774f3cc11e32681ea02a2eead00f2c521"
          },
          {
            "name": "FEDORA-2021-8913c7900c",
            "tags": [
              "vendor-advisory",
              "x_refsource_FEDORA",
              "x_transferred"
            ],
            "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VL5KXFN3ATM7IIM7Q4O4PWTSRGZ5744Z/"
          },
          {
            "name": "FEDORA-2021-61c487f241",
            "tags": [
              "vendor-advisory",
              "x_refsource_FEDORA",
              "x_transferred"
            ],
            "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/HTYQ5ZF37HNGTZWVNJD3VXP7I6MEEF42/"
          },
          {
            "name": "FEDORA-2021-aa94492a09",
            "tags": [
              "vendor-advisory",
              "x_refsource_FEDORA",
              "x_transferred"
            ],
            "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/WR5WKJWXD4D6S3DJCZ56V74ESLTDQRAB/"
          },
          {
            "name": "DSA-5001",
            "tags": [
              "vendor-advisory",
              "x_refsource_DEBIAN",
              "x_transferred"
            ],
            "url": "https://www.debian.org/security/2021/dsa-5001"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20211104-0003/"
          },
          {
            "name": "GLSA-202209-17",
            "tags": [
              "vendor-advisory",
              "x_refsource_GENTOO",
              "x_transferred"
            ],
            "url": "https://security.gentoo.org/glsa/202209-17"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "redis",
          "vendor": "redis",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 5.0.14"
            },
            {
              "status": "affected",
              "version": "\u003e= 6.0.0, \u003c 6.0.16"
            },
            {
              "status": "affected",
              "version": "\u003e= 6.2.0, 6.2.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Redis is an open source, in-memory database that persists on disk. An integer overflow bug in the underlying string library can be used to corrupt the heap and potentially result with denial of service or remote code execution. The vulnerability involves changing the default proto-max-bulk-len configuration parameter to a very large value and constructing specially crafted network payloads or commands. The problem is fixed in Redis versions 6.2.6, 6.0.16 and 5.0.14. An additional workaround to mitigate the problem without patching the redis-server executable is to prevent users from modifying the proto-max-bulk-len configuration parameter. This can be done using ACL to restrict unprivileged users from using the CONFIG SET command."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-190",
              "description": "CWE-190: Integer Overflow or Wraparound",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-680",
              "description": "CWE-680: Integer Overflow to Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-09-29T16:07:43.000Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/redis/redis/security/advisories/GHSA-j3cr-9h5g-6cph"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/redis/redis/commit/c6ad876774f3cc11e32681ea02a2eead00f2c521"
        },
        {
          "name": "FEDORA-2021-8913c7900c",
          "tags": [
            "vendor-advisory",
            "x_refsource_FEDORA"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VL5KXFN3ATM7IIM7Q4O4PWTSRGZ5744Z/"
        },
        {
          "name": "FEDORA-2021-61c487f241",
          "tags": [
            "vendor-advisory",
            "x_refsource_FEDORA"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/HTYQ5ZF37HNGTZWVNJD3VXP7I6MEEF42/"
        },
        {
          "name": "FEDORA-2021-aa94492a09",
          "tags": [
            "vendor-advisory",
            "x_refsource_FEDORA"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/WR5WKJWXD4D6S3DJCZ56V74ESLTDQRAB/"
        },
        {
          "name": "DSA-5001",
          "tags": [
            "vendor-advisory",
            "x_refsource_DEBIAN"
          ],
          "url": "https://www.debian.org/security/2021/dsa-5001"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20211104-0003/"
        },
        {
          "name": "GLSA-202209-17",
          "tags": [
            "vendor-advisory",
            "x_refsource_GENTOO"
          ],
          "url": "https://security.gentoo.org/glsa/202209-17"
        }
      ],
      "source": {
        "advisory": "GHSA-j3cr-9h5g-6cph",
        "discovery": "UNKNOWN"
      },
      "title": "Integer overflow issue with strings in Redis",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-advisories@github.com",
          "ID": "CVE-2021-41099",
          "STATE": "PUBLIC",
          "TITLE": "Integer overflow issue with strings in Redis"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "redis",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c 5.0.14"
                          },
                          {
                            "version_value": "\u003e= 6.0.0, \u003c 6.0.16"
                          },
                          {
                            "version_value": "\u003e= 6.2.0, 6.2.6"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "redis"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Redis is an open source, in-memory database that persists on disk. An integer overflow bug in the underlying string library can be used to corrupt the heap and potentially result with denial of service or remote code execution. The vulnerability involves changing the default proto-max-bulk-len configuration parameter to a very large value and constructing specially crafted network payloads or commands. The problem is fixed in Redis versions 6.2.6, 6.0.16 and 5.0.14. An additional workaround to mitigate the problem without patching the redis-server executable is to prevent users from modifying the proto-max-bulk-len configuration parameter. This can be done using ACL to restrict unprivileged users from using the CONFIG SET command."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-190: Integer Overflow or Wraparound"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-680: Integer Overflow to Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/redis/redis/security/advisories/GHSA-j3cr-9h5g-6cph",
              "refsource": "CONFIRM",
              "url": "https://github.com/redis/redis/security/advisories/GHSA-j3cr-9h5g-6cph"
            },
            {
              "name": "https://github.com/redis/redis/commit/c6ad876774f3cc11e32681ea02a2eead00f2c521",
              "refsource": "MISC",
              "url": "https://github.com/redis/redis/commit/c6ad876774f3cc11e32681ea02a2eead00f2c521"
            },
            {
              "name": "FEDORA-2021-8913c7900c",
              "refsource": "FEDORA",
              "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/VL5KXFN3ATM7IIM7Q4O4PWTSRGZ5744Z/"
            },
            {
              "name": "FEDORA-2021-61c487f241",
              "refsource": "FEDORA",
              "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/HTYQ5ZF37HNGTZWVNJD3VXP7I6MEEF42/"
            },
            {
              "name": "FEDORA-2021-aa94492a09",
              "refsource": "FEDORA",
              "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/WR5WKJWXD4D6S3DJCZ56V74ESLTDQRAB/"
            },
            {
              "name": "DSA-5001",
              "refsource": "DEBIAN",
              "url": "https://www.debian.org/security/2021/dsa-5001"
            },
            {
              "name": "https://www.oracle.com/security-alerts/cpuapr2022.html",
              "refsource": "MISC",
              "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20211104-0003/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20211104-0003/"
            },
            {
              "name": "GLSA-202209-17",
              "refsource": "GENTOO",
              "url": "https://security.gentoo.org/glsa/202209-17"
            }
          ]
        },
        "source": {
          "advisory": "GHSA-j3cr-9h5g-6cph",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2021-41099",
    "datePublished": "2021-10-04T18:05:11.000Z",
    "dateReserved": "2021-09-15T00:00:00.000Z",
    "dateUpdated": "2024-08-04T02:59:31.395Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation
Requirements

Ensure that all protocols are strictly defined, such that all out-of-bounds behavior can be identified simply, and require strict conformance to the protocol.

Mitigation MIT-3
Requirements

Strategy: Language Selection

  • Use a language that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid.
  • If possible, choose a language or compiler that performs automatic bounds checking.
Mitigation MIT-4
Architecture and Design

Strategy: Libraries or Frameworks

  • Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid [REF-1482].
  • Use libraries or frameworks that make it easier to handle numbers without unexpected consequences.
  • Examples include safe integer handling packages such as SafeInt (C++) or IntegerLib (C or C++). [REF-106]
Mitigation MIT-8
Implementation

Strategy: Input Validation

  • Perform input validation on any numeric input by ensuring that it is within the expected range. Enforce that the input meets both the minimum and maximum requirements for the expected range.
  • Use unsigned integers where possible. This makes it easier to perform validation for integer overflows. When signed integers are required, ensure that the range check includes minimum values as well as maximum values.
Mitigation MIT-36
Implementation
  • Understand the programming language's underlying representation and how it interacts with numeric calculation (CWE-681). Pay close attention to byte size discrepancies, precision, signed/unsigned distinctions, truncation, conversion and casting between types, "not-a-number" calculations, and how the language handles numbers that are too large or too small for its underlying representation. [REF-7]
  • Also be careful to account for 32-bit, 64-bit, and other potential differences that may affect the numeric representation.
Mitigation MIT-15
Architecture and Design

For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.

Mitigation MIT-26
Implementation

Strategy: Compilation or Build Hardening

Examine compiler warnings closely and eliminate problems with potential security implications, such as signed / unsigned mismatch in memory operations, or use of uninitialized variables. Even if the weakness is rarely exploitable, a single failure may lead to the compromise of the entire system.

CAPEC-92: Forced Integer Overflow

This attack forces an integer variable to go out of range. The integer variable is often used as an offset such as size of memory allocation or similarly. The attacker would typically control the value of such variable and try to get it out of range. For instance the integer in question is incremented past the maximum possible value, it may wrap to become a very small, or negative number, therefore providing a very incorrect value which can lead to unexpected behavior. At worst the attacker can execute arbitrary code.