Common Weakness Enumeration
CWE-121
AllowedStack-based Buffer Overflow
Abstraction: Variant · Status: Draft
A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).
5215 vulnerabilities reference this CWE, most recent first.
CVE-2024-3906 (GCVE-0-2024-3906)
Vulnerability from cvelistv5 – Published: 2024-04-17 10:31 – Updated: 2024-08-01 20:26
VLAI
EPSS
VEX
Title
Tenda AC500 QuickIndex formQuickIndex stack-based overflow
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.261142 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.261142 | signaturepermissions-required |
| https://vuldb.com/?submit.313801 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ac500",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.9(1307)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3906",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-23T18:24:41.411561Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:33:20.174Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.104Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-261142 | Tenda AC500 QuickIndex formQuickIndex stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.261142"
},
{
"name": "VDB-261142 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.261142"
},
{
"name": "Submit #313801 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.313801"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formQuickIndex.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC500",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.9(1307)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_tu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda AC500 2.0.1.9(1307) wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Betroffen ist die Funktion formQuickIndex der Datei /goform/QuickIndex. Mit der Manipulation des Arguments PPPOEPassword mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-17T10:31:05.641Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-261142 | Tenda AC500 QuickIndex formQuickIndex stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.261142"
},
{
"name": "VDB-261142 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.261142"
},
{
"name": "Submit #313801 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.313801"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formQuickIndex.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-17T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-17T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-17T07:52:55.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC500 QuickIndex formQuickIndex stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3906",
"datePublished": "2024-04-17T10:31:05.641Z",
"dateReserved": "2024-04-17T05:42:39.118Z",
"dateUpdated": "2024-08-01T20:26:57.104Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3905 (GCVE-0-2024-3905)
Vulnerability from cvelistv5 – Published: 2024-04-17 10:31 – Updated: 2024-08-01 20:26
VLAI
EPSS
VEX
Title
Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.261141 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.261141 | signaturepermissions-required |
| https://vuldb.com/?submit.313790 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3905",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-29T19:10:05.982005Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:31:03.283Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.134Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-261141 | Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.261141"
},
{
"name": "VDB-261141 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.261141"
},
{
"name": "Submit #313790 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.313790"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/R7WebsSecurityHandler.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AC500",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "2.0.1.9(1307)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Tenda AC500 2.0.1.9(1307) ausgemacht. Sie wurde als kritisch eingestuft. Hiervon betroffen ist die Funktion R7WebsSecurityHandler der Datei /goform/execCommand. Dank Manipulation des Arguments password mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-17T10:31:04.297Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-261141 | Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.261141"
},
{
"name": "VDB-261141 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.261141"
},
{
"name": "Submit #313790 | Tenda AC500 V2.0.1.9(1307) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.313790"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/R7WebsSecurityHandler.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-17T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-17T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-17T07:52:41.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3905",
"datePublished": "2024-04-17T10:31:04.297Z",
"dateReserved": "2024-04-17T05:42:30.657Z",
"dateUpdated": "2024-08-01T20:26:57.134Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3882 (GCVE-0-2024-3882)
Vulnerability from cvelistv5 – Published: 2024-04-16 20:00 – Updated: 2024-08-01 20:26
VLAI
EPSS
VEX
Title
Tenda W30E fromRouteStatic stack-based overflow
Summary
A vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.260916 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.260916 | signaturepermissions-required |
| https://vuldb.com/?submit.312825 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | W30E |
Affected:
1.0.1.25(633)
|
|
| tenda | w30e_firmware |
Affected:
1.0.1.25\(633\)
cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\(633\):*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "w30e_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.1.25\\(633\\)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3882",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T16:18:28.401307Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-10T16:32:20.665Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.138Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-260916 | Tenda W30E fromRouteStatic stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.260916"
},
{
"name": "VDB-260916 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.260916"
},
{
"name": "Submit #312825 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.312825"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/fromRouteStatic.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "W30E",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.1.25(633)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda W30E 1.0.1.25(633) ausgemacht. Hiervon betroffen ist die Funktion fromRouteStatic der Datei /goform/fromRouteStatic. Durch das Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-16T20:00:12.433Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-260916 | Tenda W30E fromRouteStatic stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.260916"
},
{
"name": "VDB-260916 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.260916"
},
{
"name": "Submit #312825 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.312825"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/fromRouteStatic.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-16T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-16T12:55:07.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W30E fromRouteStatic stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3882",
"datePublished": "2024-04-16T20:00:12.433Z",
"dateReserved": "2024-04-16T10:49:48.302Z",
"dateUpdated": "2024-08-01T20:26:57.138Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3881 (GCVE-0-2024-3881)
Vulnerability from cvelistv5 – Published: 2024-04-16 19:31 – Updated: 2024-08-01 20:26
VLAI
EPSS
VEX
Title
Tenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow
Summary
A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.260915 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.260915 | signaturepermissions-required |
| https://vuldb.com/?submit.312824 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "w30e",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.1.25\\/633\\/"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3881",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-18T15:46:58.429046Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-03T15:34:42.267Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:56.424Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-260915 | Tenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.260915"
},
{
"name": "VDB-260915 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.260915"
},
{
"name": "Submit #312824 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.312824"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/frmL7ProtForm.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "W30E",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.1.25(633)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda W30E 1.0.1.25(633) gefunden. Davon betroffen ist die Funktion frmL7PlotForm der Datei /goform/frmL7ProtForm. Mittels Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-16T19:31:04.202Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-260915 | Tenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.260915"
},
{
"name": "VDB-260915 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.260915"
},
{
"name": "Submit #312824 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.312824"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/frmL7ProtForm.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-16T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-16T12:55:05.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3881",
"datePublished": "2024-04-16T19:31:04.202Z",
"dateReserved": "2024-04-16T10:49:45.427Z",
"dateUpdated": "2024-08-01T20:26:56.424Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3879 (GCVE-0-2024-3879)
Vulnerability from cvelistv5 – Published: 2024-04-16 19:00 – Updated: 2024-08-19 18:45
VLAI
EPSS
VEX
Title
Tenda W30E setcfm formSetCfm stack-based overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.260913 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.260913 | signaturepermissions-required |
| https://vuldb.com/?submit.312822 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | W30E |
Affected:
1.0.1.25(633)
|
|
| tenda | w30e_firmware |
Affected:
1.0.1.25\(633\)
cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\(633\):*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:56.983Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-260913 | Tenda W30E setcfm formSetCfm stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.260913"
},
{
"name": "VDB-260913 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.260913"
},
{
"name": "Submit #312822 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.312822"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formSetCfm.md"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "w30e_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.0.1.25\\(633\\)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3879",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-19T17:33:22.591779Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-19T18:45:07.704Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "W30E",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0.1.25(633)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda W30E 1.0.1.25(633) gefunden. Dabei betrifft es die Funktion formSetCfm der Datei /goform/setcfm. Durch Manipulation des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-16T19:00:04.934Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-260913 | Tenda W30E setcfm formSetCfm stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.260913"
},
{
"name": "VDB-260913 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.260913"
},
{
"name": "Submit #312822 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.312822"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formSetCfm.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-16T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-16T12:55:02.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W30E setcfm formSetCfm stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3879",
"datePublished": "2024-04-16T19:00:04.934Z",
"dateReserved": "2024-04-16T10:49:39.590Z",
"dateUpdated": "2024-08-19T18:45:07.704Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3878 (GCVE-0-2024-3878)
Vulnerability from cvelistv5 – Published: 2024-04-16 18:31 – Updated: 2024-08-01 20:26
VLAI
EPSS
VEX
Title
Tenda F1202 webExcptypemanFilter fromwebExcptypemanFilter stack-based overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda F1202 1.2.0.20(408). Affected by this issue is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260912. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.260912 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.260912 | signaturepermissions-required |
| https://vuldb.com/?submit.312821 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | F1202 |
Affected:
1.2.0.20(408)
|
|
| tenda | f1202_firmware |
Affected:
1.2.0.20\(408\)
cpe:2.3:o:tenda:f1202_firmware:1.2.0.20\(408\):*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:f1202_firmware:1.2.0.20\\(408\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "f1202_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.20\\(408\\)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3878",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-03T17:30:20.355023Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-03T21:04:08.719Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.132Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-260912 | Tenda F1202 webExcptypemanFilter fromwebExcptypemanFilter stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.260912"
},
{
"name": "VDB-260912 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.260912"
},
{
"name": "Submit #312821 | Tenda F1202 V1.2.0.20(408) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.312821"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1202/fromwebExcptypemanFilter.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "F1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.20(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda F1202 1.2.0.20(408). Affected by this issue is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260912. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda F1202 1.2.0.20(408) entdeckt. Dies betrifft die Funktion fromwebExcptypemanFilter der Datei /goform/webExcptypemanFilter. Durch die Manipulation des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-16T18:31:05.460Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-260912 | Tenda F1202 webExcptypemanFilter fromwebExcptypemanFilter stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.260912"
},
{
"name": "VDB-260912 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.260912"
},
{
"name": "Submit #312821 | Tenda F1202 V1.2.0.20(408) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.312821"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1202/fromwebExcptypemanFilter.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-16T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-16T12:55:00.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda F1202 webExcptypemanFilter fromwebExcptypemanFilter stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3878",
"datePublished": "2024-04-16T18:31:05.460Z",
"dateReserved": "2024-04-16T10:49:36.850Z",
"dateUpdated": "2024-08-01T20:26:57.132Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3877 (GCVE-0-2024-3877)
Vulnerability from cvelistv5 – Published: 2024-04-16 18:31 – Updated: 2024-08-01 20:26
VLAI
EPSS
VEX
Title
Tenda F1202 fromqossetting stack-based overflow
Summary
A vulnerability classified as critical was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function fromqossetting of the file /goform/fromqossetting. The manipulation of the argument qos leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260911. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.260911 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.260911 | signaturepermissions-required |
| https://vuldb.com/?submit.312820 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | F1202 |
Affected:
1.2.0.20(408)
|
|
| tenda | f1202_firmware |
Affected:
1.2.0.20\(408\)
cpe:2.3:o:tenda:f1202_firmware:1.2.0.20\(408\):*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:f1202_firmware:1.2.0.20\\(408\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "f1202_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.20\\(408\\)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3877",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-24T13:34:45.882178Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:31:22.283Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.129Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-260911 | Tenda F1202 fromqossetting stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.260911"
},
{
"name": "VDB-260911 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.260911"
},
{
"name": "Submit #312820 | Tenda F1202 V1.2.0.20(408) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.312820"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1202/fromqossetting.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "F1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.20(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function fromqossetting of the file /goform/fromqossetting. The manipulation of the argument qos leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260911. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda F1202 1.2.0.20(408) wurde eine kritische Schwachstelle entdeckt. Das betrifft die Funktion fromqossetting der Datei /goform/fromqossetting. Mit der Manipulation des Arguments qos mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-16T18:31:04.090Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-260911 | Tenda F1202 fromqossetting stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.260911"
},
{
"name": "VDB-260911 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.260911"
},
{
"name": "Submit #312820 | Tenda F1202 V1.2.0.20(408) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.312820"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1202/fromqossetting.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-16T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-16T12:54:59.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda F1202 fromqossetting stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3877",
"datePublished": "2024-04-16T18:31:04.090Z",
"dateReserved": "2024-04-16T10:49:33.989Z",
"dateUpdated": "2024-08-01T20:26:57.129Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3876 (GCVE-0-2024-3876)
Vulnerability from cvelistv5 – Published: 2024-04-16 18:00 – Updated: 2024-08-01 20:26
VLAI
EPSS
VEX
Title
Tenda F1202 VirtualSer fromVirtualSer stack-based overflow
Summary
A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.260910 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.260910 | signaturepermissions-required |
| https://vuldb.com/?submit.312818 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | F1202 |
Affected:
1.2.0.20(408)
|
|
| tenda | f1202_firmware |
Affected:
1.2.0.20\(408\)
cpe:2.3:o:tenda:f1202_firmware:1.2.0.20\(408\):*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:f1202_firmware:1.2.0.20\\(408\\):*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "f1202_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.20\\(408\\)"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3876",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-17T18:12:31.936341Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-17T18:15:42.193Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.057Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-260910 | Tenda F1202 VirtualSer fromVirtualSer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.260910"
},
{
"name": "VDB-260910 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.260910"
},
{
"name": "Submit #312818 | Tenda F1202 V1.2.0.20(408) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.312818"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1202/fromVirtualSer.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "F1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.20(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda F1202 1.2.0.20(408) entdeckt. Es betrifft die Funktion fromVirtualSer der Datei /goform/VirtualSer. Dank Manipulation des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-16T18:00:07.035Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-260910 | Tenda F1202 VirtualSer fromVirtualSer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.260910"
},
{
"name": "VDB-260910 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.260910"
},
{
"name": "Submit #312818 | Tenda F1202 V1.2.0.20(408) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.312818"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1202/fromVirtualSer.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-16T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-16T12:54:57.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda F1202 VirtualSer fromVirtualSer stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3876",
"datePublished": "2024-04-16T18:00:07.035Z",
"dateReserved": "2024-04-16T10:49:31.056Z",
"dateUpdated": "2024-08-01T20:26:57.057Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3875 (GCVE-0-2024-3875)
Vulnerability from cvelistv5 – Published: 2024-04-16 18:00 – Updated: 2024-08-01 20:26
VLAI
EPSS
VEX
Title
Tenda F1202 Natlimit fromNatlimit stack-based overflow
Summary
A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.260909 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.260909 | signaturepermissions-required |
| https://vuldb.com/?submit.312817 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3875",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-13T17:12:14.344551Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:33:09.647Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:56.928Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-260909 | Tenda F1202 Natlimit fromNatlimit stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.260909"
},
{
"name": "VDB-260909 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.260909"
},
{
"name": "Submit #312817 | Tenda F1202 V1.2.0.20(408) buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.312817"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1202/fromNatlimit.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "F1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.20(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda F1202 1.2.0.20(408) ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion fromNatlimit der Datei /goform/Natlimit. Dank der Manipulation des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-16T18:00:05.455Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-260909 | Tenda F1202 Natlimit fromNatlimit stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.260909"
},
{
"name": "VDB-260909 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.260909"
},
{
"name": "Submit #312817 | Tenda F1202 V1.2.0.20(408) buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.312817"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/F/F1202/fromNatlimit.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-16T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-16T12:54:56.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda F1202 Natlimit fromNatlimit stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3875",
"datePublished": "2024-04-16T18:00:05.455Z",
"dateReserved": "2024-04-16T10:49:28.093Z",
"dateUpdated": "2024-08-01T20:26:56.928Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3874 (GCVE-0-2024-3874)
Vulnerability from cvelistv5 – Published: 2024-04-16 15:31 – Updated: 2024-08-01 20:26
VLAI
EPSS
VEX
Title
Tenda W20E SetRemoteWebManage formSetRemoteWebManage stack-based overflow
Summary
A vulnerability was found in Tenda W20E 15.11.0.6. It has been declared as critical. This vulnerability affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260908. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Severity
8.8 (High)
8.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://vuldb.com/?id.260908 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.260908 | signaturepermissions-required |
| https://vuldb.com/?submit.312816 | third-party-advisory |
| https://github.com/abcdefg-png/IoT-vulnerable/blo… | exploit |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Tenda | W20E |
Affected:
15.11.0.6
|
|
| tenda | w20e_firmware |
Affected:
15.11.0.6
cpe:2.3:o:tenda:w20e_firmware:15.11.0.6:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:w20e_firmware:15.11.0.6:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "w20e_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.11.0.6"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3874",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-30T19:19:51.539381Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:33:03.647Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.026Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "VDB-260908 | Tenda W20E SetRemoteWebManage formSetRemoteWebManage stack-based overflow",
"tags": [
"vdb-entry",
"technical-description",
"x_transferred"
],
"url": "https://vuldb.com/?id.260908"
},
{
"name": "VDB-260908 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required",
"x_transferred"
],
"url": "https://vuldb.com/?ctiid.260908"
},
{
"name": "Submit #312816 | Tenda W20EV4.0 V15.11.0.6 buffer overflow",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://vuldb.com/?submit.312816"
},
{
"tags": [
"exploit",
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W20E/formSetRemoteWebManage.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "W20E",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.11.0.6"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_mie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda W20E 15.11.0.6. It has been declared as critical. This vulnerability affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260908. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Tenda W20E 15.11.0.6 wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion formSetRemoteWebManage der Datei /goform/SetRemoteWebManage. Durch Beeinflussen des Arguments remoteIP mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-16T15:31:06.633Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-260908 | Tenda W20E SetRemoteWebManage formSetRemoteWebManage stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.260908"
},
{
"name": "VDB-260908 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.260908"
},
{
"name": "Submit #312816 | Tenda W20EV4.0 V15.11.0.6 buffer overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.312816"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W20E/formSetRemoteWebManage.md"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-04-16T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-04-16T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-04-16T12:54:54.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda W20E SetRemoteWebManage formSetRemoteWebManage stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-3874",
"datePublished": "2024-04-16T15:31:06.633Z",
"dateReserved": "2024-04-16T10:49:25.045Z",
"dateUpdated": "2024-08-01T20:26:57.026Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation MIT-10
Operation
Build and Compilation
Strategy: Environment Hardening
- Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
- D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation
Architecture and Design
Use an abstraction library to abstract away risky APIs. Not a complete solution.
Mitigation
Implementation
Implement and perform bounds checking on input.
Mitigation
Implementation
Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.
Mitigation MIT-11
Operation
Build and Compilation
Strategy: Environment Hardening
- Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
- Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
- For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].
No CAPEC attack patterns related to this CWE.