VDE-2026-078
Vulnerability from csaf_frauschersensortechnikgmbh - Published: 2026-08-20 10:00 - Updated: 2026-08-20 10:00A high privileged remote attacker can upload a .php file and then request it directly from /uploads/<filename>.php to achieve arbitrary code execution due to improper file type validation which could result in full system compromise.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
FDS102 2.14.0
Frauscher / Software / FDS / 102
|
cpe:2.3:a:frauscher:fds102:2.14.0:*:*:*:*:*:*:*
|
2.14.0 |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
FDS102 >=2.8.0<=2.13.3
Frauscher / Software / FDS / 102
|
cpe:2.3:a:frauscher:fds102:*:*:*:*:*:*:*:*
|
vers:semver/>=2.8.0|<=2.13.3 |
A high-privileged remote attacker can upload malicious ZIP archive containing directory traversal sequences such as ../ can escape the intended extraction directory and write files to arbitrary locations on the server, potentially achieve arbitrary code execution due to improper validation of archive entry paths before writing files to disk which could result in full system compromise.
A low privileged remote attacker can hijack an active administrative session without needing to know the administrator password by extracting live plaintext session identifiers for authenticated users from downloadable error log archives.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
FDS102 >=2.13.0<=2.13.3
Frauscher / Software / FDS / 102
|
cpe:2.3:a:frauscher:fds102:*:*:*:*:*:*:*:*
|
vers:semver/>=2.13.0|<=2.13.3 |
A low privileged remote attacker with a valid session can submit a request to the user creation functionality exposed through /api/user/add.php to create new accounts with arbitrary role values, including the highest privilege level used by the application.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
FDS102 >=2.11.0<=2.13.3
Frauscher / Software / FDS / 102
|
cpe:2.3:a:frauscher:fds102:*:*:*:*:*:*:*:*
|
vers:semver/>=2.11.0|<=2.13.3 |
An unauthenticated remote attacker in possession of a valid session identifier is able to continue using the session after it should have expired. This increases the risk associated with stolen, leaked, shared, or unattended sessions and may enable unauthorized continued access to the FDS web interface.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
FDS102 >=2.1.0<=2.13.3
Frauscher / Software / FDS / 102
|
cpe:2.3:a:frauscher:fds102:*:*:*:*:*:*:*:*
|
vers:semver/>=2.1.0|<=2.13.3 |
An low privileged remote attacker can cause authenticated users to perform unintended actions in the FDS Web interface using malicious web pages.
CWE-352 - Cross-Site Request Forgery (CSRF)| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
FDS102 >=2.0.0<=2.13.3
Frauscher / Software / FDS / 102
|
cpe:2.3:a:frauscher:fds102:*:*:*:*:*:*:*:*
|
vers:semver/>=2.0.0|<=2.13.3 |
An unauthenticated remote attacker can retrieve sensible files from the FDS Web server, such as the backup archive at /FdsBackup.zip and additional files under /downloads/*, directly over HTTP without a valid session. These files disclose detailed railway signaling and track layout information that should not be available to unauthenticated users.
A low-privileged remote attacker can enumerate all configured users and identify which accounts hold elevated privileges using the endpoint /api/user/fetch-all.php.
{
"document": {
"acknowledgments": [
{
"organization": "CERT@VDE",
"summary": "coordination",
"urls": [
"https://certvde.com"
]
}
],
"aggregate_severity": {
"namespace": "https://www.first.org/cvss/v3.1/specification-document#Qualitative-Severity-Rating-Scale",
"text": "High"
},
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "en-GB",
"notes": [
{
"category": "summary",
"text": "Frauscher Sensortechnik FDS102 for FAdC/FAdCi R2 is vulnerable to Unrestricted Upload of File with Dangerous Type, Path Traversal: \u0027../filedir\u0027, Insertion of Sensitive Information into Log File, Incorrect Authorization, Insufficient Session Expiration, Cross-Site Request Forgery (CSRF), Missing Authentication for Critical Function, and Missing Authorization.",
"title": "Summary"
},
{
"category": "description",
"text": "Successful exploitation of these vulnerabilities could allow attackers to execute arbitrary code on the FDS102 web server, write files to arbitrary server locations, hijack active administrative sessions, create privileged user accounts, perform unauthorized actions, access sensitive railway signalling and track layout information, and enumerate user accounts and privilege levels. The impact depends on the affected version and attacker privileges, but the combined issue set affects confidentiality, integrity, and availability of the FDS102 web interface and underlying system.",
"title": "Impact"
},
{
"category": "description",
"text": "Security-related application conditions SecRAC:\n\n* The railway operator must ensure that only authorised personnel or people in the company of\nauthorised personnel have access to the Frauscher Diagnostic System FDS101/FDS-SNMP101/FDS102. This applies for both vulnerabilities.\n\n* The recommendation is to connect the Frauscher Diagnostic System FDS102 to a network of category 2. If the Frauscher Diagnostic System FDS102 is connected to a network of category 3\n(according to EN 50159:2010), then additional protective measures must be added. This applies for CVE-2025-3626. ",
"title": "Mitigation"
},
{
"category": "description",
"text": "Update to FDS102 v2.14.0",
"title": "Remediation"
}
],
"publisher": {
"category": "vendor",
"contact_details": "psirt@frauscher.com",
"name": "Frauscher Sensortechnik GmbH",
"namespace": "https://www.frauscher.com"
},
"references": [
{
"category": "external",
"summary": "Frauscher advisory overview at CERT@VDE",
"url": "https://certvde.com/de/advisories/vendor/frauscher/"
},
{
"category": "external",
"summary": "Frauscher PSIRT",
"url": "https://www.frauscher.com/en/psirt"
},
{
"category": "self",
"summary": "VDE-2026-078: Frauscher: FDS102 for FAdC/FAdCi R2 has multiple vulnerabilities - HTML",
"url": "https://certvde.com/en/advisories/VDE-2026-078/"
},
{
"category": "self",
"summary": "VDE-2026-078: Frauscher: FDS102 for FAdC/FAdCi R2 has multiple vulnerabilities - CSAF",
"url": "https://frauscher.csaf-tp.certvde.com/.well-known/csaf/white/2026/vde-2026-078.json"
}
],
"title": "Frauscher: FDS102 for FAdC/FAdCi R2 has multiple vulnerabilities",
"tracking": {
"aliases": [
"VDE-2026-078"
],
"current_release_date": "2026-08-20T10:00:00.000Z",
"generator": {
"date": "2026-07-20T05:34:25.955Z",
"engine": {
"name": "Secvisogram",
"version": "2.6.4"
}
},
"id": "VDE-2026-078",
"initial_release_date": "2026-08-20T10:00:00.000Z",
"revision_history": [
{
"date": "2026-08-20T10:00:00.000Z",
"number": "1.0.0",
"summary": "Initial revision"
}
],
"status": "final",
"version": "1.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:semver/\u003e=2.0.0|\u003c=2.13.3",
"product": {
"name": "FDS102 \u003e=2.0.0\u003c=2.13.3",
"product_id": "CSAFID-51001",
"product_identification_helper": {
"cpe": "cpe:2.3:a:frauscher:fds102:*:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_version_range",
"name": "vers:semver/\u003e=2.1.0|\u003c=2.13.3",
"product": {
"name": "FDS102 \u003e=2.1.0\u003c=2.13.3",
"product_id": "CSAFID-51002",
"product_identification_helper": {
"cpe": "cpe:2.3:a:frauscher:fds102:*:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_version_range",
"name": "vers:semver/\u003e=2.8.0|\u003c=2.13.3",
"product": {
"name": "FDS102 \u003e=2.8.0\u003c=2.13.3",
"product_id": "CSAFID-51003",
"product_identification_helper": {
"cpe": "cpe:2.3:a:frauscher:fds102:*:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_version_range",
"name": "vers:semver/\u003e=2.11.0|\u003c=2.13.3",
"product": {
"name": "FDS102 \u003e=2.11.0\u003c=2.13.3",
"product_id": "CSAFID-51004",
"product_identification_helper": {
"cpe": "cpe:2.3:a:frauscher:fds102:*:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_version_range",
"name": "vers:semver/\u003e=2.13.0|\u003c=2.13.3",
"product": {
"name": "FDS102 \u003e=2.13.0\u003c=2.13.3",
"product_id": "CSAFID-51005",
"product_identification_helper": {
"cpe": "cpe:2.3:a:frauscher:fds102:*:*:*:*:*:*:*:*"
}
}
},
{
"category": "product_version",
"name": "2.14.0",
"product": {
"name": "FDS102 2.14.0",
"product_id": "CSAFID-52001",
"product_identification_helper": {
"cpe": "cpe:2.3:a:frauscher:fds102:2.14.0:*:*:*:*:*:*:*"
}
}
}
],
"category": "product_name",
"name": "102"
}
],
"category": "product_family",
"name": "FDS"
}
],
"category": "product_family",
"name": "Software"
}
],
"category": "vendor",
"name": "Frauscher"
}
],
"product_groups": [
{
"group_id": "CSAFGID-0001",
"product_ids": [
"CSAFID-51001",
"CSAFID-51002",
"CSAFID-51003",
"CSAFID-51004",
"CSAFID-51005"
],
"summary": "Affected Products."
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2026-14946",
"cwe": {
"id": "CWE-434",
"name": "Unrestricted Upload of File with Dangerous Type"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A high privileged remote attacker can upload a .php file and then request it directly from /uploads/\u003cfilename\u003e.php to achieve arbitrary code execution due to improper file type validation which could result in full system compromise.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFID-52001"
],
"known_affected": [
"CSAFID-51003"
]
},
"references": [
{
"category": "external",
"summary": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N - 8.6 / High",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to FDS102 v2.14.0",
"group_ids": [
"CSAFGID-0001"
]
},
{
"category": "mitigation",
"details": "Security-related application conditions SecRAC:\n\n* The railway operator must ensure that only authorised personnel or people in the company of\nauthorised personnel have access to the Frauscher Diagnostic System FDS102.\n\n* The recommendation is to connect the Frauscher Diagnostic System FDS102 to a network of category 2. If the Frauscher Diagnostic System FDS102 is connected to a network of category 3\n(according to EN 50159:2010), then additional protective measures must be added.",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.2,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"temporalScore": 7.2,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFID-51003"
]
}
],
"title": "Frauscher Sensortechnik: FDS102 for FAdC/FAdCi R2 is vulnerable to Remote Code Execution via malicious configuration file."
},
{
"cve": "CVE-2026-14947",
"cwe": {
"id": "CWE-24",
"name": "Path Traversal: \u0027../filedir\u0027"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A high-privileged remote attacker can upload malicious ZIP archive containing directory traversal sequences such as ../ can escape the intended extraction directory and write files to arbitrary locations on the server, potentially achieve arbitrary code execution due to improper validation of archive entry paths before writing files to disk which could result in full system compromise.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFID-52001"
],
"known_affected": [
"CSAFID-51003"
]
},
"references": [
{
"category": "external",
"summary": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N - 8.6 / High",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to FDS102 v2.14.0",
"group_ids": [
"CSAFGID-0001"
]
},
{
"category": "mitigation",
"details": "Security-related application conditions SecRAC:\n\n* The railway operator must ensure that only authorised personnel or people in the company of\nauthorised personnel have access to the Frauscher Diagnostic System FDS102.\n\n* The recommendation is to connect the Frauscher Diagnostic System FDS102 to a network of category 2. If the Frauscher Diagnostic System FDS102 is connected to a network of category 3\n(according to EN 50159:2010), then additional protective measures must be added.",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.2,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"temporalScore": 7.2,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFID-51003"
]
}
],
"title": "Frauscher Sensortechnik: FDS102 for FAdC/FAdCi R2 is vulnerable to Remote Code Execution via malicious ZIP file"
},
{
"cve": "CVE-2026-14948",
"cwe": {
"id": "CWE-532",
"name": "Insertion of Sensitive Information into Log File"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A low privileged remote attacker can hijack an active administrative session without needing to know the administrator password by extracting live plaintext session identifiers for authenticated users from downloadable error log archives.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFID-52001"
],
"known_affected": [
"CSAFID-51005"
]
},
"references": [
{
"category": "external",
"summary": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N - 8.7 / High",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to FDS102 v2.14.0",
"group_ids": [
"CSAFGID-0001"
]
},
{
"category": "mitigation",
"details": "Security-related application conditions SecRAC:\n\n* The railway operator must ensure that only authorised personnel or people in the company of\nauthorised personnel have access to the Frauscher Diagnostic System FDS102.\n\n* The recommendation is to connect the Frauscher Diagnostic System FDS102 to a network of category 2. If the Frauscher Diagnostic System FDS102 is connected to a network of category 3\n(according to EN 50159:2010), then additional protective measures must be added.",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFID-51005"
]
}
],
"title": "Frauscher Sensortechnik: FDS102 for FAdC/FAdCi R2 is vulnerable to Insertion of Sensitive Information into Log File via error log archives"
},
{
"cve": "CVE-2026-14949",
"cwe": {
"id": "CWE-863",
"name": "Incorrect Authorization"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A low privileged remote attacker with a valid session can submit a request to the user creation functionality exposed through /api/user/add.php to create new accounts with arbitrary role values, including the highest privilege level used by the application.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFID-52001"
],
"known_affected": [
"CSAFID-51004"
]
},
"references": [
{
"category": "external",
"summary": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:H/SI:H/SA:H - 8.5 / High",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:H/SI:H/SA:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to FDS102 v2.14.0",
"group_ids": [
"CSAFGID-0001"
]
},
{
"category": "mitigation",
"details": "Security-related application conditions SecRAC:\n\n* The railway operator must ensure that only authorised personnel or people in the company of\nauthorised personnel have access to the Frauscher Diagnostic System FDS102.\n\n* The recommendation is to connect the Frauscher Diagnostic System FDS102 to a network of category 2. If the Frauscher Diagnostic System FDS102 is connected to a network of category 3\n(according to EN 50159:2010), then additional protective measures must be added.",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 6.5,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 6.5,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"CSAFID-51004"
]
}
],
"title": "Frauscher Sensortechnik: FDS102 for FAdC/FAdCi R2 is vulnerable to Incorrect Authorization due to improper enforcement of role-based access control"
},
{
"cve": "CVE-2026-14950",
"cwe": {
"id": "CWE-613",
"name": "Insufficient Session Expiration"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated remote attacker in possession of a valid session identifier is able to continue using the session after it should have expired. This increases the risk associated with stolen, leaked, shared, or unattended sessions and may enable unauthorized continued access to the FDS web interface.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFID-52001"
],
"known_affected": [
"CSAFID-51002"
]
},
"references": [
{
"category": "external",
"summary": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N - 9.3 / Critical",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to FDS102 v2.14.0",
"group_ids": [
"CSAFGID-0001"
]
},
{
"category": "mitigation",
"details": "Security-related application conditions SecRAC:\n\n* The railway operator must ensure that only authorised personnel or people in the company of\nauthorised personnel have access to the Frauscher Diagnostic System FDS102.\n\n* The recommendation is to connect the Frauscher Diagnostic System FDS102 to a network of category 2. If the Frauscher Diagnostic System FDS102 is connected to a network of category 3\n(according to EN 50159:2010), then additional protective measures must be added.",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"environmentalScore": 9.8,
"environmentalSeverity": "CRITICAL",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 9.8,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFID-51002"
]
}
],
"title": "Frauscher Sensortechnik: FDS102 for FAdC/FAdCi R2 is vulnerable to Insufficient Session Expiration due to flawed session expiration logic"
},
{
"cve": "CVE-2026-14951",
"cwe": {
"id": "CWE-352",
"name": "Cross-Site Request Forgery (CSRF)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An low privileged remote attacker can cause authenticated users to perform unintended actions in the FDS Web interface using malicious web pages.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFID-52001"
],
"known_affected": [
"CSAFID-51001"
]
},
"references": [
{
"category": "external",
"summary": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N - 8.6 / High",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to FDS102 v2.14.0",
"group_ids": [
"CSAFGID-0001"
]
},
{
"category": "mitigation",
"details": "Security-related application conditions SecRAC:\n\n* The railway operator must ensure that only authorised personnel or people in the company of\nauthorised personnel have access to the Frauscher Diagnostic System FDS102.\n\n* The recommendation is to connect the Frauscher Diagnostic System FDS102 to a network of category 2. If the Frauscher Diagnostic System FDS102 is connected to a network of category 3\n(according to EN 50159:2010), then additional protective measures must be added.",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 8,
"temporalSeverity": "HIGH",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFID-51001"
]
}
],
"title": "Frauscher Sensortechnik: FDS102 for FAdC/FAdCi R2 is vulnerable to Cross-Site Request Forgery due to missing CSFR protection headers"
},
{
"cve": "CVE-2026-14952",
"cwe": {
"id": "CWE-306",
"name": "Missing Authentication for Critical Function"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "An unauthenticated remote attacker can retrieve sensible files from the FDS Web server, such as the backup archive at /FdsBackup.zip and additional files under /downloads/*, directly over HTTP without a valid session. These files disclose detailed railway signaling and track layout information that should not be available to unauthenticated users.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFID-52001"
],
"known_affected": [
"CSAFID-51002"
]
},
"references": [
{
"category": "external",
"summary": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N - 8.7 / High",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to FDS102 v2.14.0",
"group_ids": [
"CSAFGID-0001"
]
},
{
"category": "mitigation",
"details": "Security-related application conditions SecRAC:\n\n* The railway operator must ensure that only authorised personnel or people in the company of\nauthorised personnel have access to the Frauscher Diagnostic System FDS102.\n\n* The recommendation is to connect the Frauscher Diagnostic System FDS102 to a network of category 2. If the Frauscher Diagnostic System FDS102 is connected to a network of category 3\n(according to EN 50159:2010), then additional protective measures must be added.",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.5,
"environmentalSeverity": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 7.5,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFID-51002"
]
}
],
"title": "Frauscher Sensortechnik: FDS102 for FAdC/FAdCi R2 is offering files with sensitive information for download without requiring authentication"
},
{
"cve": "CVE-2026-14953",
"cwe": {
"id": "CWE-425",
"name": "Direct Request (\u0027Forced Browsing\u0027)"
},
"notes": [
{
"audience": "all",
"category": "description",
"text": "A low-privileged remote attacker can enumerate all configured users and identify which accounts hold elevated privileges using the endpoint /api/user/fetch-all.php.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"CSAFID-52001"
],
"known_affected": [
"CSAFID-51004"
]
},
"references": [
{
"category": "external",
"summary": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N - 5.3 / Medium",
"url": "https://www.first.org/cvss/calculator/4.0#CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update to FDS102 v2.14.0",
"group_ids": [
"CSAFGID-0001"
]
},
{
"category": "mitigation",
"details": "Security-related application conditions SecRAC:\n\n* The railway operator must ensure that only authorised personnel or people in the company of\nauthorised personnel have access to the Frauscher Diagnostic System FDS102.\n\n* The recommendation is to connect the Frauscher Diagnostic System FDS102 to a network of category 2. If the Frauscher Diagnostic System FDS102 is connected to a network of category 3\n(according to EN 50159:2010), then additional protective measures must be added.",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"environmentalScore": 4.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 4.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"CSAFID-51004"
]
}
],
"title": "Frauscher Sensortechnik: FDS102 for FAdC/FAdCi R2 is Missing Authorization due to improper enforcement of role-based access control"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.