VAR-202510-0712

Vulnerability from variot - Updated: 2025-11-19 23:22

A Stored Cross-Site Scripting security issue exists in the affected product that could potentially allow a malicious user to view and modify sensitive data or make the webpage unavailable. The vulnerability stems from missing special character filtering and encoding. Successful exploitation requires an attacker to be able to update configuration fields behind admin login. The Rockwell Automation Comms-1783-NATR is an industrial Ethernet address translation device from Rockwell Automation.

The Rockwell Automation Comms-1783-NATR suffers from a cross-site scripting vulnerability caused by improper validation of user-supplied input

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202510-0712",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "1783-natr",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "1.007"
      },
      {
        "model": "automation comms 1783-natr",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwell",
        "version": "-\u003c=1.006"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-24585"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-7329"
      }
    ]
  },
  "cve": "CVE-2025-7329",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 6.4,
            "id": "CNVD-2025-24585",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 4.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 1.7,
            "id": "CVE-2025-7329",
            "impactScore": 2.7,
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2025-7329",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "PSIRT@rockwellautomation.com",
            "id": "CVE-2025-7329",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-24585",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-24585"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-7329"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-7329"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A Stored Cross-Site Scripting security issue exists in the affected product that could potentially allow a malicious user to view and modify sensitive data or make the webpage unavailable. The vulnerability stems from missing special character filtering and encoding. Successful exploitation requires an attacker to be able to update configuration fields behind admin login. The Rockwell Automation Comms-1783-NATR is an industrial Ethernet address translation device from Rockwell Automation. \n\nThe Rockwell Automation Comms-1783-NATR suffers from a cross-site scripting vulnerability caused by improper validation of user-supplied input",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-7329"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-24585"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-7329",
        "trust": 1.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-24585",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-24585"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-7329"
      }
    ]
  },
  "id": "VAR-202510-0712",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-24585"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-24585"
      }
    ]
  },
  "last_update_date": "2025-11-19T23:22:56.769000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Rockwell Automation Comms-1783-NATR Cross-Site Scripting Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/745551"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-24585"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-79",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-7329"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.sd1756.html"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-24585"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-7329"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-24585"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-7329"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-10-23T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-24585"
      },
      {
        "date": "2025-10-14T13:15:39.157000",
        "db": "NVD",
        "id": "CVE-2025-7329"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-10-23T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-24585"
      },
      {
        "date": "2025-10-30T21:43:57.893000",
        "db": "NVD",
        "id": "CVE-2025-7329"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Rockwell Automation Comms-1783-NATR Cross-Site Scripting Vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-24585"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…