VAR-202509-3819
Vulnerability from variot - Updated: 2025-10-10 23:37A security vulnerability has been detected in Tenda AC18 15.03.05.19. The impacted element is an unknown function of the file /goform/AdvSetLanip. The manipulation of the argument lanIp leads to command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC18 The firmware contains injection and command injection vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. in July 2016, primarily for villas and large homes.
The Tenda AC18 suffers from a command injection vulnerability caused by improper handling of the lanIp parameter by an unknown function in the /goform/AdvSetLanip file. Detailed vulnerability details are currently unavailable
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202509-3819",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac18",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "15.03.05.19"
},
{
"model": "ac18",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac18",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac18",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac18 firmware 15.03.05.19"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-23114"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-015232"
},
{
"db": "NVD",
"id": "CVE-2025-11121"
}
]
},
"cve": "CVE-2025-11121",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CVE-2025-11121",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Partial",
"baseScore": 6.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2025-015232",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CNVD-2025-23114",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.8,
"id": "CVE-2025-11121",
"impactScore": 3.4,
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2025-11121",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-015232",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-11121",
"trust": 1.0,
"value": "Low"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2025-11121",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2025-015232",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-23114",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-23114"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-015232"
},
{
"db": "NVD",
"id": "CVE-2025-11121"
},
{
"db": "NVD",
"id": "CVE-2025-11121"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A security vulnerability has been detected in Tenda AC18 15.03.05.19. The impacted element is an unknown function of the file /goform/AdvSetLanip. The manipulation of the argument lanIp leads to command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used. Shenzhen Tenda Technology Co.,Ltd. of AC18 The firmware contains injection and command injection vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. in July 2016, primarily for villas and large homes. \n\nThe Tenda AC18 suffers from a command injection vulnerability caused by improper handling of the lanIp parameter by an unknown function in the /goform/AdvSetLanip file. Detailed vulnerability details are currently unavailable",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-11121"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-015232"
},
{
"db": "CNVD",
"id": "CNVD-2025-23114"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-11121",
"trust": 3.2
},
{
"db": "VULDB",
"id": "326202",
"trust": 2.4
},
{
"db": "JVNDB",
"id": "JVNDB-2025-015232",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-23114",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-23114"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-015232"
},
{
"db": "NVD",
"id": "CVE-2025-11121"
}
]
},
"id": "VAR-202509-3819",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-23114"
}
],
"trust": 1.00125
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-23114"
}
]
},
"last_update_date": "2025-10-10T23:37:27.499000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-74",
"trust": 1.0
},
{
"problemtype": "CWE-77",
"trust": 1.0
},
{
"problemtype": "injection (CWE-74) [ others ]",
"trust": 0.8
},
{
"problemtype": " Command injection (CWE-77) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-015232"
},
{
"db": "NVD",
"id": "CVE-2025-11121"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://vuldb.com/?id.326202"
},
{
"trust": 2.4,
"url": "https://vuldb.com/?submit.664191"
},
{
"trust": 2.4,
"url": "https://github.com/noahze01/iot-vulnerable/blob/main/tenda/ac18/advsetlanip.md"
},
{
"trust": 2.4,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.6,
"url": "https://vuldb.com/?ctiid.326202"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-11121"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-23114"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-015232"
},
{
"db": "NVD",
"id": "CVE-2025-11121"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-23114"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-015232"
},
{
"db": "NVD",
"id": "CVE-2025-11121"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-10-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-23114"
},
{
"date": "2025-10-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-015232"
},
{
"date": "2025-09-28T22:15:31.377000",
"db": "NVD",
"id": "CVE-2025-11121"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-10-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-23114"
},
{
"date": "2025-10-07T04:53:00",
"db": "JVNDB",
"id": "JVNDB-2025-015232"
},
{
"date": "2025-10-03T13:45:50.333000",
"db": "NVD",
"id": "CVE-2025-11121"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC18\u00a0 Injection Vulnerability in Firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-015232"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.