VAR-202509-0004
Vulnerability from variot - Updated: 2025-11-25 00:05A security vulnerability has been detected in Tenda W12 up to 3.0.0.6(3948). Affected is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. The manipulation leads to hard-coded credentials. An attack has to be approached locally. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed publicly and may be used. Shenzhen Tenda Technology Co.,Ltd. of W12 A vulnerability exists in the firmware regarding the use of hardcoded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W12 is a dual-band gigabit wireless panel access point (AP) from Tenda Technology, designed for scenarios such as hotels, villas, and large apartments. It supports the IEEE 802.11ac protocol and the Wave2 standard, and boasts a dual-band concurrent speed of 1167Mbps. Attackers can exploit this vulnerability to obtain sensitive information
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202509-0004",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w12",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "3.0.0.6\\(3948\\)"
},
{
"model": "w12",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w12",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w12 firmware 3.0.0.6(3948)"
},
{
"model": "w12",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w12",
"scope": "lte",
"trust": 0.6,
"vendor": "jixiang tengda",
"version": "\u003c=123.0.0.63948"
},
{
"model": "w12",
"scope": "lte",
"trust": 0.6,
"vendor": "tenda",
"version": "\u003c=3.0.0.6(3948)"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-28848"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013160"
},
{
"db": "NVD",
"id": "CVE-2025-9778"
}
]
},
"cve": "CVE-2025-9778",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "HIGH",
"accessVector": "LOCAL",
"authentication": "MULTIPLE",
"author": "cna@vuldb.com",
"availabilityImpact": "NONE",
"baseScore": 0.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 1.2,
"id": "CVE-2025-9778",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 1.0,
"vectorString": "AV:L/AC:H/Au:M/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "High",
"accessVector": "Local",
"authentication": "Multiple",
"author": "OTHER",
"availabilityImpact": "None",
"baseScore": 0.8,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2025-013160",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Low",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:L/AC:H/Au:M/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "HIGH",
"accessVector": "LOCAL",
"authentication": "MULTIPLE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 0.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 1.2,
"id": "CNVD-2025-28848",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "LOW",
"trust": 0.6,
"vectorString": "AV:L/AC:H/Au:M/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"author": "cna@vuldb.com",
"availabilityImpact": "NONE",
"baseScore": 1.9,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"exploitabilityScore": 0.5,
"id": "CVE-2025-9778",
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.0,
"id": "CVE-2025-9778",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "High",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.0,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-013160",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-9778",
"trust": 1.0,
"value": "Low"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2025-9778",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2025-013160",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-28848",
"trust": 0.6,
"value": "LOW"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-28848"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013160"
},
{
"db": "NVD",
"id": "CVE-2025-9778"
},
{
"db": "NVD",
"id": "CVE-2025-9778"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A security vulnerability has been detected in Tenda W12 up to 3.0.0.6(3948). Affected is an unknown function of the file /etc_ro/shadow of the component Administrative Interface. The manipulation leads to hard-coded credentials. An attack has to be approached locally. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed publicly and may be used. Shenzhen Tenda Technology Co.,Ltd. of W12 A vulnerability exists in the firmware regarding the use of hardcoded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda W12 is a dual-band gigabit wireless panel access point (AP) from Tenda Technology, designed for scenarios such as hotels, villas, and large apartments. It supports the IEEE 802.11ac protocol and the Wave2 standard, and boasts a dual-band concurrent speed of 1167Mbps. Attackers can exploit this vulnerability to obtain sensitive information",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-9778"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013160"
},
{
"db": "CNVD",
"id": "CNVD-2025-28848"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-9778",
"trust": 3.2
},
{
"db": "VULDB",
"id": "322080",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013160",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-28848",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-28848"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013160"
},
{
"db": "NVD",
"id": "CVE-2025-9778"
}
]
},
"id": "VAR-202509-0004",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-28848"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-28848"
}
]
},
"last_update_date": "2025-11-25T00:05:03.112000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-259",
"trust": 1.0
},
{
"problemtype": "CWE-798",
"trust": 1.0
},
{
"problemtype": "Using hardcoded passwords (CWE-259) [ others ]",
"trust": 0.8
},
{
"problemtype": " Use hard-coded credentials (CWE-798) [NVD evaluation ]",
"trust": 0.8
},
{
"problemtype": " Use hard-coded credentials (CWE-798) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-013160"
},
{
"db": "NVD",
"id": "CVE-2025-9778"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://vuldb.com/?id.322080"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.640969"
},
{
"trust": 1.8,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-9778"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.322080"
},
{
"trust": 1.0,
"url": "https://github.com/august829/yu/blob/main/58ead8e7e08bfb0e8.md"
},
{
"trust": 1.0,
"url": "https://github.com/august829/yu/blob/main/58ead8e7e08bfb0e8.md#steps-to-reproduce"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-28848"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013160"
},
{
"db": "NVD",
"id": "CVE-2025-9778"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-28848"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013160"
},
{
"db": "NVD",
"id": "CVE-2025-9778"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-11-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-28848"
},
{
"date": "2025-09-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-013160"
},
{
"date": "2025-09-01T12:15:32.180000",
"db": "NVD",
"id": "CVE-2025-9778"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-11-20T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-28848"
},
{
"date": "2025-09-05T09:32:00",
"db": "JVNDB",
"id": "JVNDB-2025-013160"
},
{
"date": "2025-09-04T16:19:21.700000",
"db": "NVD",
"id": "CVE-2025-9778"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0W12\u00a0 Vulnerability related to use of hardcoded credentials in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-013160"
}
],
"trust": 0.8
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.