VAR-202508-2559
Vulnerability from variot - Updated: 2025-09-13 23:15Incorrect access control in the config.xgi function of D-Link DSL-7740C with firmware DSL7740C.V6.TR069.20211230 allows attackers to download the configuration file via providing a crafted web request. D-Link Corporation of DSL-7740C Firmware contains an access control vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The D-Link DSL-7740C is a modem manufactured by D-Link, a Chinese company.
The D-Link DSL-7740C suffers from an access control vulnerability caused by improper access control in the config.xgi function. An attacker could exploit this vulnerability to download the configuration file
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202508-2559",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "dsl-7740c",
"scope": "eq",
"trust": 1.0,
"vendor": "dlink",
"version": "6.tr069.20211230"
},
{
"model": "dsl-7740c",
"scope": "eq",
"trust": 0.8,
"vendor": "d link",
"version": null
},
{
"model": "dsl-7740c",
"scope": "eq",
"trust": 0.8,
"vendor": "d link",
"version": "dsl-7740c firmware 6.tr069.20211230"
},
{
"model": "dsl-7740c",
"scope": null,
"trust": 0.8,
"vendor": "d link",
"version": null
},
{
"model": "dsl-7740c dsl7740c.v6.tr069.20211230",
"scope": null,
"trust": 0.6,
"vendor": "d link",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21168"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-012816"
},
{
"db": "NVD",
"id": "CVE-2025-29514"
}
]
},
"cve": "CVE-2025-29514",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-21168",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2025-29514",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-012816",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-29514",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "OTHER",
"id": "JVNDB-2025-012816",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-21168",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21168"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-012816"
},
{
"db": "NVD",
"id": "CVE-2025-29514"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Incorrect access control in the config.xgi function of D-Link DSL-7740C with firmware DSL7740C.V6.TR069.20211230 allows attackers to download the configuration file via providing a crafted web request. D-Link Corporation of DSL-7740C Firmware contains an access control vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The D-Link DSL-7740C is a modem manufactured by D-Link, a Chinese company. \n\nThe D-Link DSL-7740C suffers from an access control vulnerability caused by improper access control in the config.xgi function. An attacker could exploit this vulnerability to download the configuration file",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-29514"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-012816"
},
{
"db": "CNVD",
"id": "CNVD-2025-21168"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-29514",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2025-012816",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-21168",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21168"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-012816"
},
{
"db": "NVD",
"id": "CVE-2025-29514"
}
]
},
"id": "VAR-202508-2559",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21168"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21168"
}
]
},
"last_update_date": "2025-09-13T23:15:46.108000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-284",
"trust": 1.0
},
{
"problemtype": "Inappropriate access control (CWE-284) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-012816"
},
{
"db": "NVD",
"id": "CVE-2025-29514"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://gist.github.com/stevenyu113228/1fc5dcc63e4b4e9f5523167be11abf17"
},
{
"trust": 1.8,
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-29514"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-21168"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-012816"
},
{
"db": "NVD",
"id": "CVE-2025-29514"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-21168"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-012816"
},
{
"db": "NVD",
"id": "CVE-2025-29514"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-29T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-21168"
},
{
"date": "2025-09-03T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-012816"
},
{
"date": "2025-08-25T14:15:30.310000",
"db": "NVD",
"id": "CVE-2025-29514"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-21168"
},
{
"date": "2025-09-03T07:23:00",
"db": "JVNDB",
"id": "JVNDB-2025-012816"
},
{
"date": "2025-09-02T18:17:12.577000",
"db": "NVD",
"id": "CVE-2025-29514"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "D-Link\u00a0Corporation\u00a0 of \u00a0DSL-7740C\u00a0 Access control vulnerabilities in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-012816"
}
],
"trust": 0.8
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Loading…
Loading…