VAR-202507-0487
Vulnerability from variot - Updated: 2025-07-23 23:17A vulnerability classified as critical was found in Tenda FH1201 1.2.0.14. Affected by this vulnerability is the function fromRouteStatic of the file /goform/fromRouteStatic of the component HTTP POST Request Handler. The manipulation of the argument page leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of fh1201 The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.
Tenda FH1201 has a buffer overflow vulnerability, which is caused by the parameter page in the file /goform/fromRouteStatic failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202507-0487",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "fh1201",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "1.2.0.14"
},
{
"model": "fh1201",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "fh1201",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "fh1201 firmware 1.2.0.14"
},
{
"model": "fh1201",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16634"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-008969"
},
{
"db": "NVD",
"id": "CVE-2025-7465"
}
]
},
"cve": "CVE-2025-7465",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2025-7465",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2025-008969",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2025-16634",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2025-7465",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-008969",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-7465",
"trust": 1.0,
"value": "High"
},
{
"author": "OTHER",
"id": "JVNDB-2025-008969",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-16634",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16634"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-008969"
},
{
"db": "NVD",
"id": "CVE-2025-7465"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability classified as critical was found in Tenda FH1201 1.2.0.14. Affected by this vulnerability is the function fromRouteStatic of the file /goform/fromRouteStatic of the component HTTP POST Request Handler. The manipulation of the argument page leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Shenzhen Tenda Technology Co.,Ltd. of fh1201 The firmware contains a buffer error vulnerability and a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda FH1201 has a buffer overflow vulnerability, which is caused by the parameter page in the file /goform/fromRouteStatic failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-7465"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-008969"
},
{
"db": "CNVD",
"id": "CNVD-2025-16634"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-7465",
"trust": 3.2
},
{
"db": "VULDB",
"id": "316117",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-008969",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-16634",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16634"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-008969"
},
{
"db": "NVD",
"id": "CVE-2025-7465"
}
]
},
"id": "VAR-202507-0487",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16634"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16634"
}
]
},
"last_update_date": "2025-07-23T23:17:32.035000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.0
},
{
"problemtype": "CWE-120",
"trust": 1.0
},
{
"problemtype": "Buffer error (CWE-119) [ others ]",
"trust": 0.8
},
{
"problemtype": " Classic buffer overflow (CWE-120) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-008969"
},
{
"db": "NVD",
"id": "CVE-2025-7465"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://candle-throne-f75.notion.site/tenda-fh1201-fromroutestatic-229df0aa118580ba952bd3f16857b176"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.316117"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.610389"
},
{
"trust": 1.8,
"url": "https://www.tenda.com.cn/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-7465"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.316117"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-16634"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-008969"
},
{
"db": "NVD",
"id": "CVE-2025-7465"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-16634"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-008969"
},
{
"db": "NVD",
"id": "CVE-2025-7465"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-07-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-16634"
},
{
"date": "2025-07-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-008969"
},
{
"date": "2025-07-12T07:15:23.240000",
"db": "NVD",
"id": "CVE-2025-7465"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-07-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-16634"
},
{
"date": "2025-07-16T04:59:00",
"db": "JVNDB",
"id": "JVNDB-2025-008969"
},
{
"date": "2025-07-15T18:09:06.997000",
"db": "NVD",
"id": "CVE-2025-7465"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0fh1201\u00a0 Buffer error vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-008969"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.