VAR-202507-0126
Vulnerability from variot - Updated: 2025-07-17 23:50Tenda AC6 v15.03.05.16_multi is vulnerable to Buffer Overflow in the fromSetRouteStatic function via the list parameter. Shenzhen Tenda Technology Co.,Ltd. of AC6 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the list parameter in the fromSetRouteStatic function failing to correctly verify the length of the input data. No detailed vulnerability details are currently provided
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202507-0126",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.05.16_multi"
},
{
"model": "ac6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac6 firmware 15.03.05.16 multi"
},
{
"model": "ac6",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6 15.03.05.16 multi",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-15719"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-008139"
},
{
"db": "NVD",
"id": "CVE-2025-50263"
}
]
},
"cve": "CVE-2025-50263",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.6,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 4.9,
"id": "CNVD-2025-15719",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:H/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.2,
"id": "CVE-2025-50263",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "High",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.1,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-008139",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-50263",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2025-008139",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-15719",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-15719"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-008139"
},
{
"db": "NVD",
"id": "CVE-2025-50263"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC6 v15.03.05.16_multi is vulnerable to Buffer Overflow in the fromSetRouteStatic function via the list parameter. Shenzhen Tenda Technology Co.,Ltd. of AC6 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the list parameter in the fromSetRouteStatic function failing to correctly verify the length of the input data. No detailed vulnerability details are currently provided",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-50263"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-008139"
},
{
"db": "CNVD",
"id": "CNVD-2025-15719"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-50263",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2025-008139",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-15719",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-15719"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-008139"
},
{
"db": "NVD",
"id": "CVE-2025-50263"
}
]
},
"id": "VAR-202507-0126",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-15719"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-15719"
}
]
},
"last_update_date": "2025-07-17T23:50:11.062000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda AC6 fromSetRouteStatic function buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/709066"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-15719"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.0
},
{
"problemtype": "Classic buffer overflow (CWE-120) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-008139"
},
{
"db": "NVD",
"id": "CVE-2025-50263"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/faqiadegege/iotvuln/blob/main/tendaac6_setstaticroutecfg_list_overflow/detail.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-50263"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-15719"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-008139"
},
{
"db": "NVD",
"id": "CVE-2025-50263"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-15719"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-008139"
},
{
"db": "NVD",
"id": "CVE-2025-50263"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-07-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-15719"
},
{
"date": "2025-07-08T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-008139"
},
{
"date": "2025-07-03T14:15:32.923000",
"db": "NVD",
"id": "CVE-2025-50263"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-07-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-15719"
},
{
"date": "2025-07-08T02:14:00",
"db": "JVNDB",
"id": "JVNDB-2025-008139"
},
{
"date": "2025-07-07T14:40:36.470000",
"db": "NVD",
"id": "CVE-2025-50263"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC6\u00a0 Classic buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-008139"
}
],
"trust": 0.8
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…