VAR-202506-0908

Vulnerability from variot - Updated: 2025-06-27 23:03

Buffer Overflow vulnerability in TOTOLINK N600R v4.3.0cu.7866_B2022506 allows a remote attacker to execute arbitrary code via the UPLOAD_FILENAME component. TOTOLINK of n600r Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK N600R is a wireless router from China's TOTOLINK Electronics.

TOTOLINK N600R V4.3.0cu.7866_B2022506 has a buffer overflow vulnerability. The vulnerability is caused by the UPLOAD_FILENAME component failing to properly verify the length of the input data

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202506-0908",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "n600r",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "totolink",
        "version": "4.3.0cu.7866_b2022506"
      },
      {
        "model": "n600r",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "totolink",
        "version": "n600r  firmware  4.3.0cu.7866 b2022506"
      },
      {
        "model": "n600r",
        "scope": null,
        "trust": 0.8,
        "vendor": "totolink",
        "version": null
      },
      {
        "model": "n600r",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "totolink",
        "version": null
      },
      {
        "model": "n600r v4.3.0cu.7866 b2022506",
        "scope": null,
        "trust": 0.6,
        "vendor": "totolink",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-13789"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007112"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-46060"
      }
    ]
  },
  "cve": "CVE-2025-46060",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2025-13789",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2025-46060",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2025-007112",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2025-46060",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2025-007112",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-13789",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-13789"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007112"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-46060"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer Overflow vulnerability in TOTOLINK N600R v4.3.0cu.7866_B2022506 allows a remote attacker to execute arbitrary code via the UPLOAD_FILENAME component. TOTOLINK of n600r Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK N600R is a wireless router from China\u0027s TOTOLINK Electronics. \n\nTOTOLINK N600R V4.3.0cu.7866_B2022506 has a buffer overflow vulnerability. The vulnerability is caused by the UPLOAD_FILENAME component failing to properly verify the length of the input data",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2025-46060"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007112"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-13789"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2025-46060",
        "trust": 3.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007112",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-13789",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-13789"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007112"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-46060"
      }
    ]
  },
  "id": "VAR-202506-0908",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-13789"
      }
    ],
    "trust": 1.1518367
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-13789"
      }
    ]
  },
  "last_update_date": "2025-06-27T23:03:27.505000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      },
      {
        "problemtype": "Classic buffer overflow (CWE-120) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007112"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-46060"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "http://totolink.com"
      },
      {
        "trust": 1.8,
        "url": "https://github.com/luanruy/qax"
      },
      {
        "trust": 1.8,
        "url": "https://github.com/luanruy/qax/blob/main/cve-2025-46060_info.md"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2025-46060"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-13789"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007112"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-46060"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-13789"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007112"
      },
      {
        "db": "NVD",
        "id": "CVE-2025-46060"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-06-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-13789"
      },
      {
        "date": "2025-06-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-007112"
      },
      {
        "date": "2025-06-13T13:15:21.187000",
        "db": "NVD",
        "id": "CVE-2025-46060"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-06-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-13789"
      },
      {
        "date": "2025-06-17T02:59:00",
        "db": "JVNDB",
        "id": "JVNDB-2025-007112"
      },
      {
        "date": "2025-06-16T14:58:41.900000",
        "db": "NVD",
        "id": "CVE-2025-46060"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "TOTOLINK\u00a0 of \u00a0n600r\u00a0 Classic buffer overflow vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2025-007112"
      }
    ],
    "trust": 0.8
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…