Vulnerability from variot - Updated: 2025-09-14 23:40Autel MaxiCharger AC Wallbox Commercial wLength Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the handling of USB frame packets. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-26328. maxicharger ac elite business c50 firmware, MaxiCharger AC Pro firmware, MaxiCharger AC Ultra firmware etc. autel The product contains a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Autel MaxiCharger AC Wallbox Commercial is a smart AI electric vehicle charger from Autel, a US company. The vulnerability is caused by the USB frame packet failing to correctly verify the length of the input data
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202506-0617",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "maxicharger ac ultra",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger dc compact pedestal",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger dc fast",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger dc compact mobile",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger dh480",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger dc hipower",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger single charger",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger ac pro",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger ac elite business c50",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger dc compact pedestal",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger single charger",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger ac ultra",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger dc fast",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger dc hipower",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger dh480",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger ac pro",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger dc compact mobile",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger ac elite business c50",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger single charger",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger ac pro",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger dc compact mobile",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger dc compact pedestal",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger dc fast",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger ac elite business c50",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger ac ultra",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger dc hipower",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger dh480",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger ac wallbox commercial",
"scope": null,
"trust": 0.7,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger ac wallbox commercial \u003cv1.39.51",
"scope": null,
"trust": 0.6,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger ac wallbox commercial \u003cv1.56.51",
"scope": null,
"trust": 0.6,
"vendor": "autel",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-347"
},
{
"db": "CNVD",
"id": "CNVD-2025-14948"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013732"
},
{
"db": "NVD",
"id": "CVE-2025-5828"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Synacktiv",
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-347"
}
],
"trust": 0.7
},
"cve": "CVE-2025-5828",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2025-14948",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"author": "zdi-disclosures@trendmicro.com",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.9,
"id": "CVE-2025-5828",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Physical",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 6.8,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-013732",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.9,
"id": "CVE-2025-5828",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "NONE",
"vectorString": "AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "zdi-disclosures@trendmicro.com",
"id": "CVE-2025-5828",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "OTHER",
"id": "JVNDB-2025-013732",
"trust": 0.8,
"value": "Medium"
},
{
"author": "ZDI",
"id": "CVE-2025-5828",
"trust": 0.7,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2025-14948",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-347"
},
{
"db": "CNVD",
"id": "CNVD-2025-14948"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013732"
},
{
"db": "NVD",
"id": "CVE-2025-5828"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Autel MaxiCharger AC Wallbox Commercial wLength Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial EV chargers. Authentication is not required to exploit this vulnerability. \n\nThe specific flaw exists within the handling of USB frame packets. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-26328. maxicharger ac elite business c50 firmware, MaxiCharger AC Pro firmware, MaxiCharger AC Ultra firmware etc. autel The product contains a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Autel MaxiCharger AC Wallbox Commercial is a smart AI electric vehicle charger from Autel, a US company. The vulnerability is caused by the USB frame packet failing to correctly verify the length of the input data",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-5828"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013732"
},
{
"db": "ZDI",
"id": "ZDI-25-347"
},
{
"db": "CNVD",
"id": "CNVD-2025-14948"
}
],
"trust": 2.79
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-5828",
"trust": 3.9
},
{
"db": "ZDI",
"id": "ZDI-25-347",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013732",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-26328",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2025-14948",
"trust": 0.6
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-347"
},
{
"db": "CNVD",
"id": "CNVD-2025-14948"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013732"
},
{
"db": "NVD",
"id": "CVE-2025-5828"
}
]
},
"id": "VAR-202506-0617",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-14948"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"IoT"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-14948"
}
]
},
"last_update_date": "2025-09-14T23:40:14.436000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Autel MaxiCharger AC Wallbox Commercial Buffer Overflow Vulnerability (CNVD-2025-14948)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/704536"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-14948"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.0
},
{
"problemtype": "Classic buffer overflow (CWE-120) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-013732"
},
{
"db": "NVD",
"id": "CVE-2025-5828"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://www.zerodayinitiative.com/advisories/zdi-25-347/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-5828"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-14948"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013732"
},
{
"db": "NVD",
"id": "CVE-2025-5828"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-25-347"
},
{
"db": "CNVD",
"id": "CNVD-2025-14948"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013732"
},
{
"db": "NVD",
"id": "CVE-2025-5828"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-06-11T00:00:00",
"db": "ZDI",
"id": "ZDI-25-347"
},
{
"date": "2025-07-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-14948"
},
{
"date": "2025-09-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-013732"
},
{
"date": "2025-06-25T18:15:23.683000",
"db": "NVD",
"id": "CVE-2025-5828"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-06-11T00:00:00",
"db": "ZDI",
"id": "ZDI-25-347"
},
{
"date": "2025-07-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-14948"
},
{
"date": "2025-09-11T23:17:00",
"db": "JVNDB",
"id": "JVNDB-2025-013732"
},
{
"date": "2025-09-10T14:46:41.230000",
"db": "NVD",
"id": "CVE-2025-5828"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0autel\u00a0 Classic buffer overflow vulnerability in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-013732"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.