VAR-202505-1103
Vulnerability from variot - Updated: 2025-06-27 23:06Lack of access controls in the 'ate' management binary of the Tenda RX2 Pro 16.03.30.14 allows an unauthenticated remote attacker to perform unauthorized configuration changes for any router where 'ate' has been enabled by sending a crafted UDP packet. Shenzhen Tenda Technology Co.,Ltd. of RX2 Pro Firmware contains an access control vulnerability.Information may be obtained and information may be tampered with. Tenda RX2 Pro is a high-performance WiFi 6 signal amplifier from China's Tenda. Attackers can exploit this vulnerability to cause unauthorized configuration changes
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202505-1103",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "rx2 pro",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "16.03.30.14"
},
{
"model": "rx2 pro",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "rx2 pro firmware 16.03.30.14"
},
{
"model": "rx2 pro",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "rx2 pro",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-13839"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-005738"
},
{
"db": "NVD",
"id": "CVE-2025-46629"
}
]
},
"cve": "CVE-2025-46629",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 6.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-13839",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 3.9,
"id": "CVE-2025-46629",
"impactScore": 2.5,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "None",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "JVNDB-2025-005738",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-46629",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "OTHER",
"id": "JVNDB-2025-005738",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2025-13839",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-13839"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-005738"
},
{
"db": "NVD",
"id": "CVE-2025-46629"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Lack of access controls in the \u0027ate\u0027 management binary of the Tenda RX2 Pro 16.03.30.14 allows an unauthenticated remote attacker to perform unauthorized configuration changes for any router where \u0027ate\u0027 has been enabled by sending a crafted UDP packet. Shenzhen Tenda Technology Co.,Ltd. of RX2 Pro Firmware contains an access control vulnerability.Information may be obtained and information may be tampered with. Tenda RX2 Pro is a high-performance WiFi 6 signal amplifier from China\u0027s Tenda. Attackers can exploit this vulnerability to cause unauthorized configuration changes",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-46629"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-005738"
},
{
"db": "CNVD",
"id": "CNVD-2025-13839"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-46629",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2025-005738",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-13839",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-13839"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-005738"
},
{
"db": "NVD",
"id": "CVE-2025-46629"
}
]
},
"id": "VAR-202505-1103",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-13839"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-13839"
}
]
},
"last_update_date": "2025-06-27T23:06:23.678000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda RX2 Pro Access Control Error Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/702411"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-13839"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-284",
"trust": 1.0
},
{
"problemtype": "Inappropriate access control (CWE-284) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-005738"
},
{
"db": "NVD",
"id": "CVE-2025-46629"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://blog.uturn.dev/#/writeups/iot-village/tenda-rx2pro/readme?id=cve-2025-46629-lack-of-authentication-in-ate"
},
{
"trust": 1.8,
"url": "https://www.tendacn.com/us/default.html"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-46629"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-13839"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-005738"
},
{
"db": "NVD",
"id": "CVE-2025-46629"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-13839"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-005738"
},
{
"db": "NVD",
"id": "CVE-2025-46629"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-06-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-13839"
},
{
"date": "2025-05-28T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-005738"
},
{
"date": "2025-05-01T20:15:38.660000",
"db": "NVD",
"id": "CVE-2025-46629"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-06-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-13839"
},
{
"date": "2025-05-28T04:48:00",
"db": "JVNDB",
"id": "JVNDB-2025-005738"
},
{
"date": "2025-05-27T14:24:23.877000",
"db": "NVD",
"id": "CVE-2025-46629"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0RX2\u00a0Pro\u00a0 Access control vulnerabilities in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-005738"
}
],
"trust": 0.8
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.