VAR-202504-1784
Vulnerability from variot - Updated: 2025-04-30 23:10Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via mac2. Shenzhen Tenda Technology Co.,Ltd. of AC10 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.
Tenda AC10 has a buffer overflow vulnerability, which is caused by the mac2 parameter in AdvSetMacMtuWan failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202504-1784",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.10.20"
},
{
"model": "ac10",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac10",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac10",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac10 firmware 16.03.10.20"
},
{
"model": "ac10 v4.0si v16.03.10.20",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08769"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-003841"
},
{
"db": "NVD",
"id": "CVE-2025-25456"
}
]
},
"cve": "CVE-2025-25456",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-08769",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2025-25456",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-003841",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-25456",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "OTHER",
"id": "JVNDB-2025-003841",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-08769",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08769"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-003841"
},
{
"db": "NVD",
"id": "CVE-2025-25456"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via mac2. Shenzhen Tenda Technology Co.,Ltd. of AC10 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\nTenda AC10 has a buffer overflow vulnerability, which is caused by the mac2 parameter in AdvSetMacMtuWan failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-25456"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-003841"
},
{
"db": "CNVD",
"id": "CNVD-2025-08769"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-25456",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2025-003841",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-08769",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08769"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-003841"
},
{
"db": "NVD",
"id": "CVE-2025-25456"
}
]
},
"id": "VAR-202504-1784",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08769"
}
],
"trust": 0.86649562
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08769"
}
]
},
"last_update_date": "2025-04-30T23:10:09.624000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.0
},
{
"problemtype": "Classic buffer overflow (CWE-120) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-003841"
},
{
"db": "NVD",
"id": "CVE-2025-25456"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://gist.github.com/xyqer1/ab1e6a2bd369aaada0666639c843aff0"
},
{
"trust": 1.8,
"url": "https://github.com/xyqer1/tenda-ac10-advsetmacmtuwan-mac2-stackoverflow"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-25456"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08769"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-003841"
},
{
"db": "NVD",
"id": "CVE-2025-25456"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-08769"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-003841"
},
{
"db": "NVD",
"id": "CVE-2025-25456"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-04-27T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-08769"
},
{
"date": "2025-04-23T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-003841"
},
{
"date": "2025-04-15T19:16:07.327000",
"db": "NVD",
"id": "CVE-2025-25456"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-04-29T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-08769"
},
{
"date": "2025-04-23T00:59:00",
"db": "JVNDB",
"id": "JVNDB-2025-003841"
},
{
"date": "2025-04-22T16:43:06.293000",
"db": "NVD",
"id": "CVE-2025-25456"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC10\u00a0 Classic buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-003841"
}
],
"trust": 0.8
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…