VAR-202503-3612
Vulnerability from variot - Updated: 2025-05-09 03:21Tenda W6_S v1.0.0.4_510 has a Buffer Overflow vulnerability in the setcfm function, which allows remote attackers to cause web server crash via parameter funcpara1 passed to the binary through a POST request. Shenzhen Tenda Technology Co.,Ltd. of W6-S Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state. Tenda W6-S is a 300Mbps wireless panel AP designed for large households such as homes, hotels, and villas. It can provide stable wireless network coverage and low-latency network experience.
Tenda W6-S has a buffer overflow vulnerability. The vulnerability is caused by the setcfm function failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to cause a denial of service
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202503-3612",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "w6-s",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0.0.4\\(510\\)"
},
{
"model": "w6-s",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w6-s",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "w6-s",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "w6-s firmware 1.0.0.4(510)"
},
{
"model": "w6 s 1.0.0.4 510",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08905"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004389"
},
{
"db": "NVD",
"id": "CVE-2025-28220"
}
]
},
"cve": "CVE-2025-28220",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-08905",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2025-28220",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2025-004389",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-28220",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2025-004389",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-08905",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08905"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004389"
},
{
"db": "NVD",
"id": "CVE-2025-28220"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda W6_S v1.0.0.4_510 has a Buffer Overflow vulnerability in the setcfm function, which allows remote attackers to cause web server crash via parameter funcpara1 passed to the binary through a POST request. Shenzhen Tenda Technology Co.,Ltd. of W6-S Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state. \u200cTenda W6-S is a 300Mbps wireless panel AP designed for large households such as homes, hotels, and villas. It can provide stable wireless network coverage and low-latency network experience\u200c\u200c. \n\nTenda W6-S has a buffer overflow vulnerability. The vulnerability is caused by the setcfm function failing to correctly verify the length of the input data. Attackers can exploit this vulnerability to cause a denial of service",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-28220"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004389"
},
{
"db": "CNVD",
"id": "CNVD-2025-08905"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-28220",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004389",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-08905",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08905"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004389"
},
{
"db": "NVD",
"id": "CVE-2025-28220"
}
]
},
"id": "VAR-202503-3612",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08905"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08905"
}
]
},
"last_update_date": "2025-05-09T03:21:09.393000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.0
},
{
"problemtype": "Classic buffer overflow (CWE-120) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-004389"
},
{
"db": "NVD",
"id": "CVE-2025-28220"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-28220"
},
{
"trust": 1.0,
"url": "https://github.com/idajea/iot_vuln_1/blob/master/w6_s_v1.0.0.4/setcfm.pdf"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-08905"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004389"
},
{
"db": "NVD",
"id": "CVE-2025-28220"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-08905"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-004389"
},
{
"db": "NVD",
"id": "CVE-2025-28220"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-04-28T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-08905"
},
{
"date": "2025-05-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-004389"
},
{
"date": "2025-03-28T14:15:20.377000",
"db": "NVD",
"id": "CVE-2025-28220"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-04-30T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-08905"
},
{
"date": "2025-05-07T07:59:00",
"db": "JVNDB",
"id": "JVNDB-2025-004389"
},
{
"date": "2025-05-06T18:46:28.957000",
"db": "NVD",
"id": "CVE-2025-28220"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0W6-S\u00a0 Classic buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-004389"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.