VAR-202502-3527

Vulnerability from variot - Updated: 2025-05-30 23:29

Buffer Overflow vulnerability in Vigor2620/LTE200 3.9.8.9 and earlier and Vigor2860/2925 3.9.8 and earlier and Vigor2862/2926 3.9.9.5 and earlier and Vigor2133/2762/2832 3.9.9 and earlier and Vigor165/166 4.2.7 and earlier and Vigor2135/2765/2766 4.4.5.1 and earlier and Vigor2865/2866/2927 4.4.5.3 and earlier and Vigor2962/3910 4.3.2.8/4.4.3.1 and earlier and Vigor3912 4.3.6.1 and earlier allows a remote attacker to execute arbitrary code via the CGI parser's handling of the "Content-Length" header of HTTP POST requests. vigor2620 firmware, vigorlte200 firmware, vigor2860 firmware etc. DrayTek Corporation The product contains a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202502-3527",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "vigor1000b",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.3.2"
      },
      {
        "model": "vigor2926",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "3.9.9.8"
      },
      {
        "model": "vigor2862",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "3.9.9.8"
      },
      {
        "model": "vigor2133",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "3.9.9.2"
      },
      {
        "model": "vigor2765",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.5.5"
      },
      {
        "model": "vigor2865",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.5.8"
      },
      {
        "model": "vigor2927",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.5.8"
      },
      {
        "model": "vigor3910",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.3"
      },
      {
        "model": "vigor2962",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.3"
      },
      {
        "model": "vigor2763",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.5.5"
      },
      {
        "model": "vigor2766",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.5.5"
      },
      {
        "model": "vigor3912",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.3.2"
      },
      {
        "model": "vigor2832",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "3.9.9.2"
      },
      {
        "model": "vigor2860",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "3.9.8.3"
      },
      {
        "model": "vigor2762",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "3.9.9.2"
      },
      {
        "model": "vigor2962",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.3.2"
      },
      {
        "model": "vigorlte200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "3.9.9.1"
      },
      {
        "model": "vigor2135",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.5.5"
      },
      {
        "model": "vigor2925",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "3.9.8.3"
      },
      {
        "model": "vigor2962",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.3.2.9"
      },
      {
        "model": "vigor2866",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.5.8"
      },
      {
        "model": "vigor2620",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "3.9.9.1"
      },
      {
        "model": "vigor3910",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.3.2"
      },
      {
        "model": "vigor2915",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.4.5"
      },
      {
        "model": "vigor3220",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "3.9.8.5"
      },
      {
        "model": "vigor3910",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "4.3.2.9"
      },
      {
        "model": "vigor2952",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "draytek",
        "version": "3.9.8.5"
      },
      {
        "model": "vigor2862",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2927",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2133",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2763",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2925",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2135",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2620",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2765",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2866",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2962",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2766",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor3910",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2860",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2926",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2832",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigorlte200",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2762",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      },
      {
        "model": "vigor2865",
        "scope": null,
        "trust": 0.8,
        "vendor": "draytek",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024338"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-51139"
      }
    ]
  },
  "cve": "CVE-2024-51139",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2024-51139",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2024-024338",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2024-51139",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2024-024338",
            "trust": 0.8,
            "value": "Critical"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024338"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-51139"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer Overflow vulnerability in Vigor2620/LTE200 3.9.8.9 and earlier and Vigor2860/2925 3.9.8 and earlier and Vigor2862/2926 3.9.9.5 and earlier and Vigor2133/2762/2832 3.9.9 and earlier and Vigor165/166 4.2.7 and earlier and Vigor2135/2765/2766 4.4.5.1 and earlier and Vigor2865/2866/2927 4.4.5.3 and earlier and Vigor2962/3910 4.3.2.8/4.4.3.1 and earlier and Vigor3912 4.3.6.1 and earlier allows a remote attacker to execute arbitrary code via the CGI parser\u0027s handling of the \"Content-Length\" header of HTTP POST requests. vigor2620 firmware, vigorlte200 firmware, vigor2860 firmware etc. DrayTek Corporation The product contains a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-51139"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024338"
      }
    ],
    "trust": 1.62
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-51139",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024338",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024338"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-51139"
      }
    ]
  },
  "id": "VAR-202502-3527",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.6666667
  },
  "last_update_date": "2025-05-30T23:29:21.699000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      },
      {
        "problemtype": "Classic buffer overflow (CWE-120) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024338"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-51139"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "http://draytek.com"
      },
      {
        "trust": 1.8,
        "url": "https://medium.com/faraday/advisory-multiple-vulnerabilities-affecting-draytek-routers-78a6cb8b3946"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-51139"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024338"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-51139"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024338"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-51139"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-05-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-024338"
      },
      {
        "date": "2025-02-27T21:15:37.123000",
        "db": "NVD",
        "id": "CVE-2024-51139"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-05-29T05:34:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-024338"
      },
      {
        "date": "2025-05-28T16:23:26.310000",
        "db": "NVD",
        "id": "CVE-2024-51139"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0DrayTek\u00a0Corporation\u00a0 Classic buffer overflow vulnerability in the product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-024338"
      }
    ],
    "trust": 0.8
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.