VAR-202411-1088
Vulnerability from variot - Updated: 2025-04-25 01:39Netgear R8500 v1.0.2.160 was discovered to contain a command injection vulnerability in the sysNewPasswd parameter at password.cgi. This vulnerability allows attackers to execute arbitrary OS commands via a crafted request. of netgear R8500 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state. NETGEAR R8500 is a wireless router from NETGEAR. The vulnerability is caused by the sysNewPasswd parameter in the password.cgi component failing to properly filter special characters and commands in the constructed command
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202411-1088",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "r8500",
"scope": "eq",
"trust": 1.0,
"vendor": "netgear",
"version": "1.0.2.160"
},
{
"model": "r8500",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": "r8500 firmware 1.0.2.160"
},
{
"model": "r8500",
"scope": null,
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "r8500",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
"version": null
},
{
"model": "r8500",
"scope": "eq",
"trust": 0.6,
"vendor": "netgear",
"version": "v1.0.2.160"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-45303"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-022640"
},
{
"db": "NVD",
"id": "CVE-2024-50999"
}
]
},
"cve": "CVE-2024-50999",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 5.5,
"confidentialityImpact": "NONE",
"exploitabilityScore": 5.1,
"id": "CNVD-2024-45303",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 5.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.1,
"id": "CVE-2024-50999",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 5.7,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2024-022640",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-50999",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "OTHER",
"id": "JVNDB-2024-022640",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNVD",
"id": "CNVD-2024-45303",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-45303"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-022640"
},
{
"db": "NVD",
"id": "CVE-2024-50999"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Netgear R8500 v1.0.2.160 was discovered to contain a command injection vulnerability in the sysNewPasswd parameter at password.cgi. This vulnerability allows attackers to execute arbitrary OS commands via a crafted request. of netgear R8500 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state. NETGEAR R8500 is a wireless router from NETGEAR. The vulnerability is caused by the sysNewPasswd parameter in the password.cgi component failing to properly filter special characters and commands in the constructed command",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-50999"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-022640"
},
{
"db": "CNVD",
"id": "CNVD-2024-45303"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-50999",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2024-022640",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-45303",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-45303"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-022640"
},
{
"db": "NVD",
"id": "CVE-2024-50999"
}
]
},
"id": "VAR-202411-1088",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-45303"
}
],
"trust": 1.1115042
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-45303"
}
]
},
"last_update_date": "2025-04-25T01:39:33.922000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for NETGEAR R8500 password.cgi component command injection vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/612631"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-45303"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.0
},
{
"problemtype": "Classic buffer overflow (CWE-120) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-022640"
},
{
"db": "NVD",
"id": "CVE-2024-50999"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://www.netgear.com/about/security/"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-50999"
},
{
"trust": 1.0,
"url": "https://github.com/wudipjq/my_vuln/blob/main/netgear4/vuln_38/38.md"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-45303"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-022640"
},
{
"db": "NVD",
"id": "CVE-2024-50999"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-45303"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-022640"
},
{
"db": "NVD",
"id": "CVE-2024-50999"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-11-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-45303"
},
{
"date": "2025-04-23T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-022640"
},
{
"date": "2024-11-05T15:15:23.960000",
"db": "NVD",
"id": "CVE-2024-50999"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-11-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-45303"
},
{
"date": "2025-04-23T02:17:00",
"db": "JVNDB",
"id": "JVNDB-2024-022640"
},
{
"date": "2025-04-22T18:13:30.633000",
"db": "NVD",
"id": "CVE-2024-50999"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "of netgear \u00a0R8500\u00a0 Classic buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-022640"
}
],
"trust": 0.8
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…