VAR-202410-0075
Vulnerability from variot - Updated: 2025-03-19 23:06Stored XSS, by authenticated users, is caused by poor sanitization of the Login Page Greeting message in DrayTek Vigor310 devices through 4.3.2.6. DrayTek Corporation of vigor3910 Firmware has a cross-site scripting vulnerability.Information may be obtained and information may be tampered with
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202410-0075",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "vigor2962",
"scope": "lt",
"trust": 1.0,
"vendor": "draytek",
"version": "4.4.3.1"
},
{
"model": "vigor3912",
"scope": "lt",
"trust": 1.0,
"vendor": "draytek",
"version": "4.3.6.1"
},
{
"model": "vigor2962",
"scope": "gte",
"trust": 1.0,
"vendor": "draytek",
"version": "4.4.0.0"
},
{
"model": "vigor2862",
"scope": "eq",
"trust": 1.0,
"vendor": "draytek",
"version": "*"
},
{
"model": "vigor2865",
"scope": "lt",
"trust": 1.0,
"vendor": "draytek",
"version": "4.4.5.2"
},
{
"model": "vigor2915",
"scope": "lt",
"trust": 1.0,
"vendor": "draytek",
"version": "4.4.5.3"
},
{
"model": "vigor3220",
"scope": "eq",
"trust": 1.0,
"vendor": "draytek",
"version": "*"
},
{
"model": "vigorlte200",
"scope": "eq",
"trust": 1.0,
"vendor": "draytek",
"version": "*"
},
{
"model": "vigor2962",
"scope": "lt",
"trust": 1.0,
"vendor": "draytek",
"version": "4.3.2.8"
},
{
"model": "vigor3910",
"scope": "gte",
"trust": 1.0,
"vendor": "draytek",
"version": "4.4.0.0"
},
{
"model": "vigor2765",
"scope": "lt",
"trust": 1.0,
"vendor": "draytek",
"version": "4.4.5.3"
},
{
"model": "vigor165",
"scope": "lt",
"trust": 1.0,
"vendor": "draytek",
"version": "4.2.7"
},
{
"model": "vigor3910",
"scope": "lt",
"trust": 1.0,
"vendor": "draytek",
"version": "4.4.3.1"
},
{
"model": "vigor2762",
"scope": "eq",
"trust": 1.0,
"vendor": "draytek",
"version": "*"
},
{
"model": "vigor2763",
"scope": "lt",
"trust": 1.0,
"vendor": "draytek",
"version": "4.4.5.3"
},
{
"model": "vigor2133",
"scope": "eq",
"trust": 1.0,
"vendor": "draytek",
"version": "*"
},
{
"model": "vigor2866",
"scope": "lt",
"trust": 1.0,
"vendor": "draytek",
"version": "4.4.5.2"
},
{
"model": "vigor2926",
"scope": "eq",
"trust": 1.0,
"vendor": "draytek",
"version": "*"
},
{
"model": "vigor2766",
"scope": "lt",
"trust": 1.0,
"vendor": "draytek",
"version": "4.4.5.3"
},
{
"model": "vigor2925",
"scope": "eq",
"trust": 1.0,
"vendor": "draytek",
"version": "*"
},
{
"model": "vigor2620",
"scope": "eq",
"trust": 1.0,
"vendor": "draytek",
"version": "*"
},
{
"model": "vigor1000b",
"scope": "lt",
"trust": 1.0,
"vendor": "draytek",
"version": "4.4.3.1"
},
{
"model": "vigor1000b",
"scope": "gte",
"trust": 1.0,
"vendor": "draytek",
"version": "4.4.0.0"
},
{
"model": "vigor3910",
"scope": "lt",
"trust": 1.0,
"vendor": "draytek",
"version": "4.3.2.8"
},
{
"model": "vigor2832",
"scope": "eq",
"trust": 1.0,
"vendor": "draytek",
"version": "*"
},
{
"model": "vigor166",
"scope": "lt",
"trust": 1.0,
"vendor": "draytek",
"version": "4.2.7"
},
{
"model": "vigor2135",
"scope": "lt",
"trust": 1.0,
"vendor": "draytek",
"version": "4.4.5.3"
},
{
"model": "vigor2952",
"scope": "eq",
"trust": 1.0,
"vendor": "draytek",
"version": "*"
},
{
"model": "vigor2860",
"scope": "eq",
"trust": 1.0,
"vendor": "draytek",
"version": "*"
},
{
"model": "vigor1000b",
"scope": "lt",
"trust": 1.0,
"vendor": "draytek",
"version": "4.3.2.8"
},
{
"model": "vigor3910",
"scope": "eq",
"trust": 0.8,
"vendor": "draytek",
"version": "vigor3910 firmware 4.3.2.8"
},
{
"model": "vigor3910",
"scope": "eq",
"trust": 0.8,
"vendor": "draytek",
"version": "vigor3910 firmware 4.4.0.0 that\u0027s all 4.4.3.1"
},
{
"model": "vigor3910",
"scope": "eq",
"trust": 0.8,
"vendor": "draytek",
"version": null
},
{
"model": "vigor3910",
"scope": null,
"trust": 0.8,
"vendor": "draytek",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-009832"
},
{
"db": "NVD",
"id": "CVE-2024-41587"
}
]
},
"cve": "CVE-2024-41587",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.3,
"id": "CVE-2024-41587",
"impactScore": 2.7,
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"trust": 2.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.4,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2024-41587",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "Low",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2024-41587",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2024-41587",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2024-41587",
"trust": 0.8,
"value": "Medium"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-009832"
},
{
"db": "NVD",
"id": "CVE-2024-41587"
},
{
"db": "NVD",
"id": "CVE-2024-41587"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Stored XSS, by authenticated users, is caused by poor sanitization of the Login Page Greeting message in DrayTek Vigor310 devices through 4.3.2.6. DrayTek Corporation of vigor3910 Firmware has a cross-site scripting vulnerability.Information may be obtained and information may be tampered with",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-41587"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-009832"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-41587",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2024-009832",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-009832"
},
{
"db": "NVD",
"id": "CVE-2024-41587"
}
]
},
"id": "VAR-202410-0075",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.6666667
},
"last_update_date": "2025-03-19T23:06:30.760000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.0
},
{
"problemtype": "Cross-site scripting (CWE-79) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-009832"
},
{
"db": "NVD",
"id": "CVE-2024-41587"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://www.forescout.com/resources/draybreak-draytek-research/"
},
{
"trust": 1.0,
"url": "https://www.forescout.com/resources/draytek14-vulnerabilities"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-41587"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-009832"
},
{
"db": "NVD",
"id": "CVE-2024-41587"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2024-009832"
},
{
"db": "NVD",
"id": "CVE-2024-41587"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-10-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-009832"
},
{
"date": "2024-10-03T19:15:04.310000",
"db": "NVD",
"id": "CVE-2024-41587"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-10-07T03:05:00",
"db": "JVNDB",
"id": "JVNDB-2024-009832"
},
{
"date": "2025-03-18T16:15:22.733000",
"db": "NVD",
"id": "CVE-2024-41587"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "DrayTek\u00a0Corporation\u00a0 of \u00a0vigor3910\u00a0 Cross-site scripting vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-009832"
}
],
"trust": 0.8
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…