An issue was discovered on Alecto IVM-100 2019-11-12 devices. The device comes with a serial interface at the board level. By attaching to this serial interface and rebooting the device, a large amount of information is disclosed. This includes the view password and the password of the Wi-Fi access point that the device used.


[Vulnerability Type] Incorrect Access Control


[Vendor of Product] Alecto


[Affected Product Code Base] Alecto IVM-100 - unknown.


[Attack Type] Physical


[Impact Information Disclosure] true


[Attack Vectors] An attacker needs to open up the device and physically attach wires as well as reboot the device.


[Has vendor confirmed or acknowledged the vulnerability?] true


[Discoverer] Willem Westerhof, Jasper Nota, Martijn Baalman from Qbit cyber security in cooperation with The Dutch consumer organisation


[Reference] https://www.alecto.nl

Use CVE-2019-20462

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202407-2571",
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Willem Westerhof | Secura",
    "sources": [
      {
        "db": "OTHER",
        "id": null
      }
    ],
    "trust": 0.1
  },
  "cve": "CVE-2019-20462",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 0.9,
            "id": "CVE-2019-20462",
            "impactScore": 4.0,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "id": "CVE-2019-20462",
            "trust": 1.0,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-20462"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An issue was discovered on Alecto IVM-100 2019-11-12 devices. The device comes with a serial interface at the board level. By attaching to this serial interface and rebooting the device, a large amount of information is disclosed. This includes the view password and the password of the Wi-Fi access point that the device used. \n\n------------------------------------------\n\n[Vulnerability Type]\nIncorrect Access Control\n\n------------------------------------------\n\n[Vendor of Product]\nAlecto\n\n------------------------------------------\n\n[Affected Product Code Base]\nAlecto IVM-100 - unknown. \n\n------------------------------------------\n\n[Attack Type]\nPhysical\n\n------------------------------------------\n\n[Impact Information Disclosure]\ntrue\n\n------------------------------------------\n\n[Attack Vectors]\nAn attacker needs to open up the device and physically attach wires as well as reboot the device. \n\n------------------------------------------\n\n[Has vendor confirmed or acknowledged the vulnerability?]\ntrue\n\n------------------------------------------\n\n[Discoverer]\nWillem Westerhof, Jasper Nota, Martijn Baalman from Qbit cyber security in cooperation with The Dutch consumer organisation\n\n------------------------------------------\n\n[Reference]\nhttps://www.alecto.nl\n\nUse CVE-2019-20462",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-20462"
      },
      {
        "db": "PACKETSTORM",
        "id": "179811"
      }
    ],
    "trust": 0.99
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-20462",
        "trust": 1.2
      },
      {
        "db": "OTHER",
        "id": "NONE",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "179811",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "PACKETSTORM",
        "id": "179811"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-20462"
      }
    ]
  },
  "id": "VAR-202407-2571",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "OTHER",
        "id": null
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2025-11-18T12:32:03.289000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-284",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-20462"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.0,
        "url": "https://seclists.org/fulldisclosure/2024/jul/14"
      },
      {
        "trust": 1.1,
        "url": "https://www.alecto.nl"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-20462"
      }
    ],
    "sources": [
      {
        "db": "PACKETSTORM",
        "id": "179811"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-20462"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "OTHER",
        "id": null
      },
      {
        "db": "PACKETSTORM",
        "id": "179811"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-20462"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-07-26T13:11:06",
        "db": "OTHER",
        "id": null
      },
      {
        "date": "2024-07-30T12:35:43",
        "db": "PACKETSTORM",
        "id": "179811"
      },
      {
        "date": "2024-11-07T21:15:05.470000",
        "db": "NVD",
        "id": "CVE-2019-20462"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-11-04T18:15:37.853000",
        "db": "NVD",
        "id": "CVE-2019-20462"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Alecto IVM-100 2019-11-12 Information Disclosure",
    "sources": [
      {
        "db": "PACKETSTORM",
        "id": "179811"
      }
    ],
    "trust": 0.1
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "info disclosure",
    "sources": [
      {
        "db": "PACKETSTORM",
        "id": "179811"
      }
    ],
    "trust": 0.1
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…