VAR-202403-2964
Vulnerability from variot - Updated: 2024-12-17 22:36A heap-based memory buffer overflow vulnerability in Rockwell Automation Arena Simulation software could potentially allow a malicious user to insert unauthorized code into the software by overstepping the memory boundaries, which triggers an access violation. Once inside, the threat actor can run harmful code on the system. This affects the confidentiality, integrity, and availability of the product. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor. Rockwell Automation of arena simulation Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Rockwell Automation Arena Simulation Software is a set of simulation software from Rockwell Automation of the United States that provides 3D animation and graphics functions
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202403-2964",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "arena",
"scope": "lt",
"trust": 1.0,
"vendor": "rockwellautomation",
"version": "16.20.03"
},
{
"model": "arena",
"scope": "gte",
"trust": 1.0,
"vendor": "rockwellautomation",
"version": "16.00.00"
},
{
"model": "arena simulation",
"scope": "eq",
"trust": 0.8,
"vendor": "rockwell automation",
"version": "16.00.00 that\u0027s all 16.20.03"
},
{
"model": "arena simulation",
"scope": null,
"trust": 0.8,
"vendor": "rockwell automation",
"version": null
},
{
"model": "arena simulation",
"scope": "eq",
"trust": 0.8,
"vendor": "rockwell automation",
"version": null
},
{
"model": "automation arena simulation software",
"scope": "eq",
"trust": 0.6,
"vendor": "rockwell",
"version": "16.00"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-18332"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-014194"
},
{
"db": "NVD",
"id": "CVE-2024-21913"
}
]
},
"cve": "CVE-2024-21913",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2024-18332",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "PSIRT@rockwellautomation.com",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2024-21913",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2024-21913",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "PSIRT@rockwellautomation.com",
"id": "CVE-2024-21913",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2024-21913",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2024-21913",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2024-18332",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-18332"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-014194"
},
{
"db": "NVD",
"id": "CVE-2024-21913"
},
{
"db": "NVD",
"id": "CVE-2024-21913"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "\nA heap-based memory buffer overflow vulnerability in Rockwell Automation Arena Simulation software could potentially allow a malicious user to insert unauthorized code into the software by overstepping the memory boundaries, which triggers an access violation. Once inside, the threat actor can run harmful code on the system. This affects the confidentiality, integrity, and availability of the product. To trigger this, the user would unwittingly need to open a malicious file shared by the threat actor. Rockwell Automation of arena simulation Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Rockwell Automation Arena Simulation Software is a set of simulation software from Rockwell Automation of the United States that provides 3D animation and graphics functions",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-21913"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-014194"
},
{
"db": "CNVD",
"id": "CNVD-2024-18332"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-21913",
"trust": 3.2
},
{
"db": "ICS CERT",
"id": "ICSA-24-086-03",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU95922371",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2024-014194",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-18332",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-18332"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-014194"
},
{
"db": "NVD",
"id": "CVE-2024-21913"
}
]
},
"id": "VAR-202403-2964",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-18332"
}
],
"trust": 1.33333335
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-18332"
}
]
},
"last_update_date": "2024-12-17T22:36:09.423000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Rockwell Automation Arena Simulation Software Heap Buffer Overflow Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/543371"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-18332"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-122",
"trust": 1.0
},
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Heap-based buffer overflow (CWE-122) [ others ]",
"trust": 0.8
},
{
"problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-014194"
},
{
"db": "NVD",
"id": "CVE-2024-21913"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://www.rockwellautomation.com/en-us/support/advisory.sd-1665.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu95922371/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-21913"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-086-03"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-18332"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-014194"
},
{
"db": "NVD",
"id": "CVE-2024-21913"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-18332"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-014194"
},
{
"db": "NVD",
"id": "CVE-2024-21913"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-04-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-18332"
},
{
"date": "2024-12-10T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-014194"
},
{
"date": "2024-03-26T16:15:10.670000",
"db": "NVD",
"id": "CVE-2024-21913"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-04-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-18332"
},
{
"date": "2024-12-10T00:45:00",
"db": "JVNDB",
"id": "JVNDB-2024-014194"
},
{
"date": "2024-12-17T16:16:24.157000",
"db": "NVD",
"id": "CVE-2024-21913"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Rockwell\u00a0Automation\u00a0 of \u00a0arena\u00a0simulation\u00a0 Out-of-bounds write vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-014194"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.