VAR-202401-0682
Vulnerability from variot - Updated: 2025-03-24 23:47A vulnerability has been identified in SIMATIC IPC1047E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows), SIMATIC IPC647E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows), SIMATIC IPC847E (All versions with maxView Storage Manager < V4.14.00.26068 on Windows). In default installations of maxView Storage Manager where Redfish® server is configured for remote system management, a vulnerability has been identified that can provide unauthorized access. SIMATIC IPC (Industrial PC) is a PC-based automation hardware platform from Siemens
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202401-0682",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "maxview storage manager",
"scope": "lt",
"trust": 1.0,
"vendor": "microchip",
"version": "4.14.00.26068"
},
{
"model": "simatic ipc647e on windows",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v4.14.00.26068"
},
{
"model": "simatic ipc847e on windows",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v4.14.00.26068"
},
{
"model": "simatic ipc1047e on windows",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v4.14.00.26068"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-01398"
},
{
"db": "NVD",
"id": "CVE-2023-51438"
}
]
},
"cve": "CVE-2023-51438",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-01398",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-51438",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "productcert@siemens.com",
"availabilityImpact": "HIGH",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-51438",
"impactScore": 6.0,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-51438",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2023-51438",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2024-01398",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-01398"
},
{
"db": "NVD",
"id": "CVE-2023-51438"
},
{
"db": "NVD",
"id": "CVE-2023-51438"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC IPC1047E (All versions with maxView Storage Manager \u003c V4.14.00.26068 on Windows), SIMATIC IPC647E (All versions with maxView Storage Manager \u003c V4.14.00.26068 on Windows), SIMATIC IPC847E (All versions with maxView Storage Manager \u003c V4.14.00.26068 on Windows). In default installations of maxView Storage Manager where Redfish\u00ae server is configured for remote system management, a vulnerability has been identified that can provide unauthorized access. SIMATIC IPC (Industrial PC) is a PC-based automation hardware platform from Siemens",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51438"
},
{
"db": "CNVD",
"id": "CNVD-2024-01398"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "SIEMENS",
"id": "SSA-702935",
"trust": 1.6
},
{
"db": "NVD",
"id": "CVE-2023-51438",
"trust": 1.6
},
{
"db": "CNVD",
"id": "CNVD-2024-01398",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-01398"
},
{
"db": "NVD",
"id": "CVE-2023-51438"
}
]
},
"id": "VAR-202401-0682",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-01398"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-01398"
}
]
},
"last_update_date": "2025-03-24T23:47:10.989000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for maxView Storage Manager Input Validation Error Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/514116"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-01398"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "CWE-20",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-51438"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.0,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-702935.pdf"
},
{
"trust": 0.6,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-702935.html"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-01398"
},
{
"db": "NVD",
"id": "CVE-2023-51438"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-01398"
},
{
"db": "NVD",
"id": "CVE-2023-51438"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-01398"
},
{
"date": "2024-01-09T10:15:21.077000",
"db": "NVD",
"id": "CVE-2023-51438"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-03-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-01398"
},
{
"date": "2024-01-16T16:16:21.633000",
"db": "NVD",
"id": "CVE-2023-51438"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "maxView Storage Manager Input Validation Error Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-01398"
}
],
"trust": 0.6
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.