VAR-202311-0456

Vulnerability from variot - Updated: 2025-08-17 23:23

Multiple out-of-bounds read vulnerabilities exist in TELLUS Simulator V4.0.17.0 and earlier. If a user opens a specially crafted file (X1 or V9 file), information may be disclosed and/or arbitrary code may be executed. Fuji Electric's TELLUS Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Fuji Electric TELLUS is advanced, user-friendly, and remotely controllable industrial automation software

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202311-0456",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "tellus",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.17.0"
      },
      {
        "model": "tellus",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": "4.0.17.0  and earlier"
      },
      {
        "model": "tellus",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "tellus",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "electric tellus",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "\u003c=v4.0.17.0"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-18177"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017633"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-47583"
      }
    ]
  },
  "cve": "CVE-2023-47583",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.2,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 3.9,
            "id": "CNVD-2025-18177",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2023-47583",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-47583",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-47583",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2023-47583",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-18177",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-18177"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017633"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-47583"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Multiple out-of-bounds read vulnerabilities exist in TELLUS Simulator V4.0.17.0 and earlier. If a user opens a specially crafted file (X1 or V9 file), information may be disclosed and/or arbitrary code may be executed. Fuji Electric\u0027s TELLUS Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Fuji Electric TELLUS is advanced, user-friendly, and remotely controllable industrial automation software",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-47583"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017633"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-18177"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-47583",
        "trust": 3.2
      },
      {
        "db": "JVN",
        "id": "JVNVU93840158",
        "trust": 1.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017633",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-18177",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-18177"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017633"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-47583"
      }
    ]
  },
  "id": "VAR-202311-0456",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-18177"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-18177"
      }
    ]
  },
  "last_update_date": "2025-08-17T23:23:18.791000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Fuji Electric TELLUS Out-of-Bounds Read Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/717926"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-18177"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-125",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds read (CWE-125) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017633"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-47583"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://jvn.jp/en/vu/jvnvu93840158/"
      },
      {
        "trust": 1.8,
        "url": "https://hakko-elec.co.jp/site/download/03tellus_inf/index.php"
      },
      {
        "trust": 1.8,
        "url": "https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-47583"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-18177"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017633"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-47583"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-18177"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017633"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-47583"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-08-11T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-18177"
      },
      {
        "date": "2024-01-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017633"
      },
      {
        "date": "2023-11-15T06:15:28.170000",
        "db": "NVD",
        "id": "CVE-2023-47583"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-08-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-18177"
      },
      {
        "date": "2024-01-09T05:46:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-017633"
      },
      {
        "date": "2023-11-22T15:04:48.877000",
        "db": "NVD",
        "id": "CVE-2023-47583"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fuji Electric\u0027s \u00a0TELLUS\u00a0 Out-of-bounds read vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-017633"
      }
    ],
    "trust": 0.8
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…