VAR-202310-0178

Vulnerability from variot - Updated: 2025-03-22 23:41

Improper Authentication vulnerability in Mitsubishi Electric Corporation MELSEC-F Series main modules allows a remote unauthenticated attacker to obtain sequence programs from the product or write malicious sequence programs or improper data in the product without authentication by sending illegitimate messages. This vulnerability information is provided by the developer for the purpose of disseminating it to product users. JPCERT/CC Report to JPCERT/CC Coordinated with the developer.As a result of a crafted message being sent by a third party who has access to the product, a sequence program, etc. is read without authentication, or a malicious sequence program, fraudulent device data, etc. is written. , information may be leaked or falsified. The expected impact will differ depending on the number of digits of the keyword you have set. * 8 In the case of digit keyword authentication, information leakage and information falsification due to lack of authentication * 16 For digit keyword authentication: Authentication evasion due to authentication failure For details, please check the information provided by the developer. Mitsubishi Electric MELSEC-F Series is a basic micro PLC with scalable analog and communication functions for industrial control equipment of Mitsubishi Electric Corporation of Japan

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202310-0178",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "fx3g-60mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ga-60mt-cm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-24mt\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-64mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-30mt\\/ess-2ad",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-48mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-32mr\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-14mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-24mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-40mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-4ad-ptw-adp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-14 mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ge-24mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-64ms\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-16mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-14mt\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-14 mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-24mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3sa-20mr-cm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3uc-16mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-14mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-14mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-4ad-tc-adp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-30mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-24mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-10mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-14 mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-40 mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ge-40mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3sa-30mr-cm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-60mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-60 mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-60 mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3uc-16mt\\/dss-p4",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-60 mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-32mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3sa-30mt-cm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-40mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-48mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ge-24mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-64mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3uc-32mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-40 mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ga-24mt-cm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-cnv-adp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ge-40mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-48mr\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-80mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3uc-16mr\\/d-t",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ge-40mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3gc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-14mr\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-16mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-48mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-60mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-10mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-128mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-32mt\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-14mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ge-40mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-16mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-14 mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-14mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-60 mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-30mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-64mr\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-enet-p502",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3gc-32mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-10mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3uc-32mt-lt-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-20mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-48mt\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-20mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-32mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-64mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-60mt\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-40mr\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-485adp\\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-24 mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-4ad-adp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-14mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-40 mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-60mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-40mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-16mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-16mt\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-48mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ga-40mt-cm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-16mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ge-40mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ge-40mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-128mr\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-48mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-20mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ga-40mr-cm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-24mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-4ad-pt-adp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3sa-14mt-cm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-24 mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-3a-adp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-80mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-80mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-10mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-20mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-40 mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-64mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-32mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3uc-96mt\\/d",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3uc-32mt\\/d",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3uc-64mt\\/d",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-128mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-32mr\\/ua1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-32ms\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3sa-10mt-cm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3sa-10mr-cm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-14 mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ge-24mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-14mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-enet-l",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-64mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3uc-64mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-32mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-30mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ge-24mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-32mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3uc-16mt\\/d",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ge-24mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-80mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-24 mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-40 mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3sa-14mr-cm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-40mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-80mt\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-40 mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-4da-adp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-60mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-40mt\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-14mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-60mr\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-40mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ga-60mr-cm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3uc-16mt\\/d-p4",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-30mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-24mr\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-48mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-20mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-24mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ga-24mr-cm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-24 mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-64mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-10mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3uc-96mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-30mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-24 mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-10mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-24mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-40mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-enet",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-20mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-64mt\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-30mt\\/es-2ad",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-60mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3ge-24mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-16mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-16mr\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-14 mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3sa-20mt-cm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-30mr\\/es-2ad",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3uc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-4da-pnk-adp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-14mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3gc-32mt\\/d",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-24 mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-60 mr\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3uc-32mt-lt",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-128mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-80mt\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3uc-16mr\\/ds-t",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-14mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-14mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-32 mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-64mr\\/ua1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-32mr\\/ds",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-128mt\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-80mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-14mt\\/es",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-232adp\\",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3u-80mr\\/es-a",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s-30mt\\/ess",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3g-60 mt\\/dss",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mitsubishielectric",
        "version": null
      },
      {
        "model": "fx3s",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "fx3gc",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "fx3u",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "fx3uc",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "fx3g",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u4e09\u83f1\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "electric melsec-f series",
        "scope": null,
        "trust": 0.6,
        "vendor": "misubishi",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-00210"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003809"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-4562"
      }
    ]
  },
  "cve": "CVE-2023-4562",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 9.4,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2024-00210",
            "impactScore": 9.2,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2023-4562",
            "impactScore": 5.2,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "OTHER",
            "availabilityImpact": "None",
            "baseScore": 9.1,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2023-003809",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2023-4562",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
            "id": "CVE-2023-4562",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2023-003809",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-00210",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-00210"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003809"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-4562"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-4562"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Improper Authentication vulnerability in Mitsubishi Electric Corporation MELSEC-F Series main modules allows a remote unauthenticated attacker to obtain sequence programs from the product or write malicious sequence programs or improper data in the product without authentication by sending illegitimate messages. This vulnerability information is provided by the developer for the purpose of disseminating it to product users. JPCERT/CC Report to JPCERT/CC Coordinated with the developer.As a result of a crafted message being sent by a third party who has access to the product, a sequence program, etc. is read without authentication, or a malicious sequence program, fraudulent device data, etc. is written. , information may be leaked or falsified. The expected impact will differ depending on the number of digits of the keyword you have set. * 8 In the case of digit keyword authentication, information leakage and information falsification due to lack of authentication * 16 For digit keyword authentication: Authentication evasion due to authentication failure For details, please check the information provided by the developer. Mitsubishi Electric MELSEC-F Series is a basic micro PLC with scalable analog and communication functions for industrial control equipment of Mitsubishi Electric Corporation of Japan",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-4562"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003809"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-00210"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-4562"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-4562",
        "trust": 3.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-285-13",
        "trust": 1.9
      },
      {
        "db": "JVN",
        "id": "JVNVU90509290",
        "trust": 1.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003809",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-00210",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-4562",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-00210"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-4562"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003809"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-4562"
      }
    ]
  },
  "id": "VAR-202310-0178",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-00210"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-00210"
      }
    ]
  },
  "last_update_date": "2025-03-22T23:41:08.407000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "MELSEC-F\u00a0 Vulnerabilities of information leakage, information tampering, and authentication bypass in the basic unit",
        "trust": 0.8,
        "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2023-012.pdf"
      },
      {
        "title": "Patch for Mitsubishi Electric MELSEC-F Series Authentication Error Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/513051"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-00210"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003809"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-287",
        "trust": 1.0
      },
      {
        "problemtype": "Inappropriate authentication (CWE-287) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003809"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-4562"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-13"
      },
      {
        "trust": 1.7,
        "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-012_en.pdf"
      },
      {
        "trust": 1.1,
        "url": "https://jvn.jp/vu/jvnvu90509290/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu90509290/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-4562"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-00210"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-4562"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003809"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-4562"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-00210"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-4562"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003809"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-4562"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-01-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-00210"
      },
      {
        "date": "2023-10-13T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-4562"
      },
      {
        "date": "2023-10-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-003809"
      },
      {
        "date": "2023-10-13T02:15:09.917000",
        "db": "NVD",
        "id": "CVE-2023-4562"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-03-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-00210"
      },
      {
        "date": "2023-10-13T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-4562"
      },
      {
        "date": "2024-05-17T08:37:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-003809"
      },
      {
        "date": "2023-10-23T19:15:51.397000",
        "db": "NVD",
        "id": "CVE-2023-4562"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Made by Mitsubishi Electric \u00a0MELSEC-F\u00a0 Improper authentication vulnerability in series base unit",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003809"
      }
    ],
    "trust": 0.8
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…