A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software.   Users are granted elevated permissions on certain product services when the software is installed.  Due to this misconfiguration, a malicious user could potentially achieve remote code execution on the targeted software. It is used to build programs for PLCs. No detailed vulnerability details are currently provided

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202212-2066",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "studio 5000 logix emulate",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "34.00"
      },
      {
        "model": "studio 5000 logix emulate",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "rockwellautomation",
        "version": "20.011"
      },
      {
        "model": "automation rockwell automation studio logix designer",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "rockwell",
        "version": "5000v.20-33"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13564"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-3156"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Rockwell Automation reported this vulnerability to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3803"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-3156",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.8,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 3.1,
            "id": "CNVD-2024-13564",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:L/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2022-3156",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-3156",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "PSIRT@rockwellautomation.com",
            "id": "CVE-2022-3156",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-13564",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202212-3803",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13564"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3803"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-3156"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-3156"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software. \u00a0 Users are granted elevated permissions on certain product services when the software is installed. \u00a0Due to \nthis misconfiguration, a malicious user could potentially achieve remote code execution on the targeted software. It is used to build programs for PLCs. No detailed vulnerability details are currently provided",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-3156"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-13564"
      },
      {
        "db": "VULHUB",
        "id": "VHN-430798"
      }
    ],
    "trust": 1.53
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-3156",
        "trust": 2.3
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-13564",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2022.6662",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-356-02",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3803",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-430798",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13564"
      },
      {
        "db": "VULHUB",
        "id": "VHN-430798"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3803"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-3156"
      }
    ]
  },
  "id": "VAR-202212-2066",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13564"
      },
      {
        "db": "VULHUB",
        "id": "VHN-430798"
      }
    ],
    "trust": 0.06999999999999999
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13564"
      }
    ]
  },
  "last_update_date": "2025-03-22T23:40:00.510000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Rockwell Automation Studio 5000 Logix Designer Access Control Error Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/534226"
      },
      {
        "title": "Rockwell Automation Studio 5000 Logix Designer Remediation measures for authorization problem vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=220326"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13564"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3803"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-287",
        "trust": 1.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-430798"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-3156"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137846"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-3156"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-356-02"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2022.6662"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-3156/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13564"
      },
      {
        "db": "VULHUB",
        "id": "VHN-430798"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3803"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-3156"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13564"
      },
      {
        "db": "VULHUB",
        "id": "VHN-430798"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3803"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-3156"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-03-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-13564"
      },
      {
        "date": "2022-12-27T00:00:00",
        "db": "VULHUB",
        "id": "VHN-430798"
      },
      {
        "date": "2022-12-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202212-3803"
      },
      {
        "date": "2022-12-27T19:15:10.357000",
        "db": "NVD",
        "id": "CVE-2022-3156"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-03-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-13564"
      },
      {
        "date": "2023-01-06T00:00:00",
        "db": "VULHUB",
        "id": "VHN-430798"
      },
      {
        "date": "2023-01-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202212-3803"
      },
      {
        "date": "2023-11-07T03:50:51.807000",
        "db": "NVD",
        "id": "CVE-2022-3156"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3803"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Rockwell Automation Studio 5000 Logix Designer Access Control Error Vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-13564"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "authorization issue",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3803"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.