VAR-202212-1812

Vulnerability from variot - Updated: 2025-12-19 22:49

Fuji Electric Tellus Lite V-Simulator versions 4.0.12.0 and prior are vulnerable to a stack-based buffer overflow which may allow an attacker to execute arbitrary code. (DoS) It may be in a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of X1 files in the V-Simulator 6 application. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. It is primarily used to collect real-time data from devices such as PLCs (Programmable Logic Controllers), temperature controllers, and inverters

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202212-1812",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "tellus lite v-simulator",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "fujielectric",
        "version": "4.0.12.0"
      },
      {
        "model": "tellus lite v-simulator",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": "4.0.12.0  and earlier"
      },
      {
        "model": "tellus lite v-simulator",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u5bcc\u58eb\u96fb\u6a5f",
        "version": null
      },
      {
        "model": "tellus lite",
        "scope": null,
        "trust": 0.7,
        "vendor": "fuji electric",
        "version": null
      },
      {
        "model": "electric fuji electric tellus lite v-simulator",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "fuji",
        "version": "\u003c=4.0.12.0"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-23-821"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-24579"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005820"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-3085"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "kimiya",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-23-821"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2022-3085",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.2,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 3.9,
            "id": "CNVD-2025-24579",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2022-3085",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "OTHER",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2022-005820",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2022-3085",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "REQUIRED",
            "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-3085",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "ics-cert@hq.dhs.gov",
            "id": "CVE-2022-3085",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "OTHER",
            "id": "JVNDB-2022-005820",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "ZDI",
            "id": "CVE-2022-3085",
            "trust": 0.7,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-24579",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202212-3658",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-23-821"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-24579"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3658"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005820"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-3085"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-3085"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "\nFuji Electric Tellus Lite V-Simulator versions 4.0.12.0 and prior are vulnerable to a stack-based buffer overflow which may allow an attacker to execute arbitrary code. (DoS) It may be in a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of X1 files in the V-Simulator 6 application. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. It is primarily used to collect real-time data from devices such as PLCs (Programmable Logic Controllers), temperature controllers, and inverters",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-3085"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005820"
      },
      {
        "db": "ZDI",
        "id": "ZDI-23-821"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-24579"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-3085"
      }
    ],
    "trust": 2.88
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-3085",
        "trust": 4.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-354-01",
        "trust": 2.5
      },
      {
        "db": "JVN",
        "id": "JVNVU90957471",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005820",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-16717",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-23-821",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-24579",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2022.6634",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3658",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-3085",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-23-821"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-24579"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-3085"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3658"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005820"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-3085"
      }
    ]
  },
  "id": "VAR-202212-1812",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-24579"
      }
    ],
    "trust": 1.6
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-24579"
      }
    ]
  },
  "last_update_date": "2025-12-19T22:49:46.010000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "top page",
        "trust": 0.8,
        "url": "https://www.fujielectric.co.jp/"
      },
      {
        "title": "Fuji Electric has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-354-01"
      },
      {
        "title": "Patch for Fuji Electric Tellus Lite V-Simulator Stack Buffer Overflow Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/744661"
      },
      {
        "title": "Fuji Electric Tellus Lite V-Simulator Security vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=218425"
      },
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/Live-Hack-CVE/CVE-2022-3085 "
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-23-821"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-24579"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-3085"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3658"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005820"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005820"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-3085"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-3085"
      },
      {
        "trust": 1.7,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-354-01"
      },
      {
        "trust": 1.5,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-354-01"
      },
      {
        "trust": 0.8,
        "url": "http://jvn.jp/vu/jvnvu90957471/index.html"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-354-01"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-3085/"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2022.6634"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/121.html"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/live-hack-cve/cve-2022-3085"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-23-821"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-24579"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-3085"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3658"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005820"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-3085"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-23-821"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-24579"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-3085"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3658"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005820"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-3085"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-06-08T00:00:00",
        "db": "ZDI",
        "id": "ZDI-23-821"
      },
      {
        "date": "2025-10-22T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-24579"
      },
      {
        "date": "2023-01-19T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-3085"
      },
      {
        "date": "2022-12-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202212-3658"
      },
      {
        "date": "2023-06-14T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-005820"
      },
      {
        "date": "2023-01-19T00:15:10.380000",
        "db": "NVD",
        "id": "CVE-2022-3085"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-06-08T00:00:00",
        "db": "ZDI",
        "id": "ZDI-23-821"
      },
      {
        "date": "2025-11-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-24579"
      },
      {
        "date": "2023-01-19T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-3085"
      },
      {
        "date": "2023-01-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202212-3658"
      },
      {
        "date": "2023-06-14T01:29:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-005820"
      },
      {
        "date": "2023-11-07T03:50:45.970000",
        "db": "NVD",
        "id": "CVE-2022-3085"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3658"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Fuji\u00a0Electric\u00a0Tellus\u00a0Lite\u00a0V-Simulator\u00a0 Stack-based buffer overflow vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-005820"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202212-3658"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…