VAR-202211-0375

Vulnerability from variot - Updated: 2025-12-19 20:09

A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions < V2.50), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions < V2.50), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions < V2.50), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions < V2.50), SICAM P850 (7KG8500-0AA00-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA00-2AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA10-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA10-2AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA30-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA30-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA01-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA01-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA02-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA02-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA11-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA11-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA12-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA12-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA31-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA31-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA32-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA32-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA00-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA00-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA10-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA10-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA30-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA30-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA01-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA01-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA02-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA02-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA11-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA11-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA12-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA12-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA31-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA31-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA32-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA32-2AA0) (All versions < V3.10), SICAM T (All versions < V3.0). Affected devices do not properly validate the Language-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device. Siemens' 7KG9501-0AA01-2AA1 firmware and 7KG9501-0AA31-2AA1 There is an input validation vulnerability in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The POWER METER SICAM Q100 is a multifunctional device for detecting, reporting and analyzing measured values and events

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202211-0375",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "power meter sicam q100",
        "scope": "lt",
        "trust": 1.2,
        "vendor": "siemens",
        "version": "2.50"
      },
      {
        "model": "7kg9501-0aa01-2aa1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.50"
      },
      {
        "model": "7kg9501-0aa31-2aa1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.50"
      },
      {
        "model": "7kg9501-0aa31-2aa1",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "7kg9501-0aa01-2aa1",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75540"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-020516"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43439"
      }
    ]
  },
  "cve": "CVE-2022-43439",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-75540",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "productcert@siemens.com",
            "availabilityImpact": "HIGH",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.1,
            "id": "CVE-2022-43439",
            "impactScore": 6.0,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2022-43439",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-43439",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2022-43439",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-43439",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-43439",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-75540",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202211-2309",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75540"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-2309"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-020516"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43439"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43439"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions \u003c V2.50), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions \u003c V2.50), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions \u003c V2.50), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions \u003c V2.50), SICAM P850 (7KG8500-0AA00-0AA0) (All versions \u003c V3.10), SICAM P850 (7KG8500-0AA00-2AA0) (All versions \u003c V3.10), SICAM P850 (7KG8500-0AA10-0AA0) (All versions \u003c V3.10), SICAM P850 (7KG8500-0AA10-2AA0) (All versions \u003c V3.10), SICAM P850 (7KG8500-0AA30-0AA0) (All versions \u003c V3.10), SICAM P850 (7KG8500-0AA30-2AA0) (All versions \u003c V3.10), SICAM P850 (7KG8501-0AA01-0AA0) (All versions \u003c V3.10), SICAM P850 (7KG8501-0AA01-2AA0) (All versions \u003c V3.10), SICAM P850 (7KG8501-0AA02-0AA0) (All versions \u003c V3.10), SICAM P850 (7KG8501-0AA02-2AA0) (All versions \u003c V3.10), SICAM P850 (7KG8501-0AA11-0AA0) (All versions \u003c V3.10), SICAM P850 (7KG8501-0AA11-2AA0) (All versions \u003c V3.10), SICAM P850 (7KG8501-0AA12-0AA0) (All versions \u003c V3.10), SICAM P850 (7KG8501-0AA12-2AA0) (All versions \u003c V3.10), SICAM P850 (7KG8501-0AA31-0AA0) (All versions \u003c V3.10), SICAM P850 (7KG8501-0AA31-2AA0) (All versions \u003c V3.10), SICAM P850 (7KG8501-0AA32-0AA0) (All versions \u003c V3.10), SICAM P850 (7KG8501-0AA32-2AA0) (All versions \u003c V3.10), SICAM P855 (7KG8550-0AA00-0AA0) (All versions \u003c V3.10), SICAM P855 (7KG8550-0AA00-2AA0) (All versions \u003c V3.10), SICAM P855 (7KG8550-0AA10-0AA0) (All versions \u003c V3.10), SICAM P855 (7KG8550-0AA10-2AA0) (All versions \u003c V3.10), SICAM P855 (7KG8550-0AA30-0AA0) (All versions \u003c V3.10), SICAM P855 (7KG8550-0AA30-2AA0) (All versions \u003c V3.10), SICAM P855 (7KG8551-0AA01-0AA0) (All versions \u003c V3.10), SICAM P855 (7KG8551-0AA01-2AA0) (All versions \u003c V3.10), SICAM P855 (7KG8551-0AA02-0AA0) (All versions \u003c V3.10), SICAM P855 (7KG8551-0AA02-2AA0) (All versions \u003c V3.10), SICAM P855 (7KG8551-0AA11-0AA0) (All versions \u003c V3.10), SICAM P855 (7KG8551-0AA11-2AA0) (All versions \u003c V3.10), SICAM P855 (7KG8551-0AA12-0AA0) (All versions \u003c V3.10), SICAM P855 (7KG8551-0AA12-2AA0) (All versions \u003c V3.10), SICAM P855 (7KG8551-0AA31-0AA0) (All versions \u003c V3.10), SICAM P855 (7KG8551-0AA31-2AA0) (All versions \u003c V3.10), SICAM P855 (7KG8551-0AA32-0AA0) (All versions \u003c V3.10), SICAM P855 (7KG8551-0AA32-2AA0) (All versions \u003c V3.10), SICAM T (All versions \u003c V3.0). Affected devices do not properly validate the Language-parameter in requests to the web interface on port  443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device. Siemens\u0027 7KG9501-0AA01-2AA1 firmware and 7KG9501-0AA31-2AA1 There is an input validation vulnerability in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The POWER METER SICAM Q100 is a multifunctional device for detecting, reporting and analyzing measured values and events",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43439"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-020516"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-75540"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-43439",
        "trust": 3.8
      },
      {
        "db": "SIEMENS",
        "id": "SSA-570294",
        "trust": 3.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-887249",
        "trust": 2.4
      },
      {
        "db": "SIEMENS",
        "id": "SSA-572005",
        "trust": 2.4
      },
      {
        "db": "SIEMENS",
        "id": "SSA-471761",
        "trust": 1.0
      },
      {
        "db": "JVN",
        "id": "JVNVU92214181",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU93762879",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU99464755",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-314-11",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-23-166-03",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-020516",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-75540",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-2309",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75540"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-2309"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-020516"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43439"
      }
    ]
  },
  "id": "VAR-202211-0375",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75540"
      }
    ],
    "trust": 1.6
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75540"
      }
    ]
  },
  "last_update_date": "2025-12-19T20:09:51.286000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Siemens POWER METER SICAM Q100 Input Validation Error Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/360346"
      },
      {
        "title": "Siemens Power Meter Sicam Q100 Enter the fix for the verification error vulnerability",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=213739"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75540"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-2309"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-20",
        "trust": 1.0
      },
      {
        "problemtype": "Inappropriate input confirmation (CWE-20) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-020516"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43439"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-572005.pdf"
      },
      {
        "trust": 2.4,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf"
      },
      {
        "trust": 2.4,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf"
      },
      {
        "trust": 1.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-570294.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-887249.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-572005.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-471761.html"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu93762879/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu92214181/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu99464755/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-43439"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-314-11"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-03"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-43439/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75540"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-2309"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-020516"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43439"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75540"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-2309"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-020516"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43439"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-75540"
      },
      {
        "date": "2022-11-08T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-2309"
      },
      {
        "date": "2023-11-02T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-020516"
      },
      {
        "date": "2022-11-08T11:15:12.003000",
        "db": "NVD",
        "id": "CVE-2022-43439"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-75540"
      },
      {
        "date": "2023-06-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-2309"
      },
      {
        "date": "2023-11-02T08:03:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-020516"
      },
      {
        "date": "2025-12-09T16:17:16.917000",
        "db": "NVD",
        "id": "CVE-2022-43439"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-2309"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens POWER METER SICAM Q100 Input Validation Error Vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-75540"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-2309"
      }
    ],
    "trust": 1.2
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "input validation error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-2309"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.