VAR-202210-0275
Vulnerability from variot - Updated: 2025-01-30 22:05ZoneMinder is a free, open source Closed-circuit television software application. In affected versions the ZoneMinder API Exposes Database Log contents to user without privileges, allows insertion, modification, deletion of logs without System Privileges. Users are advised yo upgrade as soon as possible. Users unable to upgrade should disable database logging. ZoneMinder Exists in a vulnerability related to the lack of authentication.Information may be tampered with
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202210-0275",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "zoneminder",
"scope": "lt",
"trust": 1.0,
"vendor": "zoneminder",
"version": "1.37.24"
},
{
"model": "zoneminder",
"scope": "lte",
"trust": 1.0,
"vendor": "zoneminder",
"version": "1.36.27"
},
{
"model": "zoneminder",
"scope": "gte",
"trust": 1.0,
"vendor": "zoneminder",
"version": "1.37.0"
},
{
"model": "zoneminder",
"scope": "eq",
"trust": 0.8,
"vendor": "zoneminder",
"version": null
},
{
"model": "zoneminder",
"scope": null,
"trust": 0.8,
"vendor": "zoneminder",
"version": null
},
{
"model": "zoneminder",
"scope": "lte",
"trust": 0.8,
"vendor": "zoneminder",
"version": "1.36.27 and earlier"
},
{
"model": "zoneminder",
"scope": "eq",
"trust": 0.8,
"vendor": "zoneminder",
"version": "1.37.0 that\u0027s all 1.37.24"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018649"
},
{
"db": "NVD",
"id": "CVE-2022-39289"
}
]
},
"cve": "CVE-2022-39289",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2022-39289",
"impactScore": 3.6,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "security-advisories@github.com",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2022-39289",
"impactScore": 5.2,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2022-39289",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2022-39289",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "security-advisories@github.com",
"id": "CVE-2022-39289",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2022-39289",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-202210-332",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018649"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-332"
},
{
"db": "NVD",
"id": "CVE-2022-39289"
},
{
"db": "NVD",
"id": "CVE-2022-39289"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "ZoneMinder is a free, open source Closed-circuit television software application. In affected versions the ZoneMinder API Exposes Database Log contents to user without privileges, allows insertion, modification, deletion of logs without System Privileges. Users are advised yo upgrade as soon as possible. Users unable to upgrade should disable database logging. ZoneMinder Exists in a vulnerability related to the lack of authentication.Information may be tampered with",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-39289"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018649"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-39289",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018649",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202210-332",
"trust": 0.6
},
{
"db": "OTHER",
"id": "NONE",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018649"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-332"
},
{
"db": "NVD",
"id": "CVE-2022-39289"
}
]
},
"id": "VAR-202210-0275",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "OTHER",
"id": null
}
],
"trust": 0.01
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"home \u0026 office device"
],
"sub_category": "TV",
"trust": 0.1
}
],
"sources": [
{
"db": "OTHER",
"id": null
}
]
},
"last_update_date": "2025-01-30T22:05:01.937000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "ZoneMinder Repair measures for information disclosure vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=210330"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-332"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-862",
"trust": 1.0
},
{
"problemtype": "CWE-200",
"trust": 1.0
},
{
"problemtype": "CWE-287",
"trust": 1.0
},
{
"problemtype": "Lack of authentication (CWE-862) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018649"
},
{
"db": "NVD",
"id": "CVE-2022-39289"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/zoneminder/zoneminder/commit/34ffd92bf123070cab6c83ad4cfe6297dd0ed0b4"
},
{
"trust": 2.4,
"url": "https://github.com/zoneminder/zoneminder/security/advisories/ghsa-mpcx-3gvh-9488"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-39289"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-39289/"
},
{
"trust": 0.1,
"url": "https://ieeexplore.ieee.org/abstract/document/10769424"
}
],
"sources": [
{
"db": "OTHER",
"id": null
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018649"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-332"
},
{
"db": "NVD",
"id": "CVE-2022-39289"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "OTHER",
"id": null
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018649"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-332"
},
{
"db": "NVD",
"id": "CVE-2022-39289"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-10-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-018649"
},
{
"date": "2022-10-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-332"
},
{
"date": "2022-10-07T21:15:11.553000",
"db": "NVD",
"id": "CVE-2022-39289"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-10-20T08:27:00",
"db": "JVNDB",
"id": "JVNDB-2022-018649"
},
{
"date": "2023-07-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-332"
},
{
"date": "2023-07-14T18:13:15.957000",
"db": "NVD",
"id": "CVE-2022-39289"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-332"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "ZoneMinder\u00a0 Vulnerability regarding lack of authentication in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018649"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-332"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…