VAR-202208-1982

Vulnerability from variot - Updated: 2025-12-19 22:50

TOTOLink A720R V4.1.5cu.532_B20210610 was discovered to contain a command injection vulnerability via the username parameter in /cstecgi.cgi. TOTOLINK of A720R The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The TOTOLINK A720R is a wireless router launched by TOTOLINK, a Chinese electronics company. It features dual-band Wi-Fi and emphasizes high-speed network and signal coverage. Detailed vulnerability information is not currently available

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202208-1982",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "a720r",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "totolink",
        "version": "4.1.5cu.532_b20210610"
      },
      {
        "model": "a720r",
        "scope": null,
        "trust": 0.8,
        "vendor": "totolink",
        "version": null
      },
      {
        "model": "a720r",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "totolink",
        "version": "a720r  firmware  4.1.5cu.532 b20210610"
      },
      {
        "model": "a720r",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "totolink",
        "version": null
      },
      {
        "model": "a720r v4.1.5cu.532 b20210610",
        "scope": null,
        "trust": 0.6,
        "vendor": "totolink",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29723"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015564"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36456"
      }
    ]
  },
  "cve": "CVE-2022-36456",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.8,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 3.1,
            "id": "CNVD-2025-29723",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:L/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2022-36456",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-36456",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2022-36456",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2022-36456",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2025-29723",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202208-3966",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29723"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3966"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015564"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36456"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "TOTOLink A720R V4.1.5cu.532_B20210610 was discovered to contain a command injection vulnerability via the username parameter in /cstecgi.cgi. TOTOLINK of A720R The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The TOTOLINK A720R is a wireless router launched by TOTOLINK, a Chinese electronics company. It features dual-band Wi-Fi and emphasizes high-speed network and signal coverage. Detailed vulnerability information is not currently available",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-36456"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015564"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-29723"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-36456",
        "trust": 3.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015564",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2025-29723",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3966",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29723"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3966"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015564"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36456"
      }
    ]
  },
  "id": "VAR-202208-1982",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29723"
      }
    ],
    "trust": 0.06
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29723"
      }
    ]
  },
  "last_update_date": "2025-12-19T22:50:39.054000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for TOTOLINK A720R Command Injection Vulnerability (CNVD-2025-29723)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/776921"
      },
      {
        "title": "TOTOLink A720R Fixes for command injection vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=205926"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29723"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3966"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-78",
        "trust": 1.0
      },
      {
        "problemtype": "OS Command injection (CWE-78) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015564"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36456"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://github.com/darry-lang1/vuln/tree/main/totolink/a720r/1"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-36456"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-36456/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29723"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3966"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015564"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36456"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2025-29723"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3966"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015564"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-36456"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-12-02T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-29723"
      },
      {
        "date": "2022-08-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-3966"
      },
      {
        "date": "2023-09-27T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-015564"
      },
      {
        "date": "2022-08-25T14:15:09.170000",
        "db": "NVD",
        "id": "CVE-2022-36456"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2025-12-03T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2025-29723"
      },
      {
        "date": "2022-08-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202208-3966"
      },
      {
        "date": "2023-09-27T08:47:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-015564"
      },
      {
        "date": "2023-08-08T14:21:49.707000",
        "db": "NVD",
        "id": "CVE-2022-36456"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3966"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "TOTOLINK\u00a0 of \u00a0A720R\u00a0 in the firmware \u00a0OS\u00a0 Command injection vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-015564"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202208-3966"
      }
    ],
    "trust": 0.6
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…